• Title/Summary/Keyword: AC/DC

Search Result 2,341, Processing Time 0.03 seconds

A CMOS Interface Circuit for Vibrational Energy Harvesting (진동에너지 수확을 위한 CMOS 인터페이스 회로)

  • Yang, Min-jae;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.267-270
    • /
    • 2014
  • This paper presents a CMOS interface circuit for vibration energy harvesting. The proposed circuit consists of an AC-DC converter and a DC-DC boost converter. The AC-DC converter rectifies the AC signals from vibration devices(PZT), and the DC-DC boost converter generates a boosted and regulated output at a predefined level. A full-wave rectifier using active diodes is used as the AC-DC converter for high efficiency, and a schottky diode type DC-DC boost converter is used for a simple control circuitry. A MPPT(Maximum Power Point Tracking) control is also employed to harvest the maximum power from the PZT. The proposed circuit has been designed in a 0.35um CMOS process. The chip area is $530um{\times}325um$. Simulation results shows that the maximum efficiencies of the AC-DC converter and DC-DC boost converter are 97.7% and 89.2%, respectively. The maximum efficiency of the entire system is 87.2%.

  • PDF

DC Characteristics Analysis of Various AC loads for Hybrid Distribution (하이브리드 급전을 위한 다양한 가정용 교류부하의 직류특성연구)

  • Lee, Young-Jin;Han, Dong-Ha;Choi, Jung-Muk;Jeong, Byong-Hwan;Kim, Dong-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • Recently, the use of DC power increased due to the increased use of digital load. Power factor of input current decrease and input current harmonics increase, and conversion loss which is occurred in the AC / DC converter is a problem to provide the proper DC voltage to the device equipped with an internal AC / DC converter. Hybrid system supplies the AC power and DC power to AC load (motor load and the transformer load) and DC loads (computers, TV, LED fluorescent light) at the same time it supplies the renewable energy and utility energy taken power from Utility to user for improving the efficiency and renewable energy improvements in ease of use. This paper studies DC characteristics of traditional AC load for Hybrid distributions.

High Power Factor 3-Phase AC-DC Converter without LC Filter (LC필터가 없는 고역율 3상 AC-DC 컨버터)

  • Nam, Jing-Rak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1894-1898
    • /
    • 2007
  • Conventional 3-phase AC-DC converter is frequently in the industrial world. In this paper, the high power factor 3-phase AC-DC converter which can reduce its weight and volume is proposed. The high power factor 3-phase AC-DC converter without LC filter can realize light weight and low-cost. In spite of elimination of LC filter, the performance of the high power 3-phase AC-DC converter is almost the same as conventional 3-phase AC-DC converter. Finally, this result can be expected to be applied to aviation and the space industry with high power density and high power factor.

Two-Switch Auxiliary Resonant DC Link Snubber-Assisted Three-Phase Soft Switching PWM Sinewave Power Conversion System with Minimized Commutation Power Losses

  • Nagai, Shinichiro;Sato, Shinji;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • This paper presents a high-efficient and cost effective three-phase AC/DC-DC/AC power conversion system with a single two-switch type active Auxiliary Resonant DC Link (ARDCL) snubber circuit, which can minimize the total power dissipation. The active ARDCL snubber circuit is proposed in this paper and its unique features are described. Its operation principle in steady-state is discussed for the three phase AC/DC-DC/AC converter, which is composed of PWM rectifier as power factor correction (PFC) converter, sinewave PWM inverter. In the presented power converter system not only three-phase AC/DC PWM rectifier but also three-phase DC/AC inverter can achieve the stable ZVS commutation for all the power semiconductor devices. It is proved that the proposed three-phase AC/DC-DC/AC converter system is more effective and acceptable than the previous from the cost viewpoint and high efficient consideration. In addition, the proposed two-switch type active auxiliary ARDCL snubber circuit can reduce the peak value of the resonant inductor injection current in order to maximize total system actual efficiency by using the improved DSP based control scheme. Moreover the proposed active auxiliary two-switch ARDCL snubber circuit has the merit so that there is no need to use any sensing devices to detect the voltage and current in the ARDCL sunbber circuit for realizing soft-switching operation. This three-phase AC/DC-DC/AC converter system developed for UPS can achieve the 1.8% higher efficiency and 20dB lower conduction noise than those of the conventional three-phase hard-switching PWM AC/DC-DC/AC converter system. It is proved that actual efficiency of the proposed three-phase AC/DC-DC/AC converter system operating under a condition of soft switching is 88.7% under 10kw output power.

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.

Switched Inductor Z-Source AC-DC Converter

  • Sedaghati, Farzad;Hosseini, Seyed Hossein;Sarhangzadeh, Mitra
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.67-76
    • /
    • 2012
  • Due to the increasing amount of applications of power electronic ac-dc converters, it is necessary to design a single-stage converter that can reliably perform both buck and boost operations. Traditionally, this can be achieved by double-stage conversion (ac/dc-dc/dc) which ultimately leads to less efficiency and a more complex control system. This paper discusses two types of modern ac-dc converters. First, the novel impedance-source ac-dc converter, abbreviated as custom Z-source rectifier, is analyzed; and then, switched inductor (SL) Z-source ac-dc converter is proposed. This paper describes the Z-source rectifiers' operating principles, the concepts behind them, and their superiorities. Analysis and simulation results show that the proposed custom Z-source rectifier can step up and step down voltage; and the main advantage of the SL Z-source ac-dc converter is its high step-up capability. Low ripple of the output dc voltage is the other advantage of the proposed converters. Finally, the SL Z-source ac-dc converter is compared with the custom Z-source ac-dc converter.

DC-Link Capacitance Estimation using Support Vector Regression in AC/DC/AC PWM Converters (SVR을 이용한 AC/DC/AC PWM 컨버터의 직류링크 커패시턴스 추정)

  • Ahmed G. Abo-Khalil;Jang, Jeong-Ik;Lee, Dong-Choon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.81-87
    • /
    • 2007
  • This paper proposes a new capacitance estimation scheme for a DC-link capacitor in a three-phase AC/DC/AC PWM converter. A controlled AC voltage with a lower frequency than the line frequency is injected into the DC-link voltage, which then causes AC power ripples at the DC side. By extracting the AC voltage and power components on the DC output side using digital filters, the capacitance can then be calculated using the Support Vector Regression (SVR). By training of SVR, a function which relates a given input (capacitor's power) and its corresponding output (capacitance value) can be derived. This function is used to predict outputs for given inputs that are not included in the training set. The proposed method does not require the information of DC-link current and can be simply implemented with only software and no additional hardware. Experimental results confirm that the estimation error is less than 0.16%.

A CMOS Interface Circuit with MPPT Control for Vibrational Energy Harvesting (진동에너지 수확을 위한 MPPT 제어 기능을 갖는 CMOS 인터페이스 회로)

  • Yang, Min-jae;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.412-415
    • /
    • 2015
  • This paper presents a MPPT(Maximum Power Point Tracking) control CMOS interface circuit for vibration energy harvesting. The proposed circuit consists of an AC-DC converter, MPPT Controller, DC-DC boost converter and PMU(Power Management Unit). The AC-DC converter rectifies the AC signals from vibration devices(PZT). MPPT controller is employed to harvest the maximum power from the PZT and increase efficiency of overall system. The DC-DC boost converter generates a boosted and regulated output at a predefined level and provides energy to load using PMU. A full-wave rectifier using active diodes is used as the AC-DC converter for high efficiency, and a schottky diode type DC-DC boost converter is used for a simple control circuitry. The proposed circuit has been designed in a 0.35um CMOS process. The chip area is $950um{\times}920um$.

  • PDF

A Single-Phase Embedded Z-Source DC-AC Inverter by Asymmetric Voltage Control (비대칭 전압 제어를 이용한 단상 임베디드 Z-소스 DC-AC 인버터)

  • Oh, Seung-Yeol;Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.306-314
    • /
    • 2012
  • In case of the conventional DC-AC inverter using two DC-DC converters with unipolar output capacitor voltages, for generating the AC output voltage, the output capacitor voltages of its each DC-DC converter must be higher than the DC input voltage. To solve this problem, this paper proposes a single-phase DC-AC inverter using two embedded Z-source converters with bipolar output capacitor voltages. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The AC output voltage is obtained by the difference of the output capacitor voltages of each converter. Though the output capacitor voltage of converter is relatively low compared to the conventional method, it can be obtained the same AC output voltage. Moreover, by controlling asymmetrically the output capacitor voltage, the AC output voltage of the proposed system is higher than the DC input voltage. To verify the validity of the proposed system, a DSP(TMS320F28335) based single-phase embedded Z-source DC-AC inverter was made and the PSIM simulation was performed under the condition of the DC source 38V. As controlled symmetrically and asymmetrically the output capacitor voltages of each converter, the proposed inverter could produce the AC output voltage with sinusoidal waveform. Particularly, in case of asymmetric control, a higher AC output voltage was obtained. Finally, the efficiency of the proposed system was measured as 95% and 97% respectively in case of symmetric and asymmetric control.

Improvement measures for power quality of DC distribution (직류배전의 전력품질 향상 대책)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.536-537
    • /
    • 2010
  • If DC voltage adjustment can be controlled very easily, it is much more effective rather than AC in transmission efficiency. The main reason why DC is more effective than AC, DC has the same role as the 70[%] of AC whenever the same power send. In addition, AC streams the surface of electrical wire, but DC streams overall of electrical wire. Digital load, which is operated by DC, has increased in modern times. The step of convert of AC-DC has to be reduced. When we turn the dispersed AC-DC converters into the concentrated AC-DC converter, it can improve the effective of the whole system. Further more, if digital society develops more than now and the time of electric vehicle comes, the need of DC will increase much more than these days. This paper suggests that DC output of distributed power source and high efficient 3 phase PWM converter can control the adjustment of output voltage, harmonic restraint, power factor improvement and dump power.

  • PDF