Dosimetric Verifications of the Output Factors in the Small Field Less Than $3cm^2$ Using the Gafchromic EBT2 Films and the Various Detectors (Gafchromic EBT2필름과 다양한 검출기를 이용하여 $3cm^2$ 이하의 소조사면에서 출력비율의 선량검증)

  • Oh, Se An;Yea, Ji Woon;Lee, Rena;Park, Heon Bo;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.218-224
    • /
    • 2014
  • The small field dosimetry is very important in modern radiotherapy because it has been frequently used to treat the tumor with high dose hypo-fractionated radiotherapy or high dose single fraction stereotactic radiosurgery (SRS) with small size target. But, the dosimetry of a small field (< $3{\times}3cm^2$) has been great challenges in radiotherapy. Small field dosimetry is difficult because of (a) a lack of lateral electronic equilibrium, (b) steep dose gradients, and (c) partial blocking of the source. The objectives of this study were to measure and verify with the various detectors the output factors in a small field (<3 cm) for the 6 MV photon beams. Output factors were measured using the CC13, CC01, EDGE detector, thermoluminescence dosimeters (TLDs), and Gafchromic EBT2 films at the sizes of field such as $0.5{\times}0.5$, $1{\times}1$, $2{\times}2$, $3{\times}3$, $5{\times}5$, and $10{\times}10cm^2$. The differences in the output factors with the various detectors increased with decreasing field size. Our study demonstrates that the dosimetry for a small photon beam (< $3{\times}3cm^2$) should use CC01 or EDGE detectors with a small active volume. And also, Output factors with the EDGE detectors in a small field (< $3{\times}3cm^2$) coincided well with the Gafchromic EBT2 films.

A Comparison of coincidence between the Light field & the Radiation field using film and BIS (필름과 BIS 영상장치를 이용한 광/방사선조사야 일치성 비교평가)

  • Bang, Dong-Wan;Seok, Jin-Yong;Jeong, Yun-Ju;Choi, Byeong-Don;Park, Jin-Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.33-41
    • /
    • 2004
  • Purpose : Film has been the primary tool in coincidence testing between the light field and the radiation field, which constitutes the quality assurance list of a linear accelerator. But there is a great chance of errors being different among the observer when using film. Thus this study set out to use the BIS(Beam Image System) in addition to film in comparing and evaluating coincidence results between the two fields and in searching for the improvement measures. Materials & Methods : Photon beam of 6 and 15MV was exposed to film and the BIS using a linear accelerator. The light and radiation fields were each $50{\times}50,\;100{\times}100,\;and\;200{\times}200mm^2$. The gantry angle was $0^{\circ}$ when using film and $0^{\circ}\;and\;270^{\circ}$ when using the BIS. The devices adopted to test coincidence between the two fields were a ruler and film scanner when using film. With the BIS, the width of the scanned light and radiation fields was measured for errors with setting the X and Y axis. Results : The visual measurements of the observer with film resulted that the radiation field was bigger than the light field and that their maximum error was 1.9mm. The results were the same with the measurements using the film scanner except for the average error, which was less than 1.9mm. On the contrary, the measurements using the BIS showed that the light field was bigger than the radiation field at the gantry angle of $0^{\circ}\;and\;270^{\circ}$. The maximum error was 0.96mm, and the error range was $<{\pm}2mm$ both in the X and Y axis. The average error of ${\Delta}X$, Y was the smallest in the order of the visual film measurements, film scanner measurements, and BIS measurements Conclusion . This requires a careful measurement for accurate quality assurance since errors are much different according to each observer that tests coincidence between visual fields with film. And an observer needs to use another image device or develop a measuring device of his own if it seems necessary for accurate measurements.

  • PDF

The Significance of VEGF Expression in Stage II Carcinoma of Uterine Cervix Treated with Definitive Radiotherapy (자궁경부암 환자의 근치적 방사선치료 시 VEGF 발현의 임상적 의의)

  • Park Won;Choi Yoon-La;Huh Seung-Jae;Yoon Sang-Min;Park Young-Je;Nam Hee-Rim;Ahn Yong-Chan;Lim Do-Hoon;Park Hee-Chul
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • Purpose: We wanted to determine the clinical characteristics and prognosis according to the VEGF expression in stage II cervical carcinoma patients treated with definitive radiotherapy. Materials and Methods: We enrolled 31 patients who were diagnosed with cervical cancer from 1995 to 2003 at Samsung Medical Center and their paraffin block tissue samples were available for study. The median age of the patients was 65 years. The mean tumor size was 4.1 cm $(range:\;1.2{\sim}8.2cm)$. Seven patients (22.6%) were suspected of having pelvic lymph node metastasis. An external beam irradiation dose of 45-56.4 Gy was administered to the whole pelvis with a 15 MV linear accelerator, and an additional 24 Gy was given to point A by HDR intracavitary brachytherapy. VEGF staining was defined as positive when more than 10% of the tumor cells were stained. The median follow-up duration was 58 months. Results: A positive VEGF expression was observed in 21 patients (67.7%), There was no significant correlation between the VEGF expression and pelvic lymph node metastasis, tumor size and the response of radiotherapy. During follow-up, 7 patients had recurrence. The complete response rate was not significant between the VEGF(-) and VEGF(+) tumors. However, the VEGF(+) tumors showed a significantly higher recurrence rate in comparison with the VEGF(-) tumors (p=0.040), The three year disease-free survival rates were 100% and 66.7%, respectively, for patients with VEGF(-) or VEGF(+) tumor (p=0.047), Conclusion: The VEGF expression was a significant factor for recurrence and disease-free survival. However, the significance of the VEGF expression is still controversial because of the various definitions of VEGF expression and the mismatches of the clinical data in the previous studies.

The Analyses of Treatment Results and Prognostic Factors in Supradiaphragmatic CS I-II Hodgkin's Disease (횡경막상부에 국한된 임상적 병기 1-2기 호지킨병에서 치료 결과와 예후 인자의 분석)

  • Park Won;Suh Chang Ok;Chung Eun Ji;Cho Jae Ho;Chung Hyun Cheol;Kim Joo Hang;Roh Jae Kyung;Hahn Jee Sook;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 1998
  • Purpose : The aim of this retrospective study is to assess the necessity of s1aging laparotomy in the management of supradiaphragmatic CS I-II Hodgkin's disease. Prognostic factors and the usefulness of prognostic factor groups were also analyzed. Materials and Methods : From 1985 to 1995, fifty one Patients who were diagnosed as supradiaphragmatic CS I-II Hodgkin's disease at Yonsei Cancer Center in Seoul, Korea were enrolled in this study Age range was 4 to 67 with median age of 30. The number of patients with each CS IA, II A, and IIB were 16, 25, and 10, respectively. Radiotherapy(RT) was delivered using 4 or 6 MV photon beam to a total dose of 19.5 to 55.6Gy (median dose : 45Gy) with a 1.5 to 1.BGy per fraction. Chemotherapy(CT) was given in 2-12 cycles(median : 6 cycles). Thirty one Patients were treated with RT alone, 4 patients with CT alone and 16 patients with combined chemoradiotherapy. RT volumes varied from involved fields(3), subtotal nodal fields(18) or mantle fields(26). Results : Five-year disease-free survival rate(DFS) was $78.0\%$ and overall survival rate(05) was $87.6\%$. Fifty Patients achieved a complete remission after initial treatment and 8 patients were relapsed. Salvage therapy was given to 7 patients, 1 with RT alone, 4 with CT alone, 2 with RT+CT. Only two patients were successfully salvaged. Feminine gender and large media-stinal adenopathy were significant adverse prognostic factors in the univariate analysis for DFS. The significant adverse prognostic factors of OS were B symptom and clinical stage. When patients were analyzed according to European Organization for Research and Treatment of Cancer(EORTC) prognostic factor groups, the DFS in Patients with very favorable, favorable and unfavorable group was 100, 100 and $55.8\%$(p<0.05), and the 05 in each patients' group was 100, 100 and $75.1\%$(p<0.05), respectively. In very favorable and favorable groups, the DFS and 05 were all $100\%$ by RT alone, but in unfavorable group, RT with CT had a lesser relapse rate than RT alone. The subtotal nodal irradiation had better OFS than mantle RT in patients treated with RT. Conclusion : In present study, the DFS and OS in patients who did not undergo s1aging laparotomy were similar with the results in the literatures of which patients were surgically staged. Therefore, we may suggest that staging laparotomy would not influence the outcome of treatments. In univariate analysis, gender, large mediastinal adenopathy. B symptoms and clinical stage were significant prognostic factors for the survival rate. We confirm the usefulness of EORTC prognostic factor groups which may be a good.

  • PDF

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF

The Role of Primary Radiotherapy for Squamous Cell Carcinoma of the Suprag1ottic Larynx (성문상부 상피세포암에서의 근치적 방사선치료의 역할)

  • Kim, Won-Taek;Kim, Dong-Won;Kwon, Byung-Hyun;Nam, Ji-Ho;Hur, Won-Joo
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.233-243
    • /
    • 2000
  • Purpose : First of all, this study was performed to assess the result of curative radiotherapy and to evaluate different possible prognostic factors for squamous cell carcinoma of the supraglottic larynx treated at the Pusan National University Hospital. The second goal of this study was by comparing our data with those of other study groups, to determine the better treatment policy of supraglottic cancer in future. Methods and Material : Thirty-two patients with squamous cell carcinoma of the supraglottic larynx were treated with radiotherapy at Pusan National University Hospital, from August 1985 to December 1996. Minimum follow-up period was 29 months, Twenty-seven patients (84.4$\%$) were followed up over 5 years. Radiotherapy was delivered with 6 MV photons to the primary laryngeal tumor and regional iymphatics with shrinking field technique. Ail patients received radiotherapy under conventional fractionated schedule (once a day). Median total tumor dose was 70.2 Gy (range, 55.8 to 75.6 Gy) on primary or gross tumor lesion. Thirteen patients had Induction chemotherapy with cisplatln and 5-fluorouracil (1-3 cycles). Patient distribution, according to the different stages, were as follows: stage I, 5/32 (15.6$\%$): stage II, 10/32 (31.3$\%$); stage III, 8/32 (25$\%$): stage IV, 9/32 (28.1$\%$). Results :The 5-year overall survival rate of the whole series (32 patients) was 51.7$\%$. The overall survival rate at 5-years was 80$\%$ in stage I, 66.7$\%$ in stage II, 42.9$\%$ in stage III, 25$\%$ in stage IV (p=0.0958). The S-year local control rates after radiotherapy were as fellows: stage I, 100$\%$; stage II, 60$\%$ stage III, 62.5$\%$; stage IV, 44.4$\%$ (p=0.233). Overall vocal preservation rates was 65.6$\%$, 100% In stage I, 70% in stage II, 62.5$\%$ In stage III, 44.4$\%$ in stage IV (p=0.210). There was no statistical significance in survival and local control rate between neoadjuvant chemotherapy followed by radiotherapy group and radiotherapy alone group. Severe laryngeal edema was found in 2 cases after radiotllerapy, emergent tracheostomy was done. Four patients were died from distant metastsis, . three in lung, one in brain. Double primary tumor was found in 2 cases, one in lung (metachronous), another in thyroid (synchronous). Ulcerative lesions were revealed as unfavorable prognostic factor ( p=0.0215), and radiation dose (more or less than 70.2 Gy) was an important factor on survival (p=0.002). Conclusion : The role of radiotherapy treatment of supraglottic carcinoma is to important factor on survival and to preserve the laryngeal function. Based on our data and other studies, early and moderately advanced supragiottic carcinomas could be successfully treated with either consewative surgery or radiotherapy alone. Both modalities showed similar results in survival and vocal preservation. For the advanced cases, radiotherapy alone is Inadequate for curative aim and surgery combined with radiotherapy should be done in operable patients. When patients refuse operation or want to preserve vocal function, or for the patients with inoperable medical conditions, combined chemoradiotherapy (concurrent) or altered fractionated radiotherapy with or without radiosensitizer should be taken into consideration in future.

  • PDF

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF

Carbon Fiber as Material for Radiation Fixation on Device : A comparative study with acrylic (고정기구 재질로써 탄소 섬유와 아크릴의 방사선량 감쇄 영향 비교)

  • Chie, Eui-Kyu;Park, Jang-Pil;Huh, Soon-Nyung;Hong, Se-Mie;Park, Suk-Won;Kim, In-Ah;Wu, Hong-Gyun;Kim, Jae-Sung;Kang, Wee-Saing;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Radiation absorption parameters of carbon fiber panel were measured in comparison to acrylic panel. $30{\times}30cm$ sized 2mm thick carbon fiber panel and identical sized 6mm thick acrylic panel were placed in tray holder position and 0cm, 5cm, 10cm from surface of phantom. Radiation field size was $10{\times}10cm$. 50MU of 4MV photon was irradiated to the phantom with dose rate of 300MU/min. Source-to-phantom distance was 120cm. Radiation dose was measured with 0.6cc Farmer-type ionization chamber with 1cm build-up. Measurement was repeated thrice and normalization was done to the dose of the open field. Radiation transmission rate of carbon fiber panel is approximately 1% lower than acrylic panel of equivalent thickness. However, considering the strength of the material, transmission rate is higher for carbon fiber panel. Although carbon fiber panel increases the radiation dose when attached to the surface for about 2%, it normalizes the radiation dose to 97-99% of irradiated dose which could have been lowered to as much as 5-7.5% with acrylic panel. As carbon fiber panel is stronger than acrylic panel, radiation fixation device could be made thinner and thus lighter and furthermore, with increased radiation transmission. This in turn makes carbon fiber more ideal material for radiation fixation device over conventionally used acrylic.

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.