• 제목/요약/키워드: AC breakdown test

검색결과 98건 처리시간 0.029초

고온 초전도 레이블의 절연 특성 (Insulation Characteristics of High Temperature Superconducting Cable)

  • 김해준;김재호;심기덕;김해종;조전욱;성기철;곽동순;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.244-247
    • /
    • 2004
  • The electrical insulating design is important to realize a HTS power cable because the cable is operated under the high voltage environment. For the insulation design of a HTS power cable, it is necessary to investigate the AC, impulse breakdown and partial discharge(PD) inception stress of liquid nitrogen/LPP composite insulation system. Based on these results, the electrical insulation of a HTS power cable is designed and Mini-model cables are manufactured. The manufactured Mini-model cables are evaluated that AC, impulse withstand voltage, breakdown and partial discharge inception stress and analyzed characteristics insulation of HTS cable bending condition according to this paper. From these tests, the AC, impulse withstand voltage test and partial discharge inception stress is satisfied "standard technical specification of KEPCO" in Korea and the breakdown voltage was 120kV.

  • PDF

평등전계에서 SF6/CF4 혼합가스의 AC절연내력 특성 (AC Breakdown Voltage Characteristics of SF6/CF4 in Uniform field)

  • 황청호;박신우;김남렬;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제20권4호
    • /
    • pp.381-387
    • /
    • 2007
  • The excellent dielectric properties of $SF_6$(sulfur hexafluoride) have lead to its wide range of application in the field of high voltage insulation. Because there has been some recent concern regarding the environmental impacts of $SF_6$ binary gas mixtures, with $SF_6$ as the main component, have been the subject of active research. Scientists have long been interested in the possible use of gaseous fluorocarbons, including $CF_4$ (Carton Tetrafluoride), in high voltage applications due to their inert character and high dielectric strength. This paper presents experimental results concerning the AC breakdown characteristics lot various mixtures of $SF_6/CF_4$ in a test chamber and 25.8 kV GIS (Gas Insulation Switchgear) at practical pressures (0.1-04 MPa) and gap lengths (0.5 mm, 1 mm) in a test chamber. In the result, it was observed that an increase in the dielectric strength is attained through the addition of $SF_6$ to $CF_4$. It is possible to make an environment friendly gas insulation material while maintaining the dielectric strength by combing $SF_6$ and $CF_4$ which generates a lower level of the "global warming" effect.

자켓 컴팍운드용 절연재의 수증기투과 및 절연파괴 특성 (Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound)

  • 송재주;한재홍;송일근;한용희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB(Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE> LLDPE = MDP E> LDPE and WVT ratio was HDPE

  • PDF

4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준 (Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings)

  • 김희동
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

Breakdown Characteristics and Survival Probability of Turn-to- Turn Models for a HTS Transformer

  • Cheon H.G.;Baek S.M.;Seong K.C.;Kim H.J.;Kim S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권2호
    • /
    • pp.21-26
    • /
    • 2005
  • Breakdown characteristics and survival probability of turn-to-turn models were investigated under ac and impulse voltage at 77K. For experiments, two test electrode models were fabricated: One is point contact model and the other is surface contact model. Both are made of copper wrapped by O.025mm thick polyimide film(Kapton). The experimental results were analyzed statistically using Weibull distribution in order to examine the wrapping number effects on voltage-time characteristics under ac voltage as well as under impulse voltage in LN$_{2}$. Also survival analysis were performed according to the Kaplan-Meier method. The breakdown voltages of surface contact model are lower than that of point contact model, because the contact area of surface contact model is wider than that of point contact model. Besides, the shape parameter of point contact model is a little bit larger than that of surface contact model. The time to breakdown t$_{50}$ is decreased as the applied voltage is increased, and the lifetime indices slightly are increased as the number of layers is increased. According to the increasing applied voltage and decreasing wrapping number, the survival probability is increased.

Statistical Analysis of Electrical Tree Inception Voltage, Breakdown Voltage and Tree Breakdown Time Data of Unsaturated Polyester Resin

  • Ahmad, Mohd Hafizi;Bashir, Nouruddeen;Ahmad, Hussein;Piah, Mohamed Afendi Mohamed;Abdul-Malek, Zulkurnain;Yusof, Fadhilah
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.840-849
    • /
    • 2013
  • This paper presents a statistical approach to analyze electrical tree inception voltage, electrical tree breakdown voltage and tree breakdown time of unsaturated polyester resin subjected to AC voltage. The aim of this work was to show that Weibull and lognormal distribution may not be the most suitable distributions for analysis of electrical treeing data. In this paper, an investigation of statistical distributions of electrical tree inception voltage, electrical tree breakdown voltage and breakdown time data was performed on 108 leaf-like specimen samples. Revelations from the test results showed that Johnson SB distribution is the best fit for electrical tree inception voltage and tree breakdown time data while electrical tree breakdown voltage data is best suited with Wakeby distribution. The fitting step was performed by means of Anderson-Darling (AD) Goodness-of-fit test (GOF). Based on the fitting results of tree inception voltage, tree breakdown time and tree breakdown voltage data, Johnson SB and Wakeby exhibit the lowest error value respectively compared to Weibull and lognormal.

The Effect of Butt gaps on Dielectric Strength of Taped Insulation in Superconducting Cable

  • Andreev, Alexander-M;Kim, Soo-Yeon;Lee, In-Ho;Kim, Do-Woon;Shin, Doo-Sung
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.128-132
    • /
    • 2003
  • This paper discusses several electrical properties of tape-type insulation impregnated with liquid nitrogen ($LN_2$) in superconducting cable. Synthetic polypropylene laminated paper has been tested for its short-term breakdown strength and partial discharge(PD) characteristics under AC voltage. furthermore, the effect of winding parameter on breakdown strength, PD incepti on and extinction electrical stress with different test samples are discussed.

UHF센서를 이용한 가스절연송전선로 절연파괴 위치 추정에 관한 연구 (A Study on Estimation of Breakdown Location using UHF Sensors for Gas Insulated Transmission Lines)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.805-810
    • /
    • 2011
  • This paper deals with the method and algorithm used to find fault locations in gas insulated transmission line. The method uses UHF sensors and digital oscilloscope to detect discharge signals emitted to the outside through insulating spacer in the event of breakdown inside GIL. UHF sensors are the external type and installed at outside of insulating spacers of GIL. And we used wavelet signal processing to analyze the discharge signals and confirm the exact fault location findings in the GIL test line. This method can overcome demerit of TDR(Time Domain Reflectometer) method having been applied to detect fault location for conventional underground transmission lines, and Ground Fault Sensors used in conventional GIS systems. TDR method requires high level of specialty and experience in analyzing the measured signals. Ground fault sensors are installed inside GIL and can be destroyed by high transient voltage. This paper's method can simplify the fault location process and minimize the damage of sensors. In addition, this method can estimate the fault location only by the time difference when discharge signals are arrived to detecting sensors at the ends of GIL sections without reasons of breakdown. To test the performance of our method, we installed sensors at the ends of test line of GIL(84m) and sensed discharge signals occurred in GIL, energized with AC voltage generator up to 700kV.

고압전동기 고정자 권선의 절연파괴 특성 (Characteristics of Insulation Failure in High Voltage Motor Stator Windings)

  • 김희동;김경열;박덕현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.124-124
    • /
    • 2010
  • Diagnostic tests were performed on six high voltage motors. These tests included ac current, dissipation factor(tan6) and partial discharge(PD) magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 and No.2 motors(4.16 kV) failed near rated voltage of 12.3 kV and 14.2 kV, respectively. The breakdown voltage of No.3 and No.4 motors(6.6 kV) was 17.6 kV and 17.8 kV, respectively. These motors are higher that expected for good quality coils in 6.6 kV class motors.

  • PDF

한국전력에서 활선작업시 착용하는 절연복 개발 (The Development of Insulating Jackets for protection of Live-line workers in KEPCO)

  • 유호근;김우성;이재영;조계철;안철경;최명호;김상기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.388-389
    • /
    • 2007
  • Objective of the study is development of 23kV insulating jackets for protection of workers from electrical shock. The breakdown voltage of Ethylene-VinylAcetate copolymers(EVA) films in insulating oil were measured. Insulating jackets were made by the high frequency welding machine, and withstanding voltage test of these were measured. For breakdown voltage at AC 30kV, the number of EVA film with $105{\pm}5{\mu}m$ thickness was 4$\sim$5pieces. When AC 30kV during 3 minutes supplied on the insulating jackets, those were keep on the good quality.

  • PDF