• Title/Summary/Keyword: 90B22

Search Result 468, Processing Time 0.024 seconds

UNSLOTTED CSMA/CD PROTOCOL WITH THE THRESHOLD CONTROL POLICY

  • KYUNG HYUNE RHEE
    • Journal of applied mathematics & informatics
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 1994
  • We consider a single channel CSMA/CD system with D homogeneous stations and impeded buffer of infinite size. We find a sufficient condition for the model to be stable under the threshold control policy and derive the limiting distri-bution of the number of messages in the system at the moment of service completion. We also derive the limiting distributing of the number of messages in the system size at arbitrary time by using Markov regenerative processes. Some numerical examples and special cases are also treated.

Experimental Study on Mixing Efficiency of Exhaust Gas and Reductant According to SCR Mixer Shape (SCR 믹서형상에 따른 배기가스와 환원제 혼합 효율에 관한 실험적 연구)

  • Choe, Munseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.74-79
    • /
    • 2021
  • This study examined the mixing efficiency of exhaust gas and urea according to the mixer shape in the SCR system. For the experiment, an SCR simulation system was manufactured, and a uniformity detector was attached to the catalyst location to measure the uniformity. The experiment was conducted by setting the exhaust-gas flow rate, temperature, mixer type, and catalyst distance as variables. The experimental results confirmed the swirl angle analysis, urea number distribution, and uniformity. The swirl angle experiment of Models A and B confirmed that the swirl angle of Model A was formed approximately 7 to 8 degrees higher over the entire RPM range. When there was no mixer in the SCR system, the urea and water were concentrated to one side. Mixer Model A showed an even distribution overall, and Model B showed a slightly concentrated tendency at the beginning but then showed a stable distribution of urea. The mixing efficiency of 90%, which was the uniformity target, could be satisfied in Model A and Model B. In particular, Model A showed excellent results that satisfied 90% efficiency at 10 cm of the catalyst position.

Wideband 6-port Phase Correlator Using Caxial Cable Impedance Transformer and Wireline Coupler (동축선 임피던스 변환기와 Wireline Coupler를 이용한 광대역 6-단자 위상 상관기)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.8
    • /
    • pp.1188-1195
    • /
    • 2022
  • The 6-port phase correlator consists of one in-phase power divider and three 3-dB 90-degree phase difference power dividers, and is mainly used in a demodulation circuit that determines the phase of an input signal. This paper proposes the wideband 6-port phase correlator that consists of an in-phase power divider using a wideband 2:1 impedance transformer with three 37.5-Ω coaxial cables, and a 3-dB 90-degree phase difference power divide using Wireline. The proposed wideband phase correlator fabricated at a center frequency of 1000MHz has the value of the input reflection coefficient(S11 and S22) -14dB or less in the frequency range of 640~1270MHz. Also, the signal transmission characteristic(Si1), from the in-phase power divider input port to four output ports, has the amplitude of -6.5±0.6dB and the phase error of within ±3.4°, and the signal transmission characteristic(Si2), from the 90 degree phase difference power divider input port to four output ports, has the amplitude of -6.1±0.6dB and the phase error of within ±6.2°.

SIW-Based 2×4 Array Antenna with a Sequential Feeding for X-Band Satellite Communication (순차적 급전을 이용한 위성 통신용 SIW 2×4 배열 안테나)

  • Jung, Eun-Young;Lee, Jae-Wook;Lee, Taek-Kyung;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.125-130
    • /
    • 2011
  • In this paper, SIW-based $2{\times}4$ uniform array antenna with a sequentially fed 8-way power divider with an equal division characteristic is proposed for an application of X-band satellite communication. In particular, sequential feeding structures with a progressive phase difference of 90 degrees between the nearest elements have been suggested to protect the cancellation of electric fields due to the array alignments and to enhance the purity of RHCP(Right-Handed Circular Polarization). The obtained results according to the return loss bandwidth, RHCP antenna gain, axial ratio bandwidth are 760 MHz ranging from 7.90 to 8.66 GHz under the criterion of less than -10 dB, 14.3 dBic at 8.3 GHz, and 600 MHz from 8.15 to 8.75 GHz, respectively. In addition, it is observed that the equal-division characteristic of SIW-based 8-way power divider is approximately -9.2 dB in all ports.

A 1.2V 90dB CIFB Sigma-Delta Analog Modulator for Low-power Sensor Interface (저전력 센서 인터페이스를 위한 1.2V 90dB CIFB 시그마-델타 아날로그 모듈레이터)

  • Park, Jin-Woo;Jang, Young-Chan
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.786-792
    • /
    • 2018
  • A third-order sigma-delta modulator with the architecture of cascade of integrator feedback (CIFB) is proposed for an analog-digital converter used in low-power sensor interfaces. It consists of three switched-capacitor integrators using a gain-enhanced current-mirror-based amplifier, a single-bit comparator, and a non-overlapped clock generator. The proposed sigma-delta analog modulator with over-sampling ratio of 160 and maximum SNR of 90.45 dB is implemented using $0.11-{\mu}m$ CMOS process with 1.2-V supply voltage. The area and power consumption of the sigma-delta analog modulator are $0.145mm^2$ and $341{\mu}W$, respectively.

Importance of convection during physical vapor transport of Hg2Cl2 in the presence of Kr under environments of high gravitational accelerations

  • Kim, Geug-Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Special attention in the role of convection in vapor crystal growth has been paid since some single crystals under high gravity acceleration of $10g_0$ appear considerably larger than those under normal gravity acceleration ($1g_0$). With increasing the gravity acceleration from $1g_0$ up to $10g_0$, the total molar flux for ${\Delta}T$ = 30 K increases by a factor of 4, while for ${\Delta}T$ = 90, by a factor of 3. The maximum molar fluxes for three different gravity levels of $1g_0$, $4g_0$ and $10g_0$, appear approximately in the neighborhood of y = 0.5 cm, and the molar fluxes show asymmetrical patterns, which indicate the occurrence of either one single or more than one convective cell. As the gravitational level is enhanced form $1g_0$ up to $10g_0$, the intensity of convection is increased significantly through the maximum molar fluxes for ${\Delta}T$ = 30 K and 90 K. At $10g_0$, the maximum total molar flux is nearly invariant for for ${\Delta}T$ = 30 K and 90 K. The total molar flux increases with increasing the gravity acceleration, for $1g_0{\leq}g_y{\leq}10g_0$, and decreases with increasing the partial pressure of component B, a noble gas called as Kr (Krypton), $P_B$. The ${{\mid}U{\mid}}_{max}$ is directly proportional to the gravity acceleration for 20 Torr $P_B{\leq}300$ Torr. As the partial pressure of $P_B$ (Torr) decreases from 300 Torr to 20 Torr, the slopes of the ${{\mid}U{\mid}}_{max}s$ versus the gravity accelerations increase from 0.29 sec to 0.54 sec, i.e. by a factor of 2. The total molar flux of $Hg_2Cl_2$ is first order exponentially decayed with increasing the partial pressure of component B, $P_B$ (Torr) from 20 Torr up to 300 Torr.

Prevalence and Toxin Characteristics of Microorganism on Hand Towels Using for Children in Child Care Center (보육시설 유아 사용 수건의 미생물 분포 및 독소 특성)

  • Kim, Jung-Beom;Kim, Nan-Yong;Kang, Suk-Ho;Do, Young-Sook;Eom, Mi-Na;Yoon, Mi-Hye;Lee, Jong-Bok
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • This study was conducted to evaluate the microbiological contamination on commonly used hand towels in the child care centers and to investigate the toxin gene and toxin production ability of food-borne pathogens. A total of 22 commonly used hand towels including 7 for before use and 15 for during use were tested. The average number of total aerobic bacteria and fungi were 6.2 log CFU/100 $cm^2$ and 4.1 log CFU/100 $cm^2$. Coliform bacteria were detected in 4 out of 7 before used towels (57.1%) and all of during used towels (100%). These results showed that the sanitary conditions of hand towels in the child care centers should be improved promptly. Among the pathogenic bacteria, Staph. aureus and B. cereus without Salmonella spp. were detected in 5 (22.7%) and 11 (50.0%) out of 22 hand towels. All of Staphy. aureus isolated in this study did not possess any toxin genes and did not produce enterotoxin. The detection rate of hblC, hblD, and hblA toxin genes in B. cereus was 72.7, 72.7, and 54.5% respectively. The possession rate of nheA, nheB, and nheC toxin genes showed 81.8, 72.7, and 54.5% respectively. The cytK and entFM toxin genes were presented at 45.5 and 90.0% in B. cereus. The HBL was detected in 8 out of 11 B. cereus isolates (72.7%) and 5 B. cereus isolates produced NHE (45.5%). Ten out of eleven B. cereus isolates (90.9%) produced one or more enterotoxin such as HBL and NHE. From the results, using a private hand towel or paper towel is required to prevent the cross-contamination between commonly used hand towel and children's hands in the child care center.

A Performance Consideration on Conversion Loss in the Integrated Single Balanced Diode Mixer

  • Han, Sok-Kyun;Kim, Kab-Ki
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.3
    • /
    • pp.139-142
    • /
    • 2003
  • In this paper, we consider the factors that affect a conversion loss performance in designing a single balanced diode mixer integrated with IRF(Image Reject Filter), based on the embedded electrical wavelength placed between the IRF and mixer, diode matching and LO drive amplifier. To evaluate the conversion loss performance, we suggest two types of a single balanced mixer using 90 degree branch line coupler, microstrip line and schottky diode. One is only mixer and the other is integrated with IRF and LO drive amplifier. The measured results of a single balance diode mixer integrated IRF show the conversion loss of 8.5 dB and the flatness of 1 dB p-p from 21.2 GHz to 22.6 GHz with 10 dBm LO. The measured input PI dB and IIP3 are 7 dBm and 15 dBm respectively under the nominal LO power level of 10dBm. The LO/RF and LO/IF isolation are 22 dB and 50 dB, respectively.

Biological Control of Blue Mold by Microorganism (잿빛 곰팡이병의 미생물학적 제어)

  • 조정일;조자용;안병렬
    • Korean Journal of Organic Agriculture
    • /
    • v.8 no.3
    • /
    • pp.121-130
    • /
    • 2000
  • In order to screen the antagonistic bacteria which inhibit the growth of the plant pathogen, Penicillum expansum, we isolated an effective bacterial strain and investigated into the antifungal activity of the antagonist and it's identification. The eleven strains of bacteria which strongly inhibited P. expansum were isolated from the nature, and the best antagonistic bacterial strain designated as KB22, was selected. The antagonistic strain KB22 was identified to be the genus Bacillus subtilis based on morphological and biochemical characterization, The KB22 showed 55.9% of antifungal activity against the growth of P. erpansum. By the treatment of the culture broth and the heat treated culture filtrate of it, the B. subtilis KB22 showed 90% and 15% of antifungal activity, respectively.

  • PDF

Effects of Noise and Vibration on Oxygen Consumption and Ammonia Excretion in Cultured Catfish (Silurus asotus) (양식장에서 사육하는 메기 (Silurus asotus)의 산소소비 및 암모니아 배설에 미치는 소음진동 영향)

  • Hur, Jun Wook;Lee, Jeong Yeol;Joo, Jin Chul
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.2
    • /
    • pp.105-109
    • /
    • 2018
  • The main objective of this investigation was to examine oxygen consumption and ammonia excretion within cultured catfish, Silurus asotus ($22.9{\pm}0.9cm$, $100.7{\pm}11.7g$ n = 30) by noise and vibration stress in aquaculture farm. The vibration of 48, 58 and 68 dB (V) and noise of $77.6{\pm}1.8dB$ (A) from an electric vibrator was turned on for 15 minutes during each hour each day(0800-1800) for 11 days experimental period. The oxygen consumption (OC) of S. asotus the beginning of the experiment (0 day) in 58 dB group after 1, 5, 9 and 11 days was decreased 21.8, 30.2, 36.0 and 53.2%, respectively. In 68 group after 1, 7 and 11 days was decreased 22.7, 35.1 and 57.7%, respectively. The OC decreased exponentially and the relationship between them was expressed as OC = 0.374D + 90.762 ($r^2=0.048$) at 48 dB, OC = -3.581D + 89.520 ($r^2=0.831$) at 58 dB and OC = -4.109D + 90.907 ($r^2=0.884$) at 68 dB. Ammonia excretion (AE) of the beginning of the experiment in 48, 58 and 68 groups after 1 day was increased by 34.8, 51.8 and 63.2%, respectively, but it was decreased significantly from 3 to 11 days. The AE increased exponentially and the relationship between them was expressed as AE = -1.646D + 115.915 ($r^2=0.265$) at 48 dB, AE = -8.230D + 122.132 ($r^2=0.750$) at 58 dB and AE = -7.086D + 123.690 ($r^2=0.614$) at 68 dB.