• 제목/요약/키워드: 95% 신뢰구간

Search Result 356, Processing Time 0.028 seconds

Folate retention in Namul according to various heating methods (다양한 열 처리방법에 대한 나물류의 엽산 잔존율)

  • Jung, Jae Eun;Jeong, Hea-Jeong;Hyun, Taisun;Park, Su-Jin;Chun, Jiyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.425-431
    • /
    • 2019
  • Selected leafy vegetables, widely used for Korean Namul dishes, were heat-treated in different ways and their folate retention was investigated. The Lactobacillus casei method was applied for folate estimation and validated to ensure reliability of analytical data. The folate content in Namul highly varied, from 29.7 to $293.4{\mu}g/100g$, depending on the heating methods and the types of vegetables. Most of the Namul variants showed increased folate content on heat treatment. Frying yielded higher folate retention than the other cooking methods (blanching, steaming, baking, and panfrying), and pig weed showed the highest folate retention (3.3 times, $293.4{\mu}g/100g$). L. casei assay for folate estimation showed 95.7% recovery and relative standard deviations less than 2% for both reproducibility and repeatability, indicating good accuracy and precision. Quality of the folate assay was assured by monitoring a quality control chart and a proficiency test (z-score= -0.1) during the entire of study.

Comparison of Water Quality Before and After Four Major River Project for Water Monitoring Stations Located Near 8 Weirs in Nakdong River (낙동강 8개 보 인근 수질측정 지점의 4대강 사업 전·후 수질 변동성 분석)

  • Cho, Hyun Kyung;Lim, Hyo Jin;Kim, Sang Min
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.89-101
    • /
    • 2018
  • The purpose of this study was to evaluate the variation of water quality in the Nakdong River by the Four major river projects. For this purpose, the nearest upstream water quality monitoring stations were selected and water quality data such as BOD, COD, SS, TN, TP, and TOC were collected for the before Four major river project(from January 2003 to November 2008), during the project(from September 2008 to April 2012) and after the project(from May 2012 to September 2017). As a result, the concentration of DO, BOD, COD, TN, and TOC after the project tend to be higher than the before project period. On the other hand, the SS and T-P values decreased after the project. Spatial analysis of BOD, COD, and TOC, which have large changes in water quality factor, by water quality grade, showed a tendency that water quality grade after the project was worse than before the project.

A convergent meta-analysis of the effect of hospice nursing intervention (호스피스 간호중재 프로그램 효과에 관한 융·복합 메타분석)

  • Kim, Woon Soon
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.419-432
    • /
    • 2018
  • The purpose of this study is to develop a hospice intervention program and present basic study data using a method of Meta analysis. Fifteen theses from 2002 to 2017 were collected from the on-line database at Korean Education and Research Information Service and other journals related hospice. Main keywords were 'hospice' and intervention'. The selected 15 theses were analyzed with publication bias, outcome of effect size, non-overlap percentage(U3), 95% confidence intervals and homogeneity. The result of the study is summarized as follows; Publication bias was stable and the effect size of hospice program was significant at. 99. The effective and significant regulation effects were publication years with 2003 to 2007(ES=1.24), publication types with journals(ES=1.33), majors with nursing sciences(ES=1.02), ages with 29 to 30(ES=1.09), later session(ES=1.06) and aroma(ES=1.12). Accordingly, this thesis has its meaning in that it used a Meta-analysis to analyze domestic theses of hospice intervention programs for the first time in Korea. This thesis will prodide specific guidance to researchers trying to develop and utilize hospice intervention programs resulting in helpful usages in professional hospice institutions with implementations of programs.

Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography (흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • This study is to confirm the range of tube voltage for Chest X-ray in DR system by comparing with dose area product (DAP) and effective dose in efficient detector exposure index (DEI) range. GE definium 8000 was used to for the phantom study. The range of tube voltage is 60~130 kVp and of mAs is 2.5~40 mAs. The acquired images were classified into efficient DEI groups, then calculated effective dose with DAP by using a PC-Based Monte Carlo Program 2.0. The signal to noise ratio (SNR) was measured at 4 regions, including the thoracic spine, the lung area with the ribs, the lung area without the ribs, and the liver by using Picture Archiving and Communication System. The significance of the group for each tube voltage was verified by performing the kruskal-wallis test and the mann-whitney test as a post-test. When set to 4 groups dependned on the tube voltage, DAP showed significant differences; 60 kVp and 80 kVp, and 60 kVp and 90 kVp (p= 0.034, 0.021). Effective dose exhibited no statistically significant differences from the all of the group (p>0.05). SNR exhibited statistically significant differences from the all of the group in the liver except compared to 80 kVp and 90 kVp (p<0.05). Therefore, high tube voltages of 100 kVp or more need to be reconsidered in terms of patient dose and imaging in order to represent an appropriate chest X-ray image in a digital system.

Automated Satellite Image Co-Registration using Pre-Qualified Area Matching and Studentized Outlier Detection (사전검수영역기반정합법과 't-분포 과대오차검출법'을 이용한 위성영상의 '자동 영상좌표 상호등록')

  • Kim, Jong Hong;Heo, Joon;Sohn, Hong Gyoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4D
    • /
    • pp.687-693
    • /
    • 2006
  • Image co-registration is the process of overlaying two images of the same scene, one of which represents a reference image, while the other is geometrically transformed to the one. In order to improve efficiency and effectiveness of the co-registration approach, the author proposed a pre-qualified area matching algorithm which is composed of feature extraction with canny operator and area matching algorithm with cross correlation coefficient. For refining matching points, outlier detection using studentized residual was used and iteratively removes outliers at the level of three standard deviation. Throughout the pre-qualification and the refining processes, the computation time was significantly improved and the registration accuracy is enhanced. A prototype of the proposed algorithm was implemented and the performance test of 3 Landsat images of Korea. showed: (1) average RMSE error of the approach was 0.435 pixel; (2) the average number of matching points was over 25,573; (3) the average processing time was 4.2 min per image with a regular workstation equipped with a 3 GHz Intel Pentium 4 CPU and 1 Gbytes Ram. The proposed approach achieved robustness, full automation, and time efficiency.

Research on the use of Therapeutic Linear accelerator Quality Control using EPR/alanine Dosimeter (EPR/알라닌 선량계를 이용한 치료용 선형가속기 정도관리 활용 연구)

  • Yoon-Ha Kim;Hyo-Jin Kim;Yeong-Rok Kang;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.239-248
    • /
    • 2024
  • Radiation therapy uses high energy, which can have side effects on the human body. Therefore, it is important to ensure that the appropriate dose is set for irradiation and to have confidence in the radiation produced by the generator. The EPR/Alanine dosimetry system is characterized by water equivalence, dose response linearity, and low fading, which makes it useful for quality control of radiation therapy equipment. In this study, we compared the signal and dose response curves of EPR/Alanine dosimetry by mass of alanine using 6 MV energy of a LINAC. An alanine dosimeter and EPR spectrometer from Burker, and a LINAC from Elekta, were used. A dose response curve and a 1st order regression equation were constructed from the irradiated dose and the EPR signal from the alanine dosimeter. We compared the signal magnitude and dose response curve with mass and checked the confidence through the measurement uncertainty of the dose response curve. As a result, it was found that the magnitude of the EPR signal increased by about 1.3 times at 64.5 mg, and the sensitivity of the dose response curve increased as the mass increased. The measurement uncertainty was evaluated to be between 5.84 % and 8.93 %. Through this study, it is expected that the EPR/alanine dosimetry system can be applied to the quality assurance and quality control of a LINAC.

Estimating the Size Effect on Relative Species Number in Macrobenthic Community (대형 저서동물 군집의 채집 면적이 상대적 출현 종수에 갖는 효과의 추정)

  • 유재원;김창수;박미라;이형곤;이창근;이재학;홍재상
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.1
    • /
    • pp.20-29
    • /
    • 2004
  • Macrobenthos species-area relationship was investigated and empirical models were estimated to enable comparisons among species numbers of different sample size. The study aims to choose a way to predict cumulative relative species number (CRSN) in a given sample size Saemangeum, located in the west coast of South Korea, were visited in Apr., May and Aug.,2002 and a total of 261 biological samples from 87 stations were obtained by employing a quantitative sediment sampler, Smith-McIntyre grab and design of 3 replicates at each station. Relative species numbers (%) were baselined at sample size of 1000 $\textrm{cm}^2$ and the patterns of CRSN along the axis of sample size were measured and observed. In correlation analysis performed on a set of abiotic and biotic variables, log-transformed CRSN showed the only significant relationship with log-transformed density. Based on the result, three models, Log CRSN 2000, Log CRSN 3000 and Log CRSN were produced. The former two were devised to predict CRSN at 2000 and 3000 $\textrm{cm}^2$ respectively, and the latter at various sample sizes and samplers (all p-values were <0.001). Database from other studies (intertidal or subtidal macrofaunal samples from Kyonggi Bay and Saemangeum) were used to evaluate validity of the models. Observed CRSN below sample size of 3000 $\textrm{cm}^2$ fell under the range of 95% prediction interval and this was appeared to provide reliability of the models below that sample size.

An indicator for managing the regional variations in approval rates of long-term care (LTC) service (지역별 장기요양 인정의 차이 관리지표 개발)

  • Han, Eun-Jeong;Lee, JungSuk;Park, Seyoung;Jang, Soomok;Jung, Inkyung
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.3
    • /
    • pp.391-401
    • /
    • 2017
  • This study develops an indicator to manage regional variations of approval rates for long-term care (LTC) service. We used LTC insurance data for grade assessment that include 433,155 applicants from 227 LTC centers across Korea in 2015. The approval rate for each center was defined as the proportion of the numbers of approved applicants out of all applicants. We assumed that the approval rates depended on the characteristics of applicants. We estimated the 'standard' approval rates from a multiple linear regression analysis using the characteristics of applicants as independent variables. The difference between the observed and the standard rates was then defined as an indicator for deviation. A center having a large difference could be considered as a center with a potential error in grade assessment. We also examined if the characteristics of investigators affected the approval rates. We found that the socio-demographic characteristics of applicants and reapplication rate for LTC grade were independent factors affecting the approval rates. Centers having the management indicator values falling outside the middle 95% of the distribution were identified as centers with an error in grading. We expect that this study will contribute to enhancing reliability and equity in LTC grading.

Bicycle Riding-State Recognition Using 3-Axis Accelerometer (3축 가속도센서를 이용한 자전거의 주행 상황 인식 기술 개발)

  • Choi, Jung-Hwan;Yang, Yoon-Seok;Ru, Mun-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.63-70
    • /
    • 2011
  • A bicycle is different from vehicles in the structure that a rider is fully exposed to the surrounding environment. Therefore, it needs to make use of prior information about local weather, air quality, trail road condition. Moreover, since it depends on human power for moving, it should acquire route property such as hill slope, winding, and road surface to improve its efficiency in everyday use. Recent mobile applications which are to be used during bicycle riding let us aware of the necessity of development of intelligent bicycles. This study aims to develop a riding state (up-hill, down-hill, accelerating, braking) recognition algorithm using a low-power wrist watch type embedded system which has 3-axis accelerometer and wireless communication capability. The developed algorithm was applied to 19 experimental riding data and showed more than 95% of correct recognition over 83.3% of the total dataset. The altitude and temperature sensor also in the embedded system mounted on the bicycle is being used to improve the accuracy of the algorithm. The developed riding state recognition algorithm is expected to be a platform technology for intelligent bicycle interface system.

Analysis of Noise Characteristics of Double and Single-layered Porous Pavement with CPX Method -National Route 1, Sejong-Si Section- (CPX방법에 의한 복층 및 단층 다공성포장의 소음특성 분석 -국도 1호선 세종시 구간-)

  • Yoo, In-Kyoon;Lee, Su-Hyung;Han, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.55-63
    • /
    • 2020
  • Road traffic noise is a major complaint. Porous pavement (PP) has been proposed as an effective method for reducing road traffic noise, but it has not been applied much due to the lack of quantitative evaluation. In this study, the noise reduction of single-layer porous pavement (SLPP) and double-layer porous pavement (DLPP) was evaluated. The noise was measured using the CPX method, and the driving speed was measured every 10km/h from 50km/h to 80km/h. The differences in noise level between the two PPs were statistically significant. The driving speed had no significant effect on the difference in noise between the two PPs. The DLPP showed a 6.6dB(A) reduction in average and a 6.3dB(A) reduction at the 95% confidence level compared to the SLPP. Reducing noise by 5dB(A) is equivalent to reducing traffic to 1/3 or lowering the vehicle's speed to 1/2. Sensitively, it is possible to recognize a 3dB(A) and 5dB(A) difference. The DLPP and SLPP were very effective in reducing traffic noise.