• Title/Summary/Keyword: AC Measurement Standard

Search Result 41, Processing Time 0.033 seconds

Cutting Force Regulation in Milling Process Using Sliding Mode Control (슬라이딩 모드 제어기를 이용한 밀링공정의 절삭력 제어)

  • Lee, Sang-Jo;Lee, Yong-Seok;Go, Jeong-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.8
    • /
    • pp.1173-1182
    • /
    • 2001
  • Recent noticeable advances of CNC machine tools have considerably improved productivity and precision in manufacturing processes. However, in the respect of productivity some defects still remain because selection of machining conditions entirely depends on the experiences of programmers. Usually, machining conditions such as feed rate and spindle speed have been selected conservatively by considering the worst cases, and it has brought the loss of machining efficiency. Thus, the improvement of cutting force controller has been done to regulate cutting force constantly and to maximize feedrate simultaneously in case that machining conditions change variously. In this study, sliding mode control with boundary layer is applied to milling process for cutting force regulation and in a commercial CNC machining center data transfer between PC and PMC (programmable machine controller) of CNC machine is done using a standard interface method. And in the cutting force measurement, an indirect cutting force measuring system using current signal of AC servo is adopted in order not to use high-priced equipment like tool dynamometer. The purpose of this study is to maximize the productivity in milling process, thus its results can be applied to cases such as rough cutting process.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

Catalytic Spectrophotometry for the Determination of Manganese at Trace Levels by a Novel Indicator Reaction (새로운 지시약 반응에 의해 극미량 수준의 망간 측정을 위한 촉매 반응의 분광 광도 측정법)

  • Gurkan, Ramazan;Caylak, Osman
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.5
    • /
    • pp.556-566
    • /
    • 2010
  • A new kinetic spectrophotometric method is developed for the measurement of Mn(II) in natural water samples. The method is based on the catalytic effect of Mn(II) with the oxidation of Gallocyanin by $KIO_4$ using nitrilotriacetic acid (NTA) as an activation reagent at 620 nm. The optimum conditions obtained are $4.00{\times}1^{-5}\;M$ Gallocyanin, $KIO_4$, $1.00{\times}10^{-4}\;M$ NTA, 0.1 M HAc/NaAc buffer of pH = 3.50, the reaction time of 5 min and the temperature of $30^{\circ}C$. Under the optimum conditions, the proposed method allows the measurement of Mn(II) in a range of $0.1\;-\;4.0\;ng\;mL^{-1}$ and with a detection limit of down to $0.025\;ng\;mL^{-1}$. The recovery efficiency in measuring the standard Mn(II) solution is in a range of 98.5 - 102%, and the RSD is in a range of 0.76 - 1.25%. The newly developed kinetic method has been successfully applied to the measurement of Mn(II) in both some environmental water samples and certified standard reference river water sample, JAC-0031 with satisfying results. Moreover, few cations and anions interfere with the measurement of Mn(II). Compared with the other catalytic-kinetic methods and instrumental methods, the proposed kinetic method shows fairly good selectivity and sensitivity, low cost, cheapness, low detection limit and rapidity. It can easily and successfully be applied to the real water samples with relatively low salt content and complex matrices such as bottled drinking water, cold and hot spring waters, lake water, river water samples.

Study on the Ego states and Coping Style of Nursing Students (간호대학생의 자아상태와 대응양상과의 관계 연구)

  • Won, Jeong-Sook
    • Women's Health Nursing
    • /
    • v.8 no.4
    • /
    • pp.608-618
    • /
    • 2002
  • The purpose of this study is to analyze the type of ego states and stress coping style on female college students who are in the course of nursing study. This study is performed in the view of Transactional Analysis and designed to scrutinize descriptive correlations between the type of ego states and stress coping style. The subject is consists of 144 freshmen and sophomore, 138 junior and senior students group, who are students of K nursing college located in Seoul. The sampling investigation period is on Sept. 14, 2002 to Oct. 26, 2002. The measuring instrument used for Transactional Analysis ego state is 50 items Ego-gram research paper devised by Dusay(1997). For studying coping style, Folkman & Lazarus's measurement(1984) was adopted, which is translated and modified by Han, and Oh,(1990). Statistic average and standard deviation were generated by using SPSS PC+, t-test and Pearson correlation. The results were as follows: 1) In the type of ego states on both groups(lower group : freshmen, sophomore upper group : junior, senior) indicated the arithmetic apex NP(maximum value), then the point A was high and the data made a down slope to point AC. In the comparison to type of ego states between two groups, only at point CP, the data value of upper year students represented higher than that of lower year ones by C(t=2.28, p=.023). In the psychological energy level of ego states, both groups indicated average level.2) Stress coping style of whole students were highly and affirmatively dedicated to research. Consecutive consequences follow like this(high to low) : the central point of problem, search for social support, hopeful aspect and indifference. Especially hopeful aspect(t=.67, p=.05), relaxation of tension(t=-2.16, p=.03) made significant difference each other in the view of arithmetic calculation 3) While verifying coping style in terms of ego states level between lower and upper students group, In type CP, high level ego states group indicated significant difference on stress coping style area than low leveled group and made such sequences as the central point of problem, hopeful aspect, search for social support, positive interest and relaxation of tension. In type NP, sequences such as the central point of problem, search for social support, positive interest and relaxation of tension were emerged with little differences. In type A, the central point of problem, positive interest and relaxation of tension. In type FC, hopeful aspect, search for social support, positive interest and relaxation of tension. In type AC, hopeful aspect and indifference were derived significantly different(p<.05). 4) In the aspect of relation between ego states and coping style, type CP presented the central point of problem and relaxation of tension, type NP presented positive interest, search for social support and the central point of problem, type A showed the central point of problem, positive interest and relaxation of tension, type FC showed relaxation of tension, positive interest, search for social support, indifference and the central point of problem, type AC showed hopeful aspect, indifference and the central point of problem. All the sequence shown above had high-to-low procedure and represented static relations each other(p<.05).

  • PDF

Ordering of manganese spins in photoconducting $Zn_{1-x}Mn_xTe$

  • Kajitani, T.;Kamiya, T.;Sato, K.;Shamoto, S.;Ono, Y.;Sato, T.;Oka, Y.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.06a
    • /
    • pp.39-43
    • /
    • 1998
  • Single crystals of{{{{ { Zn}_{ 1-x} {Mn }_{x }{Te} }}}} with x=0.3-0.6 were prepared by the standard Bridgeman method. Diffuse neutron diffraction intensities due to the short range magnetic ordering is found in the vicinities of 1 1/2 0 reciprocal point and its equivalent point, indicating that the magnetic correlation of the clusters is the type III antiferromangetic one do the F-type Bravais class crystals, being identical with that of {{{{{ Cd}_{ 1-x} {Mn }_{x }Te }}}}. Neutron inelastic scattering measure-ment has been performed for {{{{{ Zn}_{ 0.6} { Mn}_{ 0.4}Te }}}} sample using the cold neutron spectrometer. AGNES. High resolution measurement with the energy resolution of {{{{ TRIANGLE E= +- .01meV}}}} was carried out in the temperature range from 10K to the ambient. Critical scattering, closely related with the spin glass transition, has been observed for the first time in this semimagnetic semi-conductor. The critical scattering is observed at temperatures in the vicinity of the spin glass transition temperature, 17K. The scattering is observed as a kind of quasielastic scattering in the reciprocal range where the elastic magnetic diffuse scattering has been observed, e.g., 11/20 reciprocal point, indicating the spin fluctuation has dynamic components in this material. Photoconductivity has been discovered below 150K in {{{{{ Zn}_{ 0.4} {Mn }_{0.6 } Te}}}}. The electric AC conductivity has been increased dramatically under the laser light with the wave lengths of {{{{ lambda =6328,5145 and4880 }}}}$\AA$ ,respectively. After the light was darkened, the conductivity was reduced to the original level after about 2000 seconds at 50K, being above the spin glass transition temperature. This phenomenon is the typical persistent photoconductivity; PPC which was similarly found in {{{{ { Zn}_{ 1-x} { Mn}_{x} Te}}}}.

  • PDF

Horizontal instability after acromioclavicular joint reduction using the two-hole technique is preferred over the loop technique: a single-blind randomized clinical trial

  • Mardani-Kivi, Mohsen;Asadi, Kamran;Leili, Ehsan Kazemnejad;Hashemi-Motlagh, Keyvan;Izadi, Amin;Pishgahpour, Mona;Darabipour, Zohre
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.224-229
    • /
    • 2022
  • Background: Most acromioclavicular joint (ACJ) injuries are caused by direct trauma to the shoulders, and various methods and techniques are used to treat them; however, none of the options can be considered the gold standard. This study examines the horizontal stability of the ACJ after a complete dislocation was repaired using one of two Ethibond suture techniques, the loop technique and the two holes in the clavicle technique. Methods: In this single-blind, randomized clinical trial, 104 patients diagnosed with complete ACJ dislocation type V were treated using Ethibond sutures with either the loop technique or the two holes in the clavicle technique. Horizontal changes in the ACJ were radiographically assessed in the lateral axial view, and shoulder function was evaluated by the Constant (CS) and Taft (TS) scores at intervals of 3, 6, and 12 months after surgery. Results: The horizontal stability of the ACJ was better with the two-hole technique than the loop technique at all measurement times. CS and TS changes showed a significant upward trend over time with both techniques. The mean CS and TS at the final visit were 95.2 and 11.6 with the loop technique and 94.0 and 11.9 with the two-hole technique, respectively. The incidence of superficial infections caused by the subcutaneous pins was the same in the two groups. Conclusions: Due to the improved ACJ stability with the two-hole technique, it appears to be a more suitable option than the loop technique for AC joint reduction.

A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation (실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

Study on Ego states in the view of Transactional analysis, Coping style and Health states of Nursing Students (상호교류분석으로 본 간호학생의 자아상태와 스트레스 대처방법 및 건강상태에 관한 연구)

  • Won, Jeong-Sook;Kim, Jeong-Hwa
    • Journal of East-West Nursing Research
    • /
    • v.7 no.1
    • /
    • pp.68-81
    • /
    • 2002
  • The purpose of this study is to analyze the type of ego states and stress coping style on female college students who are in the course of nursing study. This study is performed in the view of Transactional Analysis and designed to scrutinize descriptive correlations between the type of ego states and stress coping style. The subject is consists of 144 freshmen and sophomore, 138 junior and senior students group, who are students of K nursing college located in Seoul. The sampling investigation period is on Sept. 14, 2002 to Oct. 26, 2002. The measuring instrument used for Transactional Analysis ego state is 50 items Ego-gram research paper devised by Dusay(1997). For studying coping style, Folkman & Lazarus's measurement(1984) was adopted, which is translated and modified by Han, and Oh,(1990). Health states is adopted by standardized health inspecting instrumental table (Cornell Medical Index:CMI) which is designed for Korean people by Ko and Park(1980) Statistic average and standard deviation were generated by using SPSS PC+, t=test and Pearson correlation. The results were as follows: 1) In the type of ego states on both groups indicated the arithmetic apex NP(maximum value), then the point A was high and the data made a down slope to point AC. In the comparison to type of ego states between two groups, only at point CP, the data value of upper year students represented higher than that of lower year ones by c(t=2.28, p=.023). 2) Stress coping style of whole students were highly and affirmatively dedicated to research. Especially hopeful aspect(t=.67, p=.05), relaxation of tension(t=-2.16, p=.03) made significant difference each other in the view of arithmetic calculation. 3) In view of nursing students' physical health states, there is significant difference in past history(t=2.50, p=.013) and in case of mental health states, there are considerable discrepancies between lower group(73.52) and upper group(75.11)(p<.05). In view of all field, state of tension(t=2.13, p=.048) has difference. 4) While verifying coping style in terms of ego states level between lower and upper students group, In type CP, high level ego states group indicated significant difference on stress coping style area than low leveled group and made such sequences as the central point of problem, In type NP, sequences such as the central point of problem, In type A, the central point of problem, In type FC, hopeful aspect and In type AC, hopeful aspect and indifference were derived significantly different (p<.05). 5) While verifying health state differences in the level of lower and upper ego states, In type FC, low level group(150.29) marked higher point than upper group(145.19), there is remarkable discrepancy and so did whole health state(p=.014), In type AC both mental state(p=.000) and whole health state (p=.015) showed differences. 6) When analyzing correlations between whole students' ego states, copying style and health state, all type of ego state showed differences(p<.001). In correlations between ego state and health state, in type FC physical state had an apex and there are inverse correlations among the other types. Especially, type FC showed inverse correlations with great discrepancies(p<.05). In mental state, type NP(${\gamma}=.198$, p<.001) and type A(${\gamma}=.166$, p<.05) represented straight correlations with remarkable differences. Especially, In type AC showed inverse correlations(${\gamma}=.282$, p<.001). In case of correlations between copying style and health state, indifference(${\gamma}=-.157$) and relaxation of tension(${\gamma}=-.158$) presented great difference(p<.05). In mental state, central point of problem and search for social support showed straight correlations with great discrepancies(p<.05), hopeful aspect and indifference showed inverse correlations with considerable differences(p<.001).

  • PDF

Standardization Study of Thermal Imaging using the Acupoints in Human Body (적외선 체열 영상의 표준화 연구 부위별 대표 혈위를 중심으로)

  • Choi, Young-Chon;Lim, Chung-San;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.113-122
    • /
    • 2008
  • Objective: The purpose of this study was to invigorate the use of infrared thermal imaging apparatus as a diagnostic tool in Oriental medicine by providing standard temperature on specific acupoints. Methods: Subjects for the study was recruited through an advertisement in the school homepage(www.sangji.ac.kr) explaining the objectives and methods. 100 volunteers agreeing to terms were selected and measured the full body thermal image. Common acupoints used in the clinical surrounding were chosen and final 63 acupoints were selected for the measurement. Male/female and right/left readings were obtained for the analysis. Results: Following results were obtained from analyzing the body temperature of 50 male subjects and 50 female subjects 1. Subjects participating in the study ranged from 19 years of age to 44 years. Median male age at $26.86{\pm}6.02$ and female age at $22.88{\pm}2.74$, respectively. 2. For all acupoints, no significant differences were witnessed between the gender and right, left side of the body. 3. 10 acupoints from the facial region(18 bilateral), 8 acupoints from the chest/abdomen region(10 bilateral), 6 acupoints from the back region(11 bilateral), 17 acupoints from the upper extremity(34 bilateral), and 22 acupoints from the lower extremity(44 bilateral) were chosen. 4. In the facial region, BL2 showed the highest temperature and GV26 showed the lowest. 5. In the chest/abdomen region, CV22 showed the highest temperature and CV6 showed the lowest. 6. In the back region, GV14 showed the highest temperature and BL23 showed the lowest. 7. In the upper extremity region, jianqian(extra point) showed the highest temperature and baxie(extra point) showed the lowest. 8. In the lower extremity region, KI1 and bafeng(extra point) shoed the highest temperature and BL40 showed the lowest. Conclusions: Based on the standard body temperature measured on specific acupoints throughout the body, we hope these findings can trigger further studies on applications of infrared thermal imaging and clinical usage in the field of oriental medicine.

A-team Based Approach for Reactive Power/Voltage Control Considering Steady State Security Assessment (정태 안전성 평가를 고려한 무효전력 전압제어를 위한 A-team기반 접근법)

  • Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.150-159
    • /
    • 1996
  • In this paper, an A-team(Asynchronous Team ) based approach for Reactive power and volage control considering static security assessment in a power system with infrastructural deficiencies is proposed. Reactive power and voltage control problem is the one of optimally establishing voltage level given several constraints such as reactive generation, voltage magnitude, line flow, and other switchable reactive power sources. It can be formulated as a mixed-integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The security assessment is to estimate the relative robustness of the system in Its present state through the evaluation of data provided by security monitoring. Deterministic approach based on AC load flow calculations is adopted to assess the system security, especially voltage security. A security metric, as a standard of measurement for power system security, producting a set of discrete values rather than binary values, is employed. In order to analyze the above two problems, reactive power/voltage control problem and static security assessment problem, in an integrated fashion for real-time operations, a new organizational structure, called an A-team, is adopted. An A-team is an organization for agents which ale all autonomeus, work in parallel and communicate asynchronously, which is well-suited to the development of computer-based, multi-agent systems for operations. This A-team based approach, although it is still in the beginning stage, also has potential for handling other difficult power system problems.

  • PDF