• 제목/요약/키워드: 4D phantom

검색결과 285건 처리시간 0.034초

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.

3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰 (A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient)

  • 서정남;나종억;배선명;정동민;윤인하;배재범;곽정원;백금문
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.53-60
    • /
    • 2015
  • 목 적 : 본 연구는 3D 프린터를 이용하여 전립샘부위 팬텀을 제작하고 생체내선량측정(In-vivo dosimetry)을 통해 그 유용성을 평가하고자 한다. 대상 및 방법 : 전립샘암 환자의 3차원 치료체적을 바탕으로 3D 프린터(3D EDISON+, Lokit, KOREA)를 이용하여 전립샘과 직장의 체적을 동일하게 모사한 팬텀을 제작하고, 컴퓨터단층촬영(Lightspeed CT, GE, USA)을 통해 팬텀영상을 획득하였다. 전립샘암 환자의 체적과 팬텀의 체적을 비교 한 후, 전산화치료계획시스템(Eclipse version 10.0, Varian, USA)을 이용하여 치료계획을 설계하였다. 팬텀 내 측정지점인 방광(Bladder), 전립샘(Prostate), 직장 위벽(Rectal anterior wall), 직장 아래벽(Rectal posterior wall)의 임의의 지점에 모스펫검출기(Metal OXIDE Silicon Field Effect Transistor, MOSFET)를 위치시켜 선량 측정값과 치료계획을 비교분석 하였다. 결 과 : 전립샘과 직장풍선의 환자체적은 각각 30.61 cc, 52.19 cc 이고, 팬텀체적은 31.12 cc, 53.52 cc로 각 체적의 차이는 3% 미만으로 확인되었다. 모스펫검출기의 정밀도는 3%이내로 측정되었고 선량의 변화에 따라 상관계수 R2 = 0.99 ~ 1.00 의 선형성을 보였다. 네 곳의 측정 지점을 치료계획된 선량과 비교한 결과 방광 1.4%, 전립샘 2.6%, 직장 위벽 3.7%, 직장 아래벽 1.5%로 나타났고 모스펫검출기의 정밀도를 고려한 선량측정의 정확성은 5% 이내로 평가되었다. 결 론 : 본 실험을 통해 3D 프린터를 이용하여 제작한 전립샘 부위 팬텀은 체적의 차이 3% 미만으로, 인체를 모사하는데 효과적으로 사용될 수 있음을 확인하였다. 제작된 팬텀을 이용한 생체내선량측정은 모스펫검출기의 정밀도를 고려하더라도 방광, 전립샘, 직장 위벽, 직장 아래벽의 모든 측정점에서 5% 이내의 정확도로 수행 할 수 있었다. 따라서 3D 프린트를 이용해 제작된 전립샘 부위 팬텀은 생체선량측정을 하는데 있어 매우 유용하였으며 향후 환자에게 직접 적용하기 어려운 부위를 팬텀으로 대체 제작하여 생체내선량측정이 가능할 것으로 사료된다.

  • PDF

PET 검사에서 CT 장비의 차이에 따른 PET/CT의 SUV 비교 평가 (The Comparison Evaluation of SUV Using Different CT Devices in PET/CT Scans)

  • 김우현;고현수;이정은;김호성;류재광;정우영
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.10-18
    • /
    • 2014
  • 암에 대한 진료 및 치료 효과 판정 등에 유용한 PET 검사가 증가되면서 추적검사 시 SUV의 정확한 비교를 위해 EANM 등에서는 동일한 장비에서 검사를 시행하는 것을 권고하고 있어 동일한 기종의 PET/CT 활용에 대한 관심이 커지고 있다. 하지만 병원의 환경상 여건이 허락되지 않는 경우가 많아 정확한 SUV 비교를 위한 Factor 개발, 장비간 호환 등의 방안을 마련하는데 관심이 높아지고 있다. 이런 관점에서 기종이 다른 3대의 PET/CT 장비를 대상으로 SUV를 평가하여 장비간 호환성이 가능한지 실험해 보았다. Discovery 690, Discovery 690Elite, Discovery 710 장비를 대상으로 ACR phantom, NEMA IEC Body phantom, SNM Chest phantom, $^{68}Ge$-cylinder phantom에 대한 SUV를 측정하여 장비간 비교를 시행하였다. 장비 별 SUVmean과 $SUV_{max}$를 측정하여 비교해 본 결과, $SUV_{mean}$의 경우 각 phantom 별로 장비간 차이는 최대 3.61%, 최소 0.19%였고 $SUV_{max}$는 장비 별로 최대 4.11%, 최소 0.03% 정도 차이가 발생하였다. 제조사에서 권고하는 장비간 SUV 허용 범위는 5%이며 실험에 사용된 3대의 PET/CT 장비간 SUV 차이는 이에 포함된다. 이는 CT 기종의 차이에 따른 SUV의 변화는 크지 않음을 유추할 수 있다. 병원마다 동일한 장비를 여러 대 구입하기에는 현실적인 어려움이 있으므로 기종이 다른 PET/CT 장비의 SUV가 허용 가능한 범위 내에 있는 장비를 활용한다면 동일한 장비 사용을 권고하는 추적검사의 경우 예약 일정 변경 등의 검사 효율성이 증가되고 정량평가의 정확도를 높여 줄 것이다.

  • PDF

폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발 (Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT)

  • 윤경준;곽정원;조병철;송시열;이상욱;안승도;남상희
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.100-109
    • /
    • 2014
  • 정위신체방사선치료(SBRT)에서 환자의 호흡에 대한 정확한 치료위치의 확보는 필수적으로 고려되어야 하며 그 정확성에 관련하여 많은 연구들이 진행되어왔다. 본 연구에서는 실제 호흡에 의한 움직임과 실제 환자 폐의 형태를 고려한 팬텀실험으로 실제 치료에서 일어나는 임상적 상황을 모사함으로 호흡 동조 부피적조절회전 방사선치료(Volumeric Modulated Arc Therapy, VMAT) 기법을 이용한 폐부 SBRT의 정확성을 분석하는 방법을 제시하고자 하였다. SBRT을 받은 폐암 환자의 CT 영상을 기반으로 3D 프린터를 이용하여 치료부위와 유사하게 폐 팬텀을 제작하였고 환자 호흡과 동일하게 움직임을 재현할 수 있도록 $QUASAR^{TM}$ 호흡 동조 구동 팬텀(Modus Medical Devices, London, Canada)에 장착하여 호흡동조 VMAT에서의 2차원 선량 분포를 평가할 수 있는 시스템을 구축하였다. 폐 팬텀은 종양부위를 중심으로 2등분하여 EBT3 필름을 삽입하고 선량분포를 측정할 수 있도록 제작되었다. 비균질 조건에서의 선량계산의 정확성을 확인하기 위하여 균질한 플라스틱 팬텀과 제작된 비균질 폐 팬텀에서 Analytical Anisotropic Algorithm (AAA)와 AcurosXB (AXB) 두가지 알고리즘으로 선량계산을 하여 비교, 분석하였다. 움직임에 대한 치료의 정확성을 평가하기 위하여 호흡동조와 비 호흡동조의 경우, 그리고 움직임이 없는 조건에서 선량분포를 취득하여 치료계획 선량에 대한 감마지표를 분석하였다. 치료부위 GTV에서의 CT number는 실제 환자의 경우 78 HU를 나타내었고 모사된 폐 팬텀의 경우 92 HU를 나타내었다. 팬텀 내 폐 조직부분은 3D프린터로 적층하는 과정에서 격자구조의 형태를 이용하여 구현하였다. 측정된 필름선량은 AAA 알고리즘을 이용한 치료계획 선량에 대하여 움직이는 팬텀에서 호흡동조의 유무에 따라 3%/3 mm 감마지표 조건하에서 각각 88%와 78%의 감마합격률을 나타내었으며, 움직임이 없는 경우 95% 이상의 감마합격률을 보였다. AXB 알고리즘을 적용하였을 경우에는 모든 경우에서 98% 이상의 합격률을 나타내었다. 균질한 플라스틱 팬텀에 대하여 측정하였을 때 두가지 선량계산 알고리즘을 포함한 모든 조건에서 99% 이상의 감마합격률을 나타내었다. 선택된 환자의 호흡 진폭이 비교적 작고 inhale보다는 exhale에 더 오래 머무르는 호흡패턴 때문에 3%/3 mm 감마 기준에서는 호흡에 따른 차이가 거의 나타나지 않은 것으로 이해되었다. 선량계산의 정확성에서는 AAA 알고리즘을 적용하였을 때보다 AXB 알고리즘을 적용하였을 때가 균질과 비균질 환경에서의 선량 분포에 따른 감마 합격률의 차이가 적게 나타남을 확인 할 수 있었다. 본 논문에서는 환자와 유사하게 제작된 폐 팬텀에 실제 환자 호흡 패턴을 연동함으로 새로운 4D 치료선량 분포 검증 방법을 제시하였고 보다 사실적인 선량분포를 반영한 개별 환자 치료의 정확성 검증이 가능할 것으로 평가되었다.

심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교 (The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT)

  • 송재혁;김경식;이동훈;김성환;박장원
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.87-92
    • /
    • 2015
  • SPECT에서 Uniformity는 균일한 방사능을 갖는 선원에 대하여 균일한 영상을 제공하는 능력이다. 영상에서 다양한 이유로 불균일이 발생하게 되고, 불균일은 artifacts를 발생시켜 임상적으로 진단하는데 영향을 줄 수 있다. Uniformity correction map은 검사에 사용되는 방사성 동위원소를 이용하여 영상에서 Uniformity의 변동폭을 최소화 시켜주는 역할을 한다. 본원에서 시행되고 있는 $^{201}Tl$을 이용한 심근 SPECT에서는 $^{99m}Tc$으로 기본 설정되어 있는 Uniformity correction map을 사용하고 있으며, 이에 따라 본 연구에서는 $^{201}Tl$$^{99m}Tc$ 두 가지 핵종으로 Uniformity correction map을 각각 설정하였을 때 영상의 질에 차이가 있는지 비교 분석하고, 영상의 질을 최적화 할 수 있는 방법에 대하여 모색해 보고자 한다. 장비는 GE Ventri Gamma camera, Flood phantom, Jaszczak ECT phantom을 이용하였다. 실험에 앞서 Collimator를 제거한 상태에서 Detector 표면 중심으로부터 2.5 m 떨어진 지점에 1 cc 주사기에 $^{99m}Tc$ 25.9 Mbq, $^{201}Tl$ 14.8 Mbq의 방사성 동위원소를 주입한 point source를 이용하여 장비사에서 권고하는 $6{\times}10^7count$$^{99m}Tc$$^{201}Tl$ 각각의 방사성 동위원소로 Uniformity Mapping을 실시하였다. Flood phantom에는 $^{201}Tl$ 21.3 kBq/mL, Jaszczak ECT phantom에는 $^{201}Tl$ 33.4 kBq/mL를 주입하여 phantom을 제작하였다. Flood Phantom으로 획득된 데이터는 Xeleris ver 2.05 프로그램을 이용하여 Integral uniformity, Differential uniformity을 두 가지 항목에 대하여 분석하였다. Jaszczak ECT Phantom으로 획득된 데이터를 본원에서 자체 개발한 Interactive Data Language 프로그램에 입력하여 Integral uniformity, Contrast, Coefficient of variation, Spatial Resolution을 4가지 항목에 대하여 분석하였다. Flood phantom test 에서는 $^{99m}Tc$에서의 Flood I.U값은 3.6%, Flood D.U값은 3.0%으로 나타났고, $^{201}Tl$ Flood I.U값은 3.8%, Flood D.U값은 2.1%으로 나타났다. 이를 통해 $^{201}Tl$으로 Uniformity correction map을 설정하였을 때, Flood I.U값은 감소하였으나 Flood D.U은 향상되어 Flood 영상에서는 크게 영상의 질이 개선되었는지는 알 수 없었다. 반면 Jaszczak ECT Phantom test에서는 $^{99m}Tc$에서의 SPECT I.U값은 13.99%, Coefficient of variation값은 4.89%, contrast값은 0.69, $^{201}Tl$에서의 SPECT I.U값은 11.37%, Coefficient of variation값은 4.79%, contrast값은 0.78로 나타났으며, 육안 분석을 실시한 Spatial Resolution 항목에서는 육안으로 큰 차이를 보이지 않았다. 이를 통해 $^{201}Tl$으로 Uniformity correction map을 설정하였을 때, Spatial Resolution 을 제외한 SPECT I.U, Coefficient of variation, Contrast 세 항목에서 각각 18%, 2%, 13%의 향상된 수치를 보였다는 점에서 영상의 질이 개선되었음을 알 수 있었다. Uniformity correction map이 영상의 질을 크게 좌우할 수 없으나, 개선의 효과를 가져다 준다는 점에서 임상적으로 진단에 영향을 주는지 또한 다른 검사에서 또 다른 방사성 동위원소로 Uniformity correction map을 설정했을 경우 영상의 질을 개선시킬 수 있는지에 관하여 추가적인 연구가 필요할 것으로 사료된다.

  • PDF

팬텀투과계수와 유효조사면 개념을 이용한 종양선량 확인에 관한 연구 (IN-VIVO DOSE RECONSTRUCT10N USING A TRANSMISION FACTOR AND AN EFFECTIVE FIELD CONCEPT)

  • 김유현;여인환;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권1호
    • /
    • pp.63-71
    • /
    • 2002
  • The aim of this study Is to develop a simple and fast method which computes in-vivo doses from transmission doses measured doting patient treatment using an ionization chamber. Energy fluence and the dose that reach the chamber positioned behind the patient is modified by three factors: patient attenuation, inverse square attenuation. and scattering. We adopted a straightforward empirical approach using a phantom transmission factor (PTF) which accounts for the contribution from all three factors. It was done as follows. First of all, the phantom transmission factor was measured as a simple ratio of the chamber reading measured with and without a homogeneous phantom in the radiation beam according to various field sizes($r_p$), phantom to chamber distance($d_g$) and phantom thickness($T_p$). Secondly, we used the concept of effective field to the cases with inhomogeneous phantom (patients) and irregular fields. The effective field size is calculated by finding the field size that produces the same value of PTF to that for the irregular field and/or inhomogeneous phantom. The hypothesis is that the presence of inhomogeneity and irregular field can be accommodated to a certain extent by altering the field size. Thirdly, the center dose at the prescription depth can be computed using the new TMR($r_{p,eff}$) and Sp($r_{p,eff}$) from the effective field size. After that, when TMR(d, $r_{p,eff}$) and SP($r_{p,eff}$) are acquired. the tumor dose is as follows. $$D_{center}=D_t/PTF(d_g,\;T_p){\times}(\frac{SCD}{SAD})^2{\times}BSF(r_o){\times}S_p(r_{p,eff}){\times}TMR(d,\;r_{p,eff})$$ To make certain the accuracy of this method, we checked the accuracy for the following four cases; in cases of regular or irregular field size, inhomogeneous material included, any errors made and clinical situation. The errors were within 2.3% for regular field size, 3.0% irregular field size, 2.4% when inhomogeneous material was included in the phantom, 3.8% for 6 MV when the error was made purposely, 4.7% for 10 MV and 1.8% for the measurement of a patient in clinic. It is considered that this methode can make the quality control for dose at the time of radiation therapy because it is non-invasive that makes possible to measure the doses whenever a patient is given a therapy as well as eliminates the problem for entrance or exit dose measurement.

  • PDF

양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교 (Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy)

  • 김경태;김선영;김대웅;김재원;박지연;전상민
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.43-49
    • /
    • 2019
  • 목 적: 움직이는 장기에 취약한 Pencil Beam Scanning(PBS)을 보완하기 위해 고안된 Layered Rescanning PBS 기법을 Moving Phantom에 적용하여 Single Scan PBS와 선량비교를 통해 Homogeneity를 비교해 본다. 대상 및 방법: Matrix X(IBA, Belgium)와 Moving Phantom(standard imaging, USA)을 이용하였다. 가상의 tumor $10{\times}10{\times}5cm$에 AP 방향에서 200 cGy의 선량을 조사하였다. 치료계획은 single scan PBS, rescan 4, 8, 12회 총 4가지로 하였고 각 치료계획별로 3번씩 반복 측정하였다. 측정 시 Moving Phantom의 호흡주기는 한 cycle당 4초로 설정 후 S-I 방향 움직임 2 cm으로 설정하였다. 추가로 beam on time을 측정하였다. 결 과: PTV 내에서 $D_{max}$의 평균값은 single scan, 4, 8, 12회 rescan 순서로 각각 $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ $D_{min}$의 평균값은 각각 $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$으로 $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$으로 측정되었다. 그리고 rescan 횟수가 늘어날수록 Homogeneity Index가 1에 가까워졌으며, beam on time은 평균 2분 15초, 3분 15초, 4분 30초, 5분 37초로 rescan 횟수가 증가할수록 치료시간이 증가되었다. 측정하는 과정에서 MU가 낮은 선량 layer에서는 설정한 rescan 횟수만큼 실제로 rescan하지 못하는 문제점이 발견되었다. 결 론: 장기 움직임이 있는 종양 치료 시 Layered Rescanning PBS을 적용했을 때 single scan PBS보다 균일한 선량분포를 확인할 수 있었다. 그리고 rescan 횟수가 증가할수록 균일한 선량분포를 보였다. single scan PBS와 12회 Layered rescanning 비교 시 HI 수치가 0.32 향상되었다. 추후 연구를 통하여 호흡동조 방사선치료가 불가능환자에게 적용이 가능할 것으로 사료된다.

Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Koo, Hyun-Jae;Cho, Min-Seok;Ha, Jin-Suk;Yoon, Do-Kun;Suh, Tae Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2017
  • The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate the characteristics. A phantom was designed to simulate diaphragm motion with amplitude in the range 1~7 cm and period up to ${\geq}2s$ of regular breathing. To simulate different tumors sizes, custom molds were created using a 3D printer and filled with liquid silicone. The accuracy of the phantom diaphragm motion was assessed by comparing measured motion with predicted motion. Because the phantom diaphragm motion is not identical to the tumor motion, the correlation between the diaphragm and tumor motions was calculated by a curve fitting method to emulate user-intended tumor motion. Tumors of different sizes were located at same position, and tumor set-up positions were evaluated. The accuracy of phantom diaphragm motion was better than 1 mm. The diaphragm-tumor correlation showed that the tumor motion in the superior-inferior direction increased with increasing diaphragm motion. The tumor motion was larger in the $10cm^3$ tumor than in the $90cm^3$ tumor. The range of difference between the tumor set-up positions was 0 to 0.45 cm. This phantom showed independently adjusting factors such as tumor size and motion to facilitate quantitative analysis of the dosimetric impact of respiratory motion according to these factors.

Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가 (The Evaluation of Resolution Recovery Based Reconstruction Method, Astonish)

  • 승종민;이형진;김진의;김현주;김중현;이재성;이동수
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.58-64
    • /
    • 2011
  • SPECT 영상에서의 resolution recovery를 기반으로 하는 3D 재구성 기법은 detector면으로부터 거리에 의한 공간적 blur를 보상하여 높은 spatial resolution과 contrast를 가지는 특징이 있다. 본 논문에서는 이러한 재구성 기법 중의 하나인 Philips사의 Astonish 프로그램을 phantom 실험을 통하여 기존의 재구성 기법과 비교, 평가하고 임상적 유용성을 높이고자 하였다. Skylight SPECT system (Philips)에서 NEMA IEC PET body phantom과 Flanges Jaszczak phantom (Data Spectrum corp.)을 이용하여 시간과 거리에 따른 4가지의 다른 입력 조건에서 실험을 실시하였다. 가까운 거리와 먼 거리 (짧은 거리보다 10 cm 더해진 거리)에서 각각 full time (40 kcts/frame)과 half time (full time의 절반)을 적용하여 영상을 얻고, iteration 수에 변화를 주어 MLEM, 3D-OSEM, Astonish로 영상을 재구성하였다. NEMA IEC PET body phantom의 각 sphere에서 background variability에 따른 contrast ratio의 변화양상을 확인하고 각 재구성 기법에서의 최적의 iteration 수를 찾아보았다. 이로부터 얻은 최적의 iteration 수를 Jaszczak phantom 영상의 재구성에 적용하여 비교해보고 실제 환자의 myocardial SPECT data에 대하여 육안적 평가를 실시하였다. 전반적인 contrast ratio는 Astonish가 MLEM과 3D-OSEM보다 높았다. 직경 37 mm의 가장 큰 hot sphere에서 짧은 거리에서는 Astonish가 MLEM과 3D-OSEM보다 각각 27.1%와 17.4%의 더 높은 contrast ratio를 보였고, 먼 거리에서는 40.5%와 32.6%로 더 높았다. 그러나 시간에 따른 변화의 차이는 크게 나타나지 않았다. 또한, 육안적 평가에서 Astonish가 다른 두 재구성 기법에 비하여 더 좋은 영상을 보였다. 이 실험에서는 정량적 분석 및 육안적 평가를 통하여 Astonish가 기존의 영상 재구성 기법인 MLEM과 3D-OSEM에 비하여 시간을 단축시켜 업무의 효율성을 높일 뿐만 아니라 질적으로도 우수한 영상을 구현하여 임상적으로 신뢰성이 높은 검사 결과를 제공할 수 있음을 확인하였다.

  • PDF

Dosimetric Effects of Low Dose 4D CT Using a Commercial Iterative Reconstruction on Dose Calculation in Radiation Treatment Planning: A Phantom Study

  • Kim, Hee Jung;Park, Sung Yong;Park, Young Hee;Chang, Ah Ram
    • 한국의학물리학회지:의학물리
    • /
    • 제28권1호
    • /
    • pp.27-32
    • /
    • 2017
  • We investigated the effect of a commercial iterative reconstruction technique (iDose, Philips) on the image quality and the dose calculation for the treatment plan. Using the electron density phantom, the 3D CT images with five different protocols (50, 100, 200, 350 and 400 mAs) were obtained. Additionally, the acquired data was reconstructed using the iDose with level 5. A lung phantom was used to acquire the 4D CT with the default protocol as a reference and the low dose (one third of the default protocol) 4D CT using the iDose for the spine and lung plans. When applying the iDose at the same mAs, the mean HU value was changed up to 85 HU. Although the 1 SD was increased with reducing the CT dose, it was decreased up to 4 HU due to the use of iDose. When using the low dose 4D CT with iDose, the dose change relative to the reference was less than 0.5% for the target and OARs in the spine plan. It was also less than 1.1% in the lung plan. Therefore, our results suggests that this dose reduction technique is applicable to the 4D CT image acquisition for the radiation treatment planning.