• Title/Summary/Keyword: A.C. Parallel Operation

Search Result 105, Processing Time 0.03 seconds

An Equivalent Load Sharing by Wireless Parallel Operation Control in UPS

  • Byun, Young-Bok;Koo, Tae-Geun;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • Journal of KIEE
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2000
  • An equivalent load sharing control based on the frequency and voltage droop concept for parallel operation of two three-phase Uninterruptible Power Supply (UPS) systems with no control interconnection lines is presented in this paper. First of all, due to the use of active power and reactive power as control variables, the characteristics of output powers according to amplitude and phase differences between output voltages of two UPS systems are analyzed. Secondly, simulation results under different line impedance demonstrate the feasibility of the wireless parallel operation control. Finally, experiments are presented to verify the theoretical discussion with two three-phase 20kVA UPS systems employed TMS320C32, a kind of real time digital signal processor (DSP).

  • PDF

Parallel Operation Characteristics of Utility Interactive Photovoltaic System and Revolving Field Type Synchronous Generator (계통연계 태양광발전시스템과 회전계자형 동기발전기의 병렬운전 특성)

  • Ryu, Yeon-Soo;Yoo, Wang-Jin;Lee, Checl-Gyu;Moon, Jong-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.43-48
    • /
    • 2008
  • Through simulations and field experiment on A.C. parallel operation of both Utility Interactive Photovoltaic System and Diesel Engine Revolving Field Type Synchronous Generator, following factors have been found. First, the inverter should be operated in three modes of frequency(mode.1: ${\pm}$0.3Hz, mode.2: ${\pm}$1Hz, mode.3: ${\pm}$2Hz) as default, considering properties of operating Synchronous Generator. Second, as a result of supplying 13.5kW of residual power, it has been found that Synchronous Generator takes the power input only as reactive power, because it was electrically stable with frequency of 60.14Hz and high voltage of 222.3V even when power factor was -0.94. Besides, it was mechanically stable, too, because the quake, noise, and temperature of Synchronous Generator in this case were 7.5mm/s, 97dB, and $6^{\circ}C$ respectively, which were lower than normal load connection of 145.6kW; 11.03mm/s. Thus, load share of Revolving Field Type Synchronous Generator reduces according to the supply of Photovoltaic System to the load power. In this experiment, 200kW of Synchronous Generator and 40kW of Photovoltaic System were operated in parallel. The load share was 20% in maximum. and 11.1lit/hr of fuel was saved.

  • PDF

Built-in self test for testing neighborhood pattern sensitive faults in content addressable memories (Content addressable memory의 이웃패턴감응고장 테스트를 위한 내장된 자체 테스트 기법)

  • 강용석;이종철;강성호
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.8
    • /
    • pp.1-9
    • /
    • 1998
  • A new parallel test algorithm and a built-in self test (BIST) architecture are developed to test various types of functional faults efficiently in content addressable memories (CAMs). In test mode, the read oepratin is replaced by one parallel content addressable search operation and the writing operating is performed parallely with small peripheral circuit modificatins. The results whow that an efficient and practical testing with very low complexity and area overhead can be achieved.

  • PDF

An on-line non-invasive network monitor for the SPAX parallel computer (SPAX 병렬 컴퓨터에서의 온라인 무간섭 네트워크 성능 감시기)

  • 이승구
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.6
    • /
    • pp.44-50
    • /
    • 1997
  • This paper describes the design and test of an on-line non-invasive network performance monitor (hardware portion) for the SPAX parallel computer. The SPAX parallel computer supports up to 256 intel P6 processors with 4 P6 processors constituting a processign node. The nodes are interconnected with a dual two-level crossbar network calle dXcent-net. Since the performance of the SPAX parallel computer is highly dependent on the proper and efficient operation of the network, an on-line non-invasive network performance monitor (with hardware components) has been developed to aid in the monitoring and tunign of the Xcent-net. Successful testing of a prototype node monitor board and PC interface system shows that our monitor design provides a low-cost practical solution to this problem.

  • PDF

FUZZY TORQUE CONTROL STRATEGY FOR PARALLEL HYBRID ELECTRIC VEHICLES

  • PU J.-H.;YIN C.-L.;ZHANG J.-W.
    • International Journal of Automotive Technology
    • /
    • v.6 no.5
    • /
    • pp.529-536
    • /
    • 2005
  • This paper presents a novel design of a fuzzy control strategy (FCS) based on torque distribution for parallel hybrid electric vehicles (HEVs). An empirical load-regulating vehicle operation strategy is developed on the basis of analysis of the components efficiency map data and the overall energy conversion efficiency. The aim of the strategy is to optimize the fuel economy and balance the battery state-of-charge (SOC), while satisfying the vehicle performance and drivability requirements. In order to accomplish this strategy, a fuzzy inference engine with a rule-base extracted from the empirical strategy is designed, which works as the kernel of a fuzzy torque distribution controller to determine the optimal distribution of the driver torque request between the engine and the motor. Simulation results reveal that compared with the conventional strategy which uses precise threshold parameters the proposed FCS improves fuel economy as well as maintains better battery SOC within its operation range.

Potential Performance Enhancement of Dual Heat Pump Systems through Series Operation (히트펌프 직렬운전에 의한 성능 향상 가능성에 관한 연구)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.797-802
    • /
    • 2012
  • In this study, the potential performance enhancement in a dual heat pump system through series operation was investigated by a comparison between the performance for parallel and series operation for a heating supply temperature of $60^{\circ}C$. To compare the performance of each configuration fairly, the heat transfer surface area of the heat exchangers was fixed. The inlet temperatures and the flow rates of the heat source and the load were also fixed. In addition, the heat transfer and pressure drop characteristics of the working fluids were considered to achieve a more realistic comparison. The results show that the heating coefficient of performance (COP) of the series configuration is approximately 5% higher than that of the parallel configuration under the simulation conditions considered in the present study.

Design of the floating point multiplier performing IEEE rounding and addition in parallel (IEEE 반올림과 덧셈을 동시에 수행하는 부동 소수점 곱셈 연산기 설계)

  • 박우찬;정철호
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.11
    • /
    • pp.47-55
    • /
    • 1997
  • In general, processing flow of the conventional floating-point multiplication consists of either multiplication, addition, normalization, and rounding stage of the conventional floating-point multiplier requries a high speed adder for increment, increasing the overall execution time and occuping a large amount of chip area. A floating-point multiplier performing addition and IEEE rounding in parallel is designed by using the carry select addder used in the addition stage and optimizing the operational flow based on the charcteristics of floating point multiplication operation. A hardware model for the floating point multiplier is proposed and its operational model is algebraically analyzed in this paper. The proposed floating point multiplier does not require and additional execution time nor any high spped adder for rounding operation. Thus, performance improvement and cost-effective design can be achieved by this suggested approach.

  • PDF

A linear array SliM-II image processor chip (선형 어레이 SliM-II 이미지 프로세서 칩)

  • 장현만;선우명훈
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.2
    • /
    • pp.29-35
    • /
    • 1998
  • This paper describes architectures and design of a SIMD type parallel image processing chip called SliM-II. The chiphas a linear array of 64 processing elements (PEs), operates at 30 MHz in the worst case simulation and gives at least 1.92 GIPS. In contrast to existing array processors, such as IMAP, MGAP-2, VIP, etc., each PE has a multiplier that is quite effective for convolution, template matching, etc. The instruction set can execute an ALU operation, data I/O, and inter-PE communication simulataneously in a single instruction cycle. In addition, during the ALU/multiplier operation, SliM-II provides parallel move between the register file and on-chip memory as in DSP chips, SliM-II can greatly reduce the inter-PE communication overhead, due to the idea a sliding, which is a technique of overlapping inter-PE communication with computation. Moreover, the bandwidth of data I/O and inter-PE communication increases due to bit-parallel data paths. We used the COMPASS$^{TM}$ 3.3 V 0.6.$\mu$m standrd cell library (v8r4.10). The total number of transistors is about 1.5 muillions, the core size is 13.2 * 13.0 mm$^{2}$ and the package type is 208 pin PQ2 (Power Quad 2). The performance evaluation shows that, compared to a existing array processors, a proposed architeture gives a significant improvement for algorithms requiring multiplications.s.

  • PDF

A Parallel Operation System of the Z-Source Active Power Filter with Fuel Cells System (연료전지 Z-소스 능동전력필터의 병렬운전 시스템)

  • Oum, J.H.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.372-375
    • /
    • 2006
  • This paper proposes a parallel operation system of the Z-source active power filter using one fuel cells(FC) system. The proposed system is composed of two Z-source inverters operating in parallel only one PEM(Polymer Electrolyte Membrane)FC system. Also, as the control algorithm of the active power filter, a single phase P-Q theory and PI control are adopted. The effectiveness of the proposed the system is verified by the PSIM simulation in the steady state and the transient state.

  • PDF

Design and Parallel Operation of 30 kW SiC MOSFET-Based High Frequency Switching LLC Converter With a Wide Voltage Range for EV Fast Charger (전기자동차 급속충전기용 넓은 전압 범위를 갖는 30kW급 SiC MOSFET 기반 고속 스위칭 LLC 컨버터 설계 및 병렬 운전)

  • Lee, Gi-Young;Min, Sung-Soo;Park, Su-Seong;Cho, Young-Chan;Lee, Sang-Taek;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.165-173
    • /
    • 2022
  • The electrification trend of mobility increases every year due to the development of power semiconductor and battery technology. Accordingly, the development and distribution of fast chargers for electric vehicles (EVs) are in demand. In this study, we propose a design and implementation method of an LLC converter for fast chargers. Two 15 kW LLC converters are configured in parallel to have 30 kW rated output power, and the control algorithm and driving sequence are designed accordingly and verified. In addition, the improved power conversion efficiency is confirmed through zero-voltage switching (ZVS) of the LLC converter and reduction of turn-off loss through snubber capacitors. The implemented 30 kW LLC converters show a wide output voltage range of 200-950 V. Experiments applying various load conditions verify the converter performance.