• Title/Summary/Keyword: AC-3

Search Result 3,037, Processing Time 0.03 seconds

Development of Potassium Impregnated Carbon Absorbents for Indoor CO2 Adsorption (K계열 함침 탄소계 흡착제의 실내 저농도 이산화탄소 흡착성능 강화)

  • Jeong, Se-Eun;Wang, Shuang;Lee, Yu-Ri;Won, Yooseob;Kim, Jae-Young;Jang, Jae Jun;Kim, Hana;Jo, Sung-ho;Park, Young Cheol;Nam, Hyungseok
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.606-612
    • /
    • 2022
  • Relatively high indoor CO2 concentration (>1,000 ppm) has a negative impact on human health. In this work, indoor CO2 adsorbent was developed by impregnating KOH or K2CO3 on commercial activated carbon, named as KOH/AC and K2CO3/AC. Commercial activated carbon (AC) showed relatively high BET surface area (929 m2/g) whereas KOH/AC and K2CO3/AC presented lower BET surface area of 13.6 m2/g and 289 m2/g. Two experimental methods of TGA (2,000 ppmCO2, weight basis) and chamber test (initial concentration: 2,000 ppmCO2, CO2 IR analyzer) were used to investigate the adsorption capacity. KOH/AC and K2CO3/AC exhibited similar adsorption capacities (145~150 mgCO2/g), higher than K2CO3/Al+Si supports adsorbent (84.1 mgCO2/gsample). Similarly, chamber test also showed similar trend. Both KOH/AC and K2CO3/AC represented higher adsorption capacities (KOH/AC: 93.5 mgCO2/g K2CO3/AC: 94.5 mgCO2/gsample) K2CO3/Al+Si supports. This is due to the KOH or K2CO3 impregnation increased alkaline active sites (chemical adsorption), which is beneficial for CO2 adsorption. In addition, the regeneration test results showed both K-based adsorbents pose a good regeneration and reusability. Finally, the current study suggested that both KOH/AC and K2CO3/AC have a great potential to be used as CO2 adsorbent for indoor CO2 adsorption.

The Study of Distance and Near AC/A Ratio by Stimulus (조절자극 방식에 따른 원거리와 근거리 AC/A비에 관한 연구)

  • Jo, Tae-Sik;Kim, In-Suk;Jang, Jung-Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Purpose: This study was to investigate that near gradient AC/A ratio could be used to prescribe a patient with distance exophoria, we compared the difference between distance gradient AC/A ratio and near gradient AC/A ratio. Also, this thesis was to understand the relationship between calculated AC/A ratio and gradient AC/A ratio. Methods: Objective and subjective refractive error were corrected and we used Howell (3 m) chart for distance phoria tests and Howell-Kim (40 cm) chart for near phoria tests. The near gradient AC/A ratio and calculated AC/A ratio were used by Howell-Kim (40 cm) combined with +1.00 D, -1.00 D, +2.00 D and -2.00 D. Results: The average value of distance exophoria was 1.17${\pm}$1.17 $\Delta$, and the average value of near exophoria was 3.71${\pm}$2.80 $\Delta$ (t-test. p<0.001). The correlation of distance phoria with near phoria was little higher (r = 0.59, p < 0.001). Gradient AC/A ratios depending on measuring distance and stimulus were higher (r = 0.11~0.53. P < 0.001), when distance was shorter and stimulus to accommodation was more. Also, stimulus to accommodation by plus lens was higher than stimulus to accommodation by minus lens (paired t-test. p < 0.001). There was negative correlation between calculated AC/A ratio and gradient AC/A ratio. As the calculated AC/A ratio was higher, gradient AC/A ratio was lesser. Near gradient AC/A ratio was slightly higher than distance gradient AC/A ratio. Distance and near gradient AC/A ratio taken through the subjective -1.00 D were 1.30 $\Delta$/D and 1.68 $\Delta$/D(t-test. t=1.67, p < 0.001). Conclusions: There is negative correlation between calculated AC/A ratio and gradient AC/A ratio. Also, there is subtle difference between near gradient AC/A ratio and distance gradient AC/A ratio. Therefore, we need to measure distance gradient AC/A ratio when a practitioner prescribe glasses for a patient with distance exophoria.

Enhancement of Species-specific Attraction by Addition of a Minor Component of Sex Pheromone Gland of Grapholita dimorpha (복숭아순나방붙이 성페로몬샘의 미량성분 첨가에 따른 종특이적 유인력 증가 효과)

  • Jung, Chung Ryul;Kim, Seong-Ho;Kim, Yonggyun
    • Korean journal of applied entomology
    • /
    • v.53 no.3
    • /
    • pp.239-246
    • /
    • 2014
  • Two congener species of Grapholita molesta and G. dimorpha have similar host ranges and adult occurrence patterns. In addition, the two species commonly use cis-8-dodecenyl acetate (Z8-12:Ac) and trans-8-dodecenyl acetate (E8-12:Ac) as their major sex pheromone components. The commercial lures made of the two components, therefore, suffer a mixed attraction of these two species. This study was conducted to assess any effect of their known minor sex pheromone components to reduce the mixed attraction. When cis-8-tetradecenyl acetate (Z8-14:Ac) was added to the commercial sex pheromone consisting of Z8-12:Ac/E8-12:Ac = 85/15, the attraction to G. dimorpha was not affected, but its attraction to G. molesta was significantly reduced. However, the addition of either dodecanyl acetate (12:Ac) or tetradedecanyl acetate (14:Ac) did not influence on the attraction of both species to the commercial lure. The addition of E8-14:Ac to 3-component sex pheromone, Z8-12:Ac/E8-12:Ac/Z8-14:Ac = 85/15/10, the attraction to G. dimorpha was rather significantly suppressed. From these results, the 3-component sex pheromone, Z8-12:Ac/E8-12:Ac/Z8-14:Ac = 85/15/10 was suggested as an improved composition of sex pheromone lure for G. dimorpha.

Characteristic Analysis and Control of Three Phase PWM Buck AC-AC Converter (3상 PWM Buck AC-AC 컨버터의 특성해석과 제어)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1283-1290
    • /
    • 2003
  • Recently, PWM Buck AC-AC Converter is widely employed in various industrial applications such as voltage and power regulator, electronic transformer, phase shifter and so on. This paper presents static and dynamic modeling and complete characteristic analysis of a PWM Buck AC-AC converter. Firstly, the three phase converter system is modelled by using DQ transformation whereby we can obtain basic characteristic equations such as voltage gain and power factor as well as state equation and transfer function for control. Secondly, based on the analysis, the feedforward-feedback control technique is also proposed to obtain instantaneous duty level change whereby very fast dynamic response is achieved. Finally, the experimental results show the validity of the modeling, analysis and control.

Spectral Analysis of DC Link Ripple Currents in Three-Phase AC/DC/AC PWM Converters (3상 AC/DC/AC PWM 컨버터의 직류링크 리플전류의 주파수 영역 해석)

  • 이동춘;박영욱;석줄기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.244-252
    • /
    • 2002
  • In this paper, do link ripple currents for three-phase ac/dc/ac PWM converters feeding adjustable speed ac machine drives are analysed in a frequency domain. The expression of the harmonic currents is developed by using switching functions of the converter and exponential courier series expansion. The effect of the displacement angle between the switching Periods of line-side converters and motor-side inverters on the dc link ripple currents is Investigated. Also, the influence of asynchronization of PWM is observed. The result of analysis is compared with frequency spectrum which results from PSIM simulation. The proposed analysis technique is useful to understand the principles of P% and to derive an equivalent model of the dc link capacitors in a high frequency range.

Characteristic Analysis of Three Phase PWM Boost AC-AC Converter Using Circuit DQ Transformation (회로 DQ 변환을 이용한 3상 PWM Boost AC-AC 컨버터의 특성해석)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.7
    • /
    • pp.1514-1519
    • /
    • 2003
  • This paper presents modeling and analysis of static and dynamic characteristics in three phase PWM Boost AC-AC converter used for input voltage sag compensation of custom power. Especially, using circuit DQ transformation technique, an equivalent circuit in fundamental frequency domain is obtained which has all the system characteristics. Moreover, voltage gain and input power factor is analytically induced and linearized state equation at the specific operating point is given. Finally, PSIM simulation results show the validity of the Nosed modelling and analyses.

Characteristics Analysis of PWM SEPIC AC-AC Converter (3상 PWM SEPIC AC-AC 컨버터의 특성해석)

  • Choi Nam-Sup
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1158-1160
    • /
    • 2004
  • In this paper, a PWM SEPIC AC-AC converter for VVCF applications such as AC line conditioner, phase shifter is presented. The PWM SEPIC AC-AC converter is modelled by using complex circuit DQ transformation whereby the characteristics equations such as voltage gain and input power factor is analytically obtained. Finally, the PSIM simulation shows the validity of the modelling and analysis.

  • PDF

A Study on Implementing of AC-3 Decoding Algorithm Software (AC-3 Decoding Algorithm Software 구현에 관한 연구)

  • 이건욱;박인규
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1215-1218
    • /
    • 1998
  • 본 논문은 Digital Audio Compression(AC-3) Standard 인 A-52를 기반으로 하였으며 Borland C++3.1 Compiler를 사용하여 AC-3 Decoding Algorithm 구현하였다. Input Stream은 DVD VOB File에서 AC-3 Stream만을 분리하여 사용하며 최종 출력은 16 Bit PCM File이다. AC-3의 Frame구조는 Synchronization Information, Bit Stream Information, Audio Block, Auxiliary Data, Error Check로 구성된다. Aduio Block 은 모두 6개의 Block으로 나뉘어져 있다. BSI와 Side Information을 참조하여 Exponent를 추출하여 Exponent Strategy에 따라 Exponent를 복원한다. 복원된 Exponent 정보를 이용하여 Bit Allocation을 수행하여 각각의 Mantissa에 할당된 Bit수를 계산하고 Stream으로부터 Mantissa를 추출한다. Coupling Parameter를 참조하ㅕ Coupling Channel을 Original Channel로 복원시킨다. Stereo Mode에 대해서는 Rematrixing을 수행한다. Dynamic Range는 Mantissa와 Exponent의 Magnitude를 바꾸는 것으로 선택적으로 사용할 수 있다. Mantissa와 Exponent를 결합하여 Floating Point coefficient로 만든 후 Inverse Transform을 수행하면 PCM Data를 얻을 수 있다. PC에서 듣기 위해서는 Multi Channel을 Stereo나 Mono로 Downmix를 수행한다. 이렇게 만들어진 PCM data는 PCM Data를 재생하는 프로그램으로 재생할 수 있다.

  • PDF

A Quasi Z-Source AC-AC Converter with a Low DC Voltage Distribution Capability Operating as a Power Electronic Transformer (전력전자 변압기로 동작하는 저전압 직류배전 기능을 갖는 Quasi Z-소스 AC-AC 컨버터)

  • Yoo, Dae-Hyun;Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.358-366
    • /
    • 2014
  • This paper proposes a quasi Z-source AC-AC converter with the low DC voltage distribution capability operating as a power electronic transformer. The proposed system has configuration that the input terminals of two quasi Z-source AC-AC converters are connected in parallel, also their output terminal are connected in series. Simple control method of duty ratio was proposed for the in phase buck-boost AC voltage mode and the DC output voltage control. DSP based experiment and PSIM simulation were performed. As a result, the PSIM simulation results were same with the measured results. By controlling the duty ratio under the condition of 100 [${\Omega}$] load, quasi Z-source AC-AC converter could buck and boost the AC output voltage in phase with the AC input voltage, and the same time, the constant DC voltage could be output without affecting the AC output characteristics. And, the DC output voltage 48[V] was constantly controlled in dynamic state in case while the load is suddenly changed ($50[\Omega]{\rightarrow}100[\Omega]$). From the above result, we could know that the quasi Z-source AC-AC converter can act as a power electronic transformer with a low DC voltage distribution capability.

Adsorption Characteristics of Functionalized Activated Carbon for High Temperature CO2 Capture (고온 이산화탄소 포집을 위한 기능성 활성탄의 흡착특성)

  • Choi, Sung-Woo;Lee, Cheol-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.175-181
    • /
    • 2015
  • Activated carbon impregnated with polyethyleneimine (PEI) was evaluated as a functionalized adsorbent for $CO_2$ capture. The $CO_2$ adsorption characteristics of the adsorbents was undertaken using GC/TCD, BET surface area and FT-IR. A series of adsorbents were synthesized by impregnating 10, 30, 50 wt% of PEI on activated carbons and were investigated $CO_2$ adsorption capacity at high and low adsorption temperature. The $CO_2$ adsorption capacity at $20^{\circ}C$ and $100^{\circ}C$ was as follow: AC > PEI(10)-AC > PEI(30)-AC > PEI(50)-AC at $20^{\circ}C$ and PEI(10)-AC > PEI(30)-AC > PEI(50)-AC > AC at $100^{\circ}C$. Adsorption capacities of amine functionalized AC was lager than virgin AC at high temperature due to chemisorption by amino-group content. From the results, the PEI(10)-AC showed one of the most promising adsorbents for $CO_2$ capture from flue gas at high temperature.