• 제목/요약/키워드: 7mm or less

검색결과 364건 처리시간 0.027초

도시 저소득층 여자노인의 고지혈증과 관련된 우울정도와 식생활 요인에 관한 연구 (Depression and Dietary Factors Related to Hyperlipidemia in Urban Living Elderly Female from Low Income Group)

  • 손숙미;박진경;이홍섭
    • 대한지역사회영양학회지
    • /
    • 제8권6호
    • /
    • pp.938-950
    • /
    • 2003
  • We conducted a case-control study to examine the relationship of depression and dietary related factors with the hyperlipidemia for urban living elderly women from low income group. The case group consisted of 45 elderly females with hyperlipidemia (serum cholesterol $\geq$ 240mg/dl or serum TG $\geq$ 250mg/dl and the control group of 95 age matched elderly women with serum cholesterol levels less than 240mg/dl and serum TG less than 250mg/dl. In a univariate analysis, vitamin C intake, the number of family members living with the subject, and their depression scores were significantly higher in the hyperlipidemic group than in the control group. In the logistic regression analysis, the vitamin C intake ($\geq$75% Korean RDA), the number of family members living with the subject ($\geq$ 1), depression scores ($\geq$7), BMI ($\geq$27), and subscapular skinfold thickness ($\geq$18mm) were associated with significantly higher (p<0.05) risks of hyperlipidemia in the elderly women. However after adjustment for other covariables, the depression scores (Odds Ratio 2.48 for depression score$\geq$7;95%CI:1.10-5.60) and subscapular skinfold thicknesses (Odds Ratio 5.69 for SBT$\geq$18mm, 95%CI:1.87-17.32) were the significant risk factors associated with hyperlipidemia in the elderly women.

USE OF MOLD INHIBITOR FOR FEED STORAGE AND IMPROVED CHICK PERFORMANCE

  • Nahm, K.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제4권3호
    • /
    • pp.285-291
    • /
    • 1991
  • Two experiments were conducted to evaluate the effect of mold inhibitor in the ration which had two different protein levels (18% and 12%) and two different particle sizes (80 or 40% of the particles in the ration less than 1.19 mm). The experimental diets with ave. 12.7% moisture which were treated at the level of 0.1% mold inhibitor were stored under 85% humidity and at $29{\pm}1^{\circ}C$ for 10 to 40 days. In experiment 1, after 40 days of storage the $CO_2$ production in the feed treated with mold inhibitor was higher (p < 0.01) than when 40% of the ration's panicle size was 1.19 mm. Aflatoxin production in the experimental diet with mold inhibitor was affected (p<0.05) by the levels of protein and the different particle size ranges after 40 days storage. The interaction of protein levels and particle size ranges on the anatoxin and $CO_2$ production was significant (p<0.05) at 40 days storage. In experiment 2, there was a decrease in total body weight gain and total feed intake observed in chicks fed the untreated diet of 18% protein with 40% of the particles in the ration less than 1.19 mm stored for 40 days. Feed conversion was depressed (p<0.05) in the chicks fed the untreated diets of both particle sizes. Particle size X types of feed interaction in feed conversion was significant (p<0.05).

착색단고추 시설하우스에서 작은뿌리파리(Bradysia agrestis)의 간이예찰 기술 개발 (Development of Simple Monitoring Techniques of Fungus Gnats, Bradysia agrestis (Diptera: Sciaridae) Larva and Adult in Sweet Pepper Greenhouse)

  • 전흥용;김형환;양창열;조명래;임명순;추호렬
    • 한국응용곤충학회지
    • /
    • 제43권2호
    • /
    • pp.129-134
    • /
    • 2004
  • 착색단고추에 발생하여 피해를 주고 있는 작은뿌리파리의 포장 발생 실태를 간단하고 손쉽게 간이예찰 할 수 있는 방법에 대하여 시험을 수행하였다. 작은뿌리파리의 유충은 감자, 고구마, 당근, 마늘, 무, 양파 절편중에서 감자 절편에 많은 수가 유인되었으며, 유인수는 각각 9.7마리, 6.0마리, 4.3마리, 0.7마리, 3.8마리, 1.0마리였다. 유충 유인수는 10${\times}$10${\times}$10mm에서 2.1마리, 20${\times}$20${\times}$10mm에서 3.4마리, 30${\times}$30${\times}$10mm에서 3.9마리로 절편의 표면적이 클수록 유인수가 많았다. 성충은 노란색 끈끈이트랩에 50.0마리가 유인되어 흰색에서 18.0마리, 파란색에서 3.7마리보다 유인수가 많았다. 끈끈이트랩 설치 높이별 성충 유인수는 암면배지로부터 50cm이하에서 50.0마리,50-100cm에서 4.3마리, 100cm이상에서 2.0마리가 유인되어 50cm이하에 설치하는 것이 효과적이었다.

아말감과 이종(異種)금속의 거리에 따른 부식에 대한 고찰 (A Study on Corrosion according to Distance between Amalgam and Dissimilar Metals)

  • 김주원;정은경
    • 치위생과학회지
    • /
    • 제4권3호
    • /
    • pp.103-109
    • /
    • 2004
  • 본 실험은 제조회사 매뉴얼과 통법에 의해서 Amalgam 합금, Ni-Cr alloy의 Crown용 Verabond, Denture용 Talladium $^{TM}alloy$로 각각 24개의 총 72의 시편을 하악 제1대구치근 원심 치관 폭경과 임상에서의 MOD cavity를 고려하여 제작하였고 인공 타액 80ml를 담은 200ml 용 비이커에 시편을 넣어 0mm, 7mm, 40mm 거리에서 7일 후 갈바닉 부식을 측정하였다. 유리금속은 유도 플라즈마 방출 분광기(Inductively Coupled Plasma - Atomic Emission Spectrometer(ICP-AES, JY-50P, VG Elemental Co. France)로 전해액내의 Cu, Ag, Ni, Cr, Sn, Zn, Hg를 정량 분석했으며 그 결과 다음과 같은 결론을 얻었다. 첫째, Cu, Sn, Ag, Hg, Zn은 아말감이 금 합금과 접촉했을 때가 크라운용 Ni-Cr alloy와 덴쳐용 Talladium alloy 보다 아주 많이 유리 했으며 금 합금이 구강조직과 생체 적합성이 가장 좋다지만 아말감과 함께 있을 때 가장 불리 했슴을 알 수 있었다. 둘째, 아말감이 금 합금과 접촉했을 때, 금 합금의 조성에서 Ni, Cr 같은 중금속이 함유되지 않았기 때문인지 전혀 유리되지 않았으나 Sn은 조성에는 없었지만 $227.1{\pm}18.0035{\mu}g/cm^2$나 유리 되었고 Hg도 유리되었는데 이는 아말감 자체의 유리 물질임을 추측할 수 있었다. 셋째, 아말감 합금과 금 합금 사이에서의 0mm, 7mm, 40mm 거리에서는 Cu, Ag는 유의성이 있었으며 Hg는 유의성이 없었다. 이는 금합금은 절대 아말감과 같이 사용해서 안되며 이종 보철물 사이의 거리에 관계없이 사용을 금해야 하는 것으로 사료된다. 넷째, 아말감합금이 Crown용 Ni-Cr 합금과 접촉했을 때 아말감의 Ag이 유리 되지 않았으며 Zn, Ni, Sn, Hg, Cu의 순으로 유리되었다. 0mm, 7mm, 40mm 거리에 따라서 유의성이 있었다. Hg는 유리 되지 않았지만 중금속인 Ni, Cr은 유리되었고 반대 악궁이나 거리가 떨어져 있으면 접촉보다 Hg의 유리가 적었다. 다섯째, 아말감합금이 Denture용 Talladium alloy 합금과 접촉했을 때 0mm, 7mm, 40mm 거리에서도 유의성이 있었다. 0mm, 7mm, 40mm 거리에 따라서 유의성이 있었다. Hg는 유리 되지 않았지만 중금속인 Ni, Cr은 유리되었고 반대 악궁이나 거리가 떨어져 있으면 접촉보다 Hg의 유리가 적었다. 여섯째, 인공 타액에서 접촉 시 Amalgam alloy와 Gold, Verabond, Talladium alloy의 Cu, Sn, Ag, Hg, Zn, Ni, Cr의 ICPES 검사 결과 Cu, Hg가 유의성을 있었다. 일곱째, 인공타액에서 아말감합금과 두 비귀금속인 Ni-Cr alloy(crown용), Denture용 Talladium alloy가 접촉한 경우 거리에 따른 Hg, Ni, Cr의 유리 부산물에서 유의성을 확인했다.

  • PDF

광대역 특성을 갖는 3층형 페라이트 전파흡수체의 설계 (A Design of Ferrite Electromagnetic Wave Absorber Three Layered Type with Wide-Band Characteristics.)

  • 이창우;김동일
    • 한국항해학회지
    • /
    • 제22권4호
    • /
    • pp.51-57
    • /
    • 1998
  • According to the rapid development of the electric industry, the demand of the frequency allocation and the usage of electromagnetic wave are increased due to automation of modem society. Electromagnetic wave absorbers for anechoic chamber are needed to broaden the effective frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve the above requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the effective frequency bandwidth by the way of forming air layer(practically in urethane foam, etc.) on the ferrite tile. Therefore, an air layer is formed between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 400 MHz in bandwidth. In this paper, a broadband electromagnetic wave absorber are designed, which has the reflection characteristics less than -20 dB from 30 MHz to 8,000 MHz in the bandwidth. A super broadband electromagnetic wave absorber is achieved by inserting square Ferrite Cylinders Type with the thickness less than 23.5 mm and with the frequency band from 30 MHz to 8,000 MHz under the above tolerance limits. The purpose of this research is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell and also a wall material for preventing TV ghost, etc.

  • PDF

Interaction of Nitric Oxide and Renin Angiotensin System in Pulmonary Arterial Circulation of RHR

  • Lee, Byung-Ho;Shin, Hwa-Sup
    • Archives of Pharmacal Research
    • /
    • 제20권5호
    • /
    • pp.389-395
    • /
    • 1997
  • We investigated the interaction between nitric oxide and the renin angiotensin system in regulating isolated pulmonary arterial tension and pulmonary arterial pressure (PAP) in renal hypertensive rats (RHR) made by complete ligation of left renal artery. Losartan induced a depressor response that was smaller in RHR than in normotensive rats (NR) (3.3 and 7.0 mmHg, respectively, at 3.0 mg/kg, p<0.05), and the response was significantly reduced by $N^{G}$-nitro-Larginine methyl ester (L-NAME). Angiotensin II elevated the PAP (7.6 and 10.8 mmHg at $0.1 {\mu}g/kg$; 20.3 and 23.6 mmHg at $1.0{\mu}g/kg$, respectively) and contracted the isolated pulmonary artery ($pD_2$: 8.79 and 8.71, respectively) from both NR and RHR with similar magnitude, and these effects were significantly enhanced by L-NAME in NR, but not in RHR. Acetylcholine lowered the PAP slightly less effectively in RHR than in NR (3.8 and 6.0 mmHg at 10 .mu.g/kg, respectively) and relaxed the pulmonary artery precontracted with norepinephrine in both rats with similar magnitude ($E_max$: 60.8 and 63.6%, respectively), and the effect being completely abolished after pretreatment.with L-NAME or removal of endothelial cells. These results suggest that nitric oxide interacts with renin angiotensin system to control the pulmonary vascular tension and pulmonary arterial circulation of RHR.R.

  • PDF

동종 슬개건을 이용한 전방십자인대 재건술 (Reconstruction of Anterior Cruciate Ligament With Bone-Patellar tendon-Bone Allograft)

  • 전철홍;이병창;김영진;양환덕
    • 대한관절경학회지
    • /
    • 제3권2호
    • /
    • pp.102-108
    • /
    • 1999
  • 목 적 : 술 전 장력유지 장치를 사용하지 않고 동종 골-슬개건-골 이식건으로 전방십자인대 재건술을 시행한 후 임상적 결과를 조사하여 보았다. 대상 및 방법 : 동종 골-슬개건-골 이식건을 이용 관절경하에 전방십자인대 재건술을 시행한 환자 중 2년 이상 추시가 가능한 43명, 46례로 주관적, 객관적 지표, Telos stress arthrometer, modified Feagin Scoring System을 이용해 분석하였다. 수술 시 평균 연령은 27세(18~42세), 평균 추시 기간은 41개월(24~79개월)이었다. 동종 골-슬개건-골 이식건은 술 전에 재수분화 시켰으며, 술 전 장력유지 장치를 이용한 장력은 주지 않았고, 관절경하에서 이중터널 방법을 이용하여 이식건을 이식하고, 슬관절 굴곡 및 신연을 통한 이식건의 장력을 주고 간섭 나사못을 사용하여 고정하였다. 결 과 : Lysholm knee score는 술 전 60점에서 84점으로 24점 증가를 보였고, Telos arthrometer를 이용한 전방 스트레스 단순 방사선 사진상 술 전 7.1mm에서 술 후 2.3mm로 향상되었다. 추시 상 슬관절 운동능력은 정상이었고, 신전 시 굴곡 구축은 보이지 않았으며, modified Feagin Scoring System상 양호 이상이 39례(84.7%)이었다. 결 론 : 동종 골-슬개건-골 이식건을 이용한 전방십자인대 재건술의 임상적 결과는 자가 골-슬개건-골 이식건을 이용한 방법에 비해 큰 차이를 보이지 않았으며, 수술 전의 장력유지 장치를 사용하지 않아도 임상적으로 큰 영향이 없었다. 따라서 동종 골-슬개건-골 이식건은 여러 가지 문제점을 지닌 자가 골-슬개건-골 이식건의 대용으로 사용이 기능할 것으로 사료된다.

  • PDF

황아귀, Lophius litulon (Jordan)의 자어기의 형태 (ON THE MORPHOLOGY OF LARVAL STAGES OF LOPHIUS LITULON (JORDAN))

  • 김용억
    • 한국수산과학회지
    • /
    • 제9권4호
    • /
    • pp.273-280
    • /
    • 1976
  • 1976년 6월 20일에 해운대 동백섬 연안에서 채집된 황아귀의 자어를 재료로 하여 초기생활사에 따른 형태변화 과정중 등지느러미 이극, 배지느러미, 색소포 및 소화관의 발적과정과 아가미, 새조 및 치아등의 형성과정에 관하여 관찰하였다. 1. 제1등지느러미 제1극의 원기는 부화직후인 2.7mm 전후에 생겨나 6.30mm 전후에서 극의 형태로 분화되며, 제2극은 5.82mm 전후에 원기가 나타나고 제3극은 6.45mm 전후에서 원기가 나타나 분화되는 것같다. 2. 배지느러미는 2.7mm 전후에 가슴지느러미의 바로 뒤쪽에서 원기가 나타나고, 처음에는 반원형으로 솟아나듯 하든 것이 차츰 발달함에 따라 뒤쪽으로 향해 곤봉상으로 길어지고, 전장 6.35mm 전후에서 전장의 1/2 정도의 크기로 발달하며, 가는 두 줄의 지느러미 줄기가 나타난다. 3. 색소포의 발달은 특히 미부에 있어서 2단계로 구분할 수 있는데, 부화직후(2.7mm 전후) 미부에 불규칙 9열로 분포하는 경우와 시일이 경과함에 따라 전장 4.25mm전후에는 뚜렷한 3개의 색소포군을 형성하는 경우를 들 수 있다. 4. 소화관은 부화직후인 2.7mm 전후에 창자의 시흔이 나타나기 시작하며 전장 5.4mm 전후에 난황이 축소되면서 창자의 굴곡등 소화관의 윤곽이 뚜렷해질 뿐만 아니라 입도 열리는 것 같다. 5. 아가미는 전장 6.35mm 전후에 시흔이 보이며 발달하기 시작하고 치아는 전장 6.25mm 전후에 원기가 나타나고 새조는 6.45mm 전후에 5개의 새조골을 볼 수 있다.

  • PDF

THERMALHYDRAULIC EVALUATIONS FOR A CANFLEX BUNDLE WITH NATURAL OR RECYCLED URANIUM FUEL IN THE UNCREPT AND CREPT CHANNELS OF A CANDU-6 REACTOR

  • Jun, Ji-Su
    • Nuclear Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.479-490
    • /
    • 2005
  • The thermalhydraulic performance of a CANDU-6 reactor loaded with various CANFLEX fuel bundles is evaluated by the NUCIRC code, which is incorporated with recent models of pressure drop and critical heat flux (CHF) predictions based on high-pressure steam-water tests for the CANFLEX bundle as well as a 37-element bundle. The distributions of channel flow rate, channel exit quality, critical channel power (CCP), and critical power ratio (CPR) for the CANFLEX bundles (with natural or recycled uranium fuel) in the CANDU-6 reactor fuel channel are calculated by the code. The effects of axial and radial heat flux on CCP are evaluated by assuming that the recycled uranium fuel (CANFLEX-RU) has the same geometric data as the natural uranium fuel bundle (CANFLEX-NU), but a different power distribution due to different fuel composition and refueling scheme. In addition, the effects of pressure tube creep and bearing-pad height are examined by comparing various results of uncrept, and $3.3\%\;and\;5.1\%$ crept channels loaded with CANFLEX bundles with 1.4 mm or 1.7 mm high bearing-pads with those of the 37-element bundle. The distributions of the channel flow rate and CCP for the CANFLEX-NU or -RU bundle show a typical trend for a CANDU-6 reactor channel, and the CPRs are maintained above at least 1.444 (NU) or 1.455 (RU) in the uncrept channel. The enhanced CHF of the CANFLEX bundle (particularly with 1.7mm height bearing-pads) produces a higher thermal margin and considerably less sensitivity to CCP reduction due to the pressure tube creep than the 37-element bundle. The CCP enhancement due to the raised bearing-pads is estimated to be about $3\%\~5\%$ for the CANFLEX-NU and $2\%\~6\%$ for the CANFLEX-RU bundle, respectively.

Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교 (Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA))

  • 정태섭;주진양;안창수
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.94-102
    • /
    • 1997
  • 목적: 자기공명혈관조영술(magnetic resonance angiography: MRA)을 이용하여 뇌동맥류를 비침습적 방법으로 진단하고자 하는 시도가 있었지만 크기가 3mm 이하인 경우 진단에 애로가 많았다. 뇌동맥류의 진단에 있어 최근 개발된 고해상도, 고속의 slice interpolation 자기 공명혈관조영술과 디지탈 감산 혈관조영술(digital subtraction angiography: DSA)의 결과를 전향적으로 비교하여 보편적인 선별 검사법으로 가능성을 확인하고자 하였다. 대상 및 방법: 총 19명의 환자에서 26개의 뇌동맥류를 대상으로 하였다. 모두 자기공명혈관조영술을 먼저 촬영하여 기원혈관, 동맥류경부의 확인, 인근 작은 혈관과의 연관관계등을 확인한 후 디지탈 감산 혈관조영술을 시행하여 비교하였다. 영상은 1.5T 초전도형기계(Vision, Siemens, erlangen, Germany)를 이용하여 slice interpolation 을 이용한 자기공명혈관조영술로 촬영하였다. 촬영은 TR / TE / FA = 30 / 6.4 / 25, matrix $512{\times}160$, 관찰면 $200{\times}150$, 촬영시간 7분 42초, 유효 두께 0.7mm, 총 두께가 102.2mm로 하여 대공(foramen magnum)에서 전뇌동맥(anterior cerebral artery)의 A3 부위까지 충분히 포함되도록 하였다. 영상분석은 최대강도투사(maximum intensity projection: MIP)를 사용하였으며 두개강내 동맥류가 있는 경우 다면재구성(multiplanar reconstruction: MPR) 기법을 사용하였다. 결과: 19명의 환자중 2명이 3개, 3명이 2개, 나머지 14명이 각각 1개씩의 두개강내 동맥류를 가져 모두 26개 였으며 파열된 동맥류가 14개였고 파열되지 않은 동맥류가 12 개이었다. 크기가 2mm 이하가 8개, 3-5mm가 9개, 6-9mm가 7개이며 10mm이상이 2개가 있었다. 처음 검사에서 자기공명혈관조영술과 디지탈 감산 혈관조영술에서 23개의 동맥류중 내경동맥에 1mm 크기의 동맥류 1개를 제외한 25개를 각각 발견할 수 있어 96%의 예민도를 보였으나 진음성과 위음성은 없어 특이도를 측정할 수 없었다. 크기와 모양을 확인하는데 자기공명혈과조영술과 다면재구성을 동시에 사용한 경우 디지탈 감산 혈관조영술과 같은 성적을 보인 반면 동맥류 경부와 기원혈관을 확인하는데도 자기공명혈관조영술의 다면재구성을 동시에 사용한 경우가 자기공명혈관조영술 또는 디지탈 감산 혈관조영술만 사용한 경우 보다 월등히 좋았다. 결론: Slice interpolation 기법을 이용한 고해상 자기공명혈관조영술은 두개강내 동맥류를 검사하는데 디지탈 감산 혈관조영술과 동일한 성적을 보여 앞으로 비침습적 일차 선별 검사법으로 가능할 것으로 생각된다.

  • PDF