• Title/Summary/Keyword: A Single System Design

Search Result 2,212, Processing Time 0.038 seconds

Comparison of Current Control Method for Single-phase PFC converter with 1-switch Voltage Doubler Strategy (단일 스위치 배전압 방식의 단상 PFC 컨버터의 전류 제어기법 비교)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Guee-Soo;Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • This paper describes the performance comparison results for current controller of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS(Uninterruptible Power Supply). A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of current controller design and comparison of current control method has not been known after the converter circuit was proposed. For the performance comparison of current control, single-phase 3 kVA double-conversion UPS was tested. The performance of PI and PR current controller is experimentally confirmed with followings - input current reference tracking, input power factor correction and input current THD suppression.

Design of Cascaded Fuzzy Controller (종속 퍼지 제어기 설계)

  • 정경권;류태욱;엄기환;이정훈;이용구;손동설
    • Proceedings of the IEEK Conference
    • /
    • 2001.06c
    • /
    • pp.185-188
    • /
    • 2001
  • In this paper, a cascade fuzzy control method is proposed, which presents a robustness of the effect of disturbances, and in which the number of rules of the controller increase linearly instead of exponentially with the number of input variables. The proposed fuzzy control method is composed of cascade structure. Each stage has a state and a change of state, and one consequent control variable, and previous consequent control variable is an input of next stage. Simulation of the proposed controller, which is applied to the linear and nonlinear system as SISO (single-input single-output) system, showed that the proposed control method has a good control performance and robustness of disturbances compared with a conventional fuzzy control method.

  • PDF

Design of a DC Motor Controller for FA (FA용 직류전동기 제어기 설계)

  • 오진석
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.49-57
    • /
    • 1994
  • In this paper, a speed controller using a controller is implemented and applied to a DC motor for FA ( Factory Automation ). The objective of this paper treats the analytical and experimental studies on the improvement of control circuit and control method using a SCR-LEONARD circuit for the speed control of DC motor. This system is concerned with stabilization of single input or single output systems, so the plant (SCR-LEONARD+DC motor) is simplified to the first order system. The parameters for the PID controller are obtained by the transient-response tunning method, and this control scheme has a backward-shift operator. The control algorithms (Chopper+transient response tunning) is used to check the performance of PID Controller through Computer simulations and experiments. The good experiment results show that the direct control of the DC motor applied to industrial field such oi factory automation.

  • PDF

Novel Interleaved Single-Stage AC/DC Converter with a High Power Factor and High Efficiency

  • Wang, Yijie;Wang, Wei;Zhang, Xiangjun;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.245-255
    • /
    • 2011
  • A novel single-stage AC/DC converter with the soft-switching characteristic based on interleaving technology and an LLC topology is proposed here. The converter is integrated by an interleaved cell and an LLC cell. Because the components of the system are reduced as a result of integrating, the cost decreases. Since interleaving technology is adopted, the converter can work in a high voltage input state. The LLC topology chosen here ensures that the switches on the primary side work in the ZVS condition and that the diodes on the secondary side work in the ZCS condition, which decreases the switching loss of the system. A theoretical analysis and the design procedures of the proposed converter are proposed and discussed in detail. Simulations and experimental studies with a 100W prototype are done to prove the analysis.

Implementation of an Efficient Algorithm for a Single Phase Matrix Converter

  • Gola, Ajay Kumar;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.198-206
    • /
    • 2009
  • An algorithm is developed that enables a single-phase matrix converter (SPMC) to perform functions of a generalized single phase power electronics converter such as acting as a frequency changer, rectifier, inverter, and chopper. This reduces the need for new converter hardware. The algorithm is implemented first on computer simulation software Orcad Capture CIS version 9.1. Simulation results are presented for five types of converters with a control input variable that decides the 1) type of converter and 2) type of output waveform. The simulated results verify the working and operation of a generalized converter based on SPMC. Simulated results are verified with experimental results. Hardware design is obtained using readily available ICs and other components. The trigger circuit has been tested qualitatively by observing waveforms on CRO. The operation of the proposed system has been found to be satisfactory.

A Study on the Design of Ship's Distributed Remote Control System Using Dual-Microprocessor (이중마이크로프로세서의 이용과 분산처리기법을 도입한 선박용 원격제어 시스템의 설계에 관한 연구)

  • 홍순철;정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.78-87
    • /
    • 1994
  • In this paper design and implementation of ship's distributed remote control system using dual-microprocessor is presented for real time process. The proposed system is implemented with the single chip microprocessors in tightly coupled mode and results in speed up of $s_p$=1.74. Under the assumption that the nodes are interconnected in multidrop, the overall system performance such as average throughout-delay characteristics and effective throughput are analyzed using M/G/1 queneing model, and results show that the proposed node can be used in medium sized distributed monitoring and control system.

  • PDF

A Design of Digital Signal Processing System for the Automatic Diagnosis of Electrocardiogram (심전도 자동진단장치를 위한 디지탈 신호처리시스템의 설계)

  • Lee, Jong-Young;Hwang, Sun-Chul;Kim, Yong-Man;Lee, Myoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1326-1328
    • /
    • 1987
  • This paper describes the design of digital signal processing system for the automatic diagnosis of ECG. The system comprises analog hardware, digital hardware, and control system by microcomputer. Also, since digital signal processing system can be equipped easily in microcomputer for the compact size(Single board), We expect to develop the Portable ECG Automatic Diagnosis System using this System.

  • PDF

Design and Fabrication of 1 MVA Single Phase HTS Transformer for Power Distribution with Natural Convection Cooling System

  • Kim, W. S.;Kim, S. H.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Park, J. H.;H. S. Son;S. Y. Hahn
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.149-152
    • /
    • 2004
  • The design and the fabrication of a 1 MVA single-phase HTS transformer are presented in this paper, The rated voltages are 22.9 ㎸ for primary and 6.6 ㎸ for secondary, and the rated currents are 44 A and 152 A respectively. The transformer has HTS double pancake type windings. This type of winding has many advantages such as ease of fabrication and maintenance, good distribution of surge voltage and insulation of windings. Single HTS wire was used for primary winding and four HTS parallel wires were used for secondary winding. These windings are arranged reciprocally with the shell type iron core. An FRP cryostat with room temperature bore was fabricated to isolate the iron core from the coolant. The winding will be cooled down to 65 K with sub-cooled liquid nitrogen using a GM-cryocooler. The sub-cooled liquid nitrogen has advantages of good insulation because of no bubbles as well as increased current capacity of HTS wire.

  • PDF

System Identification and Controller Design of a Small-scale Building Structure using Matlab (Matlab을 이용한 축소 모형건물의 시스템 식별과 제어기 설계)

  • Min, Kyung-Won;Kim, Sung-Choon;Hwang, Seong-Ho;Ho, Kyoung-Chan;Joung, Jin-Wook;Joo, Soek-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.978-983
    • /
    • 2000
  • This paper presents the system identification of a small-scale building model with an active mass driver and the controller design using Matlab program. As the AMD is a mechanical system which has a dynamic characteristic and whose mass can not be neglected compared to that of the building mass, the AMD-building interaction should be included in the controller design. The system identification is carried out for the AMD-building system with two acceleration inputs of the shaking table and the AMD and single acceleration output of the building. The mathematical model for the AMD-building is obtained and compared with the experimental result. The controller is designed based on the mathematical model using the optimal control algorithm of LQG strategy. The experimental results are compared with the numerical results. It is shown that both results are in good agreement in the system identification and the controlled responses.

  • PDF

An Experimental Study on Multi-Fault Detection and Diagnosis Analysis of HVAC System (HVAC 시스템의 중복고장 검출을 위한 실험적 연구)

  • Cho Sung-Hwan;Hong Young-Ju;Yang Hooncheul;Ahn Byung-Cheon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.932-941
    • /
    • 2004
  • The objective of this study is to detect the multi-fault of HVAC system using a new pattern classification technique. To classify the effect of single-fault in determining the pattern, supply air temperature, OA-damper, supply fan, and air flowrate were chosen as experimental parameters. The combination of supply temperature, flow rate, supply fan and OA-damper were chosen as multi-fault conditions. Three kinds of patterns were introduced in the analysis of multi-fault problem. To solve multi-fault problem, the new pattern classification technique using residual ratio analysis was introduced to detect the multi-fault as well as single-fault. The residual ratio could diagnose single-fault or multi-fault into several patterns.