• 제목/요약/키워드: AC dielectric constant

검색결과 55건 처리시간 0.018초

배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발 (Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application)

  • 박동근;석복열;고태국;강형구
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

SBT 강유전체 충전층 저온 플라즈마 반응기의 전기적 특성, 오존생성 및 휘발성유기화합물의 분해 (Characteristics of Electrical Properties, Ozone Generation and Decomposition of Volatile Organic Compounds by Nonthermal Plasma Reactor Packed with SBT Ferroelectric)

  • 어준;김일원;박진도;이주영;이학성
    • 공업화학
    • /
    • 제22권3호
    • /
    • pp.249-254
    • /
    • 2011
  • Ferroelectric의 강유전체 소구들을 충전한 원통형의 비열 방전 플라즈마 반응기를 설계 제작하였으며, 강유전체 층방전 구조를 구성하는 평판(20 mm 간격) 금속망 전극 사이에 직경 2.0 mm인 $SrBiTaO_9$ (SBT) 소구들을 위치시키고 고압의 교류 전원을 인가하였다. SBT 소구는 상온($25^{\circ}C$)에서 150, 큐리온도($335^{\circ}C$)에서 500의 유전상수를 가졌다. 플라즈마 반응기에서 오존 생성속도는 거의 인가전압의 증가에 비례하였으며, SBT 소구들이 충전된 경우, 20 kV 이상의 인가전압에서 오존 생성속도는 급격하게 증가하였다. 부코로나 방전에서 오존 생성속도가 정코로나 방전에서의 경우보다 높았다. 그러나 톨루엔 및 메틸렌클로라이드의 분해율은 생성된 오존 농도에 비례하여 증가하지 않았다.

Design Guidelines for a Capacitive Wireless Power Transfer System with Input/Output Matching Transformers

  • Choi, Sung-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1656-1663
    • /
    • 2016
  • A capacitive wireless power transfer (C-WPT) system uses an electric field to transmit power through a physical isolation barrier which forms a pair of ac link capacitors between the metal plates. However, the physical dimension and low dielectric constant of the interface medium severely limit the effective link capacitance to a level comparable to the main switch output capacitance of the transmitting circuit, which thus narrows the soft-switching range in the light load condition. Moreover, by fundamental limit analysis, it can be proved that such a low link capacitance increases operating frequency and capacitor voltage stress in the full load condition. In order to handle these problems, this paper investigates optimal design of double matching transformer networks for C-WPT. Using mathematical analysis with fundamental harmonic approximation, a design guideline is presented to avoid unnecessarily high frequency operation, to suppress the voltage stress on the link capacitors, and to achieve wide ZVS range even with low link capacitance. Simulation and hardware implementation are performed on a 5-W prototype system equipped with a 256-pF link capacitance and a 200-pF switch output capacitance. Results show that the proposed scheme ensures zero-voltage-switching from full load to 10% load, and the switching frequency and the link capacitor voltage stress are kept below 250 kHz and 452 V, respectively, in the full load condition.

$Bi_2O_3$치환에 따른 $(Pb_{1-2x/3}Bi_x)[(Ni_{1/3}Nb_{2/3})_{0.4}(Ti_{0.6}Zr_{0.4})_{0.6}]O_3$ 세라믹스의 압전 및 전계유기 왜형 특성 (Piezoelectric and Electro-induced Strain Properties of $(Pb_{1-2x/3}Bi_x)[(Ni_{1/3}Nb_{2/3})_{0.4}(Ti_{0.6}Zr_{0.4})_{0.6}]O_3$Ceramics with the Substitution of $Bi_2O_3$)

  • 윤현상;정회승;임인호;윤광희;김준한;박창엽
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권5호
    • /
    • pp.434-439
    • /
    • 1997
  • It this paper, the piezoelectric and electro-induced strain properties of (P $b_{1-}$2x/3/B $i_{x}$ )[N $i_{1}$3/N $b_{2}$3/)$_{0.4}$( $Ti_{0.6}$Z $r_{0.4}$)$_{0.6}$] $O_3$ceramics (x=0, 0.005, 0.02) were investigated with the substitution of B $i^{3+}$, and the feasibility of the application for bimorph actuator was evaluated by measuring the dynamic properties of the piezoelectric bimorph fabricated with above ceramics. Dielectric constant was enhanced with the increase of B $i^{3+}$ substitution, and appeared the maximum value of 5032 at x=0.01 composition. Increasing the substitution of B $i^{3+}$, the electromechanical coefficient( $k_{p}$ , $k_{31}$ ) was increased up to the substitution of 0.5 mol% B $i^{3+}$, showed the value of 0.656, 0.439, respectively. The piezoelectric constant( $d_{33}$ $d_{31}$ ) had the highest value of 344, 825 with the substitution of 0.5 mol% B $i^{3+}$. The strain, generated by 60 Hz AC electric field, had the largest value of 1200($\times$10$^{-6}$ $\Delta$1/1) in the composition with the substitution of 0.5 mol% B $i^{3+}$. The dynamic properties of the bimorph actuator, fabricated with the composition substitution of 0.5 mol% B $i^{3+}$, showed the largest value of 325 $\mu$m at $\pm$150 V square pulse. square pulse.are pulse..

  • PDF

퍼콜레이션 이론에 기초한 복합재료의 복소 유전율 모델에 대한 연구 (Study on the numerical model of complex permittivity of composites based on the percolation theory)

  • 김진봉;이상관;김천곤
    • Composites Research
    • /
    • 제22권3호
    • /
    • pp.44-54
    • /
    • 2009
  • 본 논문에서는 퍼콜레이션 이론적 관점에 기초한 복소 유전율의 수치모델을 제시하고, 전기 전도성이 뛰어난 카본 블랙을 혼합한 유리섬유/에폭시 복합재료 적층판의 복소 유전율을 이용하여 이 깃을 검증하였다. 제시된 모델은 카본 블랙의 함유율이 퍼콜레이션 임계함유율 보다 높고, 주파수가 충분히 높아서 복합재료의 교류 전기전도도가 주파수에 비례하는 구간에서의 복소 유전율을 모사한다. 복합재료의 복소 유전율은 벡터회로망분석기와 7 mm 동축관을 이용하여 $0.5\;GHz\;{\sim}18\;GHz$ 대역에서 측정되었다. 제시된 모델은 퍼콜레이션 이론에서 유용하게 사용되는 축척(눈금잡이) 법칙의 함수형태와 실험을 통하여 구한 상수들로 구성되어 있으며, 복소 유전율을 주파수와 가본 블랙의 함유율의 함수로 나타내었다. 제시된 모델은 복소 유전율을 측정결과와의 비교를 통하여 검증되었다.