• Title/Summary/Keyword: ABDUCTION

Search Result 647, Processing Time 0.036 seconds

The Effect of Scapular Stabilization Exercise and Thoracic Joint Mobilization on the Scapular Function in Adults with Scapular Dysfunction (어깨뼈 안정화운동과 등뼈관절가동술이 어깨뼈 기능이상이 있는 성인의 어깨 기능에 미치는 영향)

  • Lee, Sang-Bin
    • Journal of Industrial Convergence
    • /
    • v.19 no.3
    • /
    • pp.83-90
    • /
    • 2021
  • The purpose of this study was to investigate the effect of scapular stabilization exercise and thoracic joint mobilization on scapular position, scapular motion and shoulder pain and disability index(SPADI) in adults with scapular dysfunction. A total 42 subjects were divided into a scapular stabilization exercise group(A, n=14), a thoracic joint mobilization group(B, n=14) and scapular stabilization exercise with thoracic joint mobilization group(C, n=14) and performed exercise and joint mobilization three times per week for four weeks, total 12 times. As for changes in scapular position among the groups, group C showed statistically significant increase(p<.05). In changes of scapular motion among the groups, group C showed statically significant improvement in shoulder abduction 45° and 90° both(p<.05), In changes of SPADI among the groups, group C were showed statistically significant improvement(p<.05). In conclusion, scapular stabilization exercise and thoracic joint mobilization were effective on improving scapular position, movement and SPADI score in adults with scapular dysfunction.

A Possibility Analysis of Domestic Terrorism in South Korea by Focusing on Afghanistan under the Taliban Forces (탈레반의 아프가니스탄 장악에 따른 국내 테러 발생 가능성 분석)

  • Oh, Hangil;Ahn, Kyewon;Bae, Byunggul
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.848-863
    • /
    • 2021
  • Purpose: On August 16, 2021, the Taliban established the Taliban regime after conquering capital Kabul of the Afghan by using the strong alliance of international terrorist organizations. The Taliban carried out terrorism targeting the Korean people, including the kidnapping of Kim Seon-il in 2004, the abduction of a member of the Saemmul Church in 2007, and the attack on Korean Provincial Reconstruction Team in 2009. Therefore, this research has shown the possibility of Taliban terrorism in Korea. Method: Based on the statistical data on terrorism that occurred in Afghanistan, Taliban's various terrorist activities such as tactics, strategies, and weapons are examined. Consequently, the target facilities and the type of terrorist attacks are analyzed. Result: The Taliban are targeting the Afghan government as their main target of attack, and IS and the Taliban differ in their selection of targets for terrorism. Conclusion: From the result of this research, we recommend Korea need to reinforce the counter terrorism system in soft targets. Because If the Taliban, which has seized control of Afghanistan, and IS, which has established a worldwide terrorism network, cooperate to threaten domestic multi-use facilities with bombing, the Republic of Korea may face a terrorist crisis with insufficient resources and counter-terrorism related countermeasures.

A Case Report of Bilateral Abducens Nerve Palsy Using Korean Medicine (양측성 외전신경 마비 환자 치험 1례)

  • Lee, Dong Hyuk;Lee, Young Eun;Lee, Bo Yun;Doo, Kyung Hee;Kim, Soo Kyung;Cho, Seung Yeon;Park, Seong Uk;Park, Jung Mi;Ko, Chang Nam
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.57-65
    • /
    • 2014
  • ■ Objectives The purpose of this case report is to show an effect of korean medicine for patient with bilateral abducens nerve palsy. ■ Methods This patient was 58 year-old man who was diagnosed with bilateral abducens nerve palsy. The patient had Diabetes Mellitus, hypertension, benign prostatic hyperplasia and dyslipidemia as underlying diseases. The patient had symptoms of limited eye movement to lateral, diplopia, dizziness and mild headache. He was treated by korean medicine, containing electroacupuncture, pharmacoacupuncture, moxibustion and herb medicines during 13 days of hospitalization and following outpatient department. His eye movement was evaluated by the method of Scott and kraft and discomfort from his symptoms was scored by the Numerous Rating Scale. And other general conditions were measured. ■ Results After that period, patient's abduction deficit was improved and subjective discomfort from his symptoms was getting better. His other conditions were also better, compared with his admission. ■ Conclusion This study suggests that Korean medicine could have a therapeutic effect for bilateral abducens nerve palsy. So, It could help to relieve patient's symptoms and make general conditions better.

  • PDF

Kepler's Scientific Problem Finding and the Abductive Reasoning in his Discovery of the Retinal Image Formation (Kepler의 망막 상 이론 형성 과정에서의 과학적 문제 발견과 귀추적 사고)

  • Kim, Young-Min
    • Journal of The Korean Association For Science Education
    • /
    • v.26 no.7
    • /
    • pp.835-842
    • /
    • 2006
  • The aims of this study are to investigate how Kepler found a scientific problem for the retinal image theory and how abductive reasoning was used in his theory development, and to find implications for teaching creativity in science class from his thinking processes in the scientific discovery. Through the analysis of the related literatures, it was found that Kepler's problem finding in his retinal image theory came from the critical analysis of contemporary theories of vision, based on his relevant knowledge of optics, as he formulated his own hypothesis to build a new theory in eye vision employing optical phenomenon in spherical lens, which is a kind of abductive reasoning. From the results, three suggestions are proposed, that: (a) in the development of creativity teaching material, the situations like Kepler's problem finding need to be included in the programs; (b) it should be taught that relevant scientific knowledge is important for problem finding and hypothesis formulating; and (c) the experience of successful problem solving by themselves could help them find new scientific problem(s).

Use of custom glenoid components for reverse total shoulder arthroplasty

  • Punyawat Apiwatanakul;Prashant Meshram;Andrew B. Harris;Joel Bervell;Piotr Lukasiewicz;Ridge Maxson;Matthew J. Best;Edward G. McFarland
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.343-350
    • /
    • 2023
  • Background: Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications. Methods: This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported. Results: Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1-10.7 months), compared with 5.5 months (range, 2-8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P<0.01; Simple Shoulder Test, P=0.02; Single Assessment Numeric Evaluation, P<0.01; Western Ontario Osteoarthritis of the Shoulder Index, P<0.01). Range of motion improved for forward flexion and abduction (P=0.03 for both) and internal rotation up the back (P=0.02). Pain and satisfaction also improved (P<0.01 for both). Conclusions: Prolonged time (>6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. Satisfactory short-term radiographic and clinical follow-up can be achieved with a well-fitting device. Level of evidence: III.

Biometric analysis hand parameters in young adults for prosthetic hand and ergonomic product applications

  • Gkionoul Nteli Chatzioglou;Yelda Pinar;Figen Govsa
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.172-182
    • /
    • 2024
  • This study aimed to evaluate the superficial anatomy, kinesiology, and functions of the hand to reveal its morphometry and apply the findings in various fields such as prosthetic hand and protective hand support product design. We examined 51 young adults (32 females, 19 males) aged between 18-30. Hand photographs were taken, and measurements were conducted using ImageJ software. Pearson correlation analysis was performed to determine the relationship between personal information and the parameters. The results of the measurements showed the average lengths of finger segments: thumb (49.5±5.5 mm), index finger (63.9±4.1 mm), middle finger (70.7±5.2 mm), ring finger (65.5±4.8 mm), and little finger (53.3±4.3 mm). Both females and males, the left index finger was measured longer than the right index finger. The right ring finger was found to be longer than the left in both sexes. Additionally, length differences between fingers in extended and maximally adducted positions were determined: thumb-index finger (56.1±6.2 mm), index-middle finger (10.7±4.1 mm), middle-ring finger (10.8±1.4 mm), and ring-little finger (25.6±2.7 mm). Other findings included the average radial natural angle (56.4°±10.5°), ulnar natural angle (23.4°±7.1°), radial deviation angle (65.2°±8.2°), ulnar deviation angle (51.2°±9.6°), and grasping/gripping angle (49.1°±5.8°). The average angles between fingers in maximum abduction positions were also measured: thumb-index finger (53.4°±6.5°), index-middle finger (17.2°±2.6°), middle-ring finger (14.3°±2.3°), and ring-little finger (32.1°±7.0°). The study examined the variability in the positioning of proximal interphalangeal joints during maximum metacarpophalangeal and proximal interphalangeal flexion, coinciding with maximum distal interphalangeal extension movements. The focal points of our observations were the asymmetrical and symmetrical arches formed by these joints. This study provides valuable hand parameters in young adults, which can be utilized in various applications such as prosthetic design, ergonomic product development, and hand-related research. The results highlight the significance of considering individual factors when assessing hand morphology and function.

Effects of Shoulder Muscle Strength on Terminal Range by Humeral Head Retroversion (상완골 후경각이 가동역에 따른 견관절 근력에 미치는 영향)

  • Park, Si-Young;Lee, Dong-Jun
    • Journal of Life Science
    • /
    • v.20 no.4
    • /
    • pp.549-554
    • /
    • 2010
  • Increased external rotation and decreased internal rotation have been noted to occur progressively in the throwing shoulders of baseball pitchers. The purpose of this study was to provide descriptive data for terminal range eccentric antagonist/concentric agonist shoulder muscle strength in collegiate baseball pitchers with humeral head retroversion diagnosed through MRI. The dominant and non-dominant shoulders of 9 asymptomatic baseball pitchers were tested through a range of 20 degrees of external rotation to 90 degrees of internal rotation using the Biodex system 3 isokinetic dynamometer at speeds of $90^{\circ}/s$ and $180^{\circ}/s$. Differences between the dominant and non-dominant shoulders were assessed using the paired samples t-test. Total range of motion, measured at $90^{\circ}$ of glenohumeral abduction, was $180.1^{\circ}$ for dominant shoulders and $183.7^{\circ}$ for non-dominant shoulders. Humeral head retroversion measured $47.6{\pm}6.1^{\circ}$ in dominant and $37.8{\pm}5.3^{\circ}$ in non-dominant extremities. The mean internal rotator concentric contraction (IR-Con) showed a significant difference compared to $31.5{\pm}5.1$ (Nm) in dominant and $38.7{\pm}5.2$ (Nm) in non-dominant shoulders at $180^{\circ}/s$ (p<0.05). The mean external rotator eccentric contraction (ER-Ecc) showed a significant difference compared to $20.3{\pm}4.7$ (Nm) in dominant and $25.1{\pm}3.7$ (Nm) in non-dominant shoulders at $90^{\circ}/s$ (p<0.05). There is a pattern of increased external rotation and decreased internal rotation in the dominant extremity that significantly correlates with an increase in humeral retroversion.

Arthroscopic Treatment of Metallic Suture Anchor Failures after Bankart Repair (Bankart 수술 후 발생한 금속 봉합 나사못 합병증의 관절경적 치료)

  • Shin, Sang-Jin;Jung, Jae-Hoon;Kim, Sung-Jae;Yoo, Jae-Doo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • Purpose: This study presents 5 patients who had metallic anchor protrusion on glenoid after Bankart repair in anterior shoulder instability and reviewed the cause, clinical feature and arthroscopic removal technique. Method and Materials: 5 male with average age of 22 years (range 19 to 25 years) were included. 4 patients had arthroscopic Bankart repair and 1 patient had open repair for anterior shoulder instability. They had protruded metallic suture anchors on glenoid and the protruded suture anchors were removed arthroscopically using larger suture anchor empty inserter. Results: 4 patients had painful clicking sound with motion of abduction and external rotation and 1 patient showed shoulder instability. The ROM showed normal except mild degrees loss of external rotation. The position of protruded metallic anchor was 2, 3 and 5 O'clock in three patients and 4 O'clock in 2 patients. In 2 patients, the metallic suture anchor was malpositioned about 5mm off on the medial side from the anterior glenoid edge. All had Outerbrige classification Grade II-III chondral damage on humeral head and 1 patient showed glenoid cartilage destruction. None had shoulder instability after 2 years of follow-up. Constant score was 65 preoperatively and 89 postoperatively. ASES score was 67 preoperatively and 88 postoperatively. Conclusion: Symptoms of protruded suture anchor are not combined with instability. Most of symptoms were revealed from the rehabilitation period and confused with postoperative pain. Prompt diagnosis and early arthroscopic removal or impaction of protruded metallic suture anchor is recommended because of serious glenohumeral cartilage destruction. This is easy and simple and reproducible method to remove protruded metallic suture anchor arthroscopically.

  • PDF

Strength Evaluation of Sin91e-Radius Total Knee Replacement (TKR) (인공무릎관절의 단축법위 회전시 근력정가)

  • Wan, Jin-Young;Sub, Kwak-Yi
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.484-489
    • /
    • 2004
  • Artificial joint replacement is one of the major surgical advances of the 21th century. The primary purpose of a TKA (Total Knee Arthroplasty) is to restore normal knee Auction. Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from a chair or climbing stairs;(b) allow the same range of motion as an complete knee; and (c) provide adequate knee joint stability. Four individuals (2 peoples after surgery one year and 2 peoples after surgery three years) participated in this study. All they were prescreened for health and functional status by the same surgeon who performed the operations. Two days of accommodation practice occurred prior to the actual strength testing. The isometric strength (KIN-COM III) of the quadriceps and hamstring were measured at 60$^\circ$ and 30$^\circ$ of knee flexion, respectively. During isokinetic concentric testing, the range of motion was between 10$^\circ$ to 80$^\circ$ of knee flexion (stand-to-sit) and extension (sit-to-stand). for a given test, the trial exhibiting maximum torque was analyzed. A 16-channel MYOPACTM EMG system (Run Technologies, Inc.) was used to collect the differential input surface electromyographic (EMG) signals of the vastus medialis (VM), vastus lateralis(VL), rectus femoris (RF) during sit-to-stand and stand-to-sit tests. Disposable electrodes (Blue SensorTM, Medicotest, Inc.) were used to collect the EMG signals. The results were as follows; 1. Less maximum concentric (16% and 21% less for 1 yew man and 3 years mm, respectively) and isometric (12% and 29%, respectively) quadriceps torque for both participants. 2.14% less maximum hamstrings concentric torque for 1 year man but 16% greater torque for 3 years mm. However, 1 year man had similar hamstring isometric peak torque for both knees. 3. Less quadriceps co-contraction by 1 year man except for the VM at 10$^\circ$-20$^\circ$ and 30$^\circ$-50$^\circ$ range of knee flexion.

Short-term Outcomes of Arthroscopic Transtendinous Repair in Partial Articular Side Tears of the Rotator Cuff (회전근 개 부분 관절측 파열에 대한 관절경적 경 건 봉합술의 단기 결과)

  • Shin, Sung-Ryong;Yoo, Yon-Sik;Kim, Do-Young;Lee, Sang-Soo;Jeong, Un-Seob;Choi, Hyun-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.112-117
    • /
    • 2008
  • Purpose: This study prospectively evaluated the outcome of arthroscopic transtendinous repair as a treatment for partial articular side tears of the rotator cuff. Materials and Methods: Fifteen patients with symptomatic, partial articular side tears of the rotator cuff underwent modified transtendinous repair. The patient's mean age was 52.5 years and the mean duration of symptoms was 33.7 weeks. The visual analogue scale (VAS), the ASES score, the active ROM of the shoulder and the patient's satisfaction were evaluated both preoperatively and postoperatively. The clinical results were analyzed using the Wilcoxon's signed rank test. Results: The mean VAS was $6.6\pm1.1$ before treatment and $0.4\pm0.6$ at 6 month, and the ASES scores for all the patients were significantly better over the six-month period of follow-up (p<0.05). The mean active ROM in abduction was $94.3\pm22.3$ before treatment, $108.7\pm16.3$ at 1 month (p=0.0041) and $164.3\pm5.3$ at six months (p=0.0006). In flexion, it was $105.0\pm23.8$ before treatment, $119.0\pm17.4$ at 1 month(p=0.0075) and $174.3\pm5.3$ at six months (p=0.0006). At the final follow-up, 94% of patients were satisfied or very satisfied after operation. Conclusion: We experienced satisfactory clinical results after a short-term follow-up of arthroscopic transtendinous repair, and we believed this to be an effective procedure for patients with partial articular side tears of the rotator cuff.