• Title/Summary/Keyword: AC-AC power conversion

Search Result 309, Processing Time 0.03 seconds

Novel Buck Mode Three-Level Direct AC Converter with a High Frequency Link

  • Li, Lei;Guan, Yue;Gong, Kunshan;Li, Guangqiang;Guo, Jian
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.407-417
    • /
    • 2018
  • A novel family of Buck mode three-level direct ac converters with a high frequency link is proposed. These converters can transfer an unsteady high ac voltage with distortion into a regulated sinusoidal voltage with a low THD at the same frequency. The circuit configuration is constituted of a three-level converter, high frequency transformer, cycloconverter, as well as input and output filters. The topological family includes forward, push-pull, half-bridge, and full-bridge modes. In order to achieve a reliable three-level ac-ac conversion, and to overcome the surge voltage and surge current of the cycloconverter, a phase-shifted control strategy is introduced in this paper. A prototype is presented with experimental results to demonstrate that the proposed converters have five advantages including high frequency electrical isolation, lower voltage stress of the power switches, bi-directional power flow, low THD of the output voltage, and a higher input power factor.

Elemination of Low Order Harmonics from STATCOM using SHE-PWM (SHE-PWM을 적용한 STATCOM에 의한 저차고조파 제거 방법)

  • Choi, Soon-Ho;Kim, Chan-Ki;Lee, Seong-Doo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.450-456
    • /
    • 2014
  • In HVDC converters that employ a line-commutated control, reactive power is absorbed by the rectifier and inverter terminals during AC/DC conversion. An AC filter usually consists of filters and large shunt capacitors to supply reactive power to the HVDC station. When STATCOM is used to supply reactive power to the HVDC system with AC filter, the low-order harmonics generated from STATCOM can result in a resonance between the shunt capacitor and AC network. Therefore, a control strategy based on selective harmonic elimination is adopted to minimize the low-order harmonics from STATCOM. The cancellation of harmonic instabilities is verified through simulations in PSCAD/EMTDC.

Bridgeless High Efficiency ZVZCS Power Factor Correction Circuit for PDP Power Module (PDP용 브리지가 없는 고효율 ZVZCS 역률개선회로)

  • Cho Kyu-Min;Yu Byung-Gyu;Moon Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.704-708
    • /
    • 2004
  • Recently, many nation have released standard such as IEC 61000-3-2 and IEEE 59, which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC Line. Therefore, Plasma Display Panel (PDP) which is highlightened in digital display device also has the Power Factor Correction (PFC) circuit to meet the harmonic requirements. In PDP power module, the conventional boost converter is usually used for the PFC circuit. However, it comes serious thermal problem on it's bridge diode due to heat of PDP, and therefore the system stability is not guaranteed. In this paper, the bridgeless boost converter, which is used for PFC circuit of the PDP power module, is designed and verified the possibility of the application in a practical product in a view of efficiency, component count, temperature and etc.

  • PDF

New Resonant AC Link Snubber-Assisted Three-Phase Soft-Switching PWM Inverter and Its Comparative Characteristics Evaluations

  • Yoshida, Masanobu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.239-248
    • /
    • 2003
  • This paper presents a novel prototype of three-phase voltage source type zero voltage soft-switching inverter with the auxiliary resonant snubbers suitable for high-power applications with IGBT power module packages in order to reduce their switching power losses as well as electromagnetic conductive and radiative noises. A proposed single inductor-assisted resonant AC link snubber circuit topology as one of some auxiliary resonant commutation snubbers developed previously to achieve the zero voltage soft-switching (ZVS) for the three-phase voltage source type sinewave PWM inverter operating under the instantaneous space voltage vector modulation is originally demonstrated as compared with the other types of resonant AC link snubber circuit topologies. In addition to this, its operation principle and unique features are described in this paper. Furthermore, the practical basic operating performances of the new conceptual instantaneous space voltage vector modulation resonant AC link snubber-assisted three-phase voltage source type soft-switching PWM inverter using IGBT power module packages are evaluated and discussed on the basis of switching voltage and current waveforms, output line to line voltage quality, power loss analysis, actual power conversion efficiency and electromagnetic conductive and radiative noises from an experimental point of view, comparing with those of conventional three-phase voltage source hard-switching PWM inverter using IGBT power modules.

A Power Losses Analysis of AC Railway Power Feeding Network using Adaptive Voltage Control (능동형 전압제어를 통한 교류 전기철도 급전망에 대한 전력손실 분석)

  • Jung, Hosung;Kim, Hyungchul;Shin, Seongkuen;Kim, Jinho;Yoon, Kiyong;Cho, Yonghyeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1621-1627
    • /
    • 2013
  • This paper compares power losses between voltage controlled before and after using power conversion device in AC feeding system. For this purpose we present voltage control procedures and criteria and model high speed line and train using PSCAD/EMTDC to compare power losses in various feeding condition. Power losses of the simulation result in power control before and after in single point feeding system was reduced maximum 0.37 MW(23.8 %) and average 0.23 MW(20.5 %) when one vehicle load operates maximum load condition. When three vehicles operate maximum load condition in one feeder section, power losses after voltage control was reduced 1.03 MW(49.5%) compared to before voltage control. And, power loss of parallel feeding system is reduced the average 0.08 MW(7.2 %) compared to the single feeding system. In conclusion, adaptive voltage control method using power conversion device can reduce power losses compared with existing method.

The Control of PWM Dual Converters for AC-DC Conversion (AC-DC 변환을 위한 PWM Dual 컨버터의 제어)

  • 정연택;김원철;이사영;조영철;박현준;김길동;이미영
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.314-317
    • /
    • 1997
  • The purpose of this study is developing a converter which is able to convert a 300[KW] power, and is a DC power supply output a 1500[V] DC voltage for inverter driving. The power converter is driven by two converter serisely and keep a high power factor of power source. This system is haven all the characteristic of voltage source converter by having a processing ability of regenerating power. The two converters controls a PWM modulation and output voltage using a only one 16 bit DSP processor.

  • PDF

Balanced Forward-Flyback Converter for High Efficiency and High Power Factor LED Driver (고효율 및 고역률 LED 구동회로 위한 Balanced Forward-Flyback 컨버터)

  • Hwang, Min-Ha;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.492-500
    • /
    • 2013
  • A balanced forward-flyback converter for high efficiency and high power factor using a foward and flyback converter topologies is proposed in this paper. The conventional AC/DC flyback converter can achieve a good power factor but it has the high offset current through the transformer magnetizing inductor, which results in a large core loss and low power conversion efficiency. And, the conventional forward converter can achieve the good power conversion efficiency with the aid of the low core loss but the input current dead zone near zero cross AC input voltage deteriorates the power factor. On the other hand, since the proposed converter can operate as the forward and flyback converters during switch turn-on and turn-off periods, respectively, it cannot only perform the power transfer during an entire switching period but also achieve the high power factor due to the flyback operation. Moreover, since the current balanced capacitor can minimize the offset current through the transformer magnetizing inductor regardless of the AC input voltage, the core loss and volume of the transformer can be minimized. Therefore, the proposed converter features a high efficiency and high power factor. To confirm the validity of the proposed converter, theoretical analysis and experimental results from a prototype of 24W LED driver are presented.

Performance of Double Fed Induction Machine at Sub- and Super-Synchronous Speed in Wind Energy Conversion System

  • Eskander, Mona N.;Saleh, Mahmoud A.;El-Hagry, Mohsen M.T.
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.575-581
    • /
    • 2009
  • In this paper two modes of operating a wound rotor induction machine as a generator at sub-and super-synchronous speeds in wind energy conversion systems are investigated. In the first mode, known as double fed induction generator (DFIG), the rotor circuit is fed from the ac mains via a controlled rectifier and a forced commutated inverter. Adjusting the applied rotor voltage magnitude and phase leads to machine operation as a generator at sub-synchronous speeds. In the second mode, the machine is operated in a slip recovery scheme where the slip energy is fed back to the ac mains via a rectifier and line commutated inverter. This mode is described as double output induction generator (DOIG) leading to increase the efficiency of the wind-to electrical energy conversion system. Simulated results of both modes are presented. Experimental verification of the simulated results are presented for the DOIG mode of operation, showing larger amount of power captured and better power factor when compared to conventional induction generators.

A Study on a Performance Analysis of Direct-Conversion Receiver Using AC-Coupling Method in Additive White Gaussian Noise Channel Environment (AWGN 채널환경에서 AC-Coupling기법을 이용한 Direct-Conversion 수신기의 성능분석에 관한 연구)

  • 박성진;김칠성;성태경;조형래
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.205-209
    • /
    • 2000
  • Modem wireless communication equipments provides various multimedia and aims at the development of low-power, minimum size and weight, and low-cost implimentations. Because of the heterodyne architecture which was invented many decades ago in the wireless communication system using too many components, it was difficult to make it small, compact and On-Chip so it does not proper for future communication. That gives rise a new developing architecture, so called, Direct Conversion. Because The Direct Conversion down-converts the wireless frequency band to baseband directly, it does not need using additive components and has a merit of reduction in power dissipation. We describes the Direct Conversion architecture and DC-Offset, which must be solved, theorectically and predicts system performance enhancement when adopt the AC-Coupling method.

  • PDF

A single-stage ac/dc converter with high power factor and low power loss (고역율, 저손실 1단 교류/직류 변환기)

  • 차영길;박성우;백주원;김흥근
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.413-416
    • /
    • 1997
  • In this paper, we propose a new single-stage isolated switching power supply. The proposed converter reduces the diode conduction loss and offer both the high input Power factor and the direction conversion from the ac line to a dc output voltage. This paper present the Operational principle, analysis and control and experimental results of a 100W prototype.

  • PDF