• Title/Summary/Keyword: AC-AC power converter

Search Result 1,180, Processing Time 0.023 seconds

A study on control strategy of power factor correction for AC-DC power conversion system (AC-DC 전력변환기의 역률개선 제어기법에 관한 연구)

  • Kwak Dong-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.263-266
    • /
    • 2003
  • The high power factor converters are classified step-up, step-up-down and step-down converter, The power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. And the power system brings on a high efficiency and high power factor. When a switch of the step down converter is operated with a commercial frequency(60Hz), a reactor using the converter is gone with a great number of harmonics waveforms of low grade. As results of this, the converter is decreased input power factor and is increased system size. To improved these, this paper proposes a PSM(Pulse Size Modulation) control strategy operated with high power factor.

  • PDF

A Bidirectional Single-Stage DC/AC Converter for Grid Connected Energy Storage Systems

  • Chen, Jianliang;Liao, Xiaozhong;Sha, Deshang
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1026-1034
    • /
    • 2015
  • In this paper, a unified control strategy using the current space vector modulation (CSVM) technique is proposed and applied to a bidirectional three-phase DC/AC converter. The operation of the converter changes with the direction of the power flow. In the charging mode, it works as a buck type rectifier; and during the discharging mode, it operates as a boost type inverter, which makes it suitable as an interface between high voltage AC grids and low voltage energy storage devices. This topology has the following advantages: high conversion efficiency, high power factor at the grid side, tight control of the charging current and fast transition between the charging and discharging modes. The operating principle of the mode analysis, the gate signal generation, the general control strategy and the transition from a constant current (CC) to a constant voltage (CV) in the charging mode are discussed. The proposed control strategy has been validated by simulations and experimental results obtained with a 1kW laboratory prototype using supercapacitors as an energy storage device.

Performance Improvement using Auxiliary Converter on HVDC System (보조 컨버터를 이용한 HVDC 시스템의 특성개선)

  • Kim, Dong-Hee;Lee, Hwa-Chun;Park, Sung-Jun;Nam, Hae-Kon;Choi, Joon-Ho;Kim, Kwang-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.217-224
    • /
    • 2009
  • This paper presents a new AC/DC converter scheme for HVDC system to achieve a high power factor operation. The new AC/DC converter consists of two 12-pulse bridge converters in series: the primary and auxiliary converters. Ignition angles of the main and auxiliary converters are controlled independently to maintain the nominal DC voltage and control auxiliary voltage. The resulted DC voltage obtained by superimposing the above two phase modulated voltages can be controlled very rapidly over a wide range, and a high power factor operation is achieved. Performance improvements in power factor and harmonic distortion are validated by theoretic derivations and experiments with prototype HVDC system. With the proposed converters, investment for reactive power compensation and filter in HVDC system can be saved significantly.

The Single-Phase Voltage-Doubler AC-DC Converter by using a Boost Capacitor (승압용 커패시터를 이용한 단상 배전압 AC-DC 컨버터)

  • Jung, S.H.;Kim, S.D.;Lee, S.H.;Lee, H.W.;Chun, J.H.;Chung, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1103-1105
    • /
    • 2002
  • A conventional AC-DC boost converter has much variation of input current as more increased the load or output voltage by the hysterical control method that is comparing area of current pulse by using PWM method and integration to sinusoidal input current. To improve the problems. in this paper, we propose the single-phase voltage doubler AC-DC converter circuit using the capacitor for boost:confirm characteristics of normal and transition state by using simulation, be stabilized voltage of doubler capacitor for boost, and Identify to get the sinusoidal input current with unity power factor.

  • PDF

Analysis and Comparison of Switching Losses and Temperature using Si and SiC devices applied in Two Stage AC-DC Converter for Battery Pack Testing System (배터리팩 시험기를 위한 2단 구성 AC-DC 컨버터의 Si와 SiC의 손실 및 온도 비교 분석)

  • Seong, Ho-Jae;Choi, Hyeong-Jun;Hong, Seok-Jin;Hyun, Seung-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.397-398
    • /
    • 2016
  • This paper analyzes switching losses, efficiency and temperature depending on Si and SiC devices applied in two stage AC-DC converter. To evaluate the charge and discharge performance and stability of the battery pack, there is a need for a battery pack testing system. To do battery charge and discharge experiment used in battery pack test, A topology, two stage AC-DC converter, has been built. SiC devices more decrease switching losses than that of Si. Also, cooling system was applied in Si and SiC devices. When using SiC devices, it can be confirmed that the size of heat sink is reduced for small loss.

  • PDF

Wide Output Range AC/DC Converter for Rechargeable Battery of Electric Vehicle (광대역 출력을 가지는 전기자동차 배터리 충전용 AC/DC 컨버터)

  • Kim, Young-il;Kim, Hong-jung;Jun, Bum-su;Park, Gwi-chul;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.73-74
    • /
    • 2016
  • This paper proposes a wide output range AC/DC converter for a rechargeable battery of electric vehicle. In the proposed wide output range AC/DC converter for rechargeable battery of electric vehicle, the main transformer in the DC/DC stage is divided by two. Therefore, if the switch is connected to the middle tap, then half of the maximum voltage is applied. Otherwise, it can be applied the full range of the high voltage by connecting the switch to the whole tab. And also, it is designed to have a wide output voltage range by applying Vin/2 made by changing the full-bridge to half-bridge by using the bridge change switch of the input stage. As it can be supplied the wide range output voltage with a single module, it has the advantage of space utilization and cost reduction effect.

  • PDF

A Study on the UPS System based HF-Link AC to DC Converter (고주파 링크 AC/DC 콘버어터를 이용한 UPS 시스템에 관한 연구)

  • Mo, Chang-Ho;Lee, Su-Weon;Kim, Yeeug-Min;Park, Hyun-Chul;Yu, Chul-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.437-439
    • /
    • 1996
  • In this paper, an UPS system using high-frequency link AC to DC converter is Proposed. The AC to DC converter has sinusoidal input current and high power factor. In this UPS system, the waveform of the output voltage has smaller harmonic contents than those of a conventional UPS system. In this paper, an operating principle of the system is presented. This new control technique of the UPS system is capable of providing a wide range regulated output DC voltage compared with the conventional UPS system. Performance of the system carried out through theoretical and experimental means.

  • PDF

A Study on the Four AC/DC Converter Parallel Operation for a Traction Drive (견인용 AC/DC 컨버터 4병렬 운전에 관한 연구)

  • Ryoo, Hong-Je;Woo, Myung-Ho;Kim, Jong-Soo;Kim, Won-Ho;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2671-2673
    • /
    • 1999
  • Front end AC to DC converters of the boost type are used in traction applications for generating the DC link for the inverters. A GTO based converter is usually switched with a switching frequency of 300 to 500Hz, resulting in low frequency harmonic problems. In order to avoid this, multiple converters with phase shifted carrier signals are used to suppress the low frequency harmonics. A detailed study of an AC to DC converter, parallel operated with reduced sensor and improved power-factor in light load conditions is presented in this paper.

  • PDF

Comparision Analysis of SiC and Si Loss in 3-Phase AC/DC Converter for Battery Pack Testing System (배터리 팩 시험기용 3상 AC/DC 컨버터에서의 SiC 및 Si 소자에 대한 손실 비교 분석)

  • Park, Sae-Hee;Hyun, Seung-Wook;Seong, Ho-Jae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.363-364
    • /
    • 2017
  • This paper analyzes switching losses and efficiency depending on SiC and Si devices applied in 3-phase AC/DC Converter for Battery Pack Testing System. The switch elements of the 3-phase AC/DC Converter is compared to Si and SiC-based elements and analyzed through comparison of each switching loss by simulation results.

  • PDF

The High Power AC-DC Buck Converter of High Efficienty Using Loss-Less Snubber (로스레스 스너버를 사용한 고효율의 대용량 AC-DC 강압형 컨버터)

  • 문상필;서기영;이현우
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.951-954
    • /
    • 1998
  • This paper proposed that a high power AC-DC buck converter topology of high efficiency using loss-less snubber operates with four chopper connecting a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative resutls on computer is included to confirm the validity of the analytical results. The partial resonant circuit makes use of a inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source of rresonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF