• Title/Summary/Keyword: A Safety Device

Search Result 1,616, Processing Time 0.027 seconds

Basic Study on Safety Accident Prevention System Development Using Wearable Device (웨어러블 장치를 이용한 건설사고 예방 시스템 개발 기초 연구)

  • Ryu, Han-Guk;Kang, Jin-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.55-56
    • /
    • 2018
  • In order to reduce the risk of accidents, we proposed a construction safety management system combined with wearable device and LoRa (Low-Range Wireless Network) communication method to apply the usefulness of Internet (IoT) technology which means "everything connected". to construction safety management Management system. The proposed wearable safety device is a device that relays information exchange between wearable safety device and safety management server by LoRa wireless communication method. The safety management server can store workers bio-data and perform big data analysis. If a risk factor is determined from the analysis result, a warning is sent to the wearable safety device and the manager's application. The goal of this system is to prevent construction workers from entering the dangerous area that is not suitable for work, and to prevent safety accidents caused by human cause by detecting abnormal condition during work.

  • PDF

Realization of Logistics Safety Management System By Operating Advanced Vehicle Safety Management Device (첨단 차량 안전관리장치 운영을 통한 물류 안전관리시스템 구현)

  • Moon, Hoi-Kwon;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.2
    • /
    • pp.1-8
    • /
    • 2018
  • This study aims to provide a real-time information to the driver by effectively operating the advanced safety device attached to the freight vehicle, thereby minimizing insecure behavior of the driver such as speeding, rapid acceleration, sudden braking, And improve driving habits to prevent accidents and save energy. Advanced safety equipment is a device that warns the driver that the vehicle leaves the driving lane regardless of the intention of the driver and reduces the risk of traffic accidents by mitigating or avoiding collision by detecting a frontal collision during driving.The main contents of this report are as follows: In case of installing a warning device on a lane departing vehicle (excluding a light vehicle) and a lorry or special vehicle with a total weight exceeding 3.5 tonnes, the driver must continue to operate unless the driver releases the function.In addition, when the automatic emergency braking system is installed, the structure should be such that the braking device is operated automatically after warning the driver when the risk of collision with the running or stopped vehicle in the same direction is detected in front of the driving lane.

The Development for guideline of raw matrials on technical document of Medical Device (의료기기 허가.기술문서 원자재 작성 가이드라인 개발)

  • Park, Ki-Jung;Ryu, Gyu-Ha;Lee, Sung-Hee;Lee, Chang-Hyung;Jung, Jin-Baek;Lee, Jae-Keun;Hur, Chan-Hoi;Kim, Hyung-Bum;Choi, Min-Yong;Kim, Yong-Woo;Hwang, Sang-Yeon;Jung, Jae-Hoon;Koo, Ja-Jung;Hong, Hye-Kyung;Lim, Kyung-Taek;Kang, Se-Ku;Kwak, Young-Ji
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.434-437
    • /
    • 2010
  • For approval of medical devices manufactured or imported, submission of technical documents as well as the application form is required. The manufacturer (or importer) should properly identify the raw materials the applied product is made of and the manufacturing processes the product undergoes before it is shipped in the application form. In the technical documents, scientific data to evaluate the efficacy, safety, and quality of the applied product that has been described in the application form should be provided. Therefore, identifying the raw materials that were used for the parts of the applied product and describing the physical and chemical characteristics of the raw materials are quite important and essential in ensuring the efficacy, safety, and quality of the applied product. To describe the physical and chemical characteristics of the raw materials correctively, the applicant is required to have broad knowledge in the scientific fields such as chemical, polymer, metal, and ceramic science and engineering. But most of the applicant are not experts in these fields, so that the description in the application form often includes wrong and improper descriptions. Thus, we developed a guideline which explains the raw materials for medical devices, show the their examples. The purpose of this description guideline is to help the applicant properly completing the "Raw materials or constituents and their volumes" part in the application form.

Structural Analysis of Door Safety Device (도어 안전장치의 구조해석)

  • Lee, Jong-sun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.9
    • /
    • pp.173-177
    • /
    • 2019
  • This study is door safety device for the structural analysis are described. Recently emerged as a key point of the door safety and increase the need of a door safety device. In order to improvement this inconvenience, the door safety device was design and structural analysis by using CATIA. CATIA utilizes door safety device element model for displacement, stress and strain energy were obtained. Consideration of door open angles were $95^{\circ}$, $100^{\circ}$, $105^{\circ}$, $110^{\circ}$, $115^{\circ}$, $120^{\circ}$. These results will be provided to develop new concepts of door safety device as initial data.

A Study on Improvement of Submarine Torpedo Acoustic Counter Measure Launcher System Safety Device Performance (잠수함용 어뢰기만기 발사체계 안전장치 작동성능 향상에 관한 연구)

  • Chang, Ho-Seong;Seo, Dae-Su;Lee, Gyeong-Chan;Lee, Jong-Gwan;Jo, Byeong-Gi;Kim, Joong-Bae
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.411-424
    • /
    • 2018
  • Purpose: The purpose of this study is to improve submarine TACM launcher system safety device performance. Methods: In this study, EPLD(Electrically Programmable Logic Device) control and time sharing method to the safety device actuator motor and discrete signal processor in launch control panel were used to resolve unusual performance of safety system. Results: The result of this study are as follows; First, sporadic stopping of safety device actuator motor due to insufficient In-Rush current was resolved. Second, repeat of safety device condition as lock & release due to chattering for motor activating was resolved. Third, simultaneous release function for safety device actuator was available. Conclusion: The unusual performance of function for submarine TACM launcher system was overcame by applying EPLD control and time sharing method. The suggestions were proved by performance test in the pressure chamber. The results of this study enhanced survivability of ${\bigcirc}{\bigcirc}{\bigcirc}$ class submarine from enemy torpedo.

The Development of Assistant Device for the Standing X-ray Views and Its Usability for the Patient Safety (환자의 안전을 위한 입식 X선 촬영 보조기구 개발 및 유용성 평가)

  • Gil, Jong Won;Kim, Yong Gwon
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.223-229
    • /
    • 2015
  • In this study, We designed and implemented a assistant device for the standing X-ray views which is the one of the clinical X-ray imaging position. To evaluate the usability of the proposed assistant device, We choose 11 clinical patient postures that are used frequently and applied the postures to 5 volunteers. 11 images was taken from a volunteer for the patient postures. And we conducted a survey on safety and clinical usefulness, the 5 volunteers responded to the safety and 5 experts responded to the clinical usefulness. The survey results show that the volunteers feel more safe and the obtained images are very clear and clinically useful. The result for the image quality is 4.69 of 5(best) and safety is 2.84 of 3(best). It will be very profitable to both patients and hospitals by using the proposed assistant device.

A Development and Characteristics of Remote Emergency Stop Device for Conveyors (컨베이어용 리모트 비상정지장치 개발 및 특성)

  • Lee, Jun-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.14-19
    • /
    • 2011
  • Conveyors cause a high serious and fatal injuries in the industry. Every year people are hurt or killed as a result of accidents on conveyors. Most accidents occur during operation and maintenance when employees are working on moving, unguarded conveyors or when the conveyors starts unexpectedly. In 2008 there were 486 reported injures ranging from fatalities to injures. Of these 486 reported accidents, 8 were fatalities, 66.9%(325) of reported accidents occurred in manufacturing company and 43.8%(213) occurred at the belt conveyors. The objective of this study was to invent the remote emergency stop device because industrial accidents mainly occur at blind spots where usually do not have any safety guard or device rather than the normal working places. In principle, this new device will use with the existing safety system. Then, it will be powerful safety system for preventing injuries related with conveyors.

A Wearable Safety Device for the Body Protection of Motorcyclists (모터사이클 운전자 신체보호용 안전장치 개발 프로세스)

  • Jang, Dong-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.25-33
    • /
    • 2021
  • This paper presents the development process for airbag safety devices fitted in motorcyclists' garments. Motorcycle riders often sustain multiple injuries in crashes since rider post-impact kinematics depend on several variables. This study proposes a newly inflatable safety system connected to the motorcycle by a cable. An airbag device with a mechanical triggering system is deployed when the cable detaches from its mounting clip. Airbag filling tests are performed to determine the mixing ratio of compressed gases with the severance of temperature. To estimate the airbag effectiveness to reduce riders' injuries, numerical analysis is performed using the finite element method. A comparative analysis (i.e., with and without the chosen device) was conducted to evaluate its protective efficacy. Prototype garments based on the proposed design have been created and have undergone sled tests. The proposed safety device could also be beneficial in accidents during other sports activities.

Evaluation of dose received by workers while repairing a failed spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.442-448
    • /
    • 2022
  • Intermediate-level radioactive waste (ILW) is not subject to legal approval for cave disposal in Korea. To solve this problem, a spent resin treatment device that separates 14C-containing resin from zeolite/activated carbon and desorbs 14C through a microwave device has been developed. In this study, we evaluated the radiological safety of the operators performing repair work in the event of a failure in such a device treating 1 ton of spent resin mixture per day. Based on the safety evaluation results, it is possible to formulate a design plan that can ensure the safety of workers while developing a commercialized device. When each component of the resin treatment device can be repaired from the outside, the maximum and minimum allowable repair times are calculated as 263.2 h and 27.7 h for the 14C-detached resin storage tank and zeolite/activated carbon storage tank, respectively. For at least 6 h per quarter, the worker's annual dose limit remains within 50 mSv/year; further, over 5 years, it remained within 100 mSv. At least 6 h of repair time per quarter is considered, under conservative conditions, to verify the radiological safety of the worker during repair work within that time.

Development of an IoT Device for Detecting Escherichia coli from Various Agri-Foods and Production Environments (IoT 적용 대장균 검출기 개발과 농식품 및 생산환경에 적용)

  • Nguyen, Bao Hung;Chu, Hyeonjin;Kim, Won-Il;Hwang, Injun;Kim, Hyun-Ju;Kim, Hwangyong;Ryu, Kyoungyul;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.542-550
    • /
    • 2019
  • To detect Escherichia coli from agri-food and production environments, a device based on IoT (internet of things) technology that can check test results in real time on a mobile phone has been developed. The efficiency of the developed device, which combines an incubator equipped with a UV lamp, a high-resolution camera and software to detect E. coli in the field, was evaluated by measuring the device's temperature, detection limit, and detection time. The device showed a difference between its programmed temperature setting and actual temperature of about 1.0℃. In a detection limit test performed with a single-colony inoculation, a color change to yellow and a florescent signal were detected after 12 and 15 h incubations, respectively. The incubation time also decreased along with increasing bacteria levels. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, detection rates of E. coli using the device were higher than those of the Korean Food Code method. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.