• 제목/요약/키워드: A Comparative Study

검색결과 13,578건 처리시간 0.232초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

한국토양(韓國土壤)의 유효인산량(有效燐酸量) 검정(檢定)을 위한 화학적(化學的) 방법(方法)에 대한 연구(硏究) (A Comparative Study on the Chemical Methods for the Determination of Available Phosphorus in Korean Soils)

  • 임선욱;정종배;사동민
    • Applied Biological Chemistry
    • /
    • 제29권1호
    • /
    • pp.62-72
    • /
    • 1986
  • 작물(作物)에 대한 토양(土壞)의 유효인산량(有效燐酸量)을 화학적(化學的)인 방법(方法)으로 빠르고 정확(正確)하게 검정(檢定)하는 것은 농경지(農耕地) 토양(土壤)의 화학적(化學的) 특성(特性)과 비옥도(肥沃度)를 위하여, 또는 인산시비량(燐酸施肥量)의 결정(決定)을 위하여, 또는 한편으로는 환경(環境)의 화학적(化學的) 평가(評價)와 토양성분(土壤成分)에 대한 화학적(化學的) 연구(硏究)를 위하여 요구(要求)되는 과제(課題)이다. 현재(現在) 토양(土壤)의 유효인산(有效燐酸)에 대한 화학적(化學的) 규정(規定)과 그의 측정방법(測定方法)은 여러 가지 사정(事情)에 의하여 변동(變動)되거나 다수(多數)의 상이(相異)한 방법(方法)이 제안(提案)되어 있으므로 최적(最適)의 측정방법(測定方法)을 확립(確立)하기 위하여는 토양(土壤)과 작물(作物)의 영양적(營養的) 특성(特性)을 기초(基礎)로 하여 광범위(廣範圍)의 실험적(實驗的)인 결과(結果)에서 도출(導出)되어야 할 것이다. 한국(韓國)에서의 토양유효인산(土壤有效燐酸)의 화학적(化學的) 측정방법(測定方法)은 현재(現在) 통일(統一)되어 있지 못하고 제안(提案)된 다수(多數)의 측정방법(測定方法)에 대하여 실험적(實驗的)으로 광범위(廣範圍)하게 검토(檢討)되지 못하였으므로 본(本) 연구(硏究)는 이러한 목적(目的)을 위하여 전국(全國) 다수지역(多數地域)(44점(點))의 전토양(田土壤)을 공시(供試)하여 작물재배(作物栽培)(옥수수)를 통한 인산흡수량(燐酸吸收量)을 측정(測定)하고 한편 상이(相異)한 10가지 화학적(化學的) 방법(方法)으로 분석(分析)한 결과(結果)로써 적합(適合)한 방법(方法)을 확립(確立)하고저 하였으며 현재(現在)까지의 시험결과(試驗結果)를 다음과 같이 종합(綜合)한다. 공시토양(供試土壤)의 전인산량(全燐酸量)은 533ppm으로부터 4,917ppm까지의 넓은 범위에 있었으며 유기물(有機物) 함량(含量)과 유의성(有意性)있는 정(正)의 상관(相關)을 보였다. 특이산성토(特異酸性土)와 화산회토(火山灰土)는 공(共)히 유기물함량(有機物含量)은 높았으나 전인산량(全燐酸量)은 전자(前者)는 비교적(比較的) 낮았고 후자(候者)는 매우 높았다. 추출조건(抽出條件)이 상이(相異)한 10가지 화학적(化學的) 방법(方法)으로 측정(測定)한 유효인산(有效燐酸)으로 규정(規定)되는 양(量)은 방법간(方法間)에 다소(多少)의 차이(差異)가 있었으며 1%로부터 48%의 범위(範圍)에 있었다. 각(各) 방법(方法)으로 측정(測定)한 인산량(燐酸量)을 상호비교(相互比較)한 상대치(相對値)는 다음과 같은 순위(順位)로 배열(配列)된다. $H_2O(5\;min.)\;1.0\;<\;H_2O(60min.)\;2.27\;<\;NH_4HCO_3\;5.57\;<\;NaHCO_3\;7.42\;<\;Double\;lactate\;9.71\;<\;Bray\;No.1\;12.53\;<\;Lancaster\;17.63\;<\;Nelson\;25.96\;<\;AcOH\;27.6\;<\;CAL-method\;50.27$ 토양적(土壤的) 특성(特性)의 차이(差異)로는 특이산성토(特異酸性土) 화산회토(火山灰土) 그리고 토성(土性)이 거친 토양(土壤)에서는 어느 방법(方法)으로도 측정(測定)된 인산량(燐酸量)은 매우 낮았다. 전반적(全般的)으로 토양(土壤)의 pH와 전인산(全燐酸)은 추출(抽出)되는 인산(燐酸)과 유의성(有意性)있는 정(正)의 상관(相關)을 보였으며 유기물량(有機物量)과는 Nelson법(法)$(HCl-H_2SO_4)$과 CAL법(法)에서 부(負)의 상관(相關)을 보였다. 교환성(交換性) Ca과는 특(特)히 Olsen법(法)$(NaHCO_3$추출(抽出))이 유의성(有意性)있는 상관(相關)을 보였으므로 석회질토양(石灰質土壤)에는 이 방법(方法)을 적용(適用)하는 것이 유용(有用)할듯하다. 2회(回) 연속재배(連續栽培)에 의하여 식물(植物)(옥수수)이 흡수(吸收)한 인산량(燐酸量)은 토양(土壤) 전인산량(全燐酸量)에 대비(對比)하면 매우 낮아 평균(平均) 4.05%에 불과(不過)하였으며 2차재배(次栽培)가 1차재배(次栽培)보다 평균(平均) 2배(倍) 이상의 높은 흡수(吸收)를 보였다. 각(各) 토양유효인산(土壤有效燐酸)의 측정방법(測定方法)에 의한 결과(結果)와 식물체(植物體)가 흡수(吸收)한 인산량(燐酸量)을 대조(對照)하여 한국전토양(韓國田土壤)의 유효인산량(有效燐酸量)을 화학적(化學的)으로 검토(檢討)하기 위하여 현재(現在) 널리 사용(使用)되고 있는 Lancaster법(法)보다는 Soltanpour$(NH_4HCO_3$추출(抽出))법(法), Double lactate법(法) 그리고 Bray No.1법(法)이 보다 적합(適合)할듯하나 이는 토양(土壤)의 성질(性質)과 작물(作物)의 종류(種類)를 달리한 조건(條件)에서 재검토(再檢討)하여 확정(確定)할수 있을듯하다.

  • PDF

한국, 중국, 일본 유아들의 일상생활에 대한 비교연구 (An analysis of daily lives of children in Korea, Japan and China)

  • 이기숙;정미라;김현정
    • 한국심리학회지 : 문화 및 사회문제
    • /
    • 제12권5호_spc
    • /
    • pp.81-98
    • /
    • 2006
  • 본 연구의 목적은 한국, 일본, 중국 유아들의 일상생활을 비교문화적으로 탐구하는 데에 있다. 이러한 연구목적을 달성하기 위해 본 연구는 한국, 일본, 중국의 3-6세 유아를 이머니 2,940명을 대상으로 유아의 하루일과 활동들을 설문지를 통해 조사하였다. 조사대상자들은 한국의 서울/경기에 거주하는 어머니 941명, 일본의 동경에 거주하는 어머니 1007명, 중국의 북경에 거주하는 어머니 992명이었다. 연구 결과 첫째, 하루일과 부분에 있어서 한국 유아들은 일본, 중국 유아들에 비해 기상시각 아침 및 저녁식사시각 취침시각이 모두 늦게 이루어지며, 수면시간 또한 일본, 중국외 유아들에 비해 짧은 편으로 나타났다. 둘째, 교육기관 부분에 있어서 중국, 일본, 한국 유아들 순으로 교육기관에 등원하였으며, 일본, 한국, 중국 순으로 귀가하는 것으로 나타났다. 평균 교육기관 재원시간은 중국이 가장 길었으며, 그 다음으로 일본의 보육시설, 한국의 보육시설, 한국과 일본의 유치원 순으로 나타났다. 또한 어머니들이 교육기관에 바라는 사항을 살펴본 결과 아이가 아플 때에도 교육기관에서 맡아주기를 가장 희망하였다. 셋째, 조사대상 유아들 중 한국은 72.6%가, 일본은 61.7%, 중국은 64.6%가 정규교육 이외의 조기 특기활동을 하고 있는 것으로 나타났으며, 그 활동유형으로 세 국가 모두 예체능 관련 활동과 영어를 많이 하고 있었는데, 한국은 학습지를 하는 비율이 일본, 중국에 비해 월등히 높게 나타났다. 넷째, 전자매체 사용에 있어서는 한국, 일본, 중국의 대다수 유아들이 거의 매일 텔레비전을 시청하고 있었으며, 게임은 일본 유아들이, 컴퓨터는 한국 유아들이 사용 비율이 높은 것으로 나타났다. 전자매체의 경우 상대적으로 중국 유아들이 한국, 일본 유아들에 비해 그 사용비율이 현저히 낮았다.

정상교합자와 I급 부정교합자에서 치아와 기저골의 관계에 대한 비교 분석 (COMPARATIVE ANALYSIS OF THE RELATIONSHIP BETWEEN BASAL BONE AND TEETH IN NORMAL OCCLUSION AND ANGLE'S CLASS I MALOCCLUSION)

  • 문혜정;경희문;권오원;김정민
    • 대한치과교정학회지
    • /
    • 제22권2호
    • /
    • pp.413-426
    • /
    • 1992
  • 저자는 좋은 교합관계를 유지하기 위한 치아와 기저골과의 관계를 분석하기 위해 정상교합자와 Angle써 I급 부정교합자(비발치군, 발치군)의 경석고 모형상에서 최대치아근원심폭경, 기저악궁폭경 및 기저악궁장경을 계측하고 최대치아근원심폭경 합, 최대치아근원심폭경 합에 대한 기저악궁폭경 비, 최대치아근원심폭경 합에 대한 기저악궁장경 비 및 최대치아근원심폭경 합에 대한 기저악궁폭경과 기저악궁장경합의 비를 산출하여 통계학적으로 분석한 결과 다음과 같은 결과를 얻었다. 1. 최대치아근원심폭경합에 대한 기저악궁폭경 비는 상악에서 정상교합군은 $46.9{\pm}2.6\%$, 비발치군은 $49.4{\pm}3.9\%$, 발치군은 $42.5{\pm}3.3\%$로 나타났으며, 하악에서 정상교합군은 $46.6{\pm}2.4\%$, 비발치군은 $47.5{\pm}4.0\%$, 발치군은 $42.6{\pm}2.6\%$로 나타났다. 2. 최대치아근원심폭경합에 대한 기저악궁장경 비는 상악에서 정상교합군은 $33.4{\pm}1.9\%$, 비발치군은 $33.9{\pm}1.8\%$, 발치군은 $28.7{\pm}2.5\%$로 타나났으며, 하악에사 정상교합군은 $34.4{\pm}4.3\%$, 비발치군은 $36.5{\pm}1.9\%$, 발치군은 $31.5{\pm}2.5\%$로 나타났다. 3. 최대치아근원심폭경합에 대한 기저악궁폭경과 기저악궁장경 합의 비는 상악에서 정상교합군은 $80.3{\pm}3.4\%$, 비발치군은 $83.3{\pm}4.8\%$, 발치군은 $71.2{\pm}4.3\%$로 나타났으며, 하악에서는 정상교합군은 $81.0{\pm}5.2\%$, 비발치군은 $84.0{\pm}5.4\%$, 발치군은 $74.1{\pm}4.1\%$로 나타났다. 4. 최대치아근원심폭경합에 대한 기저악궁폭경 비의 $95\%$ 신뢰구간은 상악에서 정상교합군은 $46.3-47.5\%$, 비발치군은 48.1-50.7, 발치군은 $41.7-43.3\%$로 나타났으며, 하악에서 정상교합군은 $46.1-47.2\%$, 비발치군은 $46.1-48.8\%$, 발치군은 $42.0-43.3\%$로 나타났다. 5. 최대치아근원심폭경합에 대한 기저악궁장경비의 $95\%$신뢰구간은 상악에서 정상교합군은 $32.9-33.8\%$, 비발치군은 $33.3-34.5\%$, 발치군은 $28.1-29.2\%$로 나타났으며, 하악에서 정상교합군은 $33.4-35.4\%$, 비발치군은 $35.8-37.2\%$, 발치군은 $30.9-32.1\%$로 나타났다. 6. 최대치아근원심폭경합에 대한 기저악궁폭경과 기저악궁장경 합의 비의 $95\%$신뢰구간은 상악에서 정상교합군은 $79.5-81.0\%$, 비발치군은 $81.6-84.9\%$, 발치군은 $70.1-72.2\%$로 나타났으며, 하악에서 정상교합군은 $79.8-82.2\%$, 비발치군은 $82.1-85.5\%$, 발치군은 $73.1-75.1\%$로 나타났다. 7. 최대치아근원심폭경합, 기저악궁폭경, 기저악궁장경, 최대치아근원심폭경 합에 대한 기저악궁폭경 비, 최대치아근원심폭경 합에 대한 기저악궁장경 비 및 최대치아근원심폭경 합에 대한 기저악궁폭경과 기저악궁장경 합의 비에서 발치군 남자의 기저악궁장경을 제외하고는 상하악간에 상관관계가 있는 것으로 나타났다.

  • PDF

쌀빵에 대한 인식 및 학교급식 적용 가능성 분석: 교육청 학교급식 담당자를 중심으로 (Perception of School Foodservice Officials on Rice Bread as School Foodservice Menu)

  • 양일선;이민아;차성미;조윤희;이소영;이소정;이해영
    • 한국식품영양과학회지
    • /
    • 제37권6호
    • /
    • pp.729-737
    • /
    • 2008
  • 본 연구에서는 교육청 학교급식 담당자를 대상으로 쌀빵을 학교급식에 적용하는데 있어서의 가능성 타진을 목적으로 학교급식 담당 실무자의 입장에서 쌀빵에 대한 인식 및 학교급식에의 적용가능성에 대해 분석 조사하였다. 응답한 33부의 설문지를 분석한 결과는 다음과 같다. 첫째, 조사대상자의 대부분(93.9%)은 여자였으며, 교육청 근무경력은 평균 2년 3.5개월, 학교급식관련 근무경력은 평균 8년 8.4개월이었다. 교육청 관할 하에 있는 학교로는 시 도 교육청 그룹에서는 초등학교의 경우 농어촌형 직영 272.3개교, 중학교의 경우 농어촌형 직영 115.5개교, 고등학교의 경우 농어촌형직영 73.0개교로 가장 많은 유형으로 나타났다. 지역교육청의 관할 하에 있는 학교 유형으로는 초등학교의 경우 도시형 직영 23.3개교, 중학교에서는 도시형 직영 11.6개교, 고등학교의 경우 도시형 위탁 5.3개교로 가장 높은 값으로 나타났다. 둘째, 교육청의 학교급식 지원 분야에 대해 복수응답하게 한 결과, 응답한 교육청 모두에서 저소득층 급식비를 지원하고 있었고 식품비 분야에서는 친환경농산물 12개청(50.5%), 우리농산물 5개청(20.8%), 지역농산물 4개청(16.7%)순으로 지원하고 있었다. 시 도 교육청에서는 저소득층 급식비(중앙값 839.0개교)에, 지역교육청에서는 지역농산물 식품비(중앙값 37.5개교)에 가장 많은 학교를 지원하고 있었다. 지원 금액으로는 시 도 교육청이 저소득층 급식비에 평균 168억원, 지역교육청이 급식종사자 인건비가 평균 10억 5천만원을 지원하고 있었다. 셋째, 학교급식에서의 쌀 이용현황을 살펴보면 초등학교에서는 평균 91.26%가 정부미, 40.64%가 지역쌀을 사용하고 있었고, 중학교와 고등학교 역시 정부미와 지역쌀을 주로 사용하고 있는 것으로 나타났다. 쌀 이용 증진에 대한 교육청의 관심도는 평균 5.00점(Likert 7점 척도)이었고 쌀 이용을 위한 교육청의 지원의지는 평균 4.66점으로 관심이 있다고 조사된 반면, 교육청이쌀 이용 증진을 위한 방안 및 정책을 시행한 경험은 평균 3.31점으로 나타나 상대적으로 정책 시행 경험이 적은 것을 알 수 있었다. 넷째, 학교급식에 쌀빵 메뉴 적용을 위한 방안 및 정책에 대해 교육청의 인식을 조사한 결과, 관심도는 평균 4.35점, 쌀빵 지원의지는 평균 4.14점, 급식에 쌀빵 적용의 바람직성은 4.71점, 급식에 쌀빵 적용 실현가능성은 4.69점으로 높은 점수를 나타낸 반면, 쌀빵 적용 방안 및 정책의 시행 경험은 2.18점으로 낮은 수준으로 조사되었다. 쌀빵을 학교급식에 적용하기 위한 바람직한 지원방법은 '관련 조리기기 지원'(예: 오븐) 19명(57.6%), '보조금 지급', '납품가 할인' 각 9명(27.3%), '현물(쌀빵)제공' 8명(24.2%)의 순으로 조사되었다. 쌀빵을 학교급식에 적용할 때의 장점으로는 다수가 '쌀 소비 촉진' 24명(72.7%)이라고 응답하였고, '영양적우수성' 18명(54.4%), '건강 지향적인 학교급식 이미지 제고' 17명(51.5%), '제공메뉴의 다양성' 12명(36.4%) 등의 의견이 있었다. 반면, 장애요인으로는 '조리시설(오븐 등)의 부족' 24명(72.7%), '비교적 높은 원가' 18명(54.5%), '식단 적용의 한계', '제한적인 조리방법'은 각 13명(39.4%), '급식정책의 미흡' 5명(15.2%), '업체의 홍보부족' 4명(12.1%) 등의 순으로 응답하였다. 다섯째, 교육청의 학교급식에서의 쌀 이용에 대한 의견과 쌀빵 적용에 대한 의견과의 상관성을 분석한 결과, 학교급식에서의 쌀 이용 증진에 대한 '관심'과 '지원의지'는 매우 유의한 상관관계가 있었으며(p<0.001), 또한 '관심'과 '지원의지'는 쌀 이용을 증진시키기 위한 방안 및 정책을 시행한 '경험'과 관련성이 있다고 조사되었다(각 p<0.05, p<0.01). 또 학교급식 메뉴에의 쌀빵을 적용하는 것에 있어서도 쌀빵 적용에 대한 '관심'과 '지원의지'는 유의한 상관관계가 있었으며(p<0.001), 쌀빵 적용의 '바람직성'과 '지원의지', 쌀빵 적용의 '실현가능성' 역시 매우 유의한 상관관계를 보여주었다(p<0.001). 쌀 이용에 대한 관심이 적은 그룹과 관심이 많은 그룹 간에는 학교급식 메뉴에 쌀빵을 적용하는 것에 대한 인식의 모든 항목에서 유의한 차이가 없다고 나타났으며, 쌀 이용 증진을 위한 지원의지가 높은 그룹과 낮은 그룹 간에는 쌀빵 적용을 위한 정책을 시행한 경험에 대한 문항을 제외하고는 유의한 차이를 보였다. 또한 쌀 이용 증진을 위한 정책을 시행한 경험 여부에 따른 두 그룹 간 학교급식 메뉴의 쌀빵 적용에 대한 인식을 비교한 결과, 쌀빵 적용에 대한 관심, 지원의지, 정책 시행 경험 문항에 있어서 경험 많은 군이 경험 적은 군에 비해 유의하게 높은 점수를 보여주었다(p<0.01). 이상의 연구 결과는 쌀빵을 학교급식에 적용 및 확대하는데 앞서 정책실행의 주체가 되는 교육청 담당자들의 인식을 파악한 것으로 앞으로의 쌀빵 적용 증진 계획을 효율적으로 세우는 것에 도움이 될 것이라고 판단된다. 연구결과와 같이 대부분의 교육청 급식 담당자들이 쌀 소비 촉진 및 영양과 건강증진 등의 이유로 쌀뿐만 아니라 쌀빵을 학교급식에 적용하는 것에 의지와 관심이 높음을 알 수 있었으나 실제로 실행에 옮기는 경우는 상대적으로 적은 것을 파악할 수 있었다. 따라서 앞으로 쌀빵을 학교급식에 확대 적용하기 위해서는 교육청 담당자들의 이런 의지와 관심을 더욱 확고히 하고 현실적인 지원, 예를들어 오븐 및 현물 지원 등의 적극적인 지원 방안이 수립되어야 한다고 사료된다. 본 연구는 조사대상자인 교육청 급식담당자의 표본수 확보에 한계를 보였고, 아직까지 상용화 및 급식현장에서 제공되는 비율이 미미한 쌀빵이 조사의 주제어였기에 응답자의 인지도 및 인식 부족이 연구의 한계점으로 작용하였다. 향후 급식현장에서의 목소리를 담아낼 수 있는 영양(교)사, 학생을 대상으로 하는 쌀빵관련 연구가 진행된다면 쌀빵 사용 확대에 현실적인 지원책 마련에 일조할 것으로 사료된다.

산지채석업체(山地採石業體)의 경영실태(經營實態) 및 적정규모설정(適正規模設定) -골재용(骨材用) 채석업체(採石業體)와 건축용(建築用) 채석업체(採石業體)의 비교(比較) 분석(分析)- (Analysis of Management Status and Optimum Production Scale of Quarrying Firms in Korea -Comparative Analysis of Aggregate and Building-Stone Quarrying Firms-)

  • 정하현;조응혁
    • 한국산림과학회지
    • /
    • 제80권1호
    • /
    • pp.72-81
    • /
    • 1991
  • 본(本) 연구(硏究)는 우리나라 채석업체(採石業體)의 경영개선(經營改善)을 위한 기초자료(基礎資料)를 제공(提供)할 목적(目的)으로 실시(實施)되었다. 이를 위하여 골재용(骨材用) 채석업체(採石業體) 30개소(個所)와 건축용(建築用) 채석업체(採石業體) 46개소(個所)의 경영실태(經營實態)와 경영성과(經營成果), 생산요소(生産要素) 투입(投入)의 경제성(經劑性), 적정규모(適正規模) 등을 분석(分析)하였으며, 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 골재용(骨材用) 채석업체(採石業體)와 건축용(建築用) 채석업체(採石業體)의 경영주(經營主) 연령(年齡) 40재(才) 이상(以上)이 각각(各各) 97%, 89.1% 이었고, 고졸이상(高卒以上) 학력(學歷) 소지자(所持者)가 각각(各各) 90%, 85% 이었다. 또한, 경력면(經歷面)에서 10년(年) 이하(以下)의 경영주(經營主)는 골재용(骨材用) 채석업체(採石業體)에서 70%, 건축용(建築用) 채석업체(採石業體)에서 52% 이었다. 따라서, 두 채석업체(採石業體)에 대한 경영주(經營主)의 대부분(大部分)은 고령(高齡), 고학력(高學歷) 소지자(所持者)이며, 경력면(經歷面)에서는 골재용(骨材用) 채석업체(採石業體)가 건축용(建築用) 채석업체(採石業體)보다 다소 낮게 나타났다. 2. 골재용(骨材用) 채석업체(採石業體)에 대한 경영조직(經營組織)의 형태(形態)는 회사법인(會社法人)이 60%로 많은 반면(反面), 건축용(建築用) 채석업체(採石業體)는 개인업체(個人業體)가 76%로 많게 나타났다. 골재용(骨材用) 채석업체(採石業體)의 허가면적(許可面積)은 약(約) 2.86ha, 건축용(建築用) 채석업체(採石業體)는 1.66ha으로 나타났다. 여기에서, 골재용(骨材用) 채석업체(採石業體)가 건축용(建築用) 채석업체(採石業體)보다 큰 규모(規模)로 경영(經營)되고 있음을 알 수 있다. 3. 골재용(骨材用) 채석업체(採石業體)의 연평균(年平均) 채석량(採石量)은 1985년(年)의 $88.961m^3$에서 1988년(年)의 $144.028m^3$로 증가(增加)하여 안정(安定)된 상태(狀態)에서 경영(經營)되고 있다. 반면(反面)에, 건축용(建築用) 채석업체(採石業體)의 경우는 1985년(年)에 $4.155m^3$이었던 것이 1987년(年)에는 $19.462m^3$으로 크게 증가(增加)하였으나, 1988년(年)에는 $13.400m^3$으로 감소(減少)하였다. 즉, 건축용(建築用) 채석업체(採石業體)는 다소 불안정(不安定)한 상태(狀態)에서 경영(經營)되고 있으므로 정부(政府)의 지속적(持續的)인 육성책(育成策)이 필요(必要)하다. 4. 골재용(骨材用) 채석업체(採石業體)에서 높은 비율(比率)을 차지하고 있는 비용항목(費用項目)은 장비화석료(裝備貨惜料), 감가상각비(減價償却費), 연간급여액(年間給與額), 수리유지비(修理維持費)등으로 나타났다. 건축용(建築用) 채석업체(採石業體)는 연간급여액(年間給與額), 감가상각비(減價償却費), 연료비(燃料費), 납부세액(納付稅額) 등의 순(順)으로 나타났다. 연간(年間) 이익율(利益率)은 골재용(骨材用) 채석업체(採石業體)가 9.7%, 건축용(建築用) 채석업체(採石業體)가 2.6%로서 골재용(骨材用) 채석업체(採石業體)가 보다 유리(有利)하게 경영(經營)됨을 알 수 있다. 5. 골재용(骨材用) 채석업체(採石業體)의 생산탄력성(生産彈力性)은 종업원(從業員)이 0.559, 유동비(流動費)가 0.513, 자본용역(資本用役)이 0.185로 나타났으며, 계수(係數)의 합계(合計)가 1.257>1로 나타났다. 건축용(建築用) 채석업체(採石業體)의 생산탄력성(生産彈力性)은 종업원(從業員)이 0.492, 유동비(流動費)가 0.192, 자본용역(資本用役)이 0.498로서 계수(係數)의 합계(合計)가 1.172>1로 나타났다. 따라서, 두 업체(業體) 모두 생산규모(生産規模) 확대(擴大)의 경제성(經劑性)이 존재(存在)한다. 6. 골재용(骨材用) 채석업체(採石業體)의 한계가치(限界價値) 생산액(生産額)에 대한 기회비용(機會費用)의 비율(比率)은 종업원(從業員)이 2.54, 유동비(流動費)가 3.62, 자본용역(資本用役)이 1.45로 나타났다. 건축용(建築用) 채석업체(採石業體)는 종업원(從業員)이 2.47, 유동비(流動費)가 2.34, 자본용역(資本用役)이 19.67으로 니타났다. 따라서, 생산증대(生産增大)를 위한 결정적(決定的) 요인(要因)은 골재용(骨材用) 채석업체(採石業體)의 경우에는 유동비(流動費)와 종업원(從業員)이고, 건축용(建築用) 채석업체(採石業體)의 경우에는 자본용역(資本用役)으로 나타났다. 7. 골재용(骨材用) 채석업체(採石業體)의 손익분기점(損益分岐點)에 의한 매출액(賣出額)은 약(約) 5.87억(億)원, 이윤극대화(利潤極大化)를 위한 최적매출규모(最適賣出規模)는 약(約) 20억(億)원으로 나타났다. 건축용(建築用) 채석업체(採石業體)의 손익분기점(損益分岐點) 매출액(賣出額)은 2.2억(億)원, 이윤극대화(利潤極大化)를 위한 매출규모(賣出規模)는 약(約) 5억(億)원으로 나타났다.

  • PDF

담수산새우 Macrobrachium rosenbergi (de Man)의 초기유생 및 Post-larva.의 성장에 미치는 염분량에 관하여 (ON THE EFFECTS CHLORINITIES UPON GROWTH OF EARLIER LARVAE AND POST-LARVA OF A FRESH WATER PRAWN, MACROBRACHIUM ROSENBERGI(DE MAN))

  • 권진수;우야관;소립원의광
    • 한국수산과학회지
    • /
    • 제10권2호
    • /
    • pp.97-114
    • /
    • 1977
  • 1. Macrobrachium rosenbergi(de Man)의 효율적인 종묘생산의 방안을 모색하기 위한 연구의 일환으로 염분량이 유생에 미치는 영향을 조사하기 위하여 부화직후의 Zoea유생을 (1) 염분량 별로 9실험구:담수, $3.48\~4.42\%_{\circ}Cl,\;5.26\~6.45\%_{\circ}Cl,\;7.63\~8.23\%_{\circ}Cl,\;9.76\~10.52\%_{\circ}Cl,\;11.27\~11.94\%_{\circ}C1,\;13.12\~14.08\%_{\circ}Cl,\;16.13\~16.88\%_{\circ}Cl$$18.04\~18.92\%_{\circ}Cl$로 구분한 사육수에서 수온 $28^{\circ}C{\pm}1$ 및 여과유속 0.6l/min.로 고정한 순환식 수조(용량 25l)내에서 Artemia salina nauplii 투이하며 post-larva령기까지 변태되는 온도별 성장 속도와 그 변태율을 비교하여 본 유생의 생육여과도를 조사하였고, (2) 각 령기별유생의 각종 염분량에 대한 적응도와 선택기호성을 조사하기 위하여 1l 용량의 코니칼 비커속에 수온 $28^{\circ}C{\pm}1$, aeration (3-4기포/sec)을 약하게 유지한 12실험구 ; 담수, $2.21\~2.76\%_{\circ}Cl,\;4.12\~4.47\%_{\circ}Cl,\;5.58\~5.98\%_{\circ}Cl,\;8.23\~8.64\%_{\circ}Cl,\;10.11\~10.56\%_{\circ}Cl,\;11.85\~12.42\%_{\circ}Cl,\;13.05\~14.51\%_{\circ},\;14.75\~15.38\%_{\circ}Cl,\;16.86\~17.72\%_{\circ}Cl\;18.54\~19.08\%_{\circ}Cl$ 및 해수$(19.38\%_{\circ}Cl)$로 구분한 사육수에 제 1 Zoea 령기, 제 4 Zoea 령기, 제 6 Zoea 령기, 제 8 Zoea 령기, 제 10 Zoea령기 및 제 11 Zoea령기를 급격한 염도변화에 조우당함을 피하기 위하여 일정한 염도에 순화시킨 후 각각 이주시켜 Artemia salina nauplii를 투이하고 2일간격으로 실험구의 사육수를 치환하며 6일간을 사육한 후 각실험구별의 생잔유생수를 서로 비교하였다. (3) 수온 $28^{\circ}C{\pm}1$를 유지시키고 염도가 상이한 3종의 사육조 ; $3.82\~4.68\%_{\circ}Cl,\;7.14\~7.85\%_{\circ}Cl$$10.22\~11.05\%_{\circ}Cl$에서 사육, 성장시킨 제 2 Zoea, 제 4 Zoea, 제 6 Zoea 및 제 8 Zoea 령기의 유생을 별도로 염분별로 3실험구 : $3.68\~4.34\%_{\circ}Cl,\;7.42\~8.28\%_{\circ}Cl$$10.71\~11.53\%_{\circ}Cl$로 구분한 150 l 용량의 여과실험조에 서로 염도가 상이한 간격간을 이주 (Fig. 4)시켜 12일간을 Artemia salina nauplii를 투이하고 수온 $28^{\circ}C{\pm}1$을 유지시키며 사육한 후 이주시킨 유생의 령기별 및 사육도중에 이주한 염도의 간격차에 대한 생잔율을 서로 비교하여 사육도중에 조우하는 변동된 염도에 대한 각 령기별 유생의 적응도를 조사하였으며 이 실험을 위하여 수온 $28^{\circ}C{\pm}1$, 염분량 $5.28\%_{\circ}Cl$에서 갓 부화된 유생을 각사육조에 분양시켜 사육하였다. (4) post-larvarl 및 Juvenile의 염분량에 대한 성장률 및 서식적염도를 조사하기 위하여 수온 $28^{\circ}C{\pm}1$, 여과유속 $0.6\~0.8l\~min$를 유지시키며 염분별로 6실험구 ; 담수 $3.61\~4.25\%_{\circ}Cl$$16.87\~17.13\%_{\circ}Cl$로 구분하여 각실험별로 40일, 60일 및 120일의 성장도 및 그 생잔율을 상호 비교하였다. qs 실험기간중 투여한 이료는 반숙절편한 반지락을 사용하였다. 2. 본유생의 post-larva로 변태하기 위해서는 반드시 일정량의 염분량이 요하고 기호, 선택하는 염분량은 각령기에 따라 다소상이하나 대체로 염분량 $7.63\%_{\circ}Cl$에서 $14.42\%_{\circ}Cl$의 범위가 적염도로 생각되며 이 범위내에서는 염분량에 따른 변태속도의 차이는 거의 볼 수 없으나 염분량 $4.42\%_{\circ}Cl$이상의 보다 높은 염도에서는 현저한 지연현상이 나타나며 더욱이 높은 염도에 비하여 저염도인 경우가 더욱 늦어지는 경향을 보인다. 3. 각 Zeoa 령기별의 염분량에 대한 적응도는 대체로 염분량 $8.28\~12.42\%_{\circ}Cl$ 사이가 가장 크나 령기가 기호, 선택하는 염분량에 차이가 있으므로 그 적응도도 서로 상이하다. 보편적으로 전령기를 통하여 제8 Zoea기를 전환점으로 하여 이 보다 어린 령기의 유생일수록 비교적 높은 염도에 대한 적응도가 높은데 반하여 령기가 진전되어 post-larva 기로 근접해 갈수록 점차적으로 저염도에 대한 기호, 선택성이 커지는 경향을 보인다. 4. Post-larva기에 대한 서식적염도는 염분량 $8.08\%_{\circ}Cl$ 담수의 범위로서 Zoea 령기에 비하여 저염성을 나타내고 더우기 적정범위는 염분량 $4.25\%_{\circ}Cl$로서 담수에 가까울수록 그 성장도는 높다. 따라서 Zoea유생은 담수에서 보다 성장률이 높다. 한편 post-larva는 령기 의 개체가 해수($19.38\%_{\circ}Cl$ 이상)에서 1일이상을 생존치 못하는데 비하여 Zoea 유생은 6일이사을 적응할 수가 있다. 5. Zoea 유생은 염분량에 대한 특성이 령기의 진전에 따라 고염성으로부터 저염성으로 그 특성이 조금씩 이행됨은 제8 Zoea 령기를 지나므로써 post-larva 기가 가지고 제 특성으로 점차 이행되기 때문으로 생각되며 이같은 현상을 뒷받침하는 것은 형태적으로 제 8 령기를 전후하여 종전의 유생에 제1, 제2 보각에 협지가 형성됨과 동시에 유영피도 거의 완성되어 post-larve 기의 형태로 이행됨을 볼 수 있고 또한 생태적으로도 제10-제11령기에 이르러서는 종전의 유영층에서 점차로 저변으로 이행하여 유영동작도 훨씰 둔화되어 post-larvarl로 전환되는 과도기의 특성을 관찰할 수가 있다. 따라서 이같은 점을 결부하여 제 8 령기를 지남으로써 염분량에 대한 특성 및 적응도가 종전의 유생기와 상이해 짐을 이해할 수 있다. 6. 령기별 Zoea유생을 사육도중에 염분량 $3.68\~11.53\%_{\circ}Cl$ 범위내에서 고, 저염도간을 갑자기 이주시켜 조우한 염도변화에 대한 적응도를 조사하니 제 8 Zoea 령기를 전환점으로 하여 어린 령기일수록 저염도에서 높은 염도로 이주했을 때의 적응도가 크고, 령기가 진전되어 post-larva 기에 가까워 질수록 반대로 높은 온도에서 저염도로 이주했을 때의 적응도가 점차로 커져가는 경향을 보였다. 또한 특의한 현상은 상이한 두 염도간을 가역방향으로 이주시켰을 때의 적응도는 각각 상이하고 이같은 경우에도 제 8 Zoea 령기를 경계로 하여 이동된 염분량에 대한 령기별 유생의 적응도도 전환되는 현상을 나타내었다. 7. Zoea 유생을 사육하는 동안 사육수의 염분함유량에 비례하여 유생의 체표에 산재하는 색소포가 팽창되어 주로 붉은색을 나타내게 됨으로 염분함유량과 색소포의 확장과는 어떤 관계가 있는 듯 생각된다. 8. 령기별 Zoea 유생 및 post-larva 기의 염분량에 대한 기호, 선택성과 치하 및 성하의 서식분포역을 고려할 때 자연서식역의 하천에서는 왕부하는 생활사를 취하는 듯 생각된다. 9. 본종의 종묘생산을 효율적으로 영위하기 위해는 유생의 염분량에 대한 특성을 고려하여 제 8 Zoea 령기를 경계로 해서 어린 유생기에서는 대략 염분량 $8\%_{\circ}Cl$에서 $12\%_{\circ}Cl$를 유지시켜 사육하다가 제 8령기 이후 부터는 점차로 담수를 첨가시켜 염분량이 령기의 진전에 따라 $7\%_{\circ}Cl$에서 $4\%_{\circ}Cl$로 이행되게 하는 것이 능률적이며 또한 효과적인 사육법의 하나로써 Green water를 사용할 때도 사육환경의 변동에 민감한 어린 유생기에 단세포 녹조류를 충분히 번식시켜 사육수내이 생물학적 평형상태를 유지시켜 주는 것이 중요함으로 어린 령기에는 가능한 염도를 높여 Green water의 보존도 효과적으로 하는 것이 전망된다.

  • PDF