• 제목/요약/키워드: AC voltage regulator

검색결과 53건 처리시간 0.016초

발전기 여자기시스템 주제어전원공급장치 국산화 개발 (The Development of EPSM(Exciter Power Supply Module) Localization in Generator Exciter(EX2100) System)

  • 이기선;박정철;추순남
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.101-107
    • /
    • 2016
  • The main target in this paper is the localization of VME Type EPSM in Generator Exciter(EX2100) System. Developed EPSM has the compatibility with the existing product in the structure and shape and electrical feature and so on, but it has a much improved capacity and reliability in comparison with origin company product. this paper, to improve these functions, put emphasis on protection, monitoring, power capacity increase(over 120%), an enlarged scale of input voltage supply, AC/DC dual voltage use and so on. After manufacturing product localization, it was carried out several tests for the performance and reliability verification of developed product. These tests were performed in Authorized Inspection Agency(KTL) and field application test and maker self-test were additionally performed. Finally, the results of all tests were "success".

디지털 제어 교류 전동기 구동시스템의 전류 측정 오차 해석 및 보상 (Analysis and Compensation of Current Measurement Error in Digitally Controlled AC Drives)

  • 송승호;최종우;설승기
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.462-473
    • /
    • 1999
  • 디지털 제어 방식으로 구동되는 모든 교류 전동기 벡터제어시스템의 근간을 이루는 전류 측정에 관한 문제를 다룬다. 일반적인 펄스폭 변조 방식 교류 전동기 구동 시스템에서 전동기 전류에 포함된 인버터 스위칭 노이즈를 없애기 위하여 저역 통과 필터를 사용하는데 이러한 필터는 필연적으로 측정된 신호의 시간 지연을 유발하게 된다. 따라서 샘플링한 전류값에는 기본파 성분 뿐만아니라 고조파 리플 성분이 포함된다. 본 논문에서는 3상 대칭 펄스폭 변조시 기준 전압 벡터의 위치에 다른 전류 샘플링 오차를 해석적으로 구하고 이러한 샘플링 오차를 최소화하기 위한 기법을 제안한다. 제안된 지연 보상 샘플링 기법을 사용하면 정상 상태 전류 측정 오차를 최소화할 수 있고 보다 정확한 토오크 제어가 가능하게 됨을 시뮬레이션과 실험을 통해 보였다.

  • PDF

가전용 커패시터의 소손원인 규명 및 발열 메커니즘 해석 (Examination of the Cause of Damage to Capacitors for Home Appliances and Analysis of the Heat Generation Mechanism)

  • 박형기;최충석
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.13-19
    • /
    • 2011
  • The purpose of this study is to examine the cause of damage to electrolytic capacitors and to present the heat generation mechanism in order to prevent the occurrence of similar problems. From the analysis results of electrolytic capacitors collected from accident sites, the fire causing area can be limited to the primary power supply for the initial accident. From the tests performed by applying overvoltage, surge, etc., it is thought that the fuse, varistor, etc., are not directly related to the accidents that occurred. The analysis of the characteristics using a switching regulator showed that the charge and discharge characteristics fell short of standard values. In addition, it is thought that heated electrolytic capacitors caused thermal stress to nearby resistances, elements, etc. It can be seen that the heat generation is governed by the over-ripple current, application of AC overvoltage, surge input, internal temperature increase, defective airtightness, etc. Therefore, when designing an electrolytic capacitor, it is necessary to comprehensively consider the correct polarity arrangement, appropriate voltage application, correct connection of equivalent series resistance(ESR) and equivalent series inductance(SEL), rapid charge and discharge control, sufficient margin of dielectric tangent, etc.