• Title/Summary/Keyword: 7q34

Search Result 145, Processing Time 0.032 seconds

A NOTE ON THE WEIGHTED q-GENOCCHI NUMBERS AND POLYNOMIALS WITH THEIR INTERPOLATION FUNCTION

  • Arac, Serkan;Ackgoz, Mehmet;Seo, Jong-Jin
    • Honam Mathematical Journal
    • /
    • v.34 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • Recently, T. Kim has introduced and analysed the q-Bernoulli numbers and polynomials with weight ${\alpha}$ cf.[7]. By the same motivaton, we also give some interesting properties of the q-Genocchi numbers and polynomials with weight ${\alpha}$. Also, we derive the q-extensions of zeta type functions with weight from the Mellin transformation of this generating function which interpolates the q-Genocchi polynomials with weight at negative integers.

High Efficiency Q-band MIMIC HEMT-Oscillator Operating at Low Voltages (고효율 및 저전압 동작 특성의 Q-band MIMIC HEMT발진기)

  • Lee, Mun-Kyo;An, Dan;Lee, Bok-Hyung;Kim, Sung-Chan;Lim, Byeong-Ok;Han, Hyo-Jong;Chae, Yeon-Sik;Shin, Dong-Hoon;Kim, Yong-Hoh;Park, Hyung-Moo;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.4
    • /
    • pp.45-50
    • /
    • 2004
  • In this paper, we present the low voltage and high efficiency Q-band MIMIC oscillator using device-level power combined structure. The oscillator was successfully integrated by using 0.1 ${\mu}{\textrm}{m}$ GaAs PHEMTS and the CPW transmission line. We show that the highest efficiency is 19 % with an output power of 2.6 ㏈m at a frequency of 34.56 ㎓. The operating voltage of the oscillator is 2.2 V which is lower voltage than that of previously reported oscillators at Q-band. And the maximum output power of 6.7 ㏈m was obtained at a frequency of 34.56 ㎓.

Design of an Improved Anti-Collision Unit for an RFID Reader System Based on Gen2 (Gen2 리더 시스템의 개선된 충돌방지 유닛 설계)

  • Sim, Jae-Hee;Lee, Yong-Joo;Lee, Yong-Surk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.2A
    • /
    • pp.177-183
    • /
    • 2009
  • In this paper, we propose an improved anti-collision algorithm. We have designed an anti-collision unit using this algorithm for the 18000-6 Type C Class 1 Generation 2 standard (Gen2). The Gen2 standard uses a Q-algorithm for incremental method on the Dynamic Slot-Aloha algorithm. It has basically enhanced performance over the Slot-Aloha algorithm. Unfortunately, there are several non-clarified parts: initial $Q_{fp}$ value, weighted C, and the ending point of the algorithm. If an incorrect value is selected, it causes degradation in performance. Thus we propose an improved anti-collision algorithm by clearly defining the vague parts of the existing algorithm. Simulation results showed an improved performance of up to 34.8% using an optimized value of C and the initial $Q_{fp}$ value. With the ending condition, performance is 34.7%. The anti-collision unit is designed using the Verilog HDL. The module was synthesized using Synopsys' Design Compiler and the TSMC $0.2{\mu}m$ standard cell library. The synthesized result yielded 3,847 gates, and was guaranteed under the proposed working frequency of 19.2MHz.

Identification of Tumor Suppressor Loci on the Long Arm of Chromosome 5 in Primary Small Cell Lung Cancers (원발성 소세포폐암에서 염색체 5번의 장완에 위치한 종양억제유전자좌의 확인)

  • Cho, Eun-Song;Kim, Ho-Guen;Cho, Chul-Ho;Chang, Joon;Chung, Kyung-Young;Kim, Young-Sam;Park, Jae-Min;Kim, Sung-Kyu;Kim, Se-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.1
    • /
    • pp.49-59
    • /
    • 2000
  • Backgrounds : Recent cytogenetic studies indicated that long of the long arm of chromosome 5 is a frequent event in small cell lung canær (SCLC), suggesting the presence of a tumor suppressor gene in its place. To map the precise tumor-suppressor loci on the chromosome arm for further positional cloning efforts, we tested 15 primary SCLCs. Methods : The DNAs extracted from paraffin-embedded tissue blocks with primary tumor and corresponding control tissue were investigated. Nineteen polymorphic microsatellite markers located in the long arm of chromosome 5 were used in the microsatellite analysis. Results : We found that ten (66.7%) of 15 tumors exhibited LOH in at least one of tested microsatellite markers. Two (13%) of 10 tumors exhibiting LOH lost a larger area in chromosome 5q. LOH was observed in five common deleted regions at 5q. Among those areas, LOH between 5q34-qter and 5q35.2-35.3 was most frequent (75%). LOH was also observed in more than 50% of the tumors at four other regions, between 5q14-15 and 5q23-31, 5q31.1, 5q31.3-33.3, and 5q34-35. Three of 15 tumors exhibited shifted bands in at least one of the tested microsatellite markers. Shifted bands occurred in 2.5% (7 of 285) of the loci tested. Conclusion : Our data demonstrated that at least five tumor-suppressor loci exist in the long arm of chromosome 5 and that they may play an important role in small cell lung cancer tumorigenesis.

  • PDF

Cytogenetic Analysis in Korean Head and Neck Cancer Cell Lines: Comparative Genomic Hybridization(CGH) and Array-CGH (두경부 편평상피세포암 세포주의 염색체 이상 분석: 비교유전체보합법과 Array 비교유전체보합법)

  • Shin, You-Ree;Park, Soo-Yeun;Lee, Dong-Wook;Kim, Han-Su;Go, Young-Min;Park, Hyun-Joo;Choung, Sung-Min
    • Korean Journal of Head & Neck Oncology
    • /
    • v.24 no.1
    • /
    • pp.33-42
    • /
    • 2008
  • Head and neck squamous cell carcinoma(HNSCC) is notorious for its poor outcome and increasing incidence. But, the studies of cytogenetic analysis in HNSCC are relatively rare, because of difficulties in culturing solid tumor cells and complexity in chromosomal DNA abberations associated with the lesions. The purpose of this study is to evaluate the location of chromosomal aberrations in Korean HNSCC cell lines (SNU-1041, 1066, and 1076) with comparative genomic hybridization(CGH) and array based CGH(array-CGH). Chromosomal gains of 3q23-q27, 5p13-p15.3, 7p21-pter, 8q11.2-q12, 8q21.1-qter, 9q22-q34, 16q22-q24, and 20q11.2-qter, as well as chromosomal losses on 3p10-p14 were found in all 3 SNU cell lines. Losses on 3p15- p23, 4q22-q27, 4q31.3-qter, 6q14-q15, 7q31-q34, 8p12-pter, 18q21-q23, and 21q11.2-q12 were observed in 2 of 3 cell lines. In array-CGH, many genes were altered including gains of PIK3CA, MYC, EVI1, MAD1L1 genes and losses of SERPIN genes. These aberrations of gene and chromosome coincide with other results of study, generally. These data about the patterns of chromosomal aberrations could be a basic step for understanding more detailed genetic events in the carcinogenesis and also provide information for diagosis and treatment in HNSCC.

REPDIGITS AS DIFFERENCE OF TWO PELL OR PELL-LUCAS NUMBERS

  • Fatih Erduvan;Refik Keskin
    • Korean Journal of Mathematics
    • /
    • v.31 no.1
    • /
    • pp.63-73
    • /
    • 2023
  • In this paper, we determine all repdigits, which are difference of two Pell and Pell-Lucas numbers. It is shown that the largest repdigit which is difference of two Pell numbers is 99 = 169 - 70 = P7 - P6 and the largest repdigit which is difference of two Pell-Lucas numbers is 444 = 478 - 34 = Q7 - Q4.

Clonal Variation of Physical Characteristics and Mineral Composition in Acorn of Quercus acutissima and Q. serrata Seed Orchard

  • Kim, Chang-Soo;Kim, Du-Hyun;Han, Sang-Urk;Shim, Tae-Heum
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.47-55
    • /
    • 2011
  • This study investigated mineral element concentrations of acorns in Quercus acutissima and Quercus serrata seed orchard, so that to estimate the variation of these species based on the chemical composition in different clones from plus trees. The acorns were collected from ten clones of each species grown in the same clonal seed orchard. The nutritional concentration of acorns was significantly different between the clones and species. The concentration of nutrient for the whole acorn followed in this general sequence: P > K > Na > Mg > Ca > Mn > Fe > Zn > Cu. The mineral concentrations of acorns in clones of Q. acutissima and Q. serrata contained P (494 to 684 and 541 to 672 mg/100 g), K (114 to 569 and 140 to 251 mg/100 g), Na (57 to 121 and 49 to 85 mg/100 g), Mg (29 to 37 and 26 to 42 mg/100 g), Ca (10 to 53 and 26 to 68 mg/100 g), Mn (0.5 to 3.4 and 1.8 to 4.5 mg/100 g), Fe (0.7 to 1.1 and 0.0 to 2.2 mg/100 g), Zn (0.34 to 0.81 and 0.38 to 0.84 mg/100 g), and Cu (0.13 to 0.40 and 0.09 to 0.34 mg/100 g) respectively. Even though acorns of Q. serrata are smaller in size than Q. acutissima, acorns of Q. serrata contained significantly higher concentration of phosphorus, calcium, iron and manganese than Q. acutissima. Based on the mineral composition of the acorns, this study has shown that the clones of Q. acutissima and Q. serrata have different ability to accumulate mineral nutrients which could indicate the variation of Quercus species in terms of mineral acquisition and accumulation.

Frequency Characteristics for Micro-scale SMD RE Chip Inductors of Solenoid-Type (Solenoid 형태의 초소형 SMD RF 칩 인덕터에 대한 주파수 특성)

  • Kim, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.454-459
    • /
    • 2007
  • In this work, micro-scale, high-performance solenoid-type RF chip inductors utilizing amorphous $Al_2O_3$ core material were investigated. The size of the chip inductors was $0.86{\times}0.46{\times}0.45mm^3$ and copper(Cu) wire with $27{\mu}m$ diameter was used as the coil. High frequency characteristics of the inductance(L), quality factor(Q), impedance(Z), and equivalent circuit parameters of the RE chip inductors were measured and analyzed using an RF impedance/material analyzer(HP4291B with HP16193A test fixture). It was observed that the RF chip inductors with the number of turns of 9 to 12 have the inductance of 21 to 34nH and exhibit the self-resonant frequency(SRF) of 5.7 to 3.7GHz. The SRF of inductors decreases with increasing the inductance and inductors have the quality factor of 38 to 49 in the frequency range of 900MHz to 1,7GHz.

  • PDF

A Study on the Correlation between Standard Penetration Resistance Value and Static Cone Penetration Resistance Value of the Soft Ground Subsurface of Yongdong Area (표준관입저항치와 정적콘관입저항치의 상관성에 관한 연구 - 영동지역의 연약지반을 중심으로 -)

  • Kim, Jinam;Park, Heunggyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.5
    • /
    • pp.13-20
    • /
    • 2006
  • We have conducted standard penetration tests and static cone penetration tests that are widely used the land base examination on the soft ground subsurface of Yongdong area, and examined the correlation between them. We have also made a comparative analysis of the correlation between the indoor tests on the materials collected on the site and on-the-spot penetration tests. The results are as follows : The relationship between Standard Penetration Test N-value and Dutch Cone Tset show $Q_c=1.93N+0.29$ for organic soil, $Q_c=2.19N+0.20$ for clay, $Q_c=2.34N+1.06$ for silt, $Q_c=3.02N+0.54$ for silty sand, and $Q_c=3.47N+0.46$ for sand. In this case of sand $Q_c/N$ increases when the soil particles are larger. The relationship between standard penetration test N-value and Unconfined Compression Strength $q_u$ show $q_u=0.11N+0.03$ for organic soil, $q_u=0.11N+0.25$ for clay, and $q_u=0.18N-0.03$ for silt.

  • PDF