• Title/Summary/Keyword: 5VOC

Search Result 346, Processing Time 0.03 seconds

Durability Characteristics of Concrete with Nano Level Ceramic Based Coating (나노합성 세라믹계 도장재를 도포한 콘크리트의 내구성능)

  • Kim, Seong-Soo;Lee, Jeong-Bae;Han, Seung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.639-646
    • /
    • 2007
  • This study performed several tests for the durability of the concrete coated with nano synthesis ceramics which do not contain volatile organic compounds harmful to environment. The tests were adhesion test on dry and humid concrete, SEM test, MIP analysis, carbonation, chloride diffusion by electronic facilitation, freezing-thawing resistance, alkaline resistance, and brine resistance test. In the adhesion test on dry and humid concrete, nano synthesis ceramics coating produced the highest results among all the coatings tested. Nano synthesis ceramics adhered solidly on the concrete surface. The adhesive strength seemed to result from the hydrogen bond between nano synthesis ceramics which are inorganic and generated by hydrolysis and re-condensation reaction and the concrete's hydrates such as calcium silicate aluminate or calcium silicate hydrate. SEM test and MIP analysis results show surface structure with finest crevices pore in the nano synthesis ceramics coating applied concretes. In the carbonation, chloride diffusion, and freezing-thawing resistance tests, the concretes with nano synthesis ceramics coating indicated the best results. Based on these test results, further progress in application of nano synthesis ceramics coatings to various concrete structures including costal structures and sewerage arrangements can be expected.

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

Relationships of TVOC with Several Aromatic Hydrocarbon Constituents at Preschool Facilities

  • Yoon, Chung-Sik;Choi, In-Ja;Ha, Kwon-Chul;Park, Dong-Uk;Park, Doo-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.404-411
    • /
    • 2006
  • 이 연구의 목적은 유치원에서 총 휘발성 유기화합물의 농도를 평가하고, 총 휘발성 유기화합물 농도와 대표적인 8개 방향족 화합물의 상관관계를 조사하는데 있다. 도시에 위치한 11개 유치원의 실내와 실외에서 각각 30개, 11개의 지역시료를, 시골에 위치한 4개 유치원에서는 각각 10개, 4개의 시료를 테낙스 튜브를 이용하여 오전에 1-2시간 채취하였다. 채취한 시료는 열탈착하여 가스크로마토그래피-질량분석기로 분석하였다. 13가지 물질을 각각의 표준물질로 개별 정량하여 이중 빈번히 발견되는 8가지 방향족 유기화합물은 상관관계 평가에 사용하였다. 총 휘발성 유기화합물은 톨루엔을 기준으로 정량하였다. 도시에 위치한 유치원 실내의 총 휘발성 유기화합물 농도가 높았고, 조사 건수의 50%가 환경부 및 교육인적자원부의 가이드라인($400{\mu}g/m^{3}$)을 초과하였다. 도시지역의 유치원 실내 및 실외의 기하평균은 각각 $387.9{\mu}g/m^{3}$$134.9{\mu}g/m^{3}$이었고, 시골지역 유치원에서는 각각 $189.6{\mu}g/m^{3},;74.4{\mu}g/m^{3}$이었다. 톨루엔, 크실렌, 에틸벤젠, 정량한 유기 화합물 총합, 총 휘발성 유기화합물은 기하정규분포를 하였다. 벤젠, 톨루엔, 에틸벤젠, 크실렌(BTEX)은 도시에 위치한 유치원에서 농도도 높고, 총 휘발성 유기화합물중 함량도 높았고, 시골지역에서는 농도와 상대적 함량이 낮았다. 도시지역에서는 총 휘발성 유기화합물 중 BTEX의 비중이 25.2%였고 정량한 13가지 유기화합물 중에서는 35.6%를 차지하였다. BTEX 각각 개별물질은 미국 환경보호청이 제시하는 일일 노출 기준량(Reference Concentration; RfC) 보다는 현저히 낮았다. 총 휘발성 유기화합물읜 농도는 실내가 실외 보다 높았다(I/O ratio 2.5). BTEX의 상대적 함량도 실내가 실외보다 높아 실내에도 발생원이 있음을 암시하고 있다. 자료 분석결과 유치원 실내의 벤젠은 실외로부터 유입되고 있었고, 톨루엔, 에틸벤젠, 크실렌은 실외뿐 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.

이중구조 투명전극을 이용한 실리콘 박막 태양전지 효율향상 기법

  • Kim, Hyeon-Yeop;Kim, Min-Geon;Choe, Jae-U;Lee, Jun-Sin;Kim, Jun-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.591-591
    • /
    • 2012
  • 본 연구는 Transparent conducting oxide (TCO, 산화물투명전극)를 이용한 박막태양전지 효율향상에 관한 것으로, 이중의 TCO층(Double-stacked TCO layer)의 효과적인 광학 및 전기적 설계에 관한 것이다. 기존 박막 태양전지에서는 투명전극 TCO layer로서, ITO (Indium-Tin-Oxide), FTO (Fluorine- Tin-Oxide), 및 AZO(Aluminum-doped Zinc Oxide) 등을 사용해 왔다. 각 TCO layer마다 장점이 있지만 단점 또한 존재한다. ITO의 경우 높은 전기적 특성을 가지는 반면 수소 플라즈마에 취약하고 기계적 강도에 취약해 ITO 단일층만으로 박막 태양전지에 적용하는 것에 제한을 받는다. 한편, AZO의 경우 전기적 특성도 우수할 뿐만 아니라 수소 플라즈마에도 내구성이 강한 장점이 있지만, 일함수가 p형 반도체보다 낮아 Schottky junction이 되어, 높은 전위장벽이 형성된다. 이는 정공의 이동을 방해하고, 정공의 축적이 일어나서 순방향 전압을 인가할 때 많은 전류의 감소를 가져온다. 또한, AZO와 p형 반도체 사이의 높은 직렬저항으로 인해 광전압(Voc, Open circuit voltage)와 충실률 (FF, Fill factor)가 떨어진다는 단점이 있다. 본 실험에서는 ITO/AZO 2중구조의 TCO층을 적용하여 상기의 문제점을 해결하고자 한다. 이중 구조 TCO층은 Magnetron sputter system을 이용하여, 단계적으로 증착되었다. 빛이 입사하는 유리에 ITO를 제1전도층으로 증착하였는데, ITO는 입사광의 투과도와 전기전도성이 우수하다. 제2전도층으로는 AZO층을 이용하였으며, 실리콘 반도체층과 접하게 된다. AZO는 실리콘 증착시 발생하는 수소 플라즈마에 안정적이고, 물리적 강도 또한 우수한 장점이 있다. 이중 구조층위에 실리콘 광흡수층(Si absorber)을 증착하였으며, pin 구조를 가진다. 기존, 단일막 TCO층과 2중구조 TCO층을 이용하여, 실리콘 박막 태양전지를 구성하였다. 이때, ITO/AZO의 2중구조를 적용하였을 때 태양 전지 특성이 크게 향상된 결과를 얻을 수가 있었다. 특히, 전류밀도의 경우 ITO, FTO, AZO 각각 14.5 mA/cm2, 11.2 mA/cm2, 8.18 mA/cm2를 나타낸 반면 ITO/AZO 2중구조의 경우 약 17mA/cm2 로 크게 향상 되었고, 태양전지 변환 효율도 각각 7.5%, 6.9%, 4%에서 ITO/AZO 2중 구조의 경우 8.05%로 크게 향상되었다. 본 발표에서는 2중구조 TCO를 이용한 현공정에 적용 가능한 박막태양전지 효율향상 기법에 대해 논의하고자 한다.

  • PDF

Standardization of Trail Difficulty based on Energy Consumption (에너지 소모량에 기초한 탐방로 난이도 표준화 연구)

  • Hong, Suk-Hwan;Kwon, Tae-Ho;Choi, Song-Hyun;Kim, Kyung-Tae;Kim, Dong-Pil
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.4
    • /
    • pp.626-635
    • /
    • 2015
  • Recently, the number of trail users in Korea has risen tremendously. Consequently, the cost of safety measures related to hiking is sharply increasing. Despite the safety cost input, the number of heart-related adverse events has been not decreasing. Therefore, this research aims to suggest the use of objective and quantitative trail use information in terms of course difficulty. The study site is Jirisan Dullegil (Jirisan Forest Trail). The currently available trail difficulty information either provides the difficulty rating in terms of 3 to 5 levels according to several empirical difficulty factors reported by staff who maintain the forest or simply states the distance of each trail. Thus, many trail visitors feel a great gap between the given information and actual difficulties they experience. In this study, we tried to assess the degree of difficulty by actual energy consumption. Calculating the volumetric oxygen consumption (VOC) by the distance and gradient not only makes possible an absolute rating but a comparison among the trails as well. Also, it is highly effective to simply describe the exercise intensity of a certain trail. Further, it is easy to check the VOCs' changes by switching the start-end points of the same trail. Providing the trail information of VOCs by sections and directions, we expect to prevent heart-related accidents.

Removal Characteristics of Volatile Organic Compounds in Biofilters and Stoichiometric Analysis of Biological Reaction by Carbon Mass Balance (바이오필터의 휘발성유기화합물 제거특성 및 탄소물질수지를 이용한 생물반응의 양론적 해석)

  • Kim, Dae-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.747-753
    • /
    • 2010
  • This study was performed to investigate the removal characteristics of volatile organic compounds (VOCs) in the gasphase biofilters, and to propose a stoichiometric analysis approach to characterize biological reaction through carbon mass balance. The VOCs studied were toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) as a single substrate for each biofilter. The critical loading rate was determined to be $46.9\;g/m^3{\cdot}hr$, $25.8\;g/m^3{\cdot}hr$, $96.3\;g/m^3{\cdot}hr$, and $66.5\;g/m^3{\cdot}hr$ for toluene, styrene, MEK, and MIBK, respectively. The obtained results indicated that the critical loading rate was well correlated the octanol-water partition coefficient. In the analysis of carbon mass balance, carbon recovery to $CO_2$ became relatively lower as substrate loadings increased, but higher for carbon recovery to biomass. Stoichiometric analysis revealed that biomass yield increased as substrate loadings increased, and its coefficient (g biomass/g substrate) varied from 0.31 to 0.57 for toluene, 0.29 to 0.57 for styrene, 0.08 to 0.56 for MEK, and 0.14 to 0.53 for MIBK.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Human Health Risk Assessment of BTEX from Daesan Petrochemical Industrial Complex (대산 석유화학 산업단지 인근 지역에서의 BTEX 인체 위해성 평가)

  • Lee, Jihyeong;Jang, Yong-Chul;Cheon, Kwangsoo;Kim, Bora
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.321-333
    • /
    • 2022
  • In this study, the concentration and distribution characteristics of BTEX (benzene toluene, ethylbenzene, and xylene) emitted from Daesan Petrochemical Industrial Complex were examined to determine their potential hazards to local residents. Residents living nearby the complex areas may be exposed to the chemicals through various media (air, water, and soil), especially by air. This study evaluated human health risks by inhalation using both deterministic and probabilistic risk assessment approaches. As a result of the deterministic risk assessment, the non-cancer risk was much lower than the regulation limit of hazard index (HI 1.0) for all the points. However, in case of cancer risk evaluation, it was found that the risk of excess cancer for benzene at point A located in the industrial complex was 2.28×10-6, which slightly exceeded the standard regulatory limit of 1.0×10-6. In addition, the probabilistic risk assessment revealed that the percentile exceeding the standard of 1.0×10-6was found to be 45.3%. The sensitivity analysis showed that exposure time (ET) had the greatest impact on the results. Based on the risk assessment study, it implied that ethylbenzene, toluene, and xylene had little adverse effects on potential human exposure, but benzene often exceeded the cancer risk standard (1.0×10-6). Further studies on extensive VOCs monitoring are needed to evaluate the potential risks of industrial complex areas.

Comparison of Instrument Characteristics on the Total Organic Carbon Analysis Method in Water Samples (수질분야 총유기탄소 분석방법에 따른 장비별 특성 비교)

  • Hye-Sung Kim;Eun-Tae Hwang;Chan-Geun Lee;Young-Cheol Cho
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.353-362
    • /
    • 2023
  • TOC, which can measure more than 90% of organic substances, can be measured quickly and easily,replacing BOD and COD, which were indicators of organic pollutants. According to water quality pollution control standards, when measuring TOC, if the inorganic carbon ratio in the sample is over 50%, the NPOC (Non-Purgeable Organic Carbon) method should be used. If volatile organic compounds (VOCs) are present at a certain concentration, the TC-IC (subtracting inorganic carbon from total carbon) method should be used. To validate the limitations of these analytical conditions, experiments were conducted by varying the ratio of TOC to IC in purified water and measuring the concentration of TOC in test solutions. The results showed no significant difference between the TC-IC method and the NPOC method. When measuring samples with added VOC standard solutions, it was observed that the carbon loss due to purging was not significant when using the NPOC method. Therefore, it is concluded that the choice of analytical method does not lead to significant differences when VOCs are present in the sample. To account for potential variations in results based on water quality pollution control standards and regulations regarding the approval and testing of environmental measurement devices, a comparison of field sample concentration values was made using two widely used types of TOC analyzers in Korea. The results showed variations of 0.02 to 0.83 mg/L between methods depending on the manufacturer, highlighting the need for caution when selecting an instrument.

A study on the calibration characteristics of organic fatty acids designated as new offensive odorants by cryogenic trapping-thermal desorption technique (유기지방산 신규악취물질에 대한 저온농축 열탈착방식 (Thermal desorber)의 검량특성 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Im, Moon-Soon;Ju, Do-Weon
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.488-497
    • /
    • 2009
  • In this study, analytical methodology for several organic fatty acids (OFA: propionic acid (PA), butyric acid (BA), isovaleric acid (IA), and valeric acid (VA)) designated as new offensive odorants in Korea (as of year 2010) was investigated along with some odorous VOCs (styrene, toluene, xylene, methyl ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol). For this purpose, working standards (WS) containing all of these 13 compounds were loaded into adsorption tube filled with Tenax TA, and analyzed by gas chromatography (GC) system thermal desorber interfaced with. The analytical sensitivities of organic fatty acids expressed in terms of detection limit (both in absolute mass (ng) and concentration (ppb)) were lower by 1.5-2 times than other compounds (PA: 0.24 ng (0.16 ppb), BA: 0.19 ng (0.11 ppb), IA: 0.15 ng (0.07 ppb), and VA: 0.28 ng (0.13 ppb)). The precision of BA, IA, and VA, if assessed in terms of relative standard error (RSE), maintained above 5%, while the precison of other compounds were below 5%. The reproducibility of analysis improved with the aid of internal standard calibration (PA: $1.1{\pm}0.4%$, BA: $10{\pm}0.46$, IA; $12{\pm}0.3%$, VA: $4{\pm}0.1%$), respectively. The results of this study showed that organic fatty acid can be analyzed using adsorption tube and thermal desorber in a more reliable way to replace alkali absorption method introduced in the odor prevention law of the Korea Ministry of Environment (KMOE).