• Title/Summary/Keyword: A Single Room

Search Result 738, Processing Time 0.023 seconds

A temperature sensor using single phase-vanadium dioxide thin films (single phase-vanadium dioxide 박막을 이용한 온도센서에 관한 연구)

  • Kim, Ji-Hong;Hong, Sung-Min;Kwak, Yeon-Hwa;Park, Soon-Seob;Hwang, Hak-In;Moon, Byung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.109-110
    • /
    • 2006
  • In bio applications, high temperature coefficient of resistance (TCR) at $30^{\circ}C{\sim}40^{\circ}C$ is especially important for a temperature sensor. In this work, single phase-vanadium dioxide ($VO_2$) thin films for temperature sensor were fabricated by reactive DC magnetron sputtering and post-annealing method. VOx thin films deposited by reactive sputtering in a controlled $Ar/O_2$ atmosphere can be transformed into single phase-$VO_2$ films by post-annealing in $N_2$ atmosphere. The grown $VO_2$ thin films have a moderate resistance at room temperature and very high TCR at room temperature and transition temperature, respectively 2.88%/K and 15.8%/K. A detailed structural characterization is performed by SEM, XRD and RBS. SEM morphology image indicates that grains of fabricated $VO_2$films are homogeneous and ball-like in shape. A fact that the films contain only single phase-$VO_2$ is obtained by XRD and RBS analysis. After deposition, the sensors were fabricated by micromachining technology. Silicon nitride membrane and black nickel were used for a thermal isolation structure and absorption layer. In the vicinity of room temperature, the TCR of sensors was enough high to apply for bio sensors.

  • PDF

An Experiment on Verification of Multi-Gas Tracer Technique for Air Exchange Rate Between Rooms (실간환기량 측정을 위한 멀티추적가스법의 검증실험)

  • Han, Hwa-Taik;Cho, Seok-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.99-104
    • /
    • 2007
  • Tracer gas technique is widely used to measure the ventilation rates and/or ventilation effectiveness of building spaces. However, the conventional method using a single tracer gas can measure only outdoor air change rates in a single zone. This paper deals with the multi-gas tracer technique to measure air exchange rates between rooms. Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Experiments are conducted in a simple two-room model with known airflow rates using tracer gases of SF6 and R134a. The concentration decays of two tracer gases are measured after simultaneous injections in each room. The governing equations are derived from the continuity and the mass balance of each room. The data reduction procedure are developed to obtain the inter-room airflow rates using the governing matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, smoothing, and etc, to improve the estimate and interpretation of the results.

  • PDF

A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit (중환자실 병상주변공간의 면적과 간격에 관한 연구)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

A Study on the Residential Environment Preference and Needs of the Multi-academic Young Single Family Based on Life Style (라이프스타일 기반 다학제적 청년층 1인 가구의 주거 환경 선호 및 요구 분석)

  • Lim, Jun Hyung;Choi, In Young;Park, Hey Kyung
    • Korea Science and Art Forum
    • /
    • v.37 no.1
    • /
    • pp.249-260
    • /
    • 2019
  • Recently, the proportion of single-person households is on the increase in Korea, expected to reach 34.6% in 2035. Among the single-person households, Young single family households are facing greater difficulties due to high house prices in Korea. The government is expanding its support to Young single family, executing various policies such as public lease housings, private lease housings for youth, youth dormitory, etc. The purpose of this study is to understand the exact housing requirement of Young single family households who have different lifestyles with other age groups and provide base line data for youth house planning which will be in use later on. Study methods are shown below. First, this research studied the status and characteristics of Young single family households by looking into literature. Second, by studying previous studies concerned with life style and housing preferences of youth, the tool for investigating preferences and needs of housing environment by Young single family households was composed. Third, survey on characterstics of space usage, preferences and needs on flat composition, and preferences of interior design were conducted based on lifestyle of Young single family-households. The survey was conducted as an online survey using SNS for 150 Young single family holds from the age of 20 and 39, including students and office workers from December 2018 to January 2019. The results are as following. (1) Looking into the space usage characteristics, considering that various activities other than basic functions take place in bedroom and living room of small-sized Young single family households, we need to consider this additionally when planning the housing. (2) Looking into the preferences and composite needs of flat composition, the subjects demand separate bed room and more living room space, and also demand expansion of living room space where various activities take place and additional storage such as dress room in bed room (3) The preferences toward interior design show preferences toward modern style and achromatic color, a representative color. The subjects also prefer floor finishing materials normally used for living spaces, and indirect, soft lighting that uses wall. Also, there are differences between interior design preferences between students (20's) and office workers(30's) due to their different lifestyles. Research is needed to propose practical residential environment requirements and plans through a case study of actual public rental housing and a wider range of users.

A Study on the Type of Plane at Hanok in Haengbok Village (행복마을 한옥의 평면 유형에 관한 연구)

  • Lee, Sang-Sun;Sung, Dae-Chul
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.2
    • /
    • pp.27-34
    • /
    • 2012
  • This study aims to examine and classify plane types of Hanok at Haengbok village, analyze changes, area distribution and space structures of space components and sort plane types and their characteristics. Plane types were divided into four; living room, kitchen, dining room, etc. These plane types were labelled as LK type, L+K type, L+DK type and LDK type. LK type and L+K type were mainly found at single-wing house and made of living room and kitchen centered space structure, but substantially they were designed to ensure guest room, room and living room. Therefore, hanok built at Haengbok village were designed to combine the functions of residential function and lodging. Plane type was preferred to be used for double functions of residence and lodging. On the other side, L+DK type and LDK type were mainly found in house with several wings and they were designed centering around living room for family space. In addition entrance was placed to simplify entry from the outside and each room and guest room were arranged to be accessed from living room. It means that the functions of house focused on residence rather than lodging and all rooms had the structure to be used as residential space in case of emergency.

Cooling Cycle for Energy Saving (에너지 절약용 냉방사이클)

  • Lee, Hung Joo;Kim, Yong Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.116-127
    • /
    • 1989
  • Research on reheating cooling cycle and its practical application have been made to prevent unequalized distribution of temperature and humidity of room due to lack of supply air volume and dewdrops on supply diffusers to be taken place as a result of lower temperature of supply air than that of dew point of room air in cooling cycle of constant air volume, single duct, single zone and draw-through fan type. In view of the fact that human body is insensitive to humidity, it is possible not only to construct the complete non-reheating cooling cycle by increasing the humidity point allowable with the deduction of occupant's sense of pleasantness minimizing, but also to get cooling cycle decreasing the reheating quantity if the humidity exceeds the point allowable. In addition, it is possible to save maximum 8% in electric energy for cooling in cooling system by constructing non-reheating cooling cycle instead of reheating cooling cycle and by increasing the relative humidity of room from 50% to 65% in case efficiency and air pressure of cooling system are low. It is also possible to get an optimum cooling cycle by determining the room humidity in consideration of pleasantness of occupants and conservation rate of electric energy if the cooling capacity, efficiency and total pressure of cooling equipment are fixed.

  • PDF

Architectural Improvement plans in a quarantine system for Senior facilities (노인요양시설 방역을 위한 시설 개선 방안)

  • Kang, Jeeeun;Kwon, Soonjung;Lee, Hyunjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.3
    • /
    • pp.61-69
    • /
    • 2021
  • Purpose: Senior long-term care facilities are vulnerable to a cluster infection because of frequent physical contact, large group dining, communal living, and room sharing. This study aims to provide architectural improvement plans for a quarantine system in the facilities. Methods: Actual quarantine action data, guidelines from governments and institutes, in-depth interviews with facility staff are analyzed. Results: To prevent a cluster infection in the senior facilities, it is necessary to provide an architectural plan focusing on increasing the number of single rooms and isolation rooms, providing isolation rooms for staff, separation of a soiled room from a clean room, planing an entry vestibule and a visitor's room. Implications: It is important to analyze the existing condition of facilities that had been going through cohort isolation and provide the architectural solution to strengthen infection control.

Development of Plant Abnormal Status Response System by Multi-Alarm Pattern in Main Control Room (원자력발전소 주제어실 다중 경보 패턴에 의한 경보/비정상 대응 체계 개발)

  • Choi, Sun Yeong;Jung, Wondea
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.129-135
    • /
    • 2014
  • The number of abnormal operation procedures (AOPs) for mitigating a plant abnormal status amounts to about one hundreds for the most of 1000MWe optimized power plant (OPR1000) and it is expected that the number of AOPs would be increased to cope with an abnormal status occurred newly. However, it is not well organized for operators to select a proper AOP from alarms occurred in main control room (MCR) during a plant abnormal status. It may be a burden to operators since the selection of AOP to respond an abnormal status is authorized by operators. When multiple alarms occur in MCR, it would take more time to respond them than a single alarm. To reduce the efforts, various MCR operation support systems have been developed. The purpose of this study was to develop a multi-alarm pattern card to select an appropriate AOP effectively when multiple alarms occurs in a single upper layout (UL) of MCR. It can be applied for an operation support tool as well as an education tool.

In-situ Determination of Absorption Coefficients in a Room

  • Suh, Jin-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.3E
    • /
    • pp.10-17
    • /
    • 2001
  • The possibility is investigated of determining the diffuse absorption coefficients of the wall surfaces in a real room by minimizing the errors between the measured energy impulse response of a real room and the predicted energy impulse responses obtained from the ray tracing simulation of the room. In other words, this can possibly serve as a basis for "acoustical system identification" in attempting to determine the "best fit" of modelled absorption coefficients to measured energy response data. Algorithms for attempting this were investigated. The algorithms developed for this purpose proved to be rigorous and efficient. Instead of using the ray tracing model to determine the absorption coefficients, the phase image model was used in order to determine the acoustic impedances of wall surfaces. However, the numerical algorithms could not find the correct impedance values, primarily due to the wide range of the acoustic impedance values of any single acoustic material and very long computation time.

  • PDF

A Study on the Thermal Pump of the Hot Water Boiler (온수 보일러용 열구동 펌프에 관한 연구)

  • Yeom, Han-Gil;Kim, Uk-Joong;Kim, Chang-Ju
    • 연구논문집
    • /
    • s.30
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF