• Title/Summary/Keyword: 7일 유량

Search Result 236, Processing Time 0.065 seconds

Studies on the Red Pigment Produced by Monascus sp. in Submerged Culture. Part I Isolation of Strain and Cultural Conditions of Pigment Produced (액침진탕 배양에 의한 Monascus sp..가 생산하는 적색색소에 관한 연구 제1보 균주의 분리 및 색소생산 배양 조건)

  • 김현수;김두현;양호석;변유량;유주현
    • Microbiology and Biotechnology Letters
    • /
    • v.7 no.1
    • /
    • pp.23-30
    • /
    • 1979
  • Fungi which produce red pigment were isolated from tapioca chips, Korean Koji, air, and plant leaves. Among the Fungi, T-1 strain was selected as test strain. This strain was identified as a Monatcus sp. by the morphological propeties. Various culture conditions, and physical and physiological characteristics of red pigment were studied. According to the studies of culture conditions, optimum condition was found to be pH 6.5; 4 days of incubation; temperature, 32~33 c: 3.5% of Tapioca chips powder as carbon source, 0.2% of sodium nitrate as nitrogen source and 100 ml of medium in the 500 ml Erlenmyer flask at a rotary shaker (rpm180) as aeration condition. Also effective levels of vitamins, amino acids and inorganic compounds was found to be l$\mu\textrm{g}$/ml of folic acid and niacin; 0.3% of L-arginine, L-glutamic acid and L-proline; and 0.001% of manganese dioxide giving good results.

  • PDF

The Effect of Organic Acids on Dewatering Efficiency of Soybean Milk Residue by Hydraulic Press (유기산이 두유박의 압착 탈수율에 미치는 영향)

  • Pyun, Yu-Ryang;Cho, Won-Il;Lee, Yoon-Su;Kwon, Ick-Boo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.638-643
    • /
    • 1996
  • The efficiency of dewatering of soybean milk residue was improved by hydraulic pressing after pH adjustment to 4.5 with organic acids such as acetic and lactic acids. Water content of raw soybean milk residue was reduced from 80% to 72% by pressing after pH adjustment, while only to 78% by the conventional hydraulic press. The water content of the residue after pH adjustment was further reduced to 63% by hydraulic pressing with ohmic heating. The pH adjustment facilitated separation of cake from the filter cloth and reduced the solid content of the expressed liquid from 10 to 3%.

  • PDF

CFD analysis of CO detecting device in household gas boiler (가정용 가스 보일러 CO발생 검지 장치 전산해석)

  • Hwang Jae-Soon;Park Ju-Won;Shin Dong-Hoon;Chung Tae-Yong;Chae Jae-Ou;Choi Kyung-Suhk
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2006.05a
    • /
    • pp.164-169
    • /
    • 2006
  • 본 연구는 가정용 가스 보일러의 배기가스 유동특성을 전산유체역학을 이용하여 정밀 분석하고 CO 검지 장치의 최적화 설계를 결정하는 것을 목적으로, CFD 상용코드 FLUENT 6.2를 이용하였다. 배기가스 포집위치에서 가스 유속의 균일성과 CO농도 검출기에서의 속도가 주요 성능 인자이며 포집기의 위치, 포집구멍의 크기 및 배기가스의 유량을 주요 변수로 선택하였다. 포집기의 위치는 배기부의 상부와 하부인 두가지의 경우이고 두 경우의 배관 높이 차이는 10 mm이다. 포집구멍의 직경 변화는 3 mm, 4 mm 및 5 mm인 세가지 경우이다. 마지막 변수인 배기가스의 유입속도는 20,000 kcal/hr용량의 k사 가스 보일러가 공기비 1.1일 경우에 정상 연소시 0.5 m/s임을 알았고 저부하와 고부하일 경우를 고려해서 0.3 m/s, 0.5 m/s 및 0.7 m/s의 세가지 경우를 변수로 결정하여 총 18가지 형태의 대상을 전산유체 역학을 통해서 분석하였다. 궁극적인 목표였던 배기가스의 균일성은 한가지 경우를 제외 하고는 만족할만한 결과를 얻었기 때문에 CO검지 장치가 위치할 곳에서의 속도 및 포집구멍의 크기가 CO농도 검출기 유속의 주요 인자라 할 수 있다. 결론적으로 포집구멍의 크기가 5 mm인 6가지 경우 중에서 두가지 경우는 검지장치의 유효속도를 초과하였고 포집구멍의 크기가 3 mm인 경우는 검지장치의 유입 속도가 상대적으로 작으므로 포집구멍의 크기는 4 mm가 적합한 것으로 판단하였다.

  • PDF

Analysis on Features of Streamwater usage in Nakdong-River (낙동강 유역의 하천수 사용 특성 분석)

  • Choi, Kyu-Hyun;Hong, Sung-Hun;Kim, Joung-Ho;Song, In-Kwon;Kim, Min-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1375-1379
    • /
    • 2010
  • 물관리 주무부처인 국토해양부(이하 국토부)는 최근의 전 세계적인 기후변화와 더불어 유역의 도시화 등으로 인해 급격한 하천환경 및 사회적 여건변화에 맞추어 "하천법"을 전부개정(법률 제8338호)하여 2008년 4월 7일부터 시행하고 있다. 개정 "하천법"에서는 하천수 사용 관리 조정기능이 크게 강화되어 국가 및 지방하천에서 하천수를 취수하여 특정용도로 사용하려는 경우, 그 취수량에 관계없이 누구나 관할 홍수통제소장에게 허가를 받아야한다. 따라서 국토부 소속기관이자 국가 물관리 전문기관인 홍수통제소는 수문조사, 이수(하천유량 관리 등) 및 치수(홍수예보 등) 등의 주요업무 중 기존 국가하천에 국한되었던 하천수사용 관리를 지방하천까지 확대하게 되었다. 본 연구에서는 하천법에 따라 집행된 2009년 국가하천, 지방하천 및 일시적인 하천수 사용 인 허가 행위 등 하천수관리 현황자료를 조사 정리하였다. 현황 자료를 토대로 행정구역(시 도)별, 수계별, 용도별, 허가량별, 월별 분석을 수행하고 그 특성을 파악하였다. 그리고 일시적인 하천수사용은 상기 분석 이외에 하천등급별, 공사종별 분석을 수행하였다. 2009년 총 152건(반려, 취소 등을 제외한 행위는 총 131건 : 국가하천 43건, 지방하천 33건, 일시적인 하천수 55건)의 기본적인 통계분석을 통하여 낙동강유역의 하천수사용 특성을 제시하고, 파악된 하천수사용 특성 결과는 낙동강유역의 물관리정책에 소중한 기초자료로 활용될 것으로 판단된다.

  • PDF

Hydrolysis of Cellulose by Immobilized Cellulase in a Packed Bed Reactor (충진층 반응기에서 고정화 cellulase에 의한 셀룰로스 가수 분해)

  • Kang, Byung Chul;Lee, Jong Baek
    • Journal of Life Science
    • /
    • v.23 no.11
    • /
    • pp.1365-1370
    • /
    • 2013
  • Immobilized cellulase on weak ion exchange resin showed a typical Langmuir adsorption isotherm. Immobilized cellulase had better stability with respect to pH and temperature than free cellulase. Kinetics of thermal inactivation on free and immobilized cellulase followed first order rate, and immobilized cellulase had a longer half-life than free cellulase. The initial rate method was used to characterize the kinetic parameters of free and immobilized enzyme. The Michaelis-Menten constant $K_m$ was higher for the immobilized enzyme than it was for the free enzyme. The effect of the recirculation rate on cellulose degradation was studied in a recycling packed-bed reactor. In a continuous packed-bed reactor, the increasing flow rate of cellulose decreased the conversion efficiency of cellulose at different input lactose concentrations. Continuous operation for five days was conducted to investigate the stability of long term operation. The retained activity of the immobilized enzymes was 48% after seven days of operation.

Water Saving Irrigation Manual of Autumn Chinese Cabbage (가을배추의 물 절약형 관개기준 설정)

  • Jung, Pil-Kyun;Eom, Ki-Cheol;Son, Yeon-Ku;Koh, Mun-Hwan;Kim, Sang-Hee;Park, So-Hyun;Yoo, Sung-Yung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.679-687
    • /
    • 2011
  • The water management of crop is different according to the area as well as climate condition and growth stage, however it is the most important and difficult problems for the farmers. The optimum irrigation manual those irrigation interval and amount of irrigation as water saving, are developed based on the lysimeter experiments carried out by the RDA for 11 years about PET (Potential Evapo-Transpiration), crop coefficient (Kc). The average PET (Potential Evapo-Transpiration) during 30 years of 45 regions for the autumn chinese cabbage cultivation was a $2.17mm\;day^{-1}$.

Water Saving Irrigation Manual of Spring Chinese Cabbage (봄배추의 물 절약형 관개기준 설정)

  • Eom, Ki-Cheol;Jung, Pil-Kyun;Koh, Mun-Hwan;Kim, Sang-Hee;Yoo, Sung-Yung;Park, So-Hyun;Hur, Seung-Oh;Ha, Sang-Keun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.812-822
    • /
    • 2010
  • Water management is the most important and difficult problems in crop cultivation. The farmers are doing irrigation, those when to irrigate and how much to irrigate, depending on their experiences. The irrigation manual as water saving is possible, those irrigation interval and amount of irrigation, are developed based on the lysimeter experiments carried out by the RDA for 11 years about potential evapotranspiration, crop coefficient. The manual can be used with easy to the farmer without soil sampling and any kinds of sensors measuring soil water status.

The Effect of External PEEP on Work of Breathing in Patients with Auto-PEEP (Auto-PEEP이 존재하는 환자에서 호흡 일에 대한 External PEEP의 효과)

  • Chin, Jae-Yong;Lim, Chae-Man;Koh, Youn-Suck;Park, Pyung-Whan;Choi, Jong-Moo;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.201-209
    • /
    • 1996
  • Background : Auto-PEEP which develops when expiratory lung emptying is not finished until the beginning of next inspiration is frequently found in patients on mechanical ventilation. Its presence imposes increased risk of barotrauma and hypotension, as well as increased work of breathing (WOB) by adding inspiratory threshold load and/or adversely affecting to inspiratory trigger sensitivity. The aim of this study is to evaluate the relationship of auto-PEEP with WOB and to evaluate the effect of PEEP applied by ventilator (external PEEP) on WOB in patients with auto-PEEP. Method : 15 patients, who required mechanical ventilation for management of acute respiratory failure, were studied. First, the differences in WOB and other indices of respiratory mechanics were examined between 7 patients with auto-PEEP and 8 patients without auto-PEEP. Then, we applied the 3 cm $H_2O$ of external PEEP to patients with auto-PEEP and evaluated its effects on lung mechanics as well as WOB. Indices of respiratory mechanics including tidal volume ($V_T$), repiratory rate, minute ventilation ($V_E$), peak inspiratory flow rate (PIFR), peak expiratory flow rate (PEFR), peak inspiratory pressure (PIP), $T_I/T_{TOT}$, auto-PEEP, dynamic compliance of lung (Cdyn), expiratory airway resistance (RAWe), mean airway resistance (RAWm), $p_{0.1}$, work of breathing performed by patient (WOB), and pressure-time product (PTP) were obtained by CP-100 Pulmonary Monitor (Bicore, USA). The values were expressed as mean $\pm$ SEM (standard error of mean). Results : 1) Comparison of WOB and other indices of respiratory mechanics in patients with and without auto-PEEP : There was significant increase in WOB ($l.71{\pm}0.24$ vs $0.50{\pm}0.19\;J/L$, p=0.007), PTP ($317{\pm}70$ vs $98{\pm}36\;cm$ $H_2O{\cdot}sec/min$, p=0.023), RAWe ($35.6{\pm}5.7$ vs $18.2{\pm}2.3\;cm$ H2O/L/sec, p=0.023), RAWm ($28.8{\pm}2.5$ vs $11.9{\pm}2.0cm$ H2O/L/sec, p=0.001) and $P_{0.1}$ ($6.2{\pm}1.0$ vs 2.9+0.6 cm H2O, p=0.021) in patients with auto-PEEP compared to patients without auto-PEEP. The differences of other indices including $V_T$, PEFR, $V_E$ and $T_I/T_{TOT}$ showed no significance. 2) Effect of 3 cm $H_2O$ external PEEP on respiratory mechanics in patients with auto-PEEP : When 3 cm $H_2O$ of external PEEP was applied, there were significant decrease in WOB ($1.71{\pm}0.24$ vs $1.20{\pm}0.21\;J/L$, p=0.021) and PTP ($317{\pm}70$ vs $231{\pm}55\;cm$ $H_2O{\cdot}sec/min$, p=0.038). RAWm showed a tendency to decrease ($28.8{\pm}2.5$ vs $23.9{\pm}2.1\;cm$ $H_2O$, p=0.051). But PIP was increased with application of 3 cm $H_2O$ of external PEEP ($16{\pm}2$ vs $22{\pm}3\;cm$ $H_2O$, p=0.008). $V_T$, $V_E$, PEFR, $T_I/T_{TOT}$ and Cdyn did not change significantly. Conclusion : The presence of auto-PEEP in mechanically ventilated patients was accompanied with increased WOB performed by patient, and this WOB was decreased by 3 cm $H_2O$ of externally applied PEEP. But, with 3 cm $H_2O$ of external PEEP, increased PIP was noted, implying the importance of close monitoring of the airway pressure during application of external PEEP.

  • PDF

Assessment of future climate and land use changes impact on hydrologic behavior in Anseong-cheon Gongdo urban-growing watershed (미래 기후변화와 토지이용변화가 안성천 공도 도시성장 유역의 수문에 미치는 영향 평가)

  • Kim, Da Rae;Lee, Yong Gwan;Lee, Ji Wan;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.2
    • /
    • pp.141-150
    • /
    • 2018
  • The purpose of this study is to evaluate the future hydrologic behavior affected by the potential climate and land use changes in upstream of Anseong-cheon watershed ($366.5km^2$) using SWAT. The HadGEM3-RA RCP 4.5 and 8.5 scenarios were used for 2030s (2020-2039) and 2050s (2040-2059) periods as the future climate change scenario. It was shown that maximum changes of precipitation ranged from -5.7% in 2030s to +18.5% in 2050s for RCP 4.5 scenarios and the temperature increased up to $1.8^{\circ}C$ and $2.6^{\circ}C$ in 2030s RCP 4.5 and 2050s 8.5 scenarios respectively based on baseline (1976-2005) period. The future land uses were predicted using the CLUE-s model by establishing logistic regression equation. The 2050 urban area were predicted to increase of 58.6% (29.0 to $46.0km^2$). The SWAT was calibrated and verified using 14 years (2002-2015) of daily streamflow with 0.86 and 0.76 Nash-Sutcliffe model efficiency (NSE) for stream flow (Q) and low flow 1/Q respectively focusing on 2 drought years (2014-2015) calibration. For future climate change only, the stream discharge showed maximum decrease of 24.2% in 2030s RCP 4.5 and turned to maximum increase of 10.9% in 2050s RCP 4.5 scenario compared with the baseline period stream discharge of 601.0 mm by the precipitation variation and gradual temperature increase. While considering both future climate and land use change, the stream discharge showed maximum decrease of 14.9% in 2030s RCP 4.5 and maximum increase of 19.5% in 2050s RCP 4.5 scenario by the urban growth and the related land use changes. The results supported that the future land use factor might be considered especially for having high potential urban growth within a watershed in the future climate change assessment.

Recovery of $SF_6$ gas from Gaseous Mixture ($SF_6/N_2/O_2/CF_4$) through Polymeric Membranes (고분자 분리막을 이용한 혼합가스($SF_6/N_2/O_2/CF_4$)로부터 $SF_6$의 회수)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Choi, Ho-Sang;Lee, Sang-Hyup
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • During the maintenance, repair and replacement process of circuit breaker, $SF_6$ reacted with input air in arc discharge, which led to the production of by-product gases (eg, $N_2$, $O_2$, $CF_4$, $SO_2$, $H_2O$, HF, $SOF_2$, $CuF_2$, $WO_3$). Among these various by-product gases, $N_2$, $O_2$, $CF_4$ is major component. Therefore, the effective separation process is necessary to recycle the $SF_6$ gas from the mixture gas containing $N_2$, $O_2$, $CF_4$. In this study, the membrane separation process was applied to recycle the $SF_6$ gas from the mixture gas containing $N_2$, $O_2$, $CF_4$. The concentration of $SF_6$ gas in gas produced from the electric power industry is over than 90 vol%. Therefore, we made the simulated gas containing $N_2$, $O_2$, $CF_4$, $SF_6$ which the concentration of $SF_6$ gas is minimum 90 vol%. From the results of membrane separation process of $SF_6$ gas from $N_2$, $O_2$, $CF_4$ $SF_6$ mixture gases, PSF membrane shown the highest recovery efficiency 92.7%, in $25^{\circ}C$ and 150 cc/min of retentate flow rate. On the other hand, PC membrane shown the highest recovery efficiency 74.8%, in $45^{\circ}C$ and 150 cc/min of retentate flow rate. Also, the highest rejection rate of $N_2$, $O_2$, $CF_4$ is 80, 74 and 58.9% seperately in the same operation condition of highest recovery efficiency. From the results, we supposed the membrane separation process as the effective $SF_6$ separation and recycle process from the mixture gas containing $N_2$, $O_2$, $CF_4$, $SF_6$.