• 제목/요약/키워드: A flow constant

검색결과 1,889건 처리시간 0.03초

DEFORMATION OF CARTAN CURVATURE ON FINSLER MANIFOLDS

  • Bidabad, Behroz;Shahi, Alireza;Ahmadi, Mohamad Yar
    • 대한수학회보
    • /
    • 제54권6호
    • /
    • pp.2119-2139
    • /
    • 2017
  • Here, certain Ricci flow for Finsler n-manifolds is considered and deformation of Cartan hh-curvature, as well as Ricci tensor and scalar curvature, are derived for spaces of scalar flag curvature. As an application, it is shown that on a family of Finsler manifolds of constant flag curvature, the scalar curvature satisfies the so-called heat-type equation. Hence on a compact Finsler manifold of constant flag curvature of initial non-negative scalar curvature, the scalar curvature remains non-negative by Ricci flow and blows up in a short time.

진동하는 Taylor-Couette 유동에 대한 수치적 연구 (NUMERICAL STUDY OF MODULATED TAYLOR-COUETTE FLOW)

  • 강창우;양경수
    • 한국전산유체공학회지
    • /
    • 제15권4호
    • /
    • pp.32-39
    • /
    • 2010
  • In this study, we consider Taylor-Couette flow with the outer cylinder at rest and the inner one oscillating with a mean angular velocity. Varying the mean angular velocity, amplitude and frequency of the oscillation, we investigate the characteristics of modulated Taylor vortices. At a constant mean angular velocity, Taylor vortices intensify as the amplitude increases and frequency decreases. The axial wavenumber is calculated by spectral analysis. When the frequency varies, the axial wavenumber does not change at a constant mean angular velocity and amplitude. But, the axial wavenumber increases, as the mean angular velocity increases.

a-SiNx:H 박막의 제조 및 특성 (Fabrication and Characteristics of a-SiNx:H Thin Films)

  • 박욱동;김영진;김기완
    • 센서학회지
    • /
    • 제4권2호
    • /
    • pp.58-63
    • /
    • 1995
  • $SiH_{4}$$NH_{3}$의 RF 글로우방전 분해에 의한 PECVD법으로 a-SiNx:H박막을 제조하고 기판온도, RF 전력, 그리고 $NH_{3}/SiH_{4}$ 유량비 등의 변화에 따른 a-SiNx:H 박막의 유전상수와 광학적 밴드갭 등을 조사하였다. a-SiNx:H막의 유전상수와 광학적 밴드갭은 기판온도, RF 전력 및 $NH_{3}/SiH_{4}$ 유량비 등의 증착변수에 따라 크게 변화하였다. 기판온도가 증가할수록 a-SiNx:H막의 유전상수는 증가하였으며 광학적 밴드갭은 감소하였다. 기판온도, RF 전력, 가스압력, $NH_{3}/SiH_{4}$ 유량비 및 두께를 각각 $250^{\circ}C$, 20 W, 500 mTorr, 10 및 $1500\;{\AA}$로 하였을 때 a-SiNx:H막의 유전상수, 절연파괴전장 및 광학적 밴드갭은 각각 4.3, 1 MV/cm 및 2.9 eV로 나타났다.

  • PDF

DEMS(Diethoxymethylsilane) precursor를 이용한 PECVD 저유전물질 박막증착연구 (The study on low dielectric thin film deposition using DEMS precursor by PECVD)

  • 강민구;김대희;김영철;서화일
    • 반도체디스플레이기술학회지
    • /
    • 제7권4호
    • /
    • pp.35-39
    • /
    • 2008
  • We studied deposition of low-k SiOCH dielectric film by PECVD. DEMS(diethoxymethlysilane) precursor, which has two ethoxy groups along with one methyl group attached to the silicon atoms, was used as precursor. The SiOCH film was deposited as a function of oxygen flow rates ranging from 0 to 100sccm. The deposition rate($\AA$/min) of SiOCH film was increased due to the increase of oxygen radical as a function of $O_2$ flow rates. The dielectric constant was decreased from 3.0 to 2.77, as the film was annealed at $450^{\circ}C$ for 30 min. So, it could account that the dielectric constant changes sensitively with $O_2$ flow rates. Also, the leakage current of the annealed film exhibited stable curve than that of asdeposited. These results were caused by the increase of Si-O-Si group and decrease of Si-CH group and OH group within the film by annealing.

  • PDF

열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향 (An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe)

  • 최우석;박이동;김철주;황영규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

유체력을 이용한 직동식 비례 유량 조절 밸브에 관한 연구 (A Study on a Direct-Type Proportional Flow Control Valve Utilizing Flowforces)

  • 배상기;현장환;이정오
    • 한국정밀공학회지
    • /
    • 제15권4호
    • /
    • pp.68-75
    • /
    • 1998
  • A one-stage direction and flow control valve was studied theoretically and experimentally. A direction and flow control valve maintains a constant flow rate by changing the spool-orifice area under the variation of valve pressure drop, since the spool-orifice area is varied by the action of flowforces on the spool. A direction and flow control valve has the advantage of simple and low-cost structure compared to a conventional flow control valve utilizing a pressure regulating spool which regulates the pressure drop caused by flow through the metering orifice. The static and dynamic characteristics of a one-stage direction and flow control valve was analyzed. Experimental results on the flow control characteristics of the manufactured valve show satisfactory agreement with simulation results.

  • PDF

압력에 따른 평행박막 밸브의 자율 변형을 이용한 수동형 유량 제어기의 동적특성 평가 (Dynamic Characterization of Passive Flow-Rate Regulator Using Pressure-Dependent Autonomous Deflection of Parallel Membrane Valves)

  • 도일;조영호
    • 대한기계학회논문집B
    • /
    • 제35권8호
    • /
    • pp.825-829
    • /
    • 2011
  • 본 연구에서는, 미소유체시스템 상에서 정밀한 유체 제어를 위해 입력압력이 변하여도 일정한 유량을 유지할 수 있는 수동형 유량제어기를 개발함에 있어, 주기적으로 변화하는 압력에 대한 유량제어기의 동적특성을 평가하였다. 압력 변화의 주기보다 짧은 시간 내에 유량을 측정하기 위하여 입자영상속도계(Particle Image Velocimetry, PIV) 방법을 이용하였다. 지름이 $0.7{\mu}m$ 인 형광입자가 담긴 탈이온수를 유량제어기에 공급하고, 펄스레이저와 형광현미경을 이용하여 $10{\mu}s$ 간격의 연속된 사진을 얻고 이를 분석하여 유량제어기를 통과한 후의 유체의 속도를 측정하였다. 개발된 유량제어기는 20kPa 과 50kPa 사이를 주기적으로 변화하는 60Hz 의 압력 하에서 0.194${\pm}$0.014m/s의 일정한 유속을 유지함을 실험적으로 확인하였다. 압력의 주파수를 1~60Hz 까지 변화시켜가며 수행한 실험에서도 유량제어기는 압력의 주파수에 상관없이 $5.82{\pm}0.29\;{\mu}l/s$ 의 일정한 유량 공급이 가능함을 확인하였다.

마이크로히터에서 반주기 정현곡선의 열부하에 의한 비정상 열전달 연구 (NUMERICAL STUDY OF UNSTEADY HEAT TRANSFER ON MICRO HEATER UNDER HALF-CYCLE SINUSOIDAL HEAT LOAD)

  • 김명준;이희준
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.1-7
    • /
    • 2014
  • A numerical study of transient conjugate heat transfer on micro heater in a micro-channel substrate under a sinusoidal heat load was conducted. It was found that the time constant is not affected by the maximum heating magnitude of the sinusoidal heat load. However, the time constant increases with low duration of the sinusoidal heating period and low Reynolds number. Moreover, there is a threshold where a heater temperature do not reach to time constant at low thermal diffusivity, low flow rate, and low pulse duration of the sinusoidal heating. The time constant should be considered for transient convective heat transfer under transient sinusoidal heat load in a micro heat sink.

하비갑개 수술 후 비강 모델 내의 세부 유동장의 실험 및 전산 유동가시화 (Experimental and Numerical Flow Visualization on Detailed Flow Field in the Post-surgery Models for the Simulation of the Inferior Turbinectomy)

  • 장지원;허고은;김성균
    • 한국가시화정보학회지
    • /
    • 제9권3호
    • /
    • pp.65-70
    • /
    • 2011
  • Three major physiological functions of nose can be described as air-conditioning, filtering and smelling. Detailed knowledge of airflow characteristics in nasal cavities is essential to understanding of the physiological and pathological aspects of nasal breathing. In our laboratory, a series of experimental investigations have been conducted on the airflows in normal and abnormal nasal cavity models by means of PIV under both constant and periodic flow conditions. In this work, more specifically experimental and numerical results on the surgically modified inferior turbinate model were presented. With the high resolution CT data and a careful treatment of the model surface under the ENT doctor's advice yielded quite sophisticated cavity models for the PIV experiment. Physiological nature of the airflow was discussed in terms of velocity distribution and vortical structure for constant inspirational flow. Since the inferior and middle turbinate are key determinants of nasal airflow, the turbinectomy obviously altered the main stream direction. This phenomenon may cause local changes in physiological function and the flow resistance.