• Title/Summary/Keyword: AC/DC

Search Result 2,341, Processing Time 0.023 seconds

Electric Model of Li-Ion Polymer Battery for Motor Driving Circuit in Hybrid Electric Vehicle

  • Lee, June-Sang;Lee, Jae-Joong;Kim, Mi-Ro;Park, In-Jun;Kim, Jung-Gu;Lee, Ki-Sik;Nah, Wan-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.932-939
    • /
    • 2012
  • This paper presents an equivalent circuit model of a LIPB (Li-Ion Polymer battery) for Hybrid Electric Vehicles (HEVs). The proposed equivalent circuit can be used to predict the charging/discharging characteristics in time domain as well as the impedance characteristic analysis in frequency domain. Based on these features, a one-cell model is established as a function of Depth of Discharge (DoD), and a 48-cell model for a battery pack was also established. It was confirmed by experiment that the proposed model predict the discharging and impedance (AC) characteristics quite accurately at different constant current levels. To check the usefulness of the proposed circuit, the model was used to simulate a motor driving circuit with an Insulated Gate Bipolar Transistor (IGBT) inverter and Brushless DC (BLDC) motor, and it is confirmed that the model can calculate the battery voltage fluctuation in time domain at different DoDs.

Implementation of Vector Control system for $3\phi$ Induction Motor (3상 유도 전동기 벡터제어 구동시스템의 구현)

  • 홍순일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • In recent year, inverters and cycloconverters system are widely used for fed induction motor drives. Motor drives by cycloconverter is possible to frequency have been directly changed without AC/DC converter, so that circuits is simpler than inverter. A aims of this paper is the control strategy and hardware design for vector control system by cycloconverter fed induction motor drives. In this paper, Algorithm of vector control is derivlid from the model of controlled current source-fed induction motor. Vector control system is implemented using these algorithm and a pulse width controled cycloconverter using a SCR. Cycloconverter of vector control system is controlled by pulse width of SCR's trigger signal. pulse width is controlled primary command current $li_1l$ and frequency TEX>$\omega_1$..

  • PDF

Aging Diagnosis of Underground Distribution Power Cables by Isothermal Relaxation Current Measurement Equipment (완화전류 측정에 의한 지중배전케이블의 열화진단)

  • Kim, Ju-Yong;Song, Il-Keun;Kim, Dong-Myung;Yun, Tae-Sang;Jeong, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.502-505
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this papar we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

  • PDF

Risk Assessment of Energy Storage System using Event Tree Analysis (ETA를 이용한 에너지저장시스템의 위험성 평가)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Eui-Sik;Park, Young-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.34-41
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on six items of ESS: the whole system, battery, BMS, PCS, ESS and cable. To achieve that, ESS work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew initiation events (IE) and end states (ES). ETA is applied to the main functions of each item, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events ; loss of grid electricity of ESS, loss of battery electricity(DC) of battery, impairment of electric function of BMS, loss of grid electricity(AC) of PCS, loss of data of EMS, Mechanical damage of cable, event sequence analysis conducted on the basis of event trees. If the suggested IEs and ESs are applied on the basis of ESS event cases, it is expected to prevent the same kinds of accident and operate ESS safely.

SRM Drive System Using 6-switch IGBT Module (6-Switch IGBT Module을 이용한 SRM 구동 시스템)

  • Kim Yuen-Chung;Yoon Yong-Ho;Lee Won Cheol;Lee Byoung-Kuk;Won Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.569-577
    • /
    • 2005
  • In this paper, a new control scheme to use 6-switch IGBI module for 3-phase switched reluctance motors(SRM) is proposed. Compared with the conventional asymmetric bridge converter topology, it can minimize the entire system size and cost. Therefore, it may have a new topology lot SRM to compare the other ac motors, such as induction motors, brushless dc motors, and so on. The validity of the proposed method is verified by simulation, and experimental results.

3차원적 도핑 분포 측정을 위한 SCM 응용 방법 (The SCM Method for Three-Dimensional Dopant Profiles)

  • Lee Jun-Ha;Lee Hoong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.1
    • /
    • pp.7-11
    • /
    • 2006
  • Through SCM modeling, we found that the depletion layer in silicon was of a form of a spherical capacitor with the SCM tip biased. Two-dimensional (2D) finite differential method code with a successive over relaxation (SOR) solver has been developed to model the measurements by SCM of a semiconductor wafer that contains an ion-implanted impurity region. Then, we theoretically analyzed the spherical capacitor and determined the total depleted-volume charge Q, capacitance C, and the rate of capacitance change with bias dC/dV. It is very important to observe the depleted carriers' movement in the silicon layer by applying the bias to the tip. So, we calculated the depleted-volume charge, considering different factors such as tip size, oxide thickness, and applied bias (dc+ac), which have an influence on potential and depletion charges.

  • PDF

The Overview of a Digital Power System Simulator for Large Power System Analysis

  • Kim, Tae-Kyun;Kim, Yong-Hak;Shin, Jeong-Hoon;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.93-99
    • /
    • 2003
  • This paper deals with the development and testing of a large-scale, realtime digital power system simulator for the Korean Electric Power Corporation. The KEPS Simulation Center is located at KEPCO's research center (KEPRI) in Taejon, South Korea and has been operated since September 2001. The KEPS Simulation Center includes a wide range of off line power system simulation and analysis tools, as well as an advanced realtime digital simulator for the study of large scale AC and DC system performance. Because the application scope of the KEPS realtime simulator is broad and because the network models being considered are significantly larger and more complex than in traditional realtime simulator applications, many developments and tests have been required during the course of the project. In this paper, the authors describe some of these developments and present results from various benchmark tests that have been performed.

Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion (지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

A Study on the Effects of Hot Phonon in Electron Transport at Millimeter-wave Frequencies (밀리미터 주파수에서 전자의 운동에 대한 Hot Phonon의 영향 연구)

  • 윤태섭
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1070-1078
    • /
    • 1998
  • A density of phonon is increased by application of electric field. At this time the phonon which has higher energy than around is called hot phonon is disappeared after 7 picosecond by scattering with electron and loss energy. Since the lifetime of phonon is very short, the effects of hot phonon can be neglected in the low speed semiconductor device, but it must be considered in high speed devices. DC and AC electric fields are applied to bulk GaAs, and the density of phonon is obtained and analyzed for its effects on electron velocity and electron distribution using Monte Carlo simulation method. Under high electric filed the density of hot phonon increased and energy of hot phonon is decreased by scattering with electron on the other hand the energy of electron is increased. Therefore electron move from central valley of conduntion band to satellite vallies and the valocity of electron decrease since the mass of electron in satellite vally is heavier than central vally. In millimeter wave frequencies, the effects of hot phonon increased at higher frequencies.

  • PDF

Maximum Power Point Tracking Controller Connecting PV System to Grid

  • Ahmed G. Abo-Khalil;Lee Dong-Choon;Choi Jong-Woo;Kim Heung-Geun
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.226-234
    • /
    • 2006
  • Photovoltaic (PV) generators have nonlinear V-I characteristics and maximum power points which vary with illumination level and temperature. Using a maximum power point tracker (MPPT) with an intermediate converter can increase the system efficiency by matching the PV systems to the load. This paper presents a maximum power point tracker based on fuzzy logic and a control scheme for a single-phase inverter connected to the utility grid. The fuzzy logic controller (FLC) provides an adaptive nature for system performance. Also the FLC provides excellent features such as fast response, good performance and the ability to change the fuzzy parameters to improve the control system. A single-phase AC-DC inverter is used to connect the PV system to the grid utility and local loads. While a control scheme is implemented to inject the PV output power to the utility grid at unity power factor and reduced harmonic level. The simulation results have shown the effectiveness of the proposed scheme.