• 제목/요약/키워드: AC resistance

검색결과 507건 처리시간 0.025초

알루미늄 스크랩을 이용하여 제작한 접지 전극의 전압-전류 특성 (I-V characteristics of ground electrode fabricated using an aluminium scrap)

  • 이우선;정용호;박진성
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권8호
    • /
    • pp.806-812
    • /
    • 1996
  • I-V characteristics of ground electrode fabricated using an aluminium scrap are presented. We fabricated several shapes of aluminium scraps and aluminium electrodes. The results show that the current of aluminium electrode increased linearly by the voltage increase. AC breakdown voltage of copper plate electrode was higher than that of aluminium electrode. AC breakdown current of aluminium electrode was higher than that of copper plate electrode. As applied voltage increased, grounding resistance of aluminum electrode decreased linearly.

  • PDF

고압회전기 절연진단 주기 설정에 관한 연구 (A Study on the Establishment of Insulation Diagnosis Cycle for High Voltage Rotating Machine)

  • 이영준;김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1939-1941
    • /
    • 2000
  • Nondestructive and destructuve insulation tests were performed the high voltage rotating machine in the local thermal power plants. Nondestructive tests include measurements of insulation resistance. polarization index, AC current. tan$\delta$, partial discharge. Destructive tests include measurements of AC hipot and DC hipot. This paper propose to establish the insulation diagnosis cycle for high voltage rotating machine.

  • PDF

Corrosion Characteristics of Reinforced Steel Bar Emedded in Multiple Mortar Specimen(W/C:0.5) Aged 5 Years in Seawater

  • Moon, Kyung-Man;Takeo, Oki;Won, Jong-Pil;Park, Dong-Hyun;Kim, Yun-Hae
    • International Journal of Ocean System Engineering
    • /
    • 제3권1호
    • /
    • pp.33-37
    • /
    • 2013
  • Reinforced concrete structures have been increasingly widely used in numerous industrial fields. These structures are often exposed to severely corrosive environments such as seawater, contaminated water, acid rain, and the seashore. Thus, the corrosion problems that occur with the steel bars embedded in concrete are very important from the safety and economic points of view. In this study, the effects of the cover thickness on the corrosion properties of reinforced steel bars embedded in multiple mortar test specimens immersed in seawater for 5 years were investigated using electrochemical methods such as the corrosion potentials, polarization curves, cyclic voltammograms, galvanostat, and potentiostat. The corrosion potentials shifted in the noble direction, and the value of the AC impedance also exhibited a higher value with increasing cover thickness. Furthermore, the polarization resistance increased with increasing cover thickness, which means that the oxide film that is deposited on the surface of a steel bar surrounded by alkali environment exhibits better corrosion resistance because the water, chloride ions and dissolved oxygen have difficulty penerating to the surface of the steel bar with increasing cover thickness. Consequently, it is considered that the corrosion resistance of reinforced steel can be improved by increasing the cover thickness. However, the corrosion resistance values of a steel bar estimated by measuring the corrosion potential, impedance and polarization resistance were not in good agreement with its corrosion resistance obtained by polarization curves.

역병과 세균성점무늬병에 복합저항성인 핵유전형 웅성불임성 고추 계통 육성을 위한 교배의 $F_3-F_4$세대 선발 (Selection in $F_3$ and $F_4$ Generations of a Cross for Breeding Genic Male Sterile Pepper Lines Resistant to Phytophthora Blight and Bacterial Spot)

  • 박동근;김병수
    • Current Research on Agriculture and Life Sciences
    • /
    • 제28권
    • /
    • pp.17-23
    • /
    • 2010
  • 역병(Phytophthora capsici)과 세균성점무늬병(Xanthomonas euvesicatoria)에 복합저항성인 핵유전형 웅성불임계(Genic male sterile line, GMS)를 육성하기 위하여 역병 저항성 핵유전형 웅성불임계에 역병-세균성점무늬병 복합저항성 계통을 교배하여 작성한 조합의 $F_3$$F_4$ 세대에 대하여 두 가지 병에 대한 저항성 선발을 실시하였다. 역병 저항성은 잘 알려져 있는 KC294(CM334)와 KC263(AC2258)에서 도입하고, 세균성점무늬병 저항성은 KC47(PI24467)에서 도입되었다. 역병에 고도의 저항성을 지닌 GMS 계통이 얻어졌으며, 이들은 세균성점무늬병에도 양적으로 저항성을 나타낼 것으로 기대된다.

  • PDF

고온초전도 선재의 과전류 통전 특성에 대한 피치의 영향 (Influence of pitch on over-current characteristics of HTS tapes)

  • 임성우;황시돌;최효상;김헤림;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.507-510
    • /
    • 2002
  • In economical points of view, AC loss of high temperature superconducting devices is considered as a serious problem that must be solved. Expecially, in case of HTS cables, HTS tapes are wound helically on the former to reduce AC loss. Critical characteristics of HTS tapes, however, are influenced by mechanical stress as well as electrical, temperature, and magnetical factors. The purpose of this study is to investigate the over current characteristics of HTS tapes given mechanical stress when they are wound on the former. We prepared HTS tapes with the pitch angle 20$^{\circ}$, length 25cm as well as tapes with pitch angle 0$^{\circ}$. When current of over 200A$\_$rms/ was applied, we found out that there are differences to the rate of resistance increase between the case of pitch angle 20$^{\circ}$and that of 0$^{\circ}$. The rate of resistance variation in HTS tapes of pitch angle 20$^{\circ}$increased more slowly than that of pitch angle 0$^{\circ}$. As a result, we concluded that if critical characteristics of HTS tapes are degraded by any external factor, when over current is applied, the current limiting characteristics in HTS tapes won't be able to be expected any more.

  • PDF

Load Resistance Influence of Magnetoelectric Characteristics on NiZnFe2O4+PZT Composites for Magnetoelectric Sensors

  • Ryu, Ji-Goo;Chung, Su-Tae
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.379-386
    • /
    • 2013
  • The influences of the load resistance $R_L$ on the magnetoelectric (ME) characteristics of $NiZnFe_2O_4+PZT$ composite were investigated in the non-resonance frequency range. The ME coefficient peak increases with increasing $R_L$, but the frequency indicating the ME coefficient peak decreases with increasing $R_L$. The maximum output power peak is approximately $9.3{\times}10^{-10}mW/Oe$ near $R_L=3.3M{\Omega}$ at f=280 Hz, and the ME coefficient seems to be saturated at $R_L>20M{\Omega}$. This frequency shift effect of $R_L$ shows that the frequency range for an ME sensor application can be modulated with the appropriate value of $R_L$. The ME output voltage has a good linear response to the ac field Hac and shows fair stability over a range of temperatures. The measured non-linearity of this sample is approximately 0.8%. This sample will allow for a low-strength magnetic ac-field sensor. The result from this sample will serve as basic data for a signal-processing circuit system.

시트르산의 양과 소결온도에 따른 (La,Sr)$MnO_3/Gd_{0.2}Ce_{0.8}O_{1.9}$ 계면특성 (Characterization of (La,Sr))$MnO_3/Gd_{0.2}Ce_{0.8}O_{1.9}$ Interface with Citric Acid Contents and Sintering Temperature)

  • 윤일영;윤희성;김병호
    • 한국전기전자재료학회논문지
    • /
    • 제11권1호
    • /
    • pp.18-25
    • /
    • 1998
  • G $d_{0.2}$C $e_{0.8}$ $O_{1.9}$(CGO) for electrolyte and L $a_{0.5}$S $r_{0.5}$Mn $O_3$(LSM50) for cathode in Solid Oxide Fuel Cells(SOFC) were synthesized by citrate process. Specimens were prepared with sintering temperatures at 110$0^{\circ}C$, 120$0^{\circ}C$ and 130$0^{\circ}C$, which were fabricated by slurry coating with citric acid contents. Interfacial resistance was measured between cathode and electrolyte using AC-impedance analyzer. With various citric acid content, the degree of agglomeration for the initial particles changed. Also sintering temperature changed the particle size and the degree of densification of cathode. Factors affecting the interfacial resistance were adherent degree of the electrolyte and cathode, distribution of TPB(three phase boundaries, TPB i.e., electrolyte/electrode/gas phase area) and porosity of cathode. By increasing the sintering temperature, particle size and densification of the cathode were increased. And then, TPB area which occurs catalytic reaction was reduced and so interfacial resistance was increased.sed.sed.d.

  • PDF