• 제목/요약/키워드: A Rated Current

검색결과 511건 처리시간 0.022초

Regional Factors on the Self-rated Health of Wage Workers

  • Kwon, Minjung;Choi, Eunsuk
    • 지역사회간호학회지
    • /
    • 제29권1호
    • /
    • pp.21-32
    • /
    • 2018
  • Purpose: This study attempted to identify regional disparities of self-rated health among Korean wage workers and to investigate the influencing factors on them. Methods: The study subjects were 25,069 workers in 16 regions who were extracted from the 2014 Korean Working Condition Survey (KWCS). A multilevel analysis was conducted by building hierarchical data at individual and regional level. Results: In this study, 'financial autonomy rate' and 'current smoking rate' were identified as regional factors influencing the workers' self-rated health. When the socio-demographic and occupational factors of the workers were controlled, 'current smoking rate', a health policy factor, explained the regional disparity of workers' health status. Conclusion: We found that the health status of workers can be affected by the health behavior level of the whole population in their residential area. In order to improve the health status of working population and to alleviate their regional health inequalities, it is necessary to strengthen macro and structural level interventions.

계통연계 분산전원의 새로운 단독운전 판별기법 (Novel Islanding Detection Method for Distributed Generation Interconnected with Utility Grid)

  • 배병열;이두영;고종선;최남섭;한병문
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.65-72
    • /
    • 2008
  • This paper describes the development of a novel islanding detection method, which uses the signal cross-corelation scheme between the injected reactive current and the power frequency deviation. The existing method, which injects the reactive current of 2.5-5% to the rated current and detects the frequency deviation directly, brings about lowing the power quality due to the harmonic pollution. The proposed method eliminates the weak point of the existing method, because it injects the reactive current less than 1% to the rated current. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 10kVA hardware prototype. The proposed method can detect the islanding status effectively without lowing the power quality of interconnected distributed generation system.

전류인가시간에 따른 Bi-2223 테이프의 과전류 통전특성 측정 (Measurement of Bi-2223 Tape's properties at Various Duration of the Over Current)

  • 이광연;이희준;차귀수;이지광
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.257-260
    • /
    • 2003
  • Bi-2223 tape is one of the most widely used HTS tapes for power application. This paper presents the basic properties such as temperature and resistivity rise of the Bi-2223 tape which is exposed to the over current. Temperature and resistivity were measured by E-type thermocouple and voltage taps. Results of the measurement showed that rise of voltage depended on the magnitude of the over current until several times of the rated current. When the current largely exceeded the rated current, rise of voltage depended on the magnitude of the resistivity of the Ag matrix because temperature of the matrix increased to a great extend.

  • PDF

LCC 공진형 컨버터 기반의 고효율 커패시터 충전기 설계기법 (Design Method of High Efficiency Capacitor Charger Based on LCC Resonant Converter)

  • 정송찬;송승호;최민규;류홍제
    • 전력전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.325-331
    • /
    • 2022
  • This study proposes a design method that minimizes a conduction loss of LCC resonant converter under rated condition. Through a simplified analysis of the waveform of the resonant current, the power transfer section and RMS value of the resonant current was analyzed mathematically and graphically. Based on this analysis, the design method that minimizes the RMS value of the resonant current is proposed. To demonstrate this method, this study designed a 7.5 kW (100 V, 75 A) capacitor charger based on LCC resonant converter and the design parameters were chosen according to the process of the design method. Then, the capacitor charger was implemented. An experiment was conducted to measure efficiency while satisfying design specifications under rated conditions. This design method was verified to be effective by achieving 97.7% maximum efficiency and design specifications under rated conditions.

전류영점 영역에서 파퍼식 SF6 가스차단기의 아크 컨덕턴스에 관한 연구 (A Study on Arc Conductance of Puffer Type SF6 GCB at Current Zero Period)

  • 정진교;송기동;이우영;김규탁
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.328-332
    • /
    • 2010
  • The SLF(Short Line Fault) breaking capability test for high voltage class $SF_6$ GCB(Gas Circuit Breaker) was conducted. Simplified LC resonant circuit test facility was used for SLF breaking test. During test, Test current was measured by Rogwski coil and arc voltage was measured by voltage divider. Arc conductance was calculated by using these test results before 200ns at current zero. Critical arc conductance value at rated voltage 145kV class is about 2.3mS regardless of breaking current magnitude and arc conductance value at rated voltage 170kV class is about 2.6mS.

대전류 측정용 마이크로-옴 분류기의 교정에 관한 연구 (Calibration of micro-ohm shunt used for large current measurement)

  • 김민규;김익균;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1862-1864
    • /
    • 2002
  • In this study, micro-ohm shunts with rated ac current of 2, 20, 80kA intended for use as an approved system for ac current measurement were calibrated according to IEC 60060. The scale factor and linearity were determined by comparison with the reference measuring system. Measurements of temperature rise due to the rated current was also investigated to analyze a temperature effect. One of the main goals was the determination of the measurement uncertainty of the shunt. The expanded uncertainty of the scale factor for the complete measuring system was satisfied with the STL(Short-circuit Testing Liaison) guide recognized tentatively.

  • PDF

Stabilizer-free 초전도 선재를 이용한 한류 소자 제작 및 특성 시험 (Fabrication and characterization of fault current limiting devices made of stabilizer-free coated conductors)

  • 임성우;박충렬;유승덕;김혜림;현옥배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.371-371
    • /
    • 2009
  • For the application of superconducting wires to fault current limiting devices, it is required that they have a high rated voltage when a fault occurs. Stabilizer-free coated conductors, particularly, shows a good performance for the high rated voltage, which is beyond 0.6 V/cm. In this study, using the stabilizer-free coated conductors, we made fault current limiting devices and examined their characteristics. Fault current limiting devices were fabricated with a shape of the cylinder of a mono-filar coil winding. Stabilizer-free coated conductors were wound along the mono-filar coil line and the terminal parts between the wire and metal were soldered using In solder. Two kinds of devices were fabricated by a different method in the terminal joint, one was made by a soldering and the other was made by a soldering-free joint. Critical currents and resistance at the joint parts were measured. In addition, long-time current flowing tests were also carried out for the characterization of the fault current limiting devices.

  • PDF

방열 조건에 따른 5W급 고출력 백색 LED 모듈의 광 특성 평가 (Evaluation of the Lighting Characteristics in High Power White LED Module with Cooling Condition)

  • 윤장희;염정덕
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.1-8
    • /
    • 2012
  • The performance and lighting characteristics of the LED depend on cooling condition because the power LED generates lots of heat. In this paper, the effect of the generated heat from power LED module on lighting characteristics and performance is measured and evaluated. For experiments, the transient temperature of a power LED module with cooling condition is measured. In addition, the temperature and lighting characteristics of the LED module are measured during the steady state. As a result, the cooling condition is less effective on the lighting characteristics of the LED module at rated current but the cooling condition extremely affects those of the LED module over the rated current. Because high temperature of the power LED module causes the low phosphor conversion, luminance efficiency becomes low and color temperature becomes high. When power LED module are driven over the rated condition, higher temperature is directly related to lighting characteristics and performance of the LED module rather than higher current.

낮은 저항의 IH 전용용기를 가열할 수 있는 유도 가열 컨버터와 코일 설계 (Design Methodology of Series Resonant Converter and Coil of Induction Heating Applications for Heating Low Resistance IH-Only Container)

  • 정시훈;박화평;정지훈
    • 전력전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.24-31
    • /
    • 2018
  • An induction heating (IH) resonant converter, as well as its coil design method, is proposed in this study to improve the heat capability of low- and high-resistance IH vessels. Conventional IH resonant converters have been designed only for heating high-resistance containers designed for IH application. Thus, the primary current in the resonant tank becomes extremely high to transfer the rated power when the converter heats the low-resistance vessel. As a result, the rated power cannot be transferred due to overcurrent flows against the rated switch current. Hence, the optimal number of coil turns and proper operating frequency to heat high- and low-resistance vessels are proposed in this study by analyzing an IH load model. Simulation and experimental results using a 2.4 kW prototype resonant converter and its IH coil validate the proposed design.

양수발전소 동기전동기의 기동제어 알고리즘에 관한 연구 (A study developing control algorithm for Pumped-Storage Synchronous motor drive)

  • 강승우;박신현;김장목;임익헌;류호선;김진성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.467-471
    • /
    • 2003
  • The large synchronous motor for the pumped-storage plant(or SFC : Static Frequency Converter) has to be brought up to 100$\%$ rated speed and synchronized with the AC power network. Starting the motor from rest is achieved by switching current into the stator winding so that interaction between this stator current and the rotor flux will cause the correct direction of torque to be developed so that the motor turns in the required direction. Starting ranges of the synchronous motor are divided into three regions. The first region Is at standstill, the second that is called by the forced commutation is from standstill to 5-8$\%$ of rated speed, and the third, which is called by the natural commutation, is from 5-8$\%$ of rated speed to 100$\%$ rated speed. So this paper describes three regions of the control techniques of the pumped-storage synchronous motor drive.

  • PDF