• Title/Summary/Keyword: 4f moment

Search Result 88, Processing Time 0.027 seconds

Moment Analysis (MA) of Lysozyme in Cation Exchange High Performance Liquid Chromatography (HPLC) (양이온교환 고성능액체크로마토그래피에서 라이소자임의 모멘트 분석)

  • Ko, Kwan Young;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.487-493
    • /
    • 2016
  • The moment analysis of lysozyme was implemented using chromatograms that were obtained from weak cation exchange column in high performance liquid chromatography system. Three elution sodium phosphate buffers containing 1.0, 0.75, 0.5M sodium chloride were used. Experiments were conducted by varying flow rate, elution sodium chloride concentration, and lysozyme solute concentration. The general rate (GR) model was employed to calculate the first moment and the second moment. By plotting $L/u_0$ vs. $({\mu}_1-t_0)/(1-{\varepsilon}_e)(1-{\varepsilon}_i)$] equilibrium constants (K) were obtained from first moment analysis. Intra-particle diffusivity was obtained from theoretical plate number data. Based on the results of moment analysis, van Deemter plots were drawn in order to investigate the contributions of $H_{ax}$, $H_f$, and $H_d$ to total Height Equivalent to a Theoretical Plate (HETP, $H_{total}$). The effect of intra-particle diffusion ($H_d$) was the most dominant factor contributing to HETP while external mass transfer ($H_f$) was negligible factor.

Theoretical Analysis of Dipole Moment Derivatives in Fluoromethanes. (III) CH$_3$F and CF$_4$

  • Kim, Kwan;Park, Cheol-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.3
    • /
    • pp.174-179
    • /
    • 1987
  • The results of an ab initio (6-31G) molecular orbital calculations of the dipole moment derivatives and gas phase IR intensities in $CH_3F$ and $CF_4$ are reported. The results are compared with corresponding values obtained from a CNDO calculation. We have also analyzed the theoretical polar tensors into the charge, charge flux, and overlap contributions. The effective term charges of hydrogen atom appeared to be transferable among the fluoromethane molecules.

A Study on the ALFD Design of Rolled Beams (압연형교의 ALFD설계에 관한 연구)

  • Chung, Kyung-Hee;Kim, Jin-Sung;Yang, Seung-Ie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.91-97
    • /
    • 2003
  • The maximum moment may occur at interior supports of continuous bridges. If the bigger moment is applied on them, a local yielding at interior supports may occur. They may show plastic behaviors, and the moment will be redistributed. The strength design, L.F.D., redistributes 10% of the negative moment which is obtained from the elastic analysis. However, A.L.F.D method computes the moment which is redistributed. This moment is called automoment. The moment-rotation curve is needed to find automoment. In this paper moment-rotation curve for compact sections suggested from AASHTO Guide Specifications is used to find automoment. Based on A.L.F.D. limit states specification method, a three-span continuous bridge is designed.

Seismic Performance Evaluation of Steel Moment Frames in Korea Using Nonlinear Dynamic Analysis (비선형동적해석을 통한 국내 철골 모멘트골조의 내진성능 평가)

  • Kim, Tae-Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • Domestic steel moment resisting frames were designed in accordance with the former KBC2005 and the current KBC2009, and then their seismic performance was evaluated in accordance with FEMA355F by utilizing nonlinear dynamic analysis. The results from the procedure in FEMA355F were different with those from the capacity spectrum method utilizing nonlinear static push-over analysis. In particular, the domestic steel moment resisting frames have a weak panel zone, so their behavior can be estimated more precisely by nonlinear dynamic analysis. The domestic steel moment resisting frames satisfied the performance goal if located at a site class $S_B$ or $S_C$, regardless of the story number and the response modification factor. However, if they are located at a site class $S_D$ or $S_E$, performance goal satisfaction cannot be guaranteed. No matter what standard is used for the design, KBC2005 or KBC2009, the domestic steel moment resisting frames may possess satisfactory seismic performance if the site condition is relatively good.

Factors affecting force system of orthodontic loop spring (교정용 loop 스프링의 force system에 영향을 주는 요소)

  • Choy, Kwang-Chul;Kim, Kyung-Ho;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.511-519
    • /
    • 1999
  • The shape of orthodontic retraction spring was varied and force system of each case was obtained using numerical analysis and verified with spring tester. The factors for obtaining biomechanically efficient spring under anatomic limitation were suggested as follows. 1. M/F ratio increases and L/D rate decreases as loop height increases. 2. M/F ratio increases and L/D rate decreases as incorporating more wire above minimum bending moment area. 3. M/F ratio decreases and L/D rate decrease as incorporating more wire below minimum bending moment area. 4. M/F ratio can not be greater than spring height no matter how much wire is incorporated at the apex of the loop. 5. Additional moment is necessary to obtain enough M/F ratio for translation under anatomical limitation. 6. Additional moment should be incorporated at every pah of the spring because M/F ratio and L/D rate decreases as horizontal spring length increases. 7. Material, cross section, and shape of the spring influence L/D rate, whereas M/F ratio is influenced by the shape of the spring independent from material and cross section.

  • PDF

5-D.O.F. Force/moment Sensor using Optical Intensity Modulation in MR-field (MR 환경에서 사용을 위한 5자유도 광학식 힘센서)

  • Kim, Min Gyu;Lee, Dong Hyeok;Cho, Nahm Gyoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.520-528
    • /
    • 2013
  • A 20 mm diameter of small 5-D.O.F. force sensor has been developed for applications in MR-field Optical intensity modulation was adopted for transducing to miniaturize the sensor structure. For its accurate sensing of 5-D.O.F. force/moment, the elastic detecting module was designed to respond independently to each force or moment component. And for small size, two optical transducing modules of 2-D.O.F. and 3-D.O.F. were designed and integrated with the detecting module where optical fibers were arranged in parallel to make the sensor small. It is confirmed by calibration test that the detecting modules deforms linearly and independently to the input force. The results of evaluating test show that the range and resolution of forces are ${\pm}4$ N and 0.94~7.1 mN and the range and resolution of moments are ${\pm}120N{\cdot}mm$ and $0.023{\sim}0.034N{\cdot}mm$.

A Study on the Synthesis of Korean Speech by Formant VOCODER (포르만트 VOCODER에 의한 한국어 음성합성에 관한 연구)

  • 허강인;이대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.14 no.6
    • /
    • pp.699-712
    • /
    • 1989
  • This paper describes a method of Korean speech synhes is using format VOCODER. The parameters of speech synthes is are a follows, 1) format F1, F2, and F3 by spectrum moment method and F4, F5 using the length of vocal tract. 2) pitch frequencies obtained by optimu, Comb method using AMDF. 3) short time average energy and short time mean amplitude. 4) The decision method of bandwidth reportd by Fant. 5) voicde/unvoiced discrimination using zerocrossing. 6) excitation wave reported by Rosenberg. 7) gaussian white noise. Synthesis results are in fairly good agreement with original speech.

  • PDF

Effect of labiolingual inclination of a maxillary central incisor and surrounding alveolar bone loss on periodontal stress: A finite element analysis

  • Choi, Sung-Hwan;Kim, Young-Hoon;Lee, Kee-Joon;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.155-162
    • /
    • 2016
  • Objective: The aim of this study was to investigate whether labial tooth inclination and alveolar bone loss affect the moment per unit of force ($M_t/F$) in controlled tipping and consequent stresses on the periodontal ligament (PDL). Methods: Three-dimensional models (n = 20) of maxillary central incisors were created with different labial inclinations ($5^{\circ}$, $10^{\circ}$, $15^{\circ}$, and $20^{\circ}$) and different amounts of alveolar bone loss (0, 2, 4, and 6 mm). The $M_t/F$ necessary for controlled tipping ($M_t/F_{cont}$) and the principal stresses on the PDL were calculated for each model separately in a finite element analysis. Results: As labial inclination increased, $M_t/F_{cont}$ and the length of the moment arm decreased. In contrast, increased alveolar bone loss caused increases in $M_t/F_{cont}$ and the length of the moment arm. When $M_t/F$ was near $M_t/F_{cont}$, increases in Mt/F caused compressive stresses to move from a predominantly labial apical region to a palatal apical position, and tensile stresses in the labial area moved from a cervical position to a mid-root position. Although controlled tipping was applied to the incisors, increases in alveolar bone loss and labial tooth inclination caused increases in maximum compressive and tensile stresses at the root apices. Conclusions: Increases in alveolar bone loss and labial tooth inclination caused increases in stresses that might cause root resorption at the root apex, despite the application of controlled tipping to the incisors.

Effect of axial load on flexural behaviour of cyclically loaded RC columns

  • Au, F.T.K.;Bai, Z.Z.
    • Computers and Concrete
    • /
    • v.3 no.4
    • /
    • pp.261-284
    • /
    • 2006
  • The flexural behaviour of symmetrically reinforced concrete (RC) columns cast of normal- and high-strength concrete under both monotonic and cyclic loading is studied based on an analytical procedure, which employs the actual stress-strain curves and takes into account the stress-path dependence of concrete and steel reinforcement. The analysis is particularly extended into the post-peak stage with large inelastic deformation at various applied axial load level. The effect of axial load on their complete flexural behaviour is then identified based on the results obtained. The axial load is found to have fairly large effect on the flexural behaviour of RC columns under both monotonic and cyclic loading. Such effects are discussed through examination of various aspects including the moment-curvature relationship, moment capacity, flexural ductility, variation of neutral axis depth and steel stress.