• Title/Summary/Keyword: 6 MV

Search Result 875, Processing Time 0.028 seconds

Conformal Radiotherapy in a Patient with Cancer at the base of the Tongue in a Previously Irradiated Area (방사선치료 조사영역 내에 발생한 설암 환자에서 입체조형방사선치료 경험 : 증례보고)

  • Cho Moon-June;Kim Ki-Hwan;Kim Byung-Kook;Song Chang-Joon;Kim Jun-Sang;Kim Jae-Sung;Jang Ji-Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.59-62
    • /
    • 2001
  • Objectives: We report an interim result of conformal radiotherapy in a patient with early stage cancer at the base of the tongue, which developed in a previously irradiated area. Materials and Methods: A 64-year-old male patient was diagnosed with T4N0M0 supraglottic cancer. He received 72Gy of radiation therapy from 21 November 1988 to 24 February 1989. He had local failure and underwent a salvage total laryngectomy on 28 August 1989. Subsequently, he did well. In early 1999, he suffered from throat pain. He had a 2.5cm ulcerative mass at the base of his tongue, in the area that had been irradiated previously. Biopsy showed squamous cell carcinoma. After workup, he was diagnosed with base of tongue cancer with T2N0M0. Surgery was not feasible because the morbidity was not acceptable. Since it was difficult to re-irradiate the area with a curable dose using conventional 2D radiation therapy with an acceptable morbidity, we decided to try conformal radiotherapy. We used 7 static beam ports with field sizes from $7x6.4\;to\;8x8cm^2$, using 6 and 10MV photons. The fractionation regimen was 1.8Gy, 5 times per week. He received 64.8Gy in 36 fractions from 9 April 1999 to 1 June 1999. Results: In the 21 months since radiotherapy, the patient has not experienced any acute or chronic complications, such as xerostomia. He experienced relief of pain shortly after the start of radiotherapy, showed a complete response, and is still doing well. Conclusion: Conformal radiotherapy can be used to treat cancer that develops within a previously irradiated field, with curative intent.

  • PDF

The Role of Radiation Therapy in the Unresectable Rectal Cancers (절제 불가능 직장암에서 방사선 치료의 역할)

  • Kim, Woo-Cheol;Seong, Jin-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.2
    • /
    • pp.173-180
    • /
    • 1995
  • Purpose: Unresectable rectal cancer has a grave prognosis. regardless of the therapy used and median survival is less than 1 rear. Also, it is reported by many authors that $50-80\%$ of unresectable lesions were rendered resectable by radiation therapy and the median survival time for the completely resected patients were better than that of the unresected patients. So we analyzed retrospectively our data for the better treatment outcome in these patients. Materials and MEthods:From 1980 to 1992, 45 patients with initially unresectable tumors in the rectum were treated with radiation therapy with/without surgery in Department of Radiation Oncology, Yonsei Cancer Center 10 MV radiation and multiple field technique (box or AP/PA) were used. The total dose was 28-70 Gy and median dose was 48 Gy. We evaluated the lesion status at 45-50 Gy for operability. If the lesions appeared to be resectable, the Patients were operated on 4-6 weeks after radiation therapy. But if the lesions were still fixed, the radiation dose was increased to 60-65 Gy. Results: For all patients, the 2-year actuarial survival was $13.3\%$ and median survival was 9.5 months. Of 6 patients who had received less than 45 Gy, only $17\%$ of patients responded, but in the patients who had received more than 45 Gy, $60\%$ of response rate was achieved Six of the 24 patients$(25\%)$ underwent surgical resections following RT. For patients undergoing curative resection. the two-rear survival was $50\%,$ but that of the patients without resection was $9.5\%$ (p<0.01). Survival of patients with complete response following RT was $50\%$ at 2 years. Survival of patients with partial response, stable disease and progressive disease after RT was $13.4\%,\;15.4\%,\;0\%$ respectively (P<0.05). Conclision: Our data suffests that the efforts which can increase the response rate and aggressive surgical approach are needed to achieve the better local control and survival in unresectable rectal cancers.

  • PDF

Comparison of Dosimetrical and Radiobiological Parameters on Three VMAT Techniques for Left-Sided Breast Cancer

  • Kang, Seong-Hee;Chung, Jin-Beom;Kim, Kyung-Hyeon;Kang, Sang-Won;Eom, Keun-Yong;Song, Changhoon;Kim, In-Ah;Kim, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.7-13
    • /
    • 2019
  • Purpose: To compare the dosimetrical and radiobiological parameters among various volumetric modulated arc therapy (VMAT) techniques using restricted and continuous arc beams for left-sided breast cancer. Materials and Methods: Ten patients with left-sided breast cancer without regional nodes were retrospectively selected and prescribed the dose of 42.6 Gy in 16 fractions on the planning target volume (PTV). For each patient, three plans were generated using the $Eclipse^{TM}$ system (Varian Medical System, Palo Alto, CA) with one partial arc 1pVMAT, two partial arcs 2pVMAT, and two tangential arcs 2tVMAT. All plans were calculated through anisotropic analytic algorithm and photon optimizer with 6 MV photon beam of $VitalBEAM^{TM}$. The same dose objectives for each plan were used to achieve a fair comparison during optimization. Results: For PTV, dosimetrical parameters such as Homogeneity index, conformity index, and conformal number were superior in 2pVMAT than those in both techniques. $V_{95%}$, which indicates PTV coverage, was 91.86%, 96.60%, and 96.65% for 1pVMAT, 2pVMAT, and 2tVMAT, respectively. In most organs at risk (OARs), 2pVMAT significantly reduced the delivered doses compared with the other techniques, excluding the doses to contralateral lung. For the analysis of radiobiological parameters, a significant difference in normal tissue complication probability was observed in ipsilateral lung while no difference was observed in the other OARs. Conclusions: Our study showed that 2pVMAT had better plan quality and normal tissue sparing than 1pVMAT and 2tVMAT but not for all parameters. Therefore, 2pVMAT could be considered the priority choice for the treatment planning for left breast cancer.

Study on the LNG Vaporization Characteristics of Open Rack Vaporizer(ORV) with Two-way Seawater Supplying System (해수 2단 공급에 따른 해수식 기화기(ORV)의 LNG 기화 특성 연구)

  • Kim, Nam-Kug;Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.41-46
    • /
    • 2019
  • LNG is supplying to consumers as gas phase vaporized by major seawater vaporizer, i.e.. open rack vaporizers. But as soon as the temperature of seawater drops below $5^{\circ}C$ in winter, the submerged evaporators should be operated and cause a lot of energy consumption because of their natural gas combustion. In order to reduce the consumption amount, in this study new two-way supplying method of seawater instead of the present one-way supplying system is introduced and analysed the technical possibilities and economical savings. The results showed that in case of the temperature of seawater becomes below $2.5^{\circ}C$, LNG can be evaporated using ORV without operating S MV. If this system is applied in Incheon LNG terminal, the energy saving reaches 11,770 Ton of LNG as 11,760 million won. By the analysis, the two-way supplying system of seawater in ORV can be the most effective method to be able to save huge amount of energy every year.

Measurement of Growth and Chlorophyl in Barley Exposed by X-ray (X선에 노출된 보리의 생장과 엽록소 측정)

  • Lee, Won-Jeong;Lee, Mo-Kwon;Lee, Jung Rok;Kim, Ha Neul;Yoo, Se-Jong;Lee, Bae-Won;Jeong, Sun-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.253-260
    • /
    • 2021
  • The purpose of this study is to measure of growth and chlorophyl in barley exposed by X-ray. Barley seed was soaked 24h duration in water, then was classified into two group; pre-seed germination group (Pre-G) or post-seed germination group (Post-G). Also, divided as control subgroup and experimental subgroup(10Gy, 20Gy, 30Gy) in each group. Experimental subgroups were exposed by X-ray using linear accelerator (Clinac IS, VERIAN, USA). Expose condition was 6 MV X-ray, SSD 100 cm, 18×10 cm, 600 MU/min. Length was measured every day for 10 days and 10th day for weight. Chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) in l0th day. Data analysis was performed using SPSS ver 22.0(Chicago, IL, USA), ANOVA test (Dunnett_T3) between control subgroup and experimental subgroup in group and Independent T-test between Pre-G and Post-G in subgroup. In Pre-G, length of barley was significantly difference between control and 30Gy in 4th day (4.3 vs. 1.5, p= 0.011). Length of 30Gy was statistical difference with control(10th day; 14.4 vs. 6.3, p < 0.01), and was not in 10Gy or 20Gy in all day. In experimental subgroup, length was shorter as increasing radiation dose. In Post-G, length of barley was not difference statistically between control and experimental subgroup in first day, but more difference between two subgroup with increasing duration after exposing. Length of experimental subgroup was shorter significantly compared with control in 10th day, and no significant difference between experimental subgroup. Density of chlorophyl was increasing with increasing radiation dose in Pre-G and Post-G. Chlorophyl density of control was lower than 30Gy; 0.26ppm in Pre-G, 0.29ppm in Post-G). Growth and chlorophyl of barley was effected by X-ray. It is expected to be used as basic data for future radiobiological research.

Monte Carlo Algorithm-Based Dosimetric Comparison between Commissioning Beam Data across Two Elekta Linear Accelerators with AgilityTM MLC System

  • Geum Bong Yu;Chang Heon Choi;Jung-in Kim;Jin Dong Cho;Euntaek Yoon;Hyung Jin Choun;Jihye Choi;Soyeon Kim;Yongsik Kim;Do Hoon Oh;Hwajung Lee;Lee Yoo;Minsoo Chun
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.150-157
    • /
    • 2022
  • Purpose: Elekta synergy® was commissioned in the Seoul National University Veterinary Medical Teaching Hospital. Recently, Chung-Ang University Gwang Myeong Hospital commissioned Elekta Versa HDTM. The beam characteristics of both machines are similar because of the same AgilityTM MLC Model. We compared measured beam data calculated using the Elekta treatment planning system, Monaco®, for each institute. Methods: Beam of the commissioning Elekta linear accelerator were measured in two independent institutes. After installing the beam model based on the measured beam data into the Monaco®, Monte Carlo (MC) simulation data were generated, mimicking the beam data in a virtual water phantom. Measured beam data were compared with the calculated data, and their similarity was quantitatively evaluated by the gamma analysis. Results: We compared the percent depth dose (PDD) and off-axis profiles of 6 MV photon and 6 MeV electron beams with MC calculation. With a 3%/3 mm gamma criterion, the photon PDD and profiles showed 100% gamma passing rates except for one inplane profile at 10 cm depth from VMTH. Gamma analysis of the measured photon beam off-axis profiles between the two institutes showed 100% agreement. The electron beams also indicated 100% agreement in PDD distributions. However, the gamma passing rates of the off-axis profiles were 91%-100% with a 3%/3 mm gamma criterion. Conclusions: The beam and their comparison with MC calculation for each institute showed good performance. Although the measuring tools were orthogonal, no significant difference was found.

Feasibility of a Linear Diode Array Detector for Commissioning of a Radiotherapy Planning System

  • Seung Mo Hong;Uiseob Lee;Sung-woo Kim;Youngmoon Goh;Min-Jae Park;Chiyoung Jeong;Jungwon Kwak;Byungchul Cho
    • Progress in Medical Physics
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: Although ionization chambers are widely used to measure beam commissioning data, point-by-point measurements of all the profiles with various field size and depths are time-consuming tasks. As an alternative, we investigated the feasibility of a linear diode array for commissioning a treatment planning system. Methods: The beam data of a Varian TrueBeam® radiotherapy system at 6 and 10 MV with/without a flattening filter were measured for commissioning of an Eclipse Analytical Anisotropic Algorithm (AAA) ver.15.6. All of the necessary beam data were measured using an IBA CC13 ionization chamber and validated against Varian "Golden Beam" data. After validation, the measured CC13 profiles were used for commissioning the Eclipse AAA (AAACC13). In addition, an IBA LDA-99SC linear diode array detector was used to measure all of the beam profiles and for commissioning a separate model (AAALDA99). Finally, the AAACC13 and AAALDA99 dose calculations for each of the 10 clinical plans were compared. Results: The agreement of the CC13 profiles with the Varian Golden Beam data was confirmed within 1% except in the penumbral region, where ≤2% of a discrepancy related to machine-specific jaw calibration was observed. Since the volume was larger for the CC13 chamber than for the LDA-99SC chamber, the penumbra widths were larger in the CC13 profiles, resulting in ≤5% differences. However, after beam modeling, the penumbral widths agreed within 0.1 mm. Finally the AAALDA99 and AAACC13 dose distributions agreed within 1% for all voxels inside the body for the 10 clinical plans. Conclusions: In conclusion, the LDA-99SC diode array detector was found to be accurate and efficient for measuring photon beam profiles to commission treatment planning systems.

Smad6 Gene and Suppression of Radiation-Induced Apoptosis by Genistein in K562 Cells (K562 세포주에서 Genistein에 의해 억제되는 Radiation-induced Apoptosis의 조절 유전자)

  • Jeong, Soo-Jin;Jin, Young-Hee;Yoo, Yeo-Jin;Do, Chang-Ho;Jeong, Min-Ho;Huh, Gi-Yeong;Bae, Hye-Ran;Yang, Kwang-Mo;Moon, Chang-Woo;Oh, Sin-Geun;Hur, Won-Joo;Lee, Hyung-Sik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.245-251
    • /
    • 2001
  • Prupose : The genes involved on the suppression or radiation-induced apoptosis by genistein in K562 leukemia cell line was investigated. Materials and methods : K562 cells in exponential growth phase were irradiated with a linear accelerator at room temperature. For X-ray irradiation and drug treatment, cultures were prepared at $2\times10^5\;cells/mL$. The cells were irradiated with 10 Gy (Clinac 1800C, Varian, USA), Stock solutions of herbimycin A (HMA, Calbiochem, UK) and genistein (Calbiochem, UK) were prepared in dimethylsulfoxide (DMSO, Sigma, UK). After incubation at $37^{\circ}C$ for 24 h, PCR-select cDNA subtractive hybridization, dot hybridization, DNA sequencing and Northern hybridization were examined. Results : Smad6 gene was identified from the differentially expressed genes in K562 cells incubated with genistein which had been selected by PCR-select cDNA subtractive hybridization. The mRNA expression of Smad6 in K562 cells incubated with genistein was also higher than control group by Northern hybridization analysis. Conclusion : We have shown that Smad6 involved on the suppression of radiation-induced apoptosis by genistein in K562 leukemia cell line. It is plausible that the relationship between Smad6 and the suppression of radiation-induced apoptosis is essential for treatment development based on molecular targeting designed to modify radiation-induced apoptosis.

  • PDF

Individualized Determination of Lower Margin in Pelvic Radiation Field after Low Anterior Resection for Rectal Cancer Resulted in Equivalent Local Control and Radiation Volume Reduction Compared with Traditional Method (하전방 절제술을 시행한 직장암 환자에서 방사선조사 영역 하연의 개별화)

  • Park Suk Won;Ahn Yong Chan;Huh Seung Jae;Chun Ho Kyung;Kang Won Ki;Kim Dae Yong;Lim Do Hoon;Noh Young Ju;Lee Jung Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.194-199
    • /
    • 2000
  • Purpose : Then determining the lower margin of post-operative pelvic radiation therapy field according to the traditional method (recommended by Gunderson), the organs located in the low pelvic cavity and the perineum are vulnerable to unnecessary radiation. This study evaluated the effect of individualized determination of the lower margin at 2 cm to 3 cm below the anastomotic site on the failure patterns. Materials and Methods . Authors included ぉ patients with modified Astler-Coiler (MAC) stages from B2 through C3, who received low anterior resection and post-operative pelvic radiation therapy from Sept. 1994 to May 1998 at Samsung Medical Center, Sungkyunkwan University. The numbers of male and female patients were 44 and 44, and the median age was 57 years (range: 32-81 years). Three field technique (posterior-anterior and bilateral portals) by 6, 10, 15 MV X-rays was used to deliver 4,500 cGy to the whole pelvis followed by Sn cGy's small field boost to the tumor bed over 5.5 weeks. Sixteen patients received radiation therapy by traditional field margin determination, and the lower margin was set either at the low margin of the obturator foramen or at 2 cm to 3 cm below the anastomotic site, whichever is lower. In 72 patients, the lower margin was set at 2 cm to 3 cm below the anastomotic site, irrespectively of the obturator foramen, by which the reduction of radiation volume was possible in 55 patients ($76\%$). Authors evaluated and compared survival, local control, and disease-free survival rates of these two groups. Results : The median follow-up period was 27 months (range : 7-58 months). MAC stages B2 in 32($36\%$), B3 in 2 ($2\%$), Cl in 2 ($2\%$), C2 in 50 ($57\%$), and C3 in 2 ($2\%$) Patients, respectively. The entire patients' overall survival rates at 2 and 4 years were $94\%$ and $68\%$, respectively, and disease-free survival rates at 2 and 4 years were $86\%$ and $58\%$, respectively. The first failure sites were local only in 4, distant only in 14, and combined local and distant in 1 patient, respectively. There was no significant difference with respect to local control and disease-free survival rates ( p=0.42, p=0.68) between two groups of different lower margin determination policies. Conclusion : The new concept in the individualized determination of the lower margin depending on the anastomotic site has led to the equivalent local control and disease-free survival rates, and is expected to contribute to the reduction of unnecessary radiation-related morbidity by reduction of radiation volume, compared with the traditional method of lower margin determination.

  • PDF

Radiation Therapy and Chemotherapy after Breast Conserving Surgery for Invasive Breast Cancer: An Intermediate Result (침윤성 유방암에서 유방보존수술 후 방사선치료 및 항암화학 병용치료의 성적 및 위험인자 분석)

  • Lee, Seok-Ho;Choi, Jin-Ho;Lee, Young-Don;Park, Heoung-Kyu;Kim, Hyun-Young;Park, Se-Hoon;Lee, Kyu-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.16-25
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Breast conserving surgery (BCS) followed by chemotherapy (CTx.) and radiation therapy (RT) is widely performed for the treatment of early breast cancer. This retrospective study was undertaken to evaluate our interim results in terms of failure patterns, survival and relative risk factors. $\underline{Materials\;and\;Methods}$: From January 1999 through December 2003, 129 patients diagnosed with invasive breast cancer and treated with BCS followed by RT were subject to retrospective review. The median age of the patients was 45 years (age distribution, $27{\sim}76$ years). The proportions of patients according to their tumor, nodes, and metastases (TNM) stage were 65 (50.4%) in stage I, 41 (31.7%) in stage IIa, 13 (10.1%) in stage IIb, 9 (7.0%) in stage III, and 1 patient (0.8%) in stage IIIc. For 32 patients (24.8%), axillary node metastasis was found after dissection. BCS consisted of quadrantectomy in 115 patients (89.1%) and lumpectomy in 14 patients (10.6%). Axillary node dissection at axillary level I and II was performed for 120 patients (93%). For 7 patients (5.4%), only sentinel node dissection was performed with BCS. For 2 patients (1.6%) axillary dissection of any type was not performed. Postoperative RT was given with 6 MV X-rays. A tumor dose of 50.4 Gy was delivered to the entire breast area using a tangential field with a wedge compensator. An aditional dose of $9{\sim}16\;Gy$ was given to the primary tumor bed areas with electron beams. In 30 patients (23.3%), RT was delivered to the supraclavicular node. Most patients had adjuvant CTx. with $4{\sim}6$ cycles of CMF (cyclophosphamide, methotrexate, 5-fluorouracil) regimens. The median follow-up period was 50 months (range: $17{\sim}93$ months). $\underline{Results}$: The actuarial 5 year survival rate (5Y-OSR) was 96.9%, and the 5 year disease free survival rate (5Y-DFSR) was 93.7%. Local recurrences were noted in 2 patients (true: 2, regional node: 1) as the first sign of recurrence at a mean time of 29.3 months after surgery. Five patients developed distant metastases as the first sign of recurrence at $6{\sim}33$ months (mean 21 months). Sites of distant metastatic sites were bone in 3 patients, liver in 1 patient and systemic lesions in 1 patient. Among the patients with distant metastatic sites, two patients died at 17 and 25 months during the follow-up period. According to stage, the 5Y-OSR was 95.5%, 100%, 84.6%, and 100% for stage I, IIa, IIb, and III respectively. The 5Y-DFSR was 96.8%, 92.7%, 76.9%, and 100% for stage I, IIa, IIb, and III respectively. Stage was the only risk factor for local recurrence based on univariate analysis. Ten stage III patients included in this analysis had a primary tumor size of less than 3 cm and had more than 4 axillary lymph node metastases. The 10 stage III patients received not only breast RT but also received posterior axillary boost RT to the supraclavicular node. During the median 53.3 months follow-up period, no any local or distant failure was found. Complications were asymptomatic radiation pneumonitis in 10 patients, symptomatic pneumonitis in 1 patient and lymphedema in 8 patients. $\underline{Conclusion}$: Although our follow up period is short, we had excellent local control and survival results and reaffirmed that BCS followed by RT and CTx. appears to be an adequate treatment method. These results also provide evidence that distant failure occurs earlier and more frequent as compared with local failure. Further studies and a longer follow-up period are needed to assess the effectiveness of BCS followed by RT for the patients with less than a 3 cm primary tumor and more than 4 axillary node metastases.