• Title/Summary/Keyword: AC source

Search Result 724, Processing Time 0.033 seconds

Breakdown Characteristics of Imitation Air under Uniform Fields and Non-Uniform (평등/불평등 전계 하에서의 제조공기(I-Air) 절연파괴특성)

  • Lee, Chang-Uk;Lee, Chang-Hun;Choi, Eun-Hyuck;Kim, Jung-Bae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1424-1425
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using niform fields(Sphere-Sphere electrode) and non-uniform fields(Needle-Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

Development of Education System and Modeling (교육용 시스템 개발과 모형화)

  • Park, Seong-Wook;Lee, Deuk-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2042-2044
    • /
    • 2001
  • The jumping ring apparatus of the type described in this study is used to demonstrate and educate the effects of electromagnetic induction. Placing an aluminum ring over the core and switching on AC source causes the ring to jump in the air due to induced currents in the ring producing a magnetic field opposed to that produced in the core. If the AC current is slowly increased from zero or ring is placed over the core when AC is already flowing the ring floats due to the balance between its weight and the upward electromagnetic force. Pentimum computer is used to display this value to screen and generate control signal.

  • PDF

Enhanced Voltage Gain Single-Phase Current-Fed qZ-Source Inverter (전압 이득이 향상된 단상 전류형 qZ-소스 인버터)

  • Shin, Hyun-Hak;Cha, Hon-Nyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.305-311
    • /
    • 2013
  • This paper proposes a performance improvement of existing single-phase current-fed qZ-Source inverter. Voltage gain of the traditional voltage-fed full-bridge inverter and single-phase current-fed qZ-source inverter is only equal to or smaller than input voltage. The proposed inverter can obtain twice higher voltage gain than the single-phase current-fed qZ-Source inverter by adding an extra switch and a capacitor in the circuit. In addition, the proposed inverter shares the common ground between dc input and ac output voltage. Therefore, the proposed inverter can eliminate the possible ground leakage current problem when it is used for grid-tied photovoltaic inverter system. A 120 W prototype inverter is built and tested to verify performances of the proposed inverter.

Static Stability Analysis Using Voltage Source Converter HVDC (전압형 컨버터 HVDC를 이용한 정적 안정도 해석)

  • Chae, Byung-Ha;Oh, Sae-Shung;Jang, Gil-Soo;Lee, Byung-Jun;Han, Byung-Mun;Cha, Jun-Min;Kim, Chan-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.66-68
    • /
    • 2004
  • The current source HVDC using thyristor valves requires the reactive power compensator, the increasement of short circuit ratio(SCR) by AC source, and the harmonic filter in power transmission. The voltage source HVDC that controls active power and reactive power independently can minimize the requirements and also can be used as a reactive power source without additional reactive power compensators. In this paper, the solution of supplying active power using direct current transmission and compensating additional reactive power at the heavy load zone in metropolitan area is proposed and verified by simulations.

  • PDF

Control of Three-Phase PWM Rectifiers Using Only DC-Side Sensors (직류측 센서만을 이용한 3상 PWM 정류기의 제어)

  • 이동춘
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.278-281
    • /
    • 2000
  • In this abstract a novel control scheme of voltage-source PWM rectifiers using only dc-side sensors is proposed. The phase currents are reconstructed from switching states of the rectifier and the dc output current. For effective current control the currents are estimated by a predictive state observer. Also both the phase angle and the magnitude of th source voltage are estimated by phase estimator and magnitude estimator respectively. The validity of the proposed ac sensorless technique is verified by experimental results.

  • PDF

Auxiliary Power Supply using Photovoltaic Power Generation for Air-Conditioner (태양광발전을 이용한 에어콘의 보조운전 제어 시스템)

  • 황인호;유권종;송진수;이후기;정찬규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.47-52
    • /
    • 1993
  • Recently, as exactly clean source, the research of photovoltaic power generation is undertaken actively and widely. In this paper, an auxiliary power supply system which is composed of photovoltaic generation and DC-DC boost chopper is described. This system in mainly for Air-conditioner appliances is which AC source is formed through rectifying circuit and without electrical storage battery. There exist two operating modes depending on the power quantity of the solar cells and the load. The control algorithm is discussed.

  • PDF

A HIGH VOLTAGE DC POWER SUPPLY SUITABLE FOR AN ION SOURCE

  • Nho, Eui-Cheol;Kim, In-Dong
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.436-441
    • /
    • 1998
  • This paper proposes an novel dc power supply using modified multilevel ac/dc converter. The output voltage of the power supply can be disconnected from and reapplied to the load rapidly. Therefore the power supply is suitable for a load having frequent short circuit such as ion source. The proposed scheme improves the performance, efficiency, and reliability and reduces the cost of the conventional power supply system for an ion beam acceleration.

  • PDF

A Syudy On DVR Control for Unbalanced Voltage Compensation (불평형 전압 보상을 위한 DVR 제어에 관한 연구)

  • Jung, Hong-Ju;Chung, Joon-Mo;Song, Jong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.218-221
    • /
    • 2001
  • This paper presents a new control scheme for a Dynamic Voltage Restorer(DVR) system consisting of series voltage source PWM converters. The control system is designed using differential controllers and digital filters to transfer the faulted ac source voltage to a d-q model and to separate the positive and negative sequence component for individual compensation. The performance of the presented controller and scheme are confirmed through simulation and actual experiment.

  • PDF

Compensate Voltage Drop for Autotransformer-Fed AC Electric Railroad System with Single-Phase STATCOM (STATCOM을 이용한 교류 전기철도 급전시스템의 전압강하 보상)

  • 정현수;이승혁;김진오
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.53-60
    • /
    • 2002
  • This paper presents exact autotransformer-fed AC electric railroad system modeling using constant current mode, and single-phase STATCOM(Static Synchronous Compensator) which has an effect on electric railroad system. An AC electric railroad is rapidly changing single-phase feeding electric power. To avoid voltage fluctuation under single phase loads, electric power should be received from a large source. The system modeling theory is based on the solution of algebraic. The AC electric railroad load model is nonlinear. Therefore this paper is considered nonlinear load using PSCAD/EMTDC. And the proposed modeling method is considered the line self-impedances and mutual-impedances that techniques for the AC electric railroad system modeling analysis, and that single-phase STATCOM can reliably compensate the voltage drop. In the case study, the allowance range of feeding voltage is 22.5∼27.5 kV, AT-fed AC electric railroad system circuit is analyzed by loop equation both normal and extension modes. The simulation objectives are to calculate the catenary and rail voltages with respect to ground, as the train moves along a section of line between two adjacent ATs. The results show that single-phase STATCOM can reduce the voltage drop in the feeding circuit and improve the power quality at AC electric railroad system by compensating the reactive power.

Analysis of Internal Energy Pulsation in MMC System According to Offset Voltage Injection with PWM Methods (PWM 방식을 이용한 옵셋 전압 주입에 따른 MMC 시스템 내부 에너지 맥동 분석)

  • Kim, Jae-Myeong;Jung, Jae-Jung
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1140-1149
    • /
    • 2019
  • In general, there are various pulse width modulation(PWM) methods simply using the offset voltage injection in voltage source converter(VSC). In accordance with the AC side voltage synthesis method with the offset voltage, DC side voltage utilization factor in VSC is changed. Also, this can apply equally to the MMC system. In other words, if the DC side capacity of the high voltage DC(HVDC) transmission system is determined, the maximum reactive power which can be supplied to the AC side can be changed according to the applied output voltage synthesis method with the offset voltage. In this paper, the leg energy pulsation in MMC system according to the AC side output voltage synthesis method with offset voltage which several representative PWM are applied to are mathematically analyzed and compared with each other. Finally, the above results are verified by simulation emulating the 400MVA full-scale MMC system to determine the consistency of the mathematical analysis.