• 제목/요약/키워드: AC regeneration system

검색결과 26건 처리시간 0.028초

고조파 저감 능력을 가진 회생용 인버터 시스템 연구 (A study of regenerative inverter system with capability of harmonic reduction)

  • 최창열;배창환;장수진;송상훈;원충연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.443-448
    • /
    • 2005
  • This paper proposed a regeneration inverter system, which can regenerate the excessive power form dc bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are include to ac current source. The regenerative inverter is operated as two modes. As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In the paper, a regeneration inverter used PWM DC/AC converter algorithm. And an active power filter used p-q theory. The simulation was composed as a prototype model[3kW]. Simulation results show that two algorithm can be used to real model[100kW]. Finally, the inverter was successfully operated as regeneration mode.

  • PDF

능동전력필터를 가진 지하철 회생인버터 시스템 (A Regeneration Inverter for Traction Applications with a Active Power Filter)

  • 원충연;장수진;김연충;이병국;배창한;김용기
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.25-32
    • /
    • 2006
  • 본 논문에서는 전철시스템의 직류모선에 발생하는 잉여분의 전력을 교류전원 측으로 회생시킬 수 있는 회생인버터시스템을 제안한다. 제안된 직류 전철용 회생인버터 시스템은 교류 전원 측 전류에 포함되어진 고조파를 제거할 수 있는 기능을 추가하였다. 회생인버터 모드에서는 전철의 감속에 의해 회생되는 에너지를 재사용할 수 있으며, 능동전력필터 모드에서는 정류기에 의해 발생되는 고조파 왜곡을 보상할 수 있다. 논문에서 회생용 인버터는 PWM DC/AC 인버터 알고리즘을 사용하였으며, 능동전력필터는 p-q 이론을 사용하였다. 시뮬레이션은 축소모델[3.7kW]과 동일하게 구성되었다. 시뮬레이션과 실험 결과로부터 두 가지 알고리즘이 실 모델[100kW]에서도 적용되어질 수 있음을 증명하였다.

A 15kW Grid-Connected Battery Charging and Discharging System with AC Regeneration Function

  • Youn, Sun-Jae;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.491-493
    • /
    • 2011
  • In this paper, a 15kW grid-connected battery charging and discharging system was proposed. AC regenerative device which consisted of an inverter using IGBTs and LCL filter transferred surplus power to grid. Phase locked loop(PLL) was used to resolve three-phase unbalance. AC regeneration function is able to improve the rate of energy use and the cost savings of energy is expected.

  • PDF

직류 지하철 급전시스템용 회생인버터 시스템 (Regeneration inverter system for DC traction system)

  • 조기현;장수진;김종윤;원충연;김용기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.28-32
    • /
    • 2007
  • In this paper, a unified regenerative inverter and control algorithm are proposed in order to perform regenerative action and active power filter action. While the regenerative mode of traction, it works as regenerative inverter to reduce a excessive power of DC bus line and the powering mode of the traction, it works as active power filter to compensate ac current distortion, power factor, and voltage unbalance. In the paper, a regeneration inverter used PWM DC/AC inverter algorithm. And an active power filter used p-q theory. We are carrying out a mode analysis of DC traction system similar to actual system with MG-set and experimenting with prototype model. Through the simulation and experiment, we were proving the regeneration inverter operation which suggested in this paper.

  • PDF

3상 PWM 컨버터의 모델링 및 해석 (Modeling and Analysis of Three Phase PWM Converter)

  • 조국춘;박채운;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.328-335
    • /
    • 1999
  • Three phase full bridge rectifier has been used to obtain dc voltage from three phase ac voltage source. The rectifier system has drawbacks that power factor is low and power flow is unidirectional. Therefore, when dc voltage increases due to regeneration of power the dynamic resister for dissipation of regeneration power must be installed. But three phase PWM converter can be controlled to operate with unity power factor and bidirectional power flow. Therefore when the PWM converter is used as do supply system, the dissipating resistor is not necessary. On this thesis, in order to design a controller having good performance, the hee phase PWM converter is completely modeled by using circuit DQ-transformation and thus a general and simple instructive equivalent circuit is obtained; the inductor set becomes a second order gyrator-coupled system and three phase inverter becomes a transformer as well. Under given phase angle(${\alpha}$) and modulation index(MI) of the three phase inverter, the dc and ac characteristics are obtained by analysis of the transformed equivalent circuit The validity of the equivalent circuit is confirmed through PSPICE simulation. And based on the dc and ac characteristics a controller with unity power factor is proposed.

  • PDF

능동전력필터 기능이 추가된 지하철 회생 전력 제어용 인버터에 관한 연구 (A Study on Inverter for DC Traction Regenerative Power Control with Active Power Filter Ability)

  • 최창열;배창환;장수진;송상훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.463-465
    • /
    • 2005
  • This paper proposes a regeneration inverter system, which can regenerate the excessive power form the DC bus line to the AC source for traction systems. The proposed regeneration inverter system for DC traction can reduce harmonics which is a characteristic of the AC current source. The simulation was composed as a prototype model[3.7kW]. Finally, it is shown that the inverter can successfully operate in regeneration mode.

  • PDF

옥수수 전이인자 Ac가 도입된 연초조직의 재분화 (Regeneration of Tobacco Tissue Introduced with the Maize Transposable Element Activator)

  • 박성원;최광태;박지창;김영진
    • 한국연초학회지
    • /
    • 제13권2호
    • /
    • pp.34-41
    • /
    • 1991
  • To explore the possibility of introducing Zea mays transposable element Ac(activator) which can be used as a mutagen and gene tag in tobacco plants other than maitre, we tried to introduce a cloned Ac element into tobacco cells by an Agrobacterium tumefaciens binary vector system. Transformation of N. babacum cv. Burley 21 tissues and regeneration to whole plant were carried out. The frequency of the transformed callus induced in shoot induction media was higher than that of transformed callus induced in callus induction media. However, the calli were not grown in the second selection media, and became yellow senescent calli. Regenerated tobacco plantlets with foreign gene were also obtained in shoot induction media containing 100 $\mu\textrm{g}$/ml kanamycin and 100$\mu\textrm{g}$/ml carbenicillin. The leaf tissues of transformant was also resistant to 1000 $\mu\textrm{g}$/ml kanamycin. The chromosomal DNAs of transformant and normal plant of N. tabacum were digested by EcoR I and Hind III but not by Pst I.

  • PDF

Ac/Ds-mediated gene tagging system in rice

  • Eun, Moo-Young;Yun, Doh-Won;Nam, Min-Hee;Yi, Gi-Hwan;Han, Chang-Deok;Kim, Doh-Hoon;Park, Woong-June;Kim, Cheol-Soo;Park, Soon-Ki
    • 한국식물생명공학회:학술대회논문집
    • /
    • 한국식물생명공학회 2005년도 추계학술대회 및 한일 식물생명공학 심포지엄
    • /
    • pp.95-105
    • /
    • 2005
  • Transposon-mediated insertional mutagenesis provides one of the most powerful tools for functional studies of genes in higher plants. This project has been performed to develop a large population of insertional mutations, and to construct databases of molecular information on Ds insertion sites in rice. Ultimate goals are to supply genetic materials and information to analyze gene function and to identify and utilize agronomically important genes for breeding purpose. Two strategies have been employed to generate the large scale of transposon population in a Japonica type rice, Dongjin Byeo; 1) genetic crosses between Ac and Ds lines and 2) plant regeneration from seeds carrying Ac and Ds. Our study showed that over 70% of regenerated plants generally carried independent Ds elements and high activity of transposition was detected only during regeneration period. Ds-flanking DNA amplified from leaf tissues of F2 and T1 (or T2) plants have been amplified via TAIL-PCR and directly sequenced. So far, over 65,000 Ds lines have been generated and over 9,500 Ds loci have been mapped on chromosomes by sequence analysis. Database of molecular information on Ds insertion sites has been constructed, and has been opened to the public and will be updated soon at http://www.niab.go.kr. Detailed functional analysis of more than 30 rice mutants has been performed. Several Ds-tagged rice genes that have been selected for functional analysis will be briefly introduced. We expect that a great deal of information and genetic resources of Ds lines would be obtained during the course of this project, which will be shared with domestic and international rice researchers. In addition to the Japonica rice, we have established the tagging system in an rice line of indica genetic background, MGRI079. MGRI079 (Indica/Japonica) was transformed with Agrobacteria carrying Ac and Ds T-DNA vectors. Among transgenic lines, we successfully identified single-copy Ds and Ac lines in MGR1079. These lines were served as ‘starter lines’ to mutagenize Indica genetic background. To achieve rapid, large scale generation of Ds transposant lines, MGR1079 transformants carrying homozygous Ac were crossed with ones with homozygous Ds, and $F_2$seeds were used for plant regeneration. In this year, over 2,000 regeneration plants were grown in the field. We are able to evaluate the tagging efficiency in the Indica genetic background in the fall.

  • PDF

AC 회생이 가능한 배터리 충·방전 테스트 시스템 (AC Regeneratable Battery Charging and Discharging Test System)

  • 김준구;윤선재;김재형;원충연;나종국
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.99-106
    • /
    • 2012
  • In this paper, 15[kW] AC regenerative system for battery charging and discharging test is proposed. The regenerative system is able to regenerate surplus energy to the grid in discharging mode, and the inverter of the system can be operated as a converter to compensate scarce energy in charging mode. In case of the conventional DC charging and discharging system, the regenerative energy is consumed by a resistor. However, as the proposed system regenerates the surplus energy to the grid through using DC-AC inverter, the energy saving effect can be achieved. In this paper, 15[kW] battery charging and discharging system is developed, and the validity of the system is verified through simulation and experimental results.

직류전철용 전력공급 장치의 에너지희생에 관한 연구 (A study on energy regeneration of power supply for DC electric traction system)

  • 방효진;장수진;송상훈;원충연;김용기;안규복
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.439-442
    • /
    • 2004
  • This paper described a dc power system, which can generate the excessive do power form do bus line to ac source in substation for traction system. The proposed regeneration inverter system for dc traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation.

  • PDF