• Title/Summary/Keyword: 6 MV

Search Result 870, Processing Time 0.027 seconds

The Results of Hyperfractionated Radiotherapy on Locally Advanced Non-Small Cell Lung Cancer (국소적으로 진행된 비소세포 폐암에 대한 과분할 방사선 치료의 성적)

  • Hur, Won-Joo;Lee, Hyung-Sik;Kim, Jeong-Ki;Choi, Young-Min;Lee, Ho-Jun;Youn-Seon-Min;Kim, Jae-seok;Kim, Hyo-Jin;Woo-Jong-Soo;Choi, Pill-Jo;Lee, Ki-Nam
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.275-282
    • /
    • 1998
  • Purpose : The effect of hyperfractionated radiotherapy on locally advanced non-small lung cancer was studied by a retrospective analysis. Materials & Methods : We analyzed sixty one patients of biopsy-confirmed, IIIA and IIIB non-small cell lung cancer. Using the ECOG performance scale, all the patients were scored less than 2. They were treated by curative hyperfractionated radiotherapy alone from Oct. 1992 to Oct. 1995 at the Department of Radiation Oncology. All the patients received 120cGy b.i.d with more than 6 hours interval between each fraction. The total dose of radiation was reached up to 6400-7080 cGy with a mean dose of 6934 cGy. The results were analyzed retrospectively. Results : The overall survival rate was 53 1$\%$ in 1 year, 9.9$\%$ in 2 years with a median survival time (MST) of 13.9 months. The progression free survival (PFS) rate was 37.0$\%$ in 1 year, 8.9$\%$ in 2 years. Twenty two Patients were classified as complete responders to this treatment and their MST was 19.5 months When this was compared with that of partial responders (MST: 11 7months), it was statistically significant (p=0.0003). Twenty nine patients of stage IIIA showed a better overall survival rate (1yr 63.3$\%$, 2yr 16.8$\%$) than IIIB patients (1yr 43.3$\%$, 2yr 3.6$\%$), which was also statistically significant (p=0.003). Patients with adenocarcinoma showed a better survival rate (1yr 64.3$\%$, 2yr 21.4$\%$) than that of squamous cell counterpart (1yr 49.4$\%$, 2yr 7.4$\%$), although this was not significant statistically (p=0.61). Two patients developed fatal radiation-induced pneumonia right after the completion of the treatment which progressed rapidly and they all died within 2 months. One patient developed radiation-induced fibrosis after 13 months. He refused further treatment and died soon after the development of fibrosis. Conclusion : Among locally advanced NSCLC, hyperfractionated radiotherapy was effective on stage IIIA patients by increasing MST with acceptable toxicities. Acute radiation-induced pneumonia should be carefully monitored and must be avoided during or after this treatment.

  • PDF

Optimization of Total Arc Degree for Stereotactic Radiotherapy by Using Integral Biologically Effective Dose and Irradiated Volume (정위방사선치료 시 적분 생물학적 유효선량 및 방사선조사용적을 이용한 Total Arc Degree의 최적화)

  • Lim Do Hoon;Lee Myung Za;Chun Ha Chung;Kim Dae Yong
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.199-204
    • /
    • 2001
  • Purpoe : To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. Methods and Materials : With Xknife-3 planning system & 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, $100^{\circ},\;200^{\circ},\;300^{\circ},\;400^{\circ}C,\;500^{\circ},\;600^{\circ}$ or total arc degrees, and $30^{\circ}\;or\;45^{\circ}$ or arc intervals were used. After the completion of planning, the plans were compared each other using $V_{50}$ (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. Results : At $30^{\circ}$ of arc interval, the values of $V_{50}$ had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 arc interval, up to $400^{\circ}$ of total arc degree, the values of $ V_{50}$ decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. At $30^{\circ}$ of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At $45^{\circ}$ arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with n and n mm or collimator diameters, up to $400^{\circ}$ or total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. Conclusion : In the stereotactic radiotherapy planning for brain lesions, planning with $400^{\circ}$ of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of $500^{\circ}\;and\;600^{\circ}$ of total arc degrees make the increase of$V_{50}$ and integral biologically effective dose. Therefore stereotactic radiotherapy planning using $400^{\circ}$ of total arc degree can increase the therapeutic ratio and produce the effective outcome in the management of personal and mechanical sources in radiotherapy department.

  • PDF

Adjuvant Postoperative Radiation Therapy for Carcinoma of the Uterine Cervix (자궁경부암의 수술 후 방사선치료)

  • Lee Kyung-Ja;Moon Hye Seong;Kim Seung Cheol;Kim Chong Il;Ahn Jung Ja
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.199-206
    • /
    • 2003
  • Purpose: This study was undertaken to evaluate the efficacy of postoperative radiotherapy, and to investigate the prognostic factors for FIGO stages IB-IIB cervical cancer patients who were treated with simple hysterectomy, or who had high-risk factors following radical hysterectomy and pelvic lymph node dissection. Materials and Methods: Between March 1986 and December 1998, 58 patients, with FIGO stages IB-IIB cervical cancer were included in this study. The indications for postoperative radiation therapy were based on the pathological findings, including lymph node metastasis, positive surgical margin, parametrial extension, lymphovascular invasion, invasion of more than half the cervical stroma, uterine extension and the incidental finding of cervix cancer fellowing simple hysterectomy. All patients received external pelvic radiotherapy, and 5 patients, received an additional intracavitary radiation therapy. The radiation dose from the external beam to the whole pelvis was $40\~50$ Gy. Vagina cuff Irradiation was peformed, after completion of the external beam irradiation, at a low-dose rate of Cs-137, with the total dose of $4488\~4932$ chy (median: 4500 chy) at 5 mm depth from the vagina surface. The median follow-up period was 44 months ($15\~108$ months). Results: The 5-yr actuarial local control rate, distant free survival and disease-free survival rate were $98\%,\;95\%\;and\;94\%$, respectively. A univariate analysis of the clinical and pathological parameters revealed that the clinical stage (p=0.0145), status of vaginal resection margin (p=0.0002) and parametrial extension (p=0.0001) affected the disease-free survival. From a multivariate analysis, only a parametrial extension independently influenced the disease-free survival. Five patients ($9\%$) experienced Grade 2 late treatment-related complications, such as radiation proctitis (1 patient), cystitis (3 patients) and lymphedema of the leg (1 patient). No patient had grade 3 or 4 complications. Conclusion: Our results indicate that postoperative radiation therapy can achieve good local control and survival rates for patients with stages IB-IIB cervical cancer, treated with a simple hysterectomy, as well as for those treated with a radical hysterectomy, and with unfavorable pathological findings. The prognostic factor for disease-free survival was invasion of the parametrium. The prognosic factor identified in this study for treatment failure can be used as a selection criterion for the combined treatment of radiation and che motherapy.

Effect of Radiation Dose for Radiotherapy on Ovarian Follicle Atresia in Rat (치료 방사선량이 쥐의 난포 퇴축에 미치는 영향)

  • Lee, Won-Jeong;Seon, Jong-Ryul;Yoo, Se-Jong;Ahn, Bong-Seon
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.208-212
    • /
    • 2012
  • In previous studies, ovarian follicle in rat has been used a higher radiation dose than that for cancer radiotherapy in clinical practice. The aim of this study was to evaluate the effect of radiation dose used for cancer radiotherapy on ovarian follicle atresia in rat. Mice of 4-week-old female were whole body irradiated with 2 cGy or 2 Gy (Mevatron 67, Siemens, Germany) and sacrificed by cervical dislocation. Ovaries were collected at 24 hours after irradiation to observe the degree of follicular atresia. Ovaries were fixed in neutral formaldehyde solution for 24 hours and embedded with paraffin. Cutted in $5{\mu}m$ thickness with microtome and stained with hematoxylin and eosin (H&E) and TUNEL immunohistochemical stain, and examined histologically under a light microscope. All data were presented as mean ${\pm}SD$, calculating the ratio of normal or atretic follicles to total ovarian follicles. Statistical analysis was performed by the Mann Whitney test using the SPSS ver 19.0. Ratio of atretic to total follicles of 2 Gy group was significantly higher than control or 2 cGy groups (p<0.05). Ratio of normal to total follicles of 2 Gy group was significantly lower than control group in preantral follicle (64.0 vs. 87.7, p=0.027). Ratio of normal to total follicles of 2 cGy group was significantly increased more than control or 2 Gy groups in antral follicle, and there were no significant difference between control and 2 Gy groups (p=0.522). Radiation dose of 2 Gy for cancer radiotherapy have a significant effect on ovarian follicle atresia in rat.

Virus Disease Incidences and Transmission Ecology of Oriental Melons in Seongju Area (성주지역 참외 바이러스병의 발생실태와 전염생태)

  • Park, Seok-Jin;Lee, Joong-Hwan;Nam, Moon;Park, Chung-Youl;Kim, Jeong-Seon;Lee, Joo-Hee;Jun, Eun-Suk;Lee, Jun-Seong;Choi, Hong-Soo;Kim, Jeong-Soo;Moon, Jae-Sun;Kim, Hong-Gi;Lee, Su-Heon
    • Research in Plant Disease
    • /
    • v.17 no.3
    • /
    • pp.342-350
    • /
    • 2011
  • Throughout the years 2008 to 2010, we analyzed approximately two thousand oriental melon samples collected from Seongju, using electron microscopy and testing by RT-PCR using primers specific for eight cucurbit-infecting viruses. Data from RT-PCR indicated that Cucumber green mottle mosaic virus (CGMMV), Watermelon mosaic virus 2 (WMV2) and Zucchini yellow mosaic virus (ZYMV) were present and the other viruses were not detected. Among them, CGMMV and WMV2 were the most prevalent pathogens. CGMMV was thought to infect oriental melon from the early growing season, and reached nearly 100% in the later of growing period. Otherwise, WMV2 emerged from June, several months later compared to CGMMV. CGMMV was detected from all aerial parts of the oriental melon including seeds, but not from the roots of the grafted pumpkin rootstock. Seed of two out of five commercial varieties were shown to be CGMMV positive. Nine varieties of pumpkins used as rootstocks were not infected with CGMMV. When the seedlings of grafted oriental melon were transplanted into pots mixed with the oriental melon debris infected with CGMMV, they were not infected by CGMMV. Cutting of pruning shear and the contact of tendrils contributed 48% and 30% to the transmission of the virus, respectively.

Impact of Computed Tomography Slice Thickness on Intensity Modulated Radiation Therapy Plan (전산화단층촬영 슬라이스 두께가 세기변조방사선치료계획에 미치는 영향)

  • Lee, Seoung-Jun;Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.285-293
    • /
    • 2006
  • $\underline{Purpose}$: This study was to search the optimal slice thickness of computed tomography (CT) in an intensity modulated radiation therapy plan through changing the slice thickness and comparing the change of the calculated absorbed dose with measured absorbed dose. $\underline{Materials\;and\;Methods}$: An intensity modulated radiation therapy plan for a head and neck cancer patient was done, first of all. Then CT with various ranges of slice thickness ($0.125{\sim}1.0\;cm$) for a head and neck anthropomorphic phantom was done and the images were reconstructed. The plan parameters obtained from the plan of the head and neck cancer patient was applied into the reconstructed images of the phantom and then absorbed doses were calculated. Films were inserted into the phantom, and irradiated with 6 MV X-ray with the same beam data obtained from the head and neck cancer patient. Films were then scanned and isodoses were measured with the use of film measurement software and were compared with the calculated isodeses. $\underline{Results}$: As the slice thickness of CT decreased, the volume of the phantom and the maximum absorbed dose increased. As the slice thickness of CT changed from 0.125 to 1.0 cm, the maximum absorbed dose changed ${\sim}5%$. The difference between the measured and calculated volume of the phantom was small ($3.7{\sim}3.8%$) when the slice thickness of CT was 0.25 cm or less. The difference between the measured and calculated dose was small ($0.35{\sim}1.40%$) when the slice thickness of CT was 0.25 cm or less. $\underline{Conclusion}$: Because the difference between the measured and calculated dose in a head and neck phantom was small and the difference between the measured and calculated volume was small when the slice thickness of CT was 0.25 cm or less, we suggest that the slice thickness of CT should be 0.25 cm or less for an optimal intensity modulated radiation therapy plan.

Is Radiotherapy Necessary for Stage 1 Testicular Seminoma? (제1병기 성인 고환 정상피종에 대한 임상적 고찰 및 치료결과 분석)

  • Lee, Jung-Ae;Park, Won;Lim, Do-Hoon;Ahn, Yong-Chan;Huh, Seung-Jae;Yu, Jeong-Il;Choi, Han-Yong;Lee, Hyun-Moo;Cho, Eun-Yoon
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.49-54
    • /
    • 2009
  • Purpose: To report on the clinical outcome of patients with stage I testicular seminoma by postoperative radiotherapy (PORT) or surveillance after radical inguinal orchiectomy. Materials and Methods: This study is a retrospective review of 32 stage I pure seminoma patients treated between 1996 and 2005 at the Samsung Medical Center. Twenty two of the patients were treated by PORT, which was directed at the paraaortic lymphatics with a median dose of 25.2 Gy in 14 fractions for 3 weeks. The 10 remaining patients were managed by surveillance. The median follow-up period was 96 months with a range of 24 to 155 months. Results: Clinically, most patients presented with a testicular mass or discomfort. Two of the patients had a history of undescended testes. Pathologically, 23 of the patients had intratubular germ cell neoplasia with seminoma. Both recurrence-free survival (RFS) and overall survival (OS) rates of patients treated by PORT were 100%. In the control group, 1 of the 10 patients suffered a para-aortic lymph node relapse. The RFS and OS rates of the surveillance group were 88.9% and 100%, respectively. Conclusion: No difference in survival was observed between the two groups. Moreover, symptom recurrence was only observed in 1 patient in the control group. The use of PORT may reduce the risk of relapse. With the availability of effective diagnostic and salvage modalities, surveillance monitoring may be considered for patients in good compliance.

Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT (세기조절방사선치료의 환자별 정도관리를 위한 2차원적 선량계의 유용성 평가)

  • Hong, Chae-Seon;Lim, Jong-Soo;Ju, Sang-Gyu;Shin, Eun-Hyuk;Han, Young-Yih;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.91-102
    • /
    • 2009
  • Purpose: To compare the accuracy and efficacy of EDR2 film, a 2D ionization chamber array (MatriXX) and an amorphous silicon electronic portal imaging device (EPID) in the pre-treatment QA of IMRT. Materials and Methods: Fluence patterns, shaped as a wedge with 10 steps (segments) by a multi-leaf collimator (MLC), of reference and test IMRT fields were measured using EDR2 film, the MatriXX, and EPID. Test fields were designed to simulate leaf positioning errors. The absolute dose at a point in each step of the reference fields was measured in a water phantom with an ionization chamber and was compared to the dose obtained with the use of EDR2 film, the MatriXX and EPID. For qualitative analysis, all measured fluence patterns of both reference and test fields were compared with calculated dose maps from a radiation treatment planning system (Pinnacle, Philips, USA) using profiles and $\gamma$ evaluation with 3%/3 mm and 2%/2 mm criteria. By measurement of the time to perform QA, we compared the workload of EDR2 film, the MatriXX and EPID. Results: The percent absolute dose difference between the measured and ionization chamber dose was within 1% for the EPID, 2% for the MatriXX and 3% for EDR2 film. The percentage of pixels with $\gamma$%>1 for the 3%/3 mm and 2%/2 mm criteria was within 2% for use of both EDR2 film and the EPID. However, differences for the use of the MatriXX were seen with a maximum difference as great as 5.94% with the 2%/2 mm criteria. For the test fields, EDR2 film and EPID could detect leaf-positioning errors on the order of -3 mm and -2 mm, respectively. However it was difficult to differentiate leaf-positioning errors with the MatriXX due to its poor resolution. The approximate time to perform QA was 110 minutes for the use of EDR2 film, 80 minutes for the use of the MatriXX and approximately 55 minutes for the use of the EPID. Conclusion: This study has evaluated the accuracy and efficacy of EDR2 film, the MatriXX and EPID in the pre-treatment verification of IMRT. EDR2 film and the EPID showed better performance for accuracy, while the use of the MatriXX significantly reduced measurement and analysis times. We propose practical and useful methods to establish an effective QA system in a clinical environment.

Long Term Clinical Results of Triple Valve Replacement (삼중 판막 대치술의 장기 결과)

  • Yu, Song-Hyeon;Hong, You-Sun;Chang, Byung-Chul;Kang, Meyun-Shick;Lim, Sang-Hyun
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.675-679
    • /
    • 2005
  • Background: Clinical reports on replacement of all three (AV + MV + TV) valves are rare. Material and Method: From January 1992 to December 2003, 38 patients received triple valve replacement (aortic, mitral, tricuspid) at Yonsei Cardiovascular Center. Mean age of patients was $49.5\pm10.7 (28\~69)$ years, and 24 patients $(63.1\%)$ were female. Rheumatic valve disease was the most common cause of operation (n=37). Preoperative New York Heart Association functional class were II in 4, III in 24 and IV in 10. Fifteen patients (group 1) received triple valve replacement at their first operation. Twenty three patients (group 2) received one or more operations before tricuspid valve replacement (TVR). Seven patients received tricuspid valve annuloplasty at first operation and received TVR later. Result: Six patients died at hospital after operation $(15.8\%)$ and all these patients were in group 2. All patients in group I survived and were discharged. Three patients $(9.4\%)$ died during follow up periods. Most of the survivors had improved functional class (I in 22, II in 8, III in 1, IV in 1). During follow up period, there were 4 valve related complications. The 10-year survival rate was $68.8\%$ and survival rate for free from valve related event at 10 years was $85.5\%$. Conclusion: After triple valve replacement, most patients showed improvement of symptoms. And during follow up period, valve related complications and survival were acceptable. Therefore, if indicated, triple valve replacement is recommended before the patients' conditions get worse.

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF