• Title/Summary/Keyword: A flow constant

Search Result 1,878, Processing Time 0.025 seconds

The analysis of the low-flow statistics using regression model at the Chonbuk regional ungaged basin (회귀모형을 이용한 전북지역 미계측 유역의 저유량 해석)

  • 조기태;박영기;이장춘
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.13-18
    • /
    • 2000
  • The purpose of this study is to estimate the low-flow statistics at the mountainous watershed. The formulation for the estimation of the design low-flow statistics was obtained by means of a hydraulic approach applied to a simple conceptual model for a mountainous watershed. Three of the independent variables associated with the low-flow statistics is watershed area(A), average basin slope(S) and the base flow recession constant(K); Watershed area was measured from topographic maps and average basin slope is approximated in this study using Strahler's slope determining method. And base flow recession constant computed using Vogel and Kroll's method. Unfortunately, this method is usually unavailable at ungaged sites. In this study, recession constant at ungaged sites is estimated using graphical regression method used by Giese and Mason. The model for estimating low-flow statistics were applied to all 61 catchments in the Sumjin, Mankyung basin.

  • PDF

A Modified Fractional Step Method of Keeping a Constant Mass Flow Rate in Fully Developed Channel and Pipe Flows

  • You, Jong-Woo;Choi, Hae-Cheon;Yoo, Jung-Yul
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.547-552
    • /
    • 2000
  • The objective of this paper is to present a modified fractional step method of keeping a constant mass flow rate in spatially periodic flows, because original fractional step methods do not precisely keep the mass flow rate constant in time. In the modified method, the mean and fluctuating pseudo-pressure gradients are separately obtained at each time step. This method is successfully applied to channel and pipe flows and shown to be suitable for maintaining a constant mass flow rate in time.

  • PDF

A Study on the Correction Factor of Flow Angel by using the One Dimentional Performance Model of Torque Converter (토크 컨버터의 1차원 성능 모델을 이용한 유동 각도 보정 계수에 관한 연구)

  • Im, Won-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.506-517
    • /
    • 2000
  • One dimensional performance model has been used for the design of torque converter. The model is based on the concept of constant mean flow path and constant flow angle. These constant-assumed para meters make the design procedure to be simple. In practice, some parameters are usually replaced with geometric raw data and, the constant experiential correction factors have been used to minimize the design error. These factors have no definite physical meaning and so they cannot be applied confidently to the other design condition. In this study, the detail dynamic model of torque converter is presented to establish the theoretical background of correction factors. To verify the validity of theoretical model, steady state performance test was carried out on the several input speed. The oil temperature effect on the performance is analysed and adjusted. The constant equivalent flow angles are determined at a part of performance region by comparing the theoretical model and the test data. The sensitivity of correction factors to the input speeds are studied and the change of torus flow is presented.

Natural Convection of Air in a Horizontal Annulus with the Inner Cylinder Cooled by Constant Heat Flux (일정 열 유속으로 냉각되는 안쪽 실린더를 갖는 수평 환형 공간에서의 공기의 자연 대류)

  • 유주식;엄용균;김용진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.755-762
    • /
    • 2000
  • Natural convection of air in a horizontal annulus with the inner cylinder cooled by the application of a constant heat flux and the isothermally heated outer cylinder is considered. The bifurcation phenomenon of flow patterns and the heat transfer characteristics are numerically investigated. The zero initial condition induces a unicellular flow in a half annulus. A bicellular flow consisting of two counter-rotating eddies in a half annulus can be obtained above a certain critical Rayleigh number. A transition from the bicellular to the unicellular flow occurs with a decrease in Rayleigh number. Hysteresis phenomena have not been observed. In the regime of dual flows, the overall Nusselt number of the bicellular flow is greater than that of the unicellular flow.

  • PDF

CFD for Y-type Constant Flowrate Valve Design (Y형 세대별 정유량 밸브 개발에서의 CFD의 활용)

  • Kwon, U-Cheol;Lee, Byeong-Huee
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.488-491
    • /
    • 2004
  • Numerical analysis of the three dimensional turbulent flow field in a complex valve shape is carried out to confirm the flow field whether the designed valve shape is good or not. The simulation of the incompressible flow in a constant flowrate control valve is performed by using the commercial code, FLUENT/UNS 6.0. The results of flow field show the designed valve has some problems, therefore these will be good data for new valve design.

  • PDF

Changes in Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation: an In Vitro Study

  • Lee, Chong-Sun;Kim, Joo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.193-197
    • /
    • 2005
  • Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of intracranial pressure pulsation on their flow control characteristics. Five commercial shunt valves were tested in the flow loop that simulates pulsed flow under pressure pulsation. As 20cc/hr of flow rate was adjusted at a constant pressure, application of $40mmH_2O$ of pressure pulse increased the flow rate by $67.9\%.$ As a 90cm length catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to $17.5\%.$ As the flow rate was adjusted to 40cc/hr at a constant pressure, increase in the flow rate was $51.1\%$ with the same pressure pulsation of $40mmH_2O$. The results indicated that pressure-flow control characteristics of shunt valves implanted above human brain ventricle is quite different from those obtained by syringe pump test at constant pressures right after manufacture. The influence of pressure pulsation was observed to be more significant at low flow rate and the flexibility of the outlet silicone catheter was estimated to significantly reduce flow increase due to pressure pulsation.

An Experimental Study of the Effect of Flow on Flame Propagation in a Constant-Volume Combustion Chamber (정적연소기내 유동형태가 화염전파에 미치는 영향 연구)

  • Jeong, D.S.;Oh, S.M.;Suh, S.W.;Chang, Y.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.2
    • /
    • pp.136-145
    • /
    • 1995
  • The aim of this study is to gain a better understanding of the effect of a flow motion on the flame development by means of an optically-accessible constant-volume combustion chamber and the visualization technique of a combustion flame. At first, the characteristics of a flame propagation are investigated in the combustion field of the two kinds of flow conditions such as a quiescent and a flowing condition, and methane-air mixture is used as fuel. Then the same investigation is performed in two flow configurations : bulk flow motion type and turbulence generating type. In this study, the combustion phenomena are analyzed by measuring the combustion pressure, flame propagation speed, mean velocity, turbulent intensity, and mass fraction burned.

  • PDF

System-level Analysis of a Fan-motor Assembly for Vacuum Cleaner (진공청소기용 팬-모터 어셈블리의 시스템-레벨 분석)

  • Park, Chang-Hwan;Park, Kyung-Hyun;Chang, Kyung-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.5-14
    • /
    • 2017
  • A fan-motor assembly in a vacuum cleaner is analyzed through system-level analysis method. This system consisted of three components, a fan, motor, and the flow resistance of the motor, or of the vacuum cleaner. System-level analysis method is characterized by the combination of torque matching at a constant throttling condition between the fan and the motor and the pressure drop at a constant flow rate due to the flow resistance of the motor, or of the vacuum cleaner. The performance characteristics of the fan-motor assembly and the vacuum cleaner system could be predicted over the whole range of operation, based on the characteristics of each component. The predicted performance of the vacuum cleaner system through system-level analysis agreed well with the experimental results within 4.5% difference of pressure and 6% difference of the efficiency. The effect of flow resistance of a motor is investigated and it is found that the efficiency decrease of fan-motor assembly at the constant flow rate due to the flow resistance of a motor is determined by the flow resistance ratio(FRR), which is defined as a ratio of flow resistance of motor and the flow resistance of a constant throttling condition of a given point. The fan-motor assembly(S2 model) was modified to reduce the FRR from 9.0% to 2.4% and the experimental result shows that the efficiency of S2 model was improved by about 3% at best efficiency point.

An Experimental Study on the Depth Variation of Water Flow on Steep Open Channel with Constant Width (一定幅 急傾斜 開水路上을 流動하는 물의 깊이 變化에 관한 實驗的 硏究)

  • 박이동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.86-95
    • /
    • 1986
  • A study on film water flow on steep open channel has been seldom found up to date. Therefore, this paper dealed with the depth variation of film thickness of water (city supply normal water) flowing on steep open channel. For this purpose, Experimental apparatus (made of a normal glass with 160cm of length and 15cm of width) was made and the depths of the water flowing on the channel were measured experimentally, changing the channel slope angle from 30 to 80 degree (5 steps) and the flow rate from 0.25 to 10CPM (11 steps). The results obtained, some characteristics of the film flow on the channel are as follows. (1) When thin film water flowed on steep open channel, the depths of flow tended to increase after decreasing and was kept nearly constant in its downstream in case of laminar and transitional flow region. The turining point of the depths of flow from decrease to increase tended to move downward with the increase of Reynolds number. In turbulent flow region, the depths of flow showed reapid decrease in its upper stream, gradual decrease in its midstream and were kept nearly constant in its downstream. (2) While the differences between the depths of flow along the channel slope got small in its upper stream and got large in its downstream in case of laminar flow region, they got very large in its upper stream and were kept nearly constant in its downstream in case of transitional and turbulent flow region. And the move flow rate increases, the more the differences between the depths of flow along the channel slope got large in its upper stream.

TRIPLE SOLUTIONS IN NATURAL CONVECTION OF A FLUID IN A HORIZONTAL ANNULUS WITH CONSTANT TEMPERATURE WALLS (일정 온도 벽면을 갖는 수평 환형공간 내의 유체의 자연 대류에서의 삼중해)

  • Yoo, Joo-Sik
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.110-115
    • /
    • 2017
  • Natural convection of a fluid with the Prandtl number of 7(water) in a horizontal annulus with constant temperature walls is numerically investigated. The inner cylinder is hotter than the outer cylinder. The flows are classified by the number of eddies in a half annulus. It is found that dual or triple solutions exists above a critical Rayleigh number for an annulus with a aspect ratio $D_i/L=4$. Transitions of $3{\rightarrow}1$ and $2{\rightarrow}1$ eddy flow occur with decrease of Rayleigh number. However, reverse transitions of $1{\rightarrow}3$ and $1{\rightarrow}2$ eddy flow do not occur with increase of Rayleigh number, and no hysteresis phenomenon is observed. In the regime of triple solutions, the 3 eddy flow has the largest mean Nusselt number value and the 1 eddy flow has the smallest value.