• 제목/요약/키워드: 6-PFM

검색결과 45건 처리시간 0.03초

6-Parametric factor model with long short-term memory

  • Choi, Janghoon
    • Communications for Statistical Applications and Methods
    • /
    • 제28권5호
    • /
    • pp.521-536
    • /
    • 2021
  • As life expectancies increase continuously over the world, the accuracy of forecasting mortality is more and more important to maintain social systems in the aging era. Currently, the most popular model used is the Lee-Carter model but various studies have been conducted to improve this model with one of them being 6-parametric factor model (6-PFM) which is introduced in this paper. To this new model, long short-term memory (LSTM) and regularized LSTM are applied in addition to vector autoregression (VAR), which is a traditional time-series method. Forecasting accuracies of several models, including the LC model, 4-PFM, 5-PFM, and 3 6-PFM's, are compared by using the U.S. and Korea life-tables. The results show that 6-PFM forecasts better than the other models (LC model, 4-PFM, and 5-PFM). Among the three 6-PFMs studied, regularized LSTM performs better than the other two methods for most of the tests.

PWM/PFM Dual Mode SMPS Controller IC for Active Forward Clamp and LLC Resonant Converters

  • Cheon, Jeong-In;Ha, Chang-Woo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권2호
    • /
    • pp.94-97
    • /
    • 2007
  • The desin and implementation of a CMOS analog integrated circuit that provides dual-mode modulations, PWM for active clamp reset converter and PFM for LLC resonant converter, is described. The proposed controller is capable of implementing programmable soft start and current-mode control with compensating ramp for PWM and frequency shifting soft start for PFM. Also it provides delay time for both modes. PWM mode is implemented by active clamp reset converter and PFM mode is implemented by LLC resonant convereter, respectively. The chip is fabricated using the 0.6um high voltage CMOS process.

자연치와 도재관에 대한 색조선택의 동일성 (Shade Matching Identification of in Vivo Natural Teeth and Porcelain-Fused-to-Metal Crowns)

  • 조홍규
    • 대한치과기공학회지
    • /
    • 제29권1호
    • /
    • pp.35-48
    • /
    • 2007
  • The purpose of this study was to evaluate shade selection using conventional visual assessment in vivo natural teeth and porcelain-fused-to-metal (PFM) crown. Maxillary central incisors, lateral incisors and canines of one hundred twenty four college women were used as vivo natural teeth. Fifty one PFM crown for maxillary central incisor fabricated by dental laboratory were used as experimental materials. Using Vitapan Classical Shade Guides, shade selection of natural teeth was measured by each college woman and shade selection of PFM crown was measured by three ceramists with more than ten years career. Both natural teeth and PFM crown shade selection were measured through Shade Eye-Ex. From the shade selection comparing, following results were obtained. The results were as follows: 1. The shade matching identification of natural teeth between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 27.4% in maxillary central incisor, 13.7% in lateral incisor and 18.5% in canine. 2. Among the shade selection of PFM crown by three ceramists, the shade evaluation of three ceramists were same only in ten cases. In twenty case, those of two ceramists were same. 3. The shade matching identification of PFM crown between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 38.6% in average. These results suggest that the shade selection using conventional visual assessment should be dealt with care in clinic and need a credible method for shade matching color.

  • PDF

가압열충격에 의한 원자로 압력용기의 파손확률에 미치는 해석변수의 영향 (The Effect of Analysis Variables on the Failure Probability of the Reactor Pressure Vessel by Pressurized Thermal Shock)

  • 장창희;정명조;강석철;최영환
    • 대한기계학회논문집A
    • /
    • 제28권6호
    • /
    • pp.693-700
    • /
    • 2004
  • The probabilistic fracture mechanics(PFM) is a useful analytical tool to assess the integrity of reactor pressure vessel(RPV) at the event of pressurized thermal shock(PTS). In PFM, the probabilities of flaw initiation and propagation are estimated by comparing the applied stress intensity factor with the fracture toughness calculated by the simulation of various stochastic variables. It is known that the results of PFM analyses are dependent on the choice of the stochastic parameters and assumptions. Of the various variables and assumptions, we investigated the effects of the RT$_{NDT}$ shift equations, fracture toughness curves, and flaw distributions on the PFM results for the three PTS transients. The results showed that the combined effects of the RT$_{NDT}$ shift equations and fracture toughness curves are complicated and dependent on the characteristics of the transients, the chemistry of the materials, the fast neutron fluence, and so on.

우유의 HACCP 시스템에서 Predictive Food Microbiology Model 이용 (Application of Predictive Food Microbiology Model in HACCP System of Milk)

  • 박경진;김창남;노우섭;홍종해;천석조
    • 한국식품위생안전성학회지
    • /
    • 제16권2호
    • /
    • pp.103-110
    • /
    • 2001
  • 예측식품미생물학(PFM)은 1980년대 후반 이후 식품미생물학 분야에서 새롭게 발생한 신학문 분야이다. PFM은 특별한 환경적 요인에 따른 미생물 특히, 병원성미생물의 반응(사멸과 생존)을 예측하기 위하여 수학적인 모델을 이용한 것이다. 현재까지 개발된 PFM모델중 완전한 것은 없지만, 어떤 특정 조건하에서는 신속하고 객관적으로 미생물의 반응을 예측하는데 이용될 수 있다는 장점 때문에, HACCP시스템, Risk Assessment 등에서 응용 가능성이 커지고 있다. 본 연구는 PFM 모델중 PMPwin5.1을 이용하여, 우유 저장에 대한 HACCP시스템 중 미생물학적 위해요소 분석, CCP 및 CL설정에 대한 방법론적 예를 제시하였다. 모델에 대한 초기조건으로 우유와 동일한 물리화학적 조건인 pH 6.7, Aw 0.993, NaCl 1.3%을 고정변수로 하고, 저장온도(4~15$^{\circ}C$)를 변이변수로 선정하여, 온도에 따른 주요 병원성미생물의 generation time, lag phase duration, infective dose에 도달하는데 걸리는 시간을 산출하였다. 이 결과를 바탕으로 온도의 변화에 따른 각 병원성미생물의 성장을 안전정도에 따라 “안전온도범위(Safe temperature zone)”, “주의온도범위(Caution temperature zone)”, “위험온도범위(Danger temperatue zone)”로 분류하였으며, 이들 분류는 우유의 유통기간인 5일을 기준으로 각 병원성미생물의 lag phase duration, infective dose에 도달하는 시간에 따라 결정하였다. 이러한 결과는 우유의 HACCP시스템에 있어, 위해요인 분석시 위해요인의 분류 및 위해요소간의 위해 정도의 우선순위 부여에 보조적인 수단으로 이용될 수 있다. 또한 유통.저장단계에서 병원성미생물의 상징에 대한 온도수준을 나타내므로, 이 단계를 CCP로 설정할 수 있고, CCP에 대한 CL은 주위온도범위내에서 설정할 수 있다. 그리고 허용수준에 대한 온도의 범위를 제시하므로 모니터링이나 검증에서도 이용할 수 있다.

  • PDF

Effect of core design on fracture resistance of zirconia-lithium disilicate anterior bilayered crowns

  • Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.181-188
    • /
    • 2020
  • PURPOSE. The effect of core design on the fracture resistance of zirconia-lithium disilicate (LS2) bilayered crowns for anterior teeth is evaluated by comparing with that of metal-ceramic crowns. MATERIALS AND METHODS. Forty customized titanium abutments for maxillary central incisor were prepared. Each group of 10 units was constructed using the same veneer form of designs A and B, which covered labial surface to approximately one third of the incisal and cervical palatal surface, respectively. LS2 pressed-on-zirconia (POZ) and porcelain-fused-to-metal (PFM) crowns were divided into "POZ_A," "POZ_B," "PFM_A," and "PFM_B" groups, and 6000 thermal cycles (5/55 ℃) were performed after 24 h storage in distilled water at 37 ℃. All specimens were prepared using a single type of self-adhesive resin cement. The fracture resistance was measured using a universal testing machine. Failure mode and elemental analyses of the bonding interface were performed. The data were analyzed using Welch's t-test and the Games-Howell exact test. RESULTS. The PFM_B (1376. 8 ± 93.3 N) group demonstrated significantly higher fracture strength than the PFM_A (915.8 ± 206.3 N) and POZ_B (963.8 ± 316.2 N) groups (P<.05). There was no statistically significant difference in fracture resistance between the POZ_A (1184.4 ± 319.6 N) and POZ_B groups (P>.05). Regardless of the design differences of the zirconia cores, fractures involving cores occurred in all specimens of the POZ groups. CONCLUSION. The bilayered anterior POZ crowns showed different fracture resistance and fracture pattern according to the core design compared to PFM.

과학기술위성 2호 준비행모델 환경시험 결과 (STSAT-2 PFM Environmental Test Result)

  • 이승헌;박종오;심은섭;이승우;서정기;장태성;이상현;김성현
    • 항공우주기술
    • /
    • 제6권1호
    • /
    • pp.55-63
    • /
    • 2007
  • 과학기술위성 2호는 국내에서 최초로 개발되는 소형위성발사체(KSLV-1)에 의하여 국내 발사장(나로 우주센터)에서 발사될 위성이다. 2002년 개발을 시작하여 엔지니어링모델(EM), 준비행모델(PFM), 비행모델(FM)을 개발 완료하였다. 위성의 기능을 점검하기 위해 종합적인 전기/전자 기능시험과 우주환경시험, 발사환경시험을 수행한다. 본 논문은 성공적으로 수행한 과학기술위성 2호 준비행모델의 우주환경시험과 발사환경시험에 대한 분석과 그 결과를 보고한다.

  • PDF

The Development and Evaluation of an Incontinence Intervention Program for the Elderly Women at Elderly Welfare Center

  • Kim Jeungim
    • 대한간호학회지
    • /
    • 제34권8호
    • /
    • pp.1427-1433
    • /
    • 2004
  • Purpose. The elderly with UI experienced urine leakage for a long time. The prevalence of UI has increased and it makes costly. Particularly, the elderly were reluctant to visit a hospital or a clinic for the reasons of modesty and poverty. To solve this problem, incontinence intervention programs should be provided at the elderly welfare center. The purpose of this research was to develop Incontinence Intervention Program for the Elderly Women (IIPE) and evaluate in its effect. Methods. The study design was quasi-experimental with pre and post-test. The study was performed for ten weeks at one elderly welfare center, Seoul, Korea. The subjects were gathered through an official announcement and informed consent was obtained. IIPE, in this study, was consisted of diagnosis, education, exercise and evaluation. The study variables were PFM exercise adherence, pelvic muscle strength, Continence self-efficacy, geriatric depression and incontinence stress. The effects of the IIPE on PFM exercise adherence, pelvic muscle strength, Continence self-efficacy, geriatric depression and incontinence stress were also evaluated. Results. The mean age of the subjects was 75.2 years. The average attendance was 6.2 times. The IIPE improved PFM exercise adherence, intra-vaginal contraction power and CSE significantly. But it was not significant in incontinence stress and geriatric depression. Other important results were that the two-finger test and urine stream interruption were more useful for elderly women with rigid vaginas in teaching and evaluating. Conclusion. The Findings suggest that IIPE is effective to the community-residing elderly. Further investigation is needed on a long-term basis with control group.

지르코니아, 유리침투알루미나 및 PFM 전부관 시스템의 파절 경향에 관한 비교연구 (A comparative study on the fracture behavior of zironia, glass infiltrated alumina and PFM full crown system)

  • 이상혁;안진수;김명호;임범순
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.235-242
    • /
    • 2012
  • 연구 목적: 본 연구는 지르코니아, 유리침투알루미나 및 금속도재소부용치관의 파절강도를 비교하고자 하였다. 연구 재료 및 방법: 지르코니아, 유리침투알루미나 및 금속도재소부용합금으로 각각 15개의 치관을 제작한 후, 제작된 치관을 장축에 $30^{\circ}$ 경사지게 제작된 지그에 장착하여 만능시험기로 파절강도를 측정하였으며, 전단결합강도 시험을 위하여 지르코니아, 유리침투알루미나 및 금속도재소부용합금을 $5.5({\phi}){\times}2.5mm$ 크기로 제작하고 포세린 분말을 $3.5({\phi}){\times}2.5mm$ 크기로 축성한 후 제조사의 설명서에 따라 전기로(Ceramco 7, Dentsply, USA)에서 소결하여 총10개의 시편을 제작하였다. 결과: 전부관 형태로 제작한 시편의 파절강도는 금속-도재 시스템이 $569.1{\pm}61.8N$, 알루미나-도재 시스템이 $551.0{\pm}76.5N$ 및 지르코니아-도재 시스템이 $588.3{\pm}49.6N$으로 측정되었으며, 각 실험군간 유의한 차이는 없었다(P>.05). 전단결합강도는 금속-도재 시스템이 $38.9{\pm}5.0MPa$, 알루미나-도재 시스템이 $39.4{\pm}5.1MPa$, 지르코니아-도재 시스템이 $25.5{\pm}5.6MPa$로 지르코니아-도재 시스템이 다른 두 시스템 보다 유의하게 낮은 값을 보였다(P<.05). 금속-도재 시스템, 알루미나-도재 시스템 및 지르코니아-도재 시스템의 각 결합계면을 SEM/EDS로 분석한 결과 각 시스템에서 상이한 결합 양상이 관찰되었다. 결론: 본 연구 결과 지르코니아-도재 시스템의 파절강도가 제일 높았으며, 금속-도재 시스템, 알루미나-도재 시스템 순서로 나타났으며, 전단결합강도는 알루미나-도재 시스템이 제일 높았고 금속-도재 시스템, 지르코니아-도재 시스템 순서으로 나타났다.

Rapid Dynamic Response Flyback AC-DC Converter Design

  • Chang, Changyuan;Wu, Menglin;He, Luyang;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1627-1633
    • /
    • 2018
  • A constant voltage AC-DC converter based on digital assistant technology is proposed in this paper, which has rapid dynamic response capability. The converter operates in the PFM (Pulse Frequency Modulation) mode. According to the load state, the compensation current produced by the digital compensation module was injected into the CS pin to adjust the switching pulse width dynamically and improve the dynamic response. The control chip is implemented based on NEC $1{\mu}m$ 5V/40V HVCMOS process. A 5V/1.2A prototype has been built to verify the proposed control method. When the load jumps from idle to heavy, the undershoot time is only 7.4ms.