• Title/Summary/Keyword: AC-DC-AC converter

Search Result 1,024, Processing Time 0.029 seconds

THREE PHASE PWM AC-DC BOOST CONVERTER WITH UNITY POWER FACTOR (단위 역률로 동작하는 3상 PWM AC-DC BOOST콘버어터에 관한 연구)

  • Chun, Chang-Gun;Park, Sung-Jun;Kwon, Soon-Jae;Kim, Chul-U
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.397-399
    • /
    • 1994
  • In this parer, the development of input power factor and the harmonic distortion of line current were showed in the proposed three phase AC-DC converter. We identified that DC voltage in the output terminal has fast dynamic response and has nearly ripple. Moreover, the converter also possesses the regenerative capability which is useful for many applications. The switching frequency of this converter operated with constant in the range of 2KHZ. Finally, simulation and experiment results are presented.

  • PDF

Modeling and Analysis of Three Phase PWM Converter (3상 PWM 컨버터의 모델링 및 해석)

  • 조국춘;박채운;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.328-335
    • /
    • 1999
  • Three phase full bridge rectifier has been used to obtain dc voltage from three phase ac voltage source. The rectifier system has drawbacks that power factor is low and power flow is unidirectional. Therefore, when dc voltage increases due to regeneration of power the dynamic resister for dissipation of regeneration power must be installed. But three phase PWM converter can be controlled to operate with unity power factor and bidirectional power flow. Therefore when the PWM converter is used as do supply system, the dissipating resistor is not necessary. On this thesis, in order to design a controller having good performance, the hee phase PWM converter is completely modeled by using circuit DQ-transformation and thus a general and simple instructive equivalent circuit is obtained; the inductor set becomes a second order gyrator-coupled system and three phase inverter becomes a transformer as well. Under given phase angle(${\alpha}$) and modulation index(MI) of the three phase inverter, the dc and ac characteristics are obtained by analysis of the transformed equivalent circuit The validity of the equivalent circuit is confirmed through PSPICE simulation. And based on the dc and ac characteristics a controller with unity power factor is proposed.

  • PDF

SVPWM controlled the Three-phase AC to DC Boost Converter for High Power Factor (SVPWM 방식의 3상 고역율 AC-DC Boost 컨버터)

  • Na, Jae-Hyeong;Lee, Jung-Hyo;Kim, Kyung-Min;Lee, Su-Won;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.327-331
    • /
    • 2008
  • The problems of power factor and harmonics are occurred in converter system which used to SCRs and diodes as power semiconductor devices IGBT was solved that problem, maintain the input line current with sinusoidal wave current of input power source voltage. In this paper, three phase AC to DC boost converter that operates with unity power factor and sinusoidal input currents is presented. The current control of the converter is based on the space vector PWM strategy with fixed switching frequency and the input current tracks the reference current within one sampling time interval. Space vector PWM strategy for current control was materialized as a digital control method. By using this control strategy low ripples in the output voltage, low harmonics in the input current and fast dynamic responses are achieved with a small capacitance in the dc link.

  • PDF

The new Soft-Switching AC-DC Boost Type Converter using Lossless Snubber (무손실 스너버회로를 이용한 새로운 소프트 스위칭 AC-DC승압형 컨버터)

  • Mun Sang-Pil;Suh Ki-Young;Kim Young-Mun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1226-1228
    • /
    • 2004
  • A novel lossless passive snubber is proposed for soft switching the boost type converters. The proposed snubber does not use any auxiliary switches. but uses two identical snubber capacitors which are charged in parallel at turn off of the main switch and discharged in series at turn on automatically, and the discharged energy is recovered effectively (more than $95[\%]$ recovery) into the output capacitor. Thus, the snubber provides zero voltage switching for the converter main switch, reducing both the turn off losses and the electromagnetic interference(EMI) noise, whitch improves the converter performance. The experimental results of a 20[kHz] 600[W] DC-DC boost converter and a single-phase AC-DC boost rectifier with the new snubber are presented.

  • PDF

Design and Control of DC/AC Converters in Parallel with Diode Rectifiers for Regenerative Applications

  • Gao, Zhigang;Li, Rui;Lu, Qi
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1071-1087
    • /
    • 2017
  • This paper introduces a DC/AC converter, which can be connected in parallel with a diode rectifier for regenerative applications. The DC/AC converter is supposed to transmit regenerative energy to the power grid when a motor is braking. Isolation transformers are not needed in the topology, which can reduce the size and cost. An analysis of the zero-order current existing in the system is carried out. In addition, algorithms to minimize the zero-order current, control the power factor and keep the DC bus voltage stable are discussed. A 55kW industrial prototype is built to verify the proposed analysis and control strategies.

KO AC/DC Converter System Installation Status and Commissioning Plan at ITER Site (이터 초전도자석 전원공급장치 현장 설치현황 및 시운전 계획)

  • Song, Inho;Oh, Jong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.397-401
    • /
    • 2022
  • The construction of the ITER tokamak machine is ongoing at a 77% process rate to achieve the first plasma in 2025. The 18 sets of power supply systems comprising 400 MVA thyristor AC/DC converters for the superconducting magnets supplied by Korea (KO) are being installed with other systems, such as PF converters (China), DC busbars (Russia), and cooling water systems (India), in two buildings (Europe). The system interfaces have been defined during the design stage, and the systems have been manufactured. However, during the on-site installation work, several installation and integration issues emerged due to the manufacturing tolerance and design mistakes. To continue the installation and testing, the engineers of each system resolved the interface issues, planned the commissioning, and integrated the test plan. This paper describes the on-site installation status and issues and the commissioning plan of KO AC/DC converters.

Development of a 10kw stand-alone power processing unit for SOFC (고체산화물형 연료전지를 위한 10㎾급 독립전력변환장치의 개발)

  • 이진희;조진상;장민수;최세완;한수빈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.551-560
    • /
    • 2003
  • This paper summarizes development of a 10KW stand-alone power processing unit for 5KW SOFC-low voltage battery hybrid fuel cell power generation system. The power processing unit Includes three parts a high frequency DC-DC converter boosts low fuel cell voltage, a DC-AC inverter converts a dc voltage into a regulated ac voltage and a bidirectional DC-DC converter charges or discharges the battery. The converter topology, design, control method, and experimental result arc presented to meet the specifications such as efficiency of 90% and cost of $40/KW laid down for the "2003 Future Energy Challenge Competition" organized by the U.S. Department of Energy and IEEE. and IEEE.

Soft-Start Method of Three Phase AC/DC converter for DC Distribution System Using Sliding Mode Controller. (슬라이딩 모드 제어기를 이용한 직류(DC)배전용 3상 AC/DC컨버터의 소프트 스타트 운전기법)

  • Park, Hyeon Woo;Shin, Soo Cheol;Eom, Ju Kyoung;Lee, Taeck Kie;Lee, Kyung Ho;Won, Chung Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.186-187
    • /
    • 2010
  • 최근 직류 출력을 갖는 분산전원 시스템의 증가와 높은 에너지 변환효율을 갖는 직류(DC) 배전 시스템에 대한 관심이 증가하고 있다. 직류(DC) 배전을 빌딩에 적용하기 위해서는 계통연계형 AC/DC 컨버터가 필수적이다. 빌딩용 직류(DC)배전 시스템에서는 다양한 부하들이 상시 대용량의 AC/DC 컨버터에 연결되어 있기 때문에 컨버터의 기동시 과도상태를 최소화한 안정적인 DC전압 확보가 필수적이다. 본 논문에서는 외부 파라미터 변화나 외란에 대한 강인한 성능을 가지는 슬라이딩 모드 제어기를 사용하여 3상 AC/DC 컨버터의 초기 운전 시 발생할 수 있는 DC전압의 오버슈트 저감을 시뮬레이션에 의해 검증하였다.

  • PDF

Interlinking converter considering 1-phase short circuit state of AC-DC microgrid system (AC-DC 마이크로그리드의 각상 1선지락 상태를 고려한 인터링킹 컨버터)

  • Kim, Mi-Na;Choi, Bong-Yeon;Kang, Kyung-Min;Lee, Hoon;An, Chang-Gyun;Won, Chung-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.148-149
    • /
    • 2019
  • Voltage unbalance can be occured in AC-DC microgrid systems when AC loads or AC systems are connected. To solve this problem, 3-phase 4-wire interlinking converter is used. This paper proposes in PLL method that can detect accurate phase and voltage magnitude.

  • PDF

Utility AC Frequency to High Frequency AC Power Frequency Converter without Electrolytic Capacitor Link for Consumer Induction Heating Appliances

  • Sugimura, H.;Eid, A.;Lee, H.W.;Kwon, S.K.;Suh, K.Y.;Nakaoka, M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1364-1367
    • /
    • 2005
  • In this paper, a novel prototype topology of soft switching PWM controlled high frequency AC power conversion circuit without DC voltage smoothing chemical capacitor filter link from the voltage grid of utility frequency AC power supply source with 60Hz-100V or 60Hz-200V is proposed and introduced for innovative consumer induction heating(IH) boiler applications as hot water producer, steamer and super heated vapor steamer.

  • PDF