• Title/Summary/Keyword: 6-Pole

Search Result 449, Processing Time 0.043 seconds

Design of a broadband(2㎓-5.8㎓) FET Switch Using Impedance Transformation Network (임피던스 변환회로를 이용한 광대역(2㎓-5.8㎓) FET 스위치 설계)

  • 노희정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.155-159
    • /
    • 2004
  • This paper describes the design and the simulation of a single pole double throw(SPDT) FET switch for wireless LAN(IEEE802.11a & IEEE802.11b) applications using drain impedance transformation network with Microstrip transmission line. At the receiving path insertion losses were from 0.8(㏈) to 1.462(㏈) between 2(㎓) and 4(㎓), from l.26(㏈) to 2.3(㏈) between 4.7(㎓) and 6.7(㎓) and the isolations were under 30(㏈) between 2(㎓) and 6.7(㎓). At the transmitting path insertion loss were from 1.18(㏈) to 2.87(㏈) between 2(㎓) and 4(㎓) from 0.625(㏈) to 1.2(㏈) between 4.7(㎓) and 6.7(㎓) and the isolations were under 30(㏈) between 2(㎓) and 6.7(㎓).

Analysis of outlet edge cogging force at the Permanent Magnet Linear Synchronous Motor According to Difference of the Winding Method (권선방식 차이에 따른 영구자석 선형 동기 전동기의 단부 코깅력 해석)

  • Kim, Yong-Jae;Kim, Sung-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.889-895
    • /
    • 2011
  • PMLSM is structurally simple and it have a lot of merits such high speed, high thrust force etc., but cogging force by slot-teeth structure of armature and cogging force by outlet edge effect occurs. This is the cause of thrust force ripple and generate the noise and vibration. Therefore, in this paper we proposed installation of an auxiliary pole to mover of the PMLSM in order to decrease cogging force by the outlet edge which came necessarily into being discontinuous arrangement of the armature. Also, outlet edge cogging force designed a form of the auxiliary pole which the minimum became, and we compared a outlet edge cogging force characteristic along a winding method of an armature as we used 2-D of finite element analysis.

Optimal Design of Ferromagnetic Pole Pieces for Transmission Torque Ripple Reduction in a Magnetic-Geared Machine

  • Kim, Sung-Jin;Park, Eui-Jong;Kim, Yong-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1628-1633
    • /
    • 2016
  • This paper derives an effective shape of the ferromagnetic pole pieces (low-speed rotor) for the reduction of transmission torque ripple in a magnetic-geared machine based on a Box-Behnken design (BBD). In particular, using a non-linear finite element method (FEM) based on 2-D numerical analysis, we conduct a numerical investigation and analysis between independent variables (selected by the BBD) and reaction variables. In addition, we derive a regression equation for reaction variables according to the independent variables by using multiple regression analysis and analysis of variance (ANOVA). We assess the validity of the optimized design by comparing characteristics of the optimized model derived from a response surface analysis and an initial model.

Small-Signal Analysis of a Differential Two-Stage Folded-Cascode CMOS Op Amp

  • Yu, Sang Dae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.768-776
    • /
    • 2014
  • Using a simplified high-frequency small-signal equivalent circuit model for BSIM3 MOSFET, the fully differential two-stage folded-cascode CMOS operational amplifier is analyzed to obtain its small-signal voltage transfer function. As a result, the expressions for dc gain, five zero frequencies, five pole frequencies, unity-gain frequency, and phase margin are derived for op amp design using design equations. Then the analysis result is verified through the comparison with Spice simulations of both a high speed op amp and a low power op amp designed for the $0.13{\mu}m$ CMOS process.

Optimization of Bumper Beam Section of Crashworthiness (충돌성능을 고려한 승용차 범퍼빔 단면의 최적화)

  • Kang, S.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.276-284
    • /
    • 1998
  • Optimum design of bumper beam is investigated using nonlinear CAE structural analysis techniques.In order to minimize its weight, while enhancing structural performances, bumper beam structural analyses were carried out to produce optimum section. Model is composed of bumper beam and stay. First, considering FMVSS safety standard, static strength and energy absorbing capability were estimated for several competitive bumpers through pendulum static analysis, and most promising section was chosen. Next, to ensure dynamic crashworthinesss performance for center pole impact was evaluated for the bumper beam with chosen section through pendulum static analysis, referring to DHS bumper dynamic impact standard. Finally, 2.5 mph bumper beam was designed and its structural performance was estimated. Through this investigation, an optimized bumper beam section with less weight of 20% while maintaining almost equal carshworthiness, compared with a conventional bumper beam section which proved its impact crashworthiness by experiments, was developed.

  • PDF

Corrosion and Wear Properties of Cold Rolled 0.087% Gd-Lean Duplex Strainless Steels for Neutron Absorbing Material (중성자 흡수소재용 냉간 압연된 Gd-저합금 이상 스테인레스 강의 부식 및 마모성)

  • Baek, Yeol;Choe, Yong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.123-123
    • /
    • 2015
  • 0.087 wt.% Gd-lean duplex stainless steels were inert arc-melted and cast in a mold. The micro-hardnesses of the rolling, transverse, short transverse directions were 258.5, 292.3, 314.7 HV, respectively. The 33% cold rolled specimen had the crystallographic texture that mainly (100) pole was concentrated to normal direction and (110) pole was concentrated in the center of normal and rolling directions. The corrosion potential and corrosion rate in artificial sea water were in the range of $105.6-221.6mV_{SHE}$, $0.59-1.06mA/cm^2$, respectively. The friction coefficient and wear loss of the 0.087 wt.% Gd-lean duplex stainless steels in artificial sea water were about 67% and 65% lower than in air, whereas, the wear efficiency was 22% higher. The corrosion and wear behaviors of the 0.087 wt.% Gd-lean duplex stainless steels significantly depended on the gadolinium phases.

  • PDF

An Image-Based Remote Snow Height Measurement System using a USN (이미지 및 USN 기반 원격 적설량 측정 시스템)

  • Lee, Hyung-Bong;Moon, Jung-Ho;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.2
    • /
    • pp.76-85
    • /
    • 2011
  • In conventional methods for measuring snow height, a graduated pole is installed on ground in an area of interest and the snow height is manually read from the pole. Recently, automated snow height measurement systems have been introduced to improve the conventional methods. The automated measurement systems, however, are quite expensive since they use the reflection of ultrasonic waves or laser beams. In addition, it is not easy to move the location of the automated measure systems. This paper proposes a snow height measurement system equipped with image sensors and wireless communication capability via a USN and the Internet. The proposed system has a resolution of 5 cm and easy to deploy without difficulties, which can be usefully used to monitor unforseen local snowfalls.

A Study on Characteristics of Vegetation Distribution according to Revetment Techniques of Riverbank in Han River, Korea (한강 하천제방 호안공법에 따른 식생분포 특성 연구)

  • Kim, Won-Sik;Kwak, Jeong-In;Lee, Kyong-Jae;Han, Bong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.1
    • /
    • pp.17-30
    • /
    • 2011
  • This study has analyzed the vegetation composition in the areas using different slope revetment techniques of riverbanks, in a way to improve the vegetation induction in the future considering the ecological aspects of the induction in Garaeyoul Village, Gangdong-gu, Seoul. The result of the vegetation distribution in each different slope revetment technique was analyzed, that the naturalized herb was dominant in the pole block accounting for 70.7%, while native herb was dominant in the lawn block occupying 48.5% and in the crib block occupying 55.7%. The vegetation coverage measured by different slope revetment techniques was highest in the crib block(average 97.5%), followed by the lawn block(average 95.3%) and pole block(average 27.9%). The vegetation base area was the most wide in the crib block and the most narrowest in the pole block. The result of community analysis in areas using different slope revetment techniques, dry herbs and vine herbs were dominated and the coverage was very poor in the pole block. In the lawn block, the barb was fragmented into narrow areas due to the blocks, which prevented the creation of large-scale plant communities. In the crib block, Miscanthus sacchariflorus, Fescue arundinacea and Aster pilosus, which also consisted of large-scale communities. Average dry weight was also measured by each slope revetment technique. The weight was heaviest in the crib block with $187.63g/m^2$, followed by the lawn block($137.65g/m^2$) and pole block($6.75g/m^2$). The soil moisture contents in the crib block and lawn block was 16.3% and 15.2%, respectively, while that of the pole block was 4.7%, which revealed the highly dry condition of the pole block soil. The analysis result of soil chemical property showed that there was little difference in soil texture, soile acidity(pH), and exchangeable ion content, however, the soil organic matter(OM) content and available $P_2O_5$ were highest in the pole block. In the future, in order to induce more vegetation into river banks and walls, a proper construction method should be applied so that the vegetation area can be expanded as much as possible, considering the safety of the banks.

A Study of Texture Through the Depth of Core for BSCCO Superconductor Tape with Pole Figure Analysis (BSCCO 선재에서 극점도를 통한 초전도심의 깊이에 따른 집합조직 연구)

  • 지봉기;주진호;나완수;류경우;박노진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.6
    • /
    • pp.499-504
    • /
    • 2001
  • We evaluated the degree of texture through depth of the superconductor core of Bi-Sr-Ca-Cu-O(BSCCO) superconductor tape. The degree of texture was characterized by pole figure analysis indicating that the degree of texture varied significantly with depth of the superconductor core. It was observed that the degree of texture was higher near the interface than inside the superconductor core. Specifically, as getting near to the center from the sheath/core interface, the orientation of BSCCO became dispersed from normal direction(ND) which, in turn, resulted in the degradation of <001>-fiber texture. In addition, the <001> texture was non-uniform an, better texture was developed along rolling direction(RD), compared to transverse direction(TD). Microstructural investigation showed that grain alignment was locally degraded by the existence of second phases. I was observed that larger grain size and better texturing were developed near the relatively straight interface compared to those inside the superconducting core. Based on our study, the region near the interface is thought to carry significant current compared to that inside the core.

  • PDF

Development of Diagnosis Device for Pole and Pad Transformer using Wireless Data Communication (무선 데이터 통신을 이용한 주상 및 지상 변압기 진단 장치 개발)

  • 윤용한;민경래;최도혁;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.85-92
    • /
    • 2000
  • This paper has developed the system that can monitor the distribution transformers(pole and pad) using simplified deterioration detecting sensor in oil and wireless data communication. This system is made up by deterioration detecting sensor, oil level measuring system, deterioration measuring system and communication unit. To prove the usefulness of the system, the paper compared and analyzed the system with the existed system, and after studying the correlation of the both, the result proved goodness of the new system. The proposed monitoring system, when it is used on the pole and pad transformer, would make the reliable diagnoses possible with less rate.

  • PDF