• Title/Summary/Keyword: AATS

Search Result 4, Processing Time 0.023 seconds

A Study on Application Plan and Research Direction Proposal of Domestic Therapy Agriculture through Review of Animal-Assisted Therapy (동물매개치유 연구고찰을 통한 국내 치유농업의 방향설정과 적용방안 연구)

  • Kim, Dae-Sik;Lee, Young-Ran;Park, Hee-Geun;Pipit, Pitriani;Li, Wei;Yi, Gwang-Min;Jung, Sung-Gu;Park, Jong-Gu;Kim, Kyung-Il;Lee, Wang-Lok
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.1
    • /
    • pp.57-67
    • /
    • 2016
  • The purpose of this study was to review of animal-assisted therapy. Method: Animal-assisted therapies (AATs) in domestic and international studies (68 cases) were analyzed by searching databases, KERIS & KISS, and the Pub MED(NCBI). Result: In AATs, a few animals were used for the various disease or disorder. Dog centered therapies were most common.. AATs were used in the various disorder and disease. For the psychological effect, majority of the outcome variables were depression and anxiety. For the physical effect, the most outcome variables were blood pressure, heart rate, and stress hormone. However, These results show that AATs were confined to specific areas such as sensation-centered therapies. Conclusion: AATs had positive effects both in physical and psychological factors even if the study areas have not been applied to the various condition. The further research is needed to identify scientific grounds for the effects of the interventions through various therapies.

Economic-Statistical Design of VSSI Cause-Selecting Charts Considering Two Assignable Causes (두 개의 이상원인을 고려한 VSSI 원인선별 관리도의 경제적-통계적 설계)

  • Jung, Min-Su;Lim, Tae-Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.1
    • /
    • pp.29-39
    • /
    • 2009
  • This article investigates economic-statistical design of VSSI(variable sampling size and interval) cause-selecting charts considering two assignable causes. We consider a process which is composed of two dependent sub-processes. In each sub-process, two kinds of assignable cause may exist. We propose a procedure for designing VSSI cause-selecting charts, based on Lorenzen and Vance model. Computational experiments show that the VSSI cause-selecting chart is superior to the FSSI cause-selecting chart in the economic-statistical characteristics, even under two assignable causes.

Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve (On-X 기계판막을 이용한 판막치환술의 단기성적분석)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.742-748
    • /
    • 2004
  • The On-X valve was recently introduced. It was the aim of this study to assess the safety and feasibility from the data derived from 28 patients who underwent aortic and/or mitral valve replacement with this prosthesis in National Medical Center. Material and Method: From May 1999 and May 2003, a series of 28 consecutive patients who had been implanted with 32 On-X prosthesis were reviewed, The operative procedure comprised of 12 MVR, 10 AVR and 6 DVR. The study followed the guidelines of AATS/STS. Mean follow-up was 27 months (total 04 patient-years). Result: Early ($\leq$30 days) mortality was 7.44% (2/28) and no late mortality occurred in the study. Total actuarial freedom from mortality at 2 years was 92.86$\pm$4.87% for all cases, 100% for MVR, 90$\pm$9.49% for AVR, and 83.3$\pm$1.52% for DVR. Thromboembolic event occurred in 2 MVR patients and that was the only complication; therefore, the linearized incidence of valve related complications was 3.17%/ patient-years for all cases and 6.5%/patient-years for MVR and the actuarial freedom from valve related complications at 2 years was 84.85$\pm$10.75%. Preoperatively, 24 (85.71%) patients were in NYHA functional class III or IV but postoperatively, 25 (89,29%) patients were in NYHA functional class I or II. The levels of hemoglobin, hematocrit, serum LDH, reticulocyte rate and indirect bilirubin were all within normal range at postoperative 3 month. In mitral position, the peak gradient was 6.1$\pm$1.8 mmHg and the mean gradient was 3.0$\pm$0.6 mmHg and EOA were 2.54$\pm$0.56 $m^2$, 2.39$\pm$0.73 $m^2$, 2.34$\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$ at 27 mm, 29 mm, 31 mm, 33 mm respectively. In aortic postion, the peak gradient was 21.1 $\pm$14.12 mmHg and the mean gradient was 12.3$\pm$6.52 mmHg. Conclusion: Since there was no significant difference in the postoperative mortality, valve related complications and echocardiographic hemodynamic data compared to standard bileaflet design and since there was an improvement in the NYHA functional class and normal values of hemolytic indicators, it can be assumed that On-X valve is safe and feasible. However, accumulation of cases and long-term follow-up of this patient group is needed to establish this result.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.