• 제목/요약/키워드: 5-level inverter

검색결과 145건 처리시간 0.024초

특정 고조파 제거를 위한 Cascaded H-bridge 7레벨 인버터의 특성해석 및 시뮬레이션 (Analysis and simulation of Cascaded H-bridge 7 level inverter for eliminating typical harmonic waveforms)

  • 진선호;오진석;조관준;곽준호;임명규;김장목
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1022-1028
    • /
    • 2005
  • This paper is presented the analysis results and simulation results of cascaded H-bridge 7 level inverter with various modulation index. Stepped waveform having number of switching was used to eliminate harmonic components. Switching angles according to modulation index are calculated numerically. Therefore, 3 times of switching with 7 level topology and QWS(Quarter Wave Symmetry) could eliminate 5th and 7th harmonics. The harmonic characteristics are compared to those of space vector modulation method which known as common modulation method in industrial field. Stepped waveform method showed higher ability to reduce, especially lower order of harmonics.

  • PDF

SRM의 여자제어를 위한 멀티레벨 인버터 (Multi-level Inverter for the Excitation Control of an SRM)

  • 이상훈;박성준;안진우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권4호
    • /
    • pp.161-169
    • /
    • 2003
  • The applications of SRM(Switched Reluctance motor) are dramatically increasing due to a simple mechanical structure, a high efficiency and a high speed drive characteristics. Energy recovery in the regenerative region is very important when SRM is used in traction drive. This is to reduce energy loss during mechanical braking and/or to have a high efficiency drive. To control excitation voltage during motoring and regenerating voltage in the generator operation in the SRM, multi-level voltage control is effective. This paper suggests multi-level inverter which is useful for motoring and regenerative operation. The proposed method is verified through simulations and experiments.

Harmonic Current Compensation based on Three-phase Three-level Shunt Active Filter using Fuzzy Logic Current Controller

  • Salim, Chennai;Benchouia, M.T.;Golea, A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.595-604
    • /
    • 2011
  • A three-phase three-level shunt active filter controlled by fuzzy logic current controller which can compensate current harmonics generated by nonlinear loads is presented. Three-level inverters and fuzzy controllers have been successfully employed in several power electronic applications these past years. To improve the conventional pwm controller performance, a new control scheme based on fuzzy current controller is adopted for three-level (NPC) shunt active filter. The scheme is designed to improve compensation capability of APF by adjusting the current error using a fuzzy rule. The inverter current reference signals required to compensate harmonic currents use the synchronous reference detection method. This technique is easy to implement and achieves good results. To maintain the dc voltage across capacitor constant and reduce inverter losses, a proportional integral voltage controller is used. The simulation of global system control and power circuits is performed using Matlab-Simulink and SimPowerSystem toolbox. The results obtained in transient and steady states under various operating conditions show the effectiveness of the proposed shunt active filter based on fuzzy current controller compared to the conventional scheme.

PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(II) -능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제- (A Study on the Reduction of high frequency leakage current in PWM inverter fed Induction Motor)

  • 성병모;류도형;박성준;김철우
    • 전력전자학회논문지
    • /
    • 제5권5호
    • /
    • pp.443-450
    • /
    • 2000
  • PWM 인버터에 의하여 구동되는 유도전동기는 뛰어난 동작특성을 가지고 있지만, 커먼 모드 전압과 고주파 누설전류를 야기한다. 이 고주파 누설 전류는 여러가지 문제점을 일으킨다. 본 논문에서는 이러한 문제점을 일으키는 고주파 누설 전류와 커먼 모드 진압을 감쇄하기 위하여 커먼 모드 전압과 크기가 같고 반대극성을 가진 전압을 4 level half bridge 인버터를 이용하여 생성하고, 이것을 커먼 모드 transformer에 인가하여 고주파 누설 전류 역시 감쇄시킬 수 있는 새로운 형태의 능동형 커먼 모드 전압 감쇄기를 제안한다. 그리고 제안한 감쇄기의 동작 성능을 시뮬레이션과 실험을 통하여 검증하였다.

  • PDF

An Improved SVPWM Control of Voltage Imbalance in Capacitors of a Single-Phase Multilevel Inverter

  • Ramirez, Fernando Arturo;Arjona, Marco A.
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1235-1243
    • /
    • 2015
  • This paper presents a modified Space Vector Pulse Width Modulation Technique (SVPWM), which solves the well-known problem of voltage imbalance in the capacitors of a single-phase multilevel inverter. The proposed solution is based on the measurement of DC voltage levels at each capacitor of the inverter DC bus. The measurements are then used to adjust the size of the active vectors within the SVPWM algorithm to keep the voltage waveform sinusoidal regardless of any voltage imbalance on the DC link capacitors. When a voltage deviation exceeds a predetermined hysteresis band, the correspondent voltage vector is restricted to restore the voltage level to an acceptable threshold. Hence, the need for external voltage regulators for the voltage capacitors is eliminated. The functionality of the proposed algorithm is successfully demonstrated through simulations and experiments on a grid tied application.

멀티레벨 인버터와 다상 유도기를 이용한 견인기용 대전력 VSI의 구조와 특성 (Configurations of High Power VSI Drives for Traction Applications Using Multi Level Inverters and Multi Phase Induction Motors)

  • ;류홍제;김종수;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.500-504
    • /
    • 1997
  • Current source inverter drives of auto sequentially commutated type are very popular in high power applications, because of simple power circuit configuration with four quadrant operation. But the six-step current output create harmonic problems and the input power factor of such a drive is not always good. In this respect pulse width modulated drives using gate turn off thyristors ( GTO ) are finding application, especially in traction drives. However the switching and snubber loses of a GTO do not permit the inverter switching frequency go beyond a few hundred hertz.This will again introduce low frequency harmonic problems. Multi level inverters of the 3-level and 5-level can be considered as an alternative to overcome the low switching frequency harmonic problem of the 2-level GTO inverters. But with multi level inverters the complexity of the power circuit increases. In this paper a combination of multi level ( 2-level and 3-level ) inverters and multi phase induction motor ( 3-phase and 6-phase) configurations are presented for high power VSI drives for traction applications with reduced inverter switching frequency requirements coupled with reduced voltage rating for the power switch.

  • PDF

4MW급 고압 인버터 시스템 개발 (Development of 4MW Class High Voltage Inverter System)

  • 박영민;한기준;최세경;정명길;이세현
    • 전력전자학회논문지
    • /
    • 제6권5호
    • /
    • pp.432-437
    • /
    • 2001
  • 본 연구는 새로이 개발된 3.3KV 4MW급의 3레벨 NPC구조의 전압형 대용량 인버터에 대한 것으로 Web 기반의 인버터 정보 관리 시스템(Inverter Information Management System)과 가상 운전 시뮬레이터가 부가된 것이다. 사용된 전동기 제어 알고리즘은 속도 센서 없이 동작 가능한 DTC(Direct Torque Control)기법으로 빠른 응답특성을 갖고 있다. IIMS는 운전상태 모니터링 및 Data 관리기능을 가지고 있으며 가상 운전시뮬레이터는 주 전원을 공급하지 않은 상태에서 시스템의 특성 검증 및 Tuning이 가능하다. 현재 이 제품은 신뢰성 검증을 위해 현장 시험 중에 있다.

  • PDF

Implementation of Cuckoo Search Optimized Firing Scheme in 5-Level Cascaded H-Bridge Multilevel Inverter for Power Quality Improvement

  • Singla, Deepshikha;Sharma, P.R.
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1458-1466
    • /
    • 2019
  • Multilevel inverters have appeared as a successful and utilitarian solution in many power applications. The prime objective of an inverter is to keep the fundamental component of the output voltage of a multilevel inverter at a preferred value. Equally important is the need to keep the harmonic components in the output voltage within stated harmonic limits. Therefore, the basis of this research is to develop a harmonic minimization function that optimizes the switching angles of cascaded H-bridge multilevel inverter. Due to benefits of the Cuckoo Search (CS) algorithm, it is applied to determine the switching angles, which are further used to generate the switching pattern for firing the H-bridges of multilevel inverter. Simulation results are compared with SPWM based firing scheme. The switching frequency for SPWM firing scheme is taken as 200 Hz since the switching losses are increased when switching frequency is high. To validate the ability of Cuckoo Search optimized firing scheme in minimization of harmonics, experimental results obtained from hardware prototype of Five Level Cascaded H-Bridge Multilevel Inverter equipped with a FPGA controller are presented to verify the simulation results.

상보형(相補形) 트랜지스터에 의한 다중(多重) PWM 인버터에 관한 연구 (A Study on The Multi-PWM Inverter by Complementary Transistor)

  • 정연택;이종수;배상준;백종현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.515-517
    • /
    • 1989
  • This PWM inverter are used bridge circuit of two pair complementary transistor at each phase. The operation signals are 3 level PWM wave of W type and M type modulation, Which were obtained from switching time data by switching position calculation of triangular and sine wave. The output voltage waveforms of this inverter have the 5 level phase voltage and the 9 level line voltage of PWM.

  • PDF