• 제목/요약/키워드: A-Scan

Search Result 4,790, Processing Time 0.034 seconds

CLINICAL EFFECTIVENESS OF BONE SCAN FOR DIFFERENTIAL DIAGNOSIS OF JAW LESION (악골 병소의 감별 진단시 골스캔의 임상적 유용성)

  • Kim, Jeong-Mo;Kim, Chul-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.1
    • /
    • pp.33-41
    • /
    • 2007
  • Bone scan using radioactive isotope can be more effective than conventional X-ray radiograph for finding jaw lesion because it takes an image of the physiologic change of bone. This study is designed to show how available bone scan is able to diagnose jaw lesion better than simple X-ray and CT, as well as to determine a basis of diagnosis for jaw lesion using bone scan. The 77 patients, visiting the Oral & Maxillofacial Surgery, Department of Dankook University Hospital from January 2002. to August 2005. who were diagnosed histopathologically with postoperative malignant tumor, osteomyelitis, and bone infiltrative benign disease. Preoperative X-ray, CT, bone scan were taken and were compared with histopathologic finding. Also to compare specificty of each lesion in bone scan, bone density was measured to compare. The results were as follows. 1. Among the 25 cases of oral malignant tumor of bony invasion, a positive diagnosis associated with histopathologic evaluation, 22 cases(88%) in bone scan, 14 cases(56%) in CT image, and 10 cases40%) in simple X-ray. 2. Among the 31 cases of osteomyelitis, a positive diagnosis associated with histopathologic evaluation, 30 cases(97%) in bone scan, 23 cases(74%) in CT image, and 19 cases(61%) in simple X-ray. 3. Among the 11cases of bone infiltrative benign disease, a positive diagnosis associated with histopathologic evaluation, 11 cases(100%) in bone scan, 10 cases(91%) in CT image, and 6 cases(55%) in simple X-ray. 4. Measurement of bone density in each group showed no statistical significant difference between malignant tumor and osteomyelitis as well as benign bone disease. But, a statistical significance was seen between osteomyelitis and benign bone disease. From this results, bone scan are more sensitive than simple X-ray and CT image in jaw lesion diagnosis, but specificity shows no significant difference. Therefore, it should be suggested that evaluation of bone scan must be carrying out in reference to final histopathologic diagnosis.

Transition State Characterization of the Low- to Physiological-Temperature Nondenaturational Conformational Change in Bovine Adenosine Deaminase by Slow Scan Rate Differential Scanning Calorimetry

  • Bodnar, Melissa A.;Britt, B. Mark
    • BMB Reports
    • /
    • v.39 no.2
    • /
    • pp.167-170
    • /
    • 2006
  • Bovine adenosine deaminase undergoes a nondenaturational conformational change at $29^{\circ}C$ upon heating which is characterized by a large increase in heat capacity. We have determined the transition state thermodynamics of the conformational change using a novel application of differential scanning calorimetry (DSC) which employs very slow scan rates. DSC scans at the conventional, and arbitrary, scan rate of $1^{\circ}C/min$ show no evidence of the transition. Scan rates from 0.030 to $0.20^{\circ}C/min$ reveal the transition indicating it is under kinetic control. The transition temperature $T_t$ and the transition temperature interval ${\Delta}T$ increase with scan rate. A first order rate constant $k_1$ is calculated at each $T_t$ from $k_1\;=\;r_{scan}/{\Delta}T$, where $r_{scan}$ is the scan rate, and an Arrhenius plot is constructed. Standard transition state analysis reveals an activation free energy ${\Delta}G^{\neq}$ of 88.1 kJ/mole and suggests that the conformational change has an unfolding quality that appears to be on the direct path to the physiological-temperature conformer.

A Method for Quantifying the Risk of Network Port Scan (네트워크 포트스캔의 위험에 대한 정량화 방법)

  • Park, Seongchul;Kim, Juntae
    • Journal of the Korea Society for Simulation
    • /
    • v.21 no.4
    • /
    • pp.91-102
    • /
    • 2012
  • Network port scan attack is the method for finding ports opening in a local network. Most existing IDSs(intrusion detection system) record the number of packets sent to a system per unit time. If port scan count from a source IP address is higher than certain threshold, it is regarded as a port scan attack. The degree of risk about source IP address performing network port scan attack depends on attack count recorded by IDS. However, the measurement of risk based on the attack count may reduce port scan detection rates due to the increased false negative for slow port scan. This paper proposes a method of summarizing 4 types of information to differentiate network port scan attack more precisely and comprehensively. To integrate the riskiness, we present a risk index that quantifies the risk of port scan attack by using PCA. The proposed detection method using risk index shows superior performance than Snort for the detection of network port scan.

New IEEE 1149.1 Boundary Scan Architecture for Multi-drop Multi-board System (멀티 드롭 멀티 보드 시스템을 위한 새로운 IEEE 1149.1 경계 주사 구조)

  • Bae, Sang-Min;Song, Dong-Sup;Kang, Sung-Ho;Park, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.11
    • /
    • pp.637-642
    • /
    • 2000
  • IEEE 1149.1 boundary scan architecture is used as a standard in board-level system testing. The simplicity of this architecture is an advantage in system testing, but at the same time, it it makes a limitation of applications. Because of several problems such as 3-state net conflicts, or ambiguity issues, interconnect testing for multi-drop multi-board systems is more difficult than that of single board systems. A new approach using IEEE 1149.1 boundary scan architecture for multi-drop multi-board systems is developed in this paper. Adding boundary scan cells on backplane bus lines, each board has a complete scan-chain for interconnect test. This new scan-path insertion method on backplane bus using limited 1149.1 test bus less area overhead and mord efficient than previous approaches.

  • PDF

No-Holding Partial Scan Test Mmethod for Large VLSI Designs (대규모 집적회로 설계를 위한 무고정 부분 스캔 테스트 방법)

  • 노현철;이동호
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.3
    • /
    • pp.1-15
    • /
    • 1998
  • In this paper, we propose a partial scan test method which can be applied to large VLSI designs. In this method, it is not necessary to hold neither scanned nor unscanned flip-flops during scan in, test application,or scan out. This test method requires almost identical design for testability modification and test wave form when compared to the full scan test method, and the method is applicable to large VLSI chips. The well known FAN algorithm has been modified to devise to sequential ATPG algorithm which is effective for the proposed test method. In addition, a partial scan algorithm which is effective for the proposed test method. In addition, a partial algorithm determined a maximal set of flip-flops which gives high fault coverage when they are unselected. The experimental resutls show that the proposed method allow as large as 20% flip-flops to remain unscanned without much decrease in the full scan fault coverage.

  • PDF

The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT (PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가)

  • Kim, Jin-Young;Lee, Seung Jae;jung, Suk;Park, Min-Soo;Kang, Chun-Goo;Im, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose Among various causes that influence image quality degradation, various methods for decrease in Artifact occurred by respiration of patients are being used. Among them, this study intended to evaluate CTAC Shift correction method and additional scan compare to the Scan(Q static scan) using respiratory gated system. Materials and Methods This study was conducted on 10 patients, and used PET-CT Discovery 710 (GE Healthcare, MI, USA) and Varian's RPM system. 5.18 Mbq per kg of $^{18}F$-FDG was injected on patients, asked them to take a rest for 1 hour in the bed, and conducted test after urination. Images were visualized through Q static scan, CTAC Shift correction method, Additional scan based on the Whole body scan(WBS) with Artifact. Decrease in Artifact was compared in each image, conducted Gross Evalution, and measured changes of SUVmax. Results For image obtained through the CTAC Shift correction method through WBS with Artifact, 12~56%, Q static scan image showed 17~54% of change rate and Additional Scan showed -27~46% of change rate. In Blind Test, the CTAC Shift correction image showed the highest point with 4 points, Q static scan image showed 3.5 points, and Additional scan image showed 3.4 points. The standardized WBS scan through Oneway ANOVA and three types of Scan method showed significant difference(p<0.05), and did not show significant difference between the three Scan methods(p>0.05). However, the three Scan methods showed significant difference in Blind test. Conclusion Additional scan and Q static scan require more time than the CTAC Shift correction method, there is concern about excessive exposure to patients by CT rescan and Q static scan is difficult to apply on patients with inconsistent respiration or irregular respiration cycle due to pain. For CTAC Shift correction method, limited correction is possible and the range is limited as well. It is considered as a useful method of improving diagnostic value when hospitals use the system appropriately and develop various advantageous factors of each method.

  • PDF

Low Power Test for SoC(System-On-Chip)

  • Jung, Jun-Mo
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.6
    • /
    • pp.729-732
    • /
    • 2011
  • Power consumption during testing System-On-Chip (SOC) is becoming increasingly important as the IP core increases in SOC. We present a new algorithm to reduce the scan-in power using the modified scan latch reordering and clock gating. We apply scan latch reordering technique for minimizing the hamming distance in scan vectors. Also, during scan latch reordering, the don't care inputs in scan vectors are assigned for low power. Also, we apply the clock gated scan cells. Experimental results for ISCAS 89 benchmark circuits show that reduced low power scan testing can be achieved in all cases.

Scan Cell Grouping Algorithm for Low Power Design

  • Kim, In-Soo;Min, Hyoung-Bok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.130-134
    • /
    • 2008
  • The increasing size of very large scale integration (VLSI) circuits, high transistor density, and popularity of low-power circuit and system design are making the minimization of power dissipation an important issue in VLSI design. Test Power dissipation is exceedingly high in scan based environments wherein scan chain transitions during the shift of test data further reflect into significant levels of circuit switching unnecessarily. Scan chain or cell modification lead to reduced dissipations of power. The ETC algorithm of previous work has weak points. Taking all of this into account, we therefore propose a new algorithm. Its name is RE_ETC. The proposed modifications in the scan chain consist of Exclusive-OR gate insertion and scan cell reordering, leading to significant power reductions with absolutely no area or performance penalty whatsoever. Experimental results confirm the considerable reductions in scan chain transitions. We show that modified scan cell has the improvement of test efficiency and power dissipations.

A PRELIMINARY STUDY ON QUANTITATIVE ANALYSIS USING THE COMPUTERIZED T-SCAN SYSTEM (COMPUTERIZED T-SCAN SYSTEM을 이용한 정량적 교합분석방법에 관한 연구)

  • Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.271-277
    • /
    • 1989
  • The purpose of this preliminary report was to describe the operating procedure of T-scan system and to identify the location, timing and force of occlusal contact in patient with normal occlusion using computerized T-scan system. From the preliminary observation , the author obtained the following results. 1. T-scan system displayed 2 dimensional and 3 dimensional description of occlusion: contact locations, timing (sequence) and forces of occlusal contacts. 2. The T-scan sensor was the most important part of the T-scan system. 3. The data of T-scan system cannot be stored in computer diskett. 4. The T-scan system is thought to be the most effective system to detect occlusal contacts and can be applied to the followings : occlusal diagnosis, occlusal equilibration, crown and bridge restorative procedures, denture adjustment, implant procedures, splint adjustment, laboratory procedures, periodontal treatment, orthodontics, TMJ treatment and patient education etc.

  • PDF

Low Power Scan Test Methodology Using Hybrid Adaptive Compression Algorithm (하이브리드 적응적 부호화 알고리즘을 이용한 저전력 스캔 테스트 방식)

  • Kim Yun-Hong;Jung Jun-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.4
    • /
    • pp.188-196
    • /
    • 2005
  • This paper presents a new test data compression and low power scan test method that can reduce test time and power consumption. A proposed method can reduce the scan-in power and test data volume using a modified scan cell reordering algorithm and hybrid adaptive encoding method. Hybrid test data compression method uses adaptively the Golomb codes and run-length codes according to length of runs in test data, which can reduce efficiently the test data volume compare to previous method. We apply a scan cell reordering technique to minimize the column hamming distance in scan vectors, which can reduce the scan-in power consumption and test data. Experimental results for ISCAS 89 benchmark circuits show that reduced test data and low power scan testing can be achieved in all cases. The proposed method showed an about a 17%-26% better compression ratio, 8%-22% better average power consumption and 13%-60% better peak power consumption than that of previous method.

  • PDF