• Title/Summary/Keyword: 5 large load

검색결과 669건 처리시간 0.028초

축소형 5KVA 동기발전기 AVR/PSS 강건한 제어정수 설계 및 튜닝 (Design and Tuning of Micro 5KVA Machine's AVR/PSS Robust Control Parameters)

  • 김동준;문영환;김태균;신정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.165-168
    • /
    • 2000
  • This paper describes the guideline of design and tuning of practical Micro 5KVA machine's digital AVR/PSS control parameters by using the computer models and testing on-line AVR step test of laboratory simulator under the no-load or load conditions. The suggested procedures can be also applied to the large scaled machine's AVR/PSS control parameter tuning in KEPCO system.

  • PDF

A Study on Effective Enhancement of Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost

  • Lee Byung Ha;Kim Jung-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.252-259
    • /
    • 2005
  • Various problems such as increase of power loss and voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and restructuring of electric power companies makes the comprehensive management of reactive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of generation cost is derived and it is used for effectively determining the locations of reactive power compensation devices and for enhancing the load power factor appropriately. In addition, voltage variation penalty cost is introduced and integrated costs including voltage variation penalty cost are used for determining the value of load power factor from the point of view of economic investment and voltage regulation. It is shown through application to a large-scale power system that the load power factor can be enhanced effectively using the load power factor sensitivity and the integrated cost.

SIP 메시지 제어 세션에 의한 대용량 분산 프레즌스 서비스 시스템 (A Large Scale Distributed Presence Service System by SIP Message Control Session)

  • 장춘서
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.514-520
    • /
    • 2018
  • 프레즌스 서비스는 사용자의 위치, 온라인/오프라인 여부, 네트워크 접속 방식 등 네트워크 사용자 관련 다양한 정보를 제공하며 모바일 환경에서 각 사용자들이 요구하는 프레즌스 리소스의 수는 크게 증가하고 있다. 따라서 이를 처리하기위하여 프레즌스 서버의 부하를 효율적으로 감소시킬 수 있는 방안이 필요하다. 본 논문에서는 다수의 사용자에 대한 다양한 프레즌스 정보를 제공하는 대용량 분산 프레즌스 서비스 시스템 구현에 메시지 제어 세션을 사용하여 프레즌스 서버의 부하를 효율적으로 분산 처리 할 수 있는 방식을 제안하였다. 본 연구에서는 이를 위하여 사용자 수의 증가에 따른 프레즌스 서버의 부하를 동적으로 복수 개의 서버에게 효율적으로 분산시키기 위한 메시지 제어 세션 구조가 제안되었고 프레즌스 서버 부하 제어를 위한 새로운 프레즌스 정보 데이터 구조가 설계되었다. 이 구조에서 각 프레즌스 서버들은 현재 부하 레벨을 실시간으로 교환하며 사용자 수 변화에 따른 전체 시스템 부하의 변화를 파악하여 각 서버의 부하 레벨이 고르게 유지되도록 분산한다. 제안된 프레즌스 서비스 시스템의 성능은 실험으로 분석하였다. 실험 결과 본 연구에서 제안한 구조의 경우 평균 프레즌스 등록 처리 시간이 기존 방식에 비해 42.6%에서 73.6%까지 감소함을 보여주었고 평균 프레즌스 통지 처리 시간은 37.6%에서 64.8%까지 감소함을 보여주었다.

독립계통에서 유도전동기 부하의 기동시 발전기의 안정적 부하추종에 관한 연구 (Study on Load Following Characteristics of Generators during Start-up of Induction Motor Load in Isolated System)

  • 신호전;허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.80-85
    • /
    • 2015
  • Recently, not only in the Middle East and Southeast Asia but in African area, too, industrial plant construction is being actually done. But unlike in Korea, a lot of them are small-scale isolated industrial plants. And because of the characteristics of industrial plants, induction motors' load forms a large part. The influence of stability resulted from the maneuver and operation of induction motors' load may lead to serious result in the isolated system. This study analyzed it through mathematical modeling on induction motors' maneuver phenomena in the isolated system, realized a case system with the E-TAP program, and simulated load follow performances according to the control variables of a generator inside the isolated system.

운전예비력의 최적운용방식에 관한 연구 (A study on the optimum operation scheme with operating reserve power)

  • 송길영
    • 전기의세계
    • /
    • 제28권5호
    • /
    • pp.49-55
    • /
    • 1979
  • During severe emergencies which result in insufficient generation to meet load, an automatic load shedding method considering the spinning and operating reserve can establish the optimum system operation. This paper presents methods and results of a study on the optimum operating scheme with spinning and operating reserve power in case of outage of large generator units to prevent frequency decay and continue stable operation. This study covers following three parts 1) Analysis of spinning reserve characteristics 2) Determination of operating reserve requirements 3) Development of the optimum load shedding programs By this study the optimum system operating method was recommended for reliable operation of power system.

  • PDF

Derivation of aerosol vertical profiles in Seoul based on O4 measurements using UV scanning spectrometer

  • Lee, Hanlim;Hwang, JungBae;Son, Yoonhee
    • 대한원격탐사학회지
    • /
    • 제29권3호
    • /
    • pp.325-329
    • /
    • 2013
  • This present study describes an application of UV scanning spectrometer $O_4$ data for retrieval of aerosol vertical profiles in Seoul during the measurement period that includes two Asian dust event days. The results show large variations of aerosol load in vertical and temporal scales. Large variations in aerosol were observed at 1 km in height during the daytime in the measurement period when the Asian dust events took place. The aerosol load, however, was found to be largest at the surface compared to those retrieved at the higher atmospheric layers. The results also clearly identified the diurnal patterns of aerosol vertical distributions. The aerosol load was high in the morning and noon whereas it was low in the afternoon. This study demonstrates that UV scanning spectrometer observations of the oxygen dimer can serve as a potential method for determination of atmospheric aerosol vertical distributions and optical properties.

직접해법에 의한 공기 윤활 틸팅 패드 저어널 베어링의 윤활 해석에 관한 연구

  • 김인식;황명
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 춘계학술대회 논문집
    • /
    • pp.121-126
    • /
    • 1993
  • Tiling pad journal bearing that has high stability is analyzed about air-lubricated bearing that is usually used to need high precision by using the Direct analysis. The pressure that supports the shaft is occured by the differences between the shaft and pads radii of curvatures. So the characteristics of load capacity for their variable values is important. In this paper the load capacity is compared with some the eccentricity ratio values of0.1, 0.2, 0.5, 0.8. The large load capacity comes from large eccentricity ratio, highbearing number and high preload. But if the preload become high too much, then the shaft makes contact with pads.

로드셀을 이용한 STS304 박판용접부의 구속력 측정에 관한 연구 (A Study on the Measurement of Constraint Force of STS304 Thin plate Using the Load Cell)

  • 고준빈;최원두;이성구;박성두;이영호
    • Journal of Welding and Joining
    • /
    • 제19권5호
    • /
    • pp.548-554
    • /
    • 2001
  • The restraint force is required an accurate measurement and analysis to protect weldment from residual stress. Also, this residual stress caused by clacks in weldments are often observed in the weldments of large size nozzles or radial tanks after welding. This paper is preformed on the study of evaluation of welding restraint forces using load cell with STS thin plate which are using pressure vessel steel in the industry field. As a result of this study, as the welding currents are higher and the welding speeds are more slowly, the magnitude of restraint force in process of the flat plate welding hows to be more large. Also, the temperature in process of melting is increasingly rising, then the restraint forces exhibit the compressive forces, whereas the restraint forces during cooling represent extensional force.

  • PDF

디젤기관 실린더 라이너 변형에 대한 유한요소 해석 (A Finite Element Analysis on Cylinder Liner Deformation of a Diesel Engine )

  • 안상호
    • 자동차안전학회지
    • /
    • 제6권1호
    • /
    • pp.33-40
    • /
    • 2014
  • In this study the cylinder liner deformation which is one of the most influencing factors in a diesel engine oil consumption was performed by the finite element analysis on the basic designed structure consisting of the cylinder block, head and liners under the conditions of assembly, thermal and gas loads. Compared with a large number of other cylinder blocks showing remarkable harmonic orders of the liner distortion, results are excellent. Namely. the higher harmonic order amplitudes of the radial liner deformation amount to 1 ~ 2㎛ maximally. The main reason lies in the relatively large wall thickness of the liner which amounts to 8.2% of the bore diameter. Besides, a very stiff and symmetrical cylinder block design in combination with a bolt force introduction approximately 1.5mm below the block top deck have a further share on these results. Therefore excellent low oil consumption can be expected.

압축하중시 PET병의 변형특성에 관한 수치해석 및 실험적 연구 (Numerical analysis and Experiment to Determine Deformation Characteristics of PET Bottle under Compressive Load)

  • 조승현;권창오;박균명;고영배
    • 한국생산제조학회지
    • /
    • 제23권1호
    • /
    • pp.83-86
    • /
    • 2014
  • Many have been performed to decrease the thickness of polyethylene terephthalate (PET) bottles to reduce the manufacturing cost. However, it is difficult to guarantee the mechanical strength under top-loading after decreasing the thickness. This paper investigates the large deformation characteristics of a PET bottle under a compressive load using experimental and finite element analysis (FEA) data. A round 1.65-L bottle is analyzed under a compressive velocity of 5 mm/min with a maximum load of 9,800 N in experiments. The arc length method is used in a nonlinear FEA to understand the buckling phenomenon of the PET bottle. From the analyzed results, a recommendation is made to restrict the top loading to less than 1,208 N, because the first buckling phenomenon occurred at a load of 1,208 N.