• Title/Summary/Keyword: 4M technique

Search Result 2,648, Processing Time 0.033 seconds

Effective Detection Technique of Near Miss using 4M Risk Assesment Methodology (4M 위험성평가 기법을 이용한 앗차사고의 효과적인 발굴기법)

  • Seo, Seong-Hwa;Weon, Jong-Il;Woo, Heung-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.164-170
    • /
    • 2012
  • In this study, a new technique for detecting near miss using 4M risk assessment method is suggested. Until now, the safety education with instances of near miss has just been progressed in most industrial settings, without any systematic guideline. By menas of appling 4M risk assessment method, the organized technique, which could effectively manage the fundamental prevention of industrial accident in advance, is developed. The organized technique of near miss-management suggested in this study will take an effective role in basically expanding the application of risk assessment method, as well as in contributing the activity of zero-accident as a safety guideline in hazardous workshops.

16-state and 320state multidimensional PSK trellis coding scheme using M-ary orthogonal modulation with a frequency-recuse technique (주파수 재 사용 기술을 이용한 M-ary 직교 16-State 및 32-State 다차원 PSK 트렐리스코딩)

  • 김해근;김진태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.8
    • /
    • pp.2003-2012
    • /
    • 1996
  • The 16- and 32-state Trellis-coded M-ary 4-dimensional (4-D) orthogonal modulation scheme with a frequency-reuse technique have been investigated. Here, 5 coded bits form a rate 4/5 convolutional encoder provide 32 possible symbols. Then the signals are mapped by a M-ary 4-D orthogonal modulator, where each signal has equal energy and is PSK modulated. In the M-ary 4-D modulator, we have employed the vectors which is derived by the optimization technique of signal waveforms in a 4-D sphere. This technique is usedin maximizing the minimum Euclidean distance between a set of signal poits on a multidimensional sphere. By combinig trellis coding with M-ary 4-D modulation and proper set-partitioning, we have obtained a considerable impeovement in the free minimum distance of the system over an AWGN channel. The 16-state scheme obtains coding gains up to 5.5 dB over the uncoded two-independent QPSK scheme and 2.5 dB over the two-independent 2-D TCM scheme. And, the 32-state scheme obtains coding gains up to 6.4 dB over the uncoded two-independent QPSK schemeand 3.4 dB over the two-independent 2-D TCM scheme.

  • PDF

Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique (복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석)

  • Lee, Bo-Woo;Park, Myung-Cheol;Lee, Jin-Hoi;Kim, Ki-Jin;Bae, Seok-Hwan
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.385-390
    • /
    • 2014
  • This research is conducted to identify whether an m-DIXON technique which is useful for an abdomen MRI examination compared with an existing e-THRIVE technique is a clinically useful or not. There was evaluated quantitative and qualitative to 84 subjects who had abdomen MRI exam due to their liver disease were conducted during a period from September in 2013 to February in 2014. First of all the quantitative evaluation, the m-DIXON technique's SNR was $90.42{\pm}16.90$ and the e-THRIVE technique was $60.42{\pm}11.54$ and the m-DIXON technique's CNR was $52.38{\pm}22.58$ and the e-THRIVE technique was $46.31{\pm}20.25$. Secondly in the qualitative evaluation, the m-DIXON technique's image quality was $4.06{\pm}0.34$, a artifact was $3.64{\pm}0.22$, and fat suppression was $4.16{\pm}0.15$, the e-THRIVE technique's image quality was $3.14{\pm}0.35$, a artifact was $3.06{\pm}0.38$, fat suppression was $3.14{\pm}0.30$. In conclusion, m-DIXON technique for abdomen MRI examination showed superiority over both SNR as a quantitative anaylsis, CNR and a qualitative analysis.

An Efficient Global Motion Estimation based on Robust Estimator

  • Joo, Jae-Hwan;Choe, Yoon-Sik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.408-412
    • /
    • 2009
  • In this paper, a new efficient algorithm for global motion estimation is proposed. This algorithm uses a previous 4-parameter model based global motion estimation algorithm and M-estimator for improving the accuracy and robustness of the estimate. The first algorithm uses the block based motion vector fields and which generates a coarse global motion parameters. And second algorithm is M-estimator technique for getting precise global motion parameters. This technique does not increase the computational complexity significantly, while providing good results in terms of estimation accuracy. In this work, an initial estimation for the global motion parameters is obtained using simple 4-parameter global motion estimation approach. The parameters are then refined using M-estimator technique. This combined algorithm shows significant reduction in mean compensation error and shows performance improvement over simple 4-parameter global motion estimation approach.

  • PDF

Evaluation of Autoligation Technique for Castration in Small Breed Dogs

  • Kim, Jong-In;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.75-81
    • /
    • 2020
  • The objective of the present study was to evaluate the effectiveness of autoligation techniques for castrating healthy male small breed dogs. Forty dogs were divided into four groups, with 10 in each group, based on maturity and the surgical technique used: 1) immature dogs aged less than 1 year, with autoligation of the spermatic cord via a scrotal approach (SAL) as the surgical technique (SAL-IM); 2) mature dogs aged 1 year or older, with the same SAL surgical technique (SAL-M); 3) immature dogs aged less than 1 year, with double ligation of the spermatic cord with an absorbable suture via a prescrotal approach (PDL) as the surgical technique (PDL-IM); and 4) mature dogs aged 1 year or older, with the same PDL surgical technique (PDL-M). The effectiveness of the surgical technique was evaluated by comparing the operating time and complications between these four groups. The significant decreases in operating times were found in SAL-IM and SAL-M compared with those of PDL-IM and PDL-M (p < 0.01 and p < 0.01). Regardless of maturity, the SAL surgical technique reduced operating time by approximately 69.5% compared with the PDL surgical technique. When the complication severities were scored, the results showed no significant differences among the four group. The autoligation technique for castration in healthy male small breed dogs is considered to be effective because the operating time consuming is less than conventional techniques.

Performance Analysis of Trellis Coded OFDM/M-ary PSK Systems in the presence of tarrier Frequency Offset (반송파 주파수 오프셋의 존재하에서 Trellis Coded OFDM/M-ary PSK 시스템의 성능 분석)

  • 조성언;박기식;오원근
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.4
    • /
    • pp.684-691
    • /
    • 2001
  • In this paper, the BER performance of OFDM/M-ary PSK systems is analyzed with considering carrier-frequency offset and TCM technique, which encodes and modulations simultaneously, is adopted to OFDWM-ary PSK systems for compensation of performance degradation according to carrier-frequency offset. As a result of analysis, the error performance of OFDM/M-ary PSK systems is degraded as the frequency offset is increased. And the frequency offset should be below 0.025 in order to achieve $BER= 10^{-3}$ with $E_b/N_o$ of 10 dB. Especially, when the TCM technique is adopted to OFDM/M-ary PSK systems, the performance improvement of about 4 dB is obtained in terms of $E_b/N_o$.

  • PDF

Synthesis of Mullite Powders by the Geopolymer Technique (Geopolymer Technique에 의한 Mullite 분말의 합성)

  • Son, Se-Gu;Lee, Ji-Hyeon;Lee, Jeong-Mi;Kim, Young-Do
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.5
    • /
    • pp.303-308
    • /
    • 2008
  • Mullite precursors were synthesized with aluminosilicate gels from mixture of aluminum nitrate and sodium orthosilicate by the geopolymer technique at ambient temperature. Then, the gel was heat-treated in air up to $1200^{\circ}C$ at intervals of $100^{\circ}C$. Raw and heat-treated gels were characterized by TG-DTA, XRD, FTIR, $^{29}Si$ MAS-NMR, TEM. The result to examine the crystallization of behavior though DTA, the synthesized precursors were crystallized in the temperature range from $950^{\circ}C$ to $1050^{\circ}C$. The XRD results showed that the gel compositions were begun to crystallize at various temperature. Also, it was found that the precursors of M-4 begun to crystallize at about $950^{\circ}C$. The M-4 XRD peaks were characterized better than $M-1{\sim}M-3$ at $1000^{\circ}C$. The formation temperature of mullite in this study is much lower than that of previous sol-gel methods, which crystallized at up of $1200^{\circ}C$. TEM investigations revealed that the sample with 10 nm particle size was obtained via heat-treated at $1000^{\circ}C$ for M-4.

MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES (가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화)

  • Han, Seung-Ryul;Min, Kyung-San;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

Characteristics of titanium polarization curve and formation of nanomesh by electrochemical method (전기화학적 방법에 의한 타이타늄 분극특성 및 나노메쉬 형성)

  • Park, Jin-Seo;Kim, Bu-Sub
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.79-84
    • /
    • 2016
  • Purpose: The aim of this study was to make nanomesh on the surface of titanium by potentiostatic technique which was done at the suitable potential level. Methods: In order to find the suitable potential level, use a $25^{\circ}C$ NaCl, NaOH and NH4F solution of 1 M and 5 M as supporting electrolyte, working electrode(positive potential) was contact to the titanium specimen and counter electrode(negative potential) was contact to the Pt substrate. At the transpassive potential which was observed by potentiostatic technique, potentiostatic technique was done for 2hours. Results: As a result, 1 M NaOH solution was suitable as a supporting electrolyte, potentiostatic technique used a $25^{\circ}C$ NaOH solution of 1 M for 2hours, nanomesh was formed. Conclusion: The potentiostatic technique was used $25^{\circ}C$ NaOH solution of 1 M and 5 M as supporting electrolyte for 2hours. Nanomesh was built more uniform and fine in 1 M NaOH solution than 5 M NaOH solution.

Design of Mixer using Neutralization Technique (Neutralization을 이용한 주파수 변환기 설계)

  • Choi, Moon-Ho;Choi, Won-Ho;Kim, Yeong-Seuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.311-320
    • /
    • 2008
  • In this paper, a 2.4 GHz low-voltage CMOS double-balanced down-conversion mixer using neutralization technique has been proposed and verified by circuit simulations and measurements. The grounded source structure was used for low-voltage operation. The neutralization technique was used to improve a conversion gain. The proposed mixer is fabricated in $0.25{\mu}m$ CMOS process for a 2.4 GHz wireless receiver. The mixer consumes 1.94 mW and gives conversion gain of 5.66 dB, input IP3 of 0.7 dBm and P1dB of -11.2 dBm at 1.5 V power supply. Measured results for the designed mixer show improved conversion gain of 2.86 dB over conventional mixer of grounded source structure.