• Title/Summary/Keyword: 40Hz

Search Result 951, Processing Time 0.031 seconds

Pulsatile Pressure Distribution on the Snubber of Reciprocating Compressor (왕복동식 압축기의 스너버내 맥동압 분포)

  • Lee, Gyeong-Hwan;Rahman, Mohammad-Shiddiqur;Chung, Han-Shik;Jung, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.606-611
    • /
    • 2007
  • Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with piping to cause vibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and piping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materially affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. This study discusses pressure pulsation phenomena occurred in a reciprocating compressor system. An experiment applied air compressor unit, as pulsating pressure generator, has been done. The compressor was connected sequentially to a snubber model and pressure tank. Sensor probes were placed on the inlet and outlet pipes of snubber. Compressor was driven by a motor controlled by a frequency regulator. The experiment was conducted by adjusting the regulator at 40Hz. General information about an internal gas flow can be achieved by numerical analysis approach. Information of the velocity, pressure and turbulence kinetic energy distribution are presented in this paper. Based on this result, the design improvement might be done.

  • PDF

Physiological and Psychological Effects of Vibroacoustic Stimulation to Scapular and Sacrum of Supine Position

  • Lim, Seung Yeop;Heo, Hyun;Kim, Sang Ho;Won, Byeong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.345-353
    • /
    • 2013
  • Objective: This research measured physiological and psychological effects of Vibroacoustic stimulation(VA) to scapular and sacrum of supine position on the mattress. Background: When vibroacoustic stimulation applies to human body, it has a positive influence on physiological and psychological effects by stimulating the organs, tissues and cells of whole body. Method: This experiment was conducted to 10 normal males in two conditions: no stimulation and vibroacoustic stimulation. No stimulation experiment was executed as a supine position for 30 minutes without any vibrational stimulus, while vibroacoustic stimulation was transmitted by the vibrational speaker, which uses 40Hz frequency. Subjects had a laser Doppler flowmeter probe in scapular, sacrum, and also had 8 channel electroencephalogram(EEG) measurement sensor in the scalp. Blood pressure and skin temperature were measured in two conditions with an underlying posture for 30 minutes. Additionally, blood flow rate and EEG were measured before and after for two minutes on two conditions. Results: According to the vibroacoustic stimulation, blood flow rate and skin temperature were increased, while blood pressure was decreased. When using vibroacoustic stimulation compared to no stimulation, blood flow rate went approximately two times higher, and skin temperature also higher 3~4 times. Furthermore, the relative alpha power of brain wave was significantly increased when we applied to vibroacoustic stimulation. Conclusion: This experiment tested the VAT embedded in mattress in two conditions. According to this experiment, VAT decreases blood pressure, improves not only a physiological effect on blood flow rate as well as skin temperature, but also psychological functions by increasing relative alpha power. Application: The results of the publishing trend analysis might help physiological and psychological effects of vibroacoustic stimulation.

Optimization of SWCNT-Coated Fabric Sensors for Human Joint Motion Sensing

  • Cho, Hyun-Seung;Park, Seon-Hyung;Yang, Jin-Hee;Park, Su-Youn;Han, Bo-Ram;Kim, Jin-Sun;Lee, Hae-Dong;Lee, Kang-Hwi;Lee, Jeong-Whan;Kang, Bok-Ku;Chon, Chang-Soo;Kim, Han-Sung;Lee, Joo-Hyeon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2059-2066
    • /
    • 2018
  • This study explored the feasibility of utilizing an SWCNT-coated fabric sensor for the development of a wearable motion sensing device. The extent of variation in electric resistance of the sensor material was evaluated by varying the fiber composition of the SWCNT-coated base fabrics, attachment methods, number of layers, and sensor width and length. 32 sensors were fabricated by employing different combinations of these variables. Using a custom-built experimental jig, the amount of voltage change in a fabric sensor as a function of the length was measured as the fabric sensors underwent loading-unloading test with induced strains of 30 %, 40 %, and 50 % at a frequency of 0.5 Hz. First-step analysis revealed the following: characteristics of the strain-voltage curves of the fabric sensors confirmed that 14 out of 32 sensors were evaluated as more suitable for measuring human joint movement, as they yield stable resistance values under tension-release conditions; furthermore, significantly stable resistance values were observed at each level of strain. Secondly, we analyzed the averaged maximum, minimum, and standard deviations at various strain levels. From this analysis, it was determined that the two-layer sensor structure and welding attachment method contributed to the improvement of sensing accuracy.

Energy Harvesting Characteristics of Spring Supported Piezoelectric Cantilever Structure (SPCS) (압전 캔틸레버 스프링 구조물(SPCS)의 에너지 하베스팅 특성)

  • Kim, Kyoung-Bum;Kim, Chang-Il;Jeong, Young-Hun;Lee, Young-Jin;Cho, Jeong-Ho;Paik, Jong-Hoo;Nahm, Sahn;Seong, Tae-Hyeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.766-772
    • /
    • 2012
  • Spring supported piezoelectric cantilever structures (SPCS) were fabricated for vibration-based energy harvester application. We selected four elastic springs (A, B, C, and D type) as cantilever's supporter, each elastic spring has a different spring constant (S). The C type of SPCS ($S_C$: 4,649 N/m) showed a extremely low resonance frequency of 81 Hz along with the highest power output of 38.5 mW while the A type of SPCS ($S_A$: 40,629 N/m) didn't show a resonance frequency while. Therefore, it is considered that the lower spring constant lead to a lower resonance frequency of the SPCS. In addition, a tip mass (18 g) at one end of the SPCS could further reduce the resonance frequency without heavy degradation of power output.

Effect of Reserpine on Pancreatic Exocrine Secretion Induced by Mesencephalic Reticular Stimulation in Rats (흰쥐에서 Reserpine이 중뇌망상체의 자극으로 유발된 췌장의 외분비 기능에 미치는 영향)

  • Park, Hyoung-Jin;Lee, Yun-Lyul
    • The Korean Journal of Physiology
    • /
    • v.22 no.1
    • /
    • pp.101-109
    • /
    • 1988
  • 최근에 마취한 흰쥐에서 중뇌망상체를 전기적으로 자극하면 췌장의 외분비 기능이 증가하며 이러한 결과는 망상체의 자극으로 인하여 교감신경계의 활성도가 상승하기 때문이라는 보고가 있다. 한편 교감신경계의 활성도가 상승할 경우 교감신경계의 전달 물질인 catecholamine이 교감신경 종말 뿐만 아니라 부신수질에서도 유리된다고 알려져 있다. 그러므로 본 연구에서는 중뇌망상체의 자극으로 인하여 췌장의 외분비 기능이 증가함에 있어 교감신경계가 중요한 역할을 담당하는지를 확인하고, 이때 부신수질이 관여하는가를 알아보고자 하였다. 마취한 흰쥐에게 atropine (1mg/kg) 또는 reserpine (5mg/kg)을 투여하거나 또는 부신을 적출한 다음 중뇌망상체를 전기 자극하면서 췌장액을 채취하였다. 사용한 전기자극의 매개변수는 1.3V, 40Hz, 2msec이었다. atropine과 reserpine을 투여하면 마취한 흰쥐의 자발적 췌장액 분비량과 단백질 분비량은 모두 유의하게 감소하였으나 부신을 제거하면 췌장액 분비량에는 이렇다할 변동이 없는 반면에 단백질 분비량은 유의하게 감소하였다. 중뇌망상체를 전기자극하면 췌장액 분비량과 단백질 분비량 모두가 유의하게 증가하였다. 이러한 망상체의 자극효과는 atropine 전처치에 의하여 이렇다할 영향을 받지 않았으나 reserpine 전처치에 의하여 소실되었다. 그러나 부신을 적출하면 망상체 자극에 의한 췌장액 분비량의 증가는 유지되는 반면에 단백질 분비량의 증가는 소실되었다. 한편 미주신경을 절단한 흰쥐에서 중뇌망상체를 자극하는 동안에 경동맥의 수축기 및 이완기 혈압이 상승하였는데 이러한 망상체의 자극효과도 reserpine의 투여에 의하여 유의하게 감소되었다. 본 실험의 결과를 종합하여 보면 마취한 흰쥐에서 중뇌망상체의 자극은 교감신경계를 활성화시켜 췌장액 분비량과 단백질 분비량에 촉진적인 영향을 미치며, 이때 활성화된 교감신경계는 부분적으로 부신을 경유하게 췌장의 단백질 분비에 촉진적인 영향을 미치는 것으로 생각된다.

  • PDF

Exocrine Pancreatic Secretion in Response to Electrical Stimulation of Dorsal Raphe Nucleus in Rats (흰쥐에서 배측 봉선핵의 전기자극이 췌장의 외분비기능에 미치는 영향)

  • Suh, Sang-Won;Park, Hyoung-Jin
    • The Korean Journal of Physiology
    • /
    • v.24 no.2
    • /
    • pp.403-411
    • /
    • 1990
  • The present investigation was performed to see a possible influence of the dorsal raphe nucleus (DRN) on pancreatic exocrine secretion in anesthetized rats since the DRN had been known to exert a regulatory mechanism on sympathetic activity which was known to be very important for pancreatic exocrine secretion, particularly in rats. Twenty-nine Sprague-Dawley rats fasted for 24 hours were anesthetized by i.p. injection of 1 g/kg of urethane. The pancreatic duct was cannulated to collect pancreatic juice while bile juice was diverted into the jejunum. The duodenopyloric junction was tightly ligated. After surgery for collection of pancreatic exocrine secretion and recording of carotid blood pressure, a coaxial electrode was stereotaxically inserted in the DRN with a guide of a brain atlas. And then, electrical stimulus of biphasic square wave with 2 v, 2 msec, 40 Hz was applied on the electrode for 10 minutes. Pancreatic volume flow and protein output secreted in 10 min were measured. Either bilateral cervical vagotomy or spinal cord transection at the level of $C4{\sim}C5$ was performed 20 min prior to stimulation of the DRN. 1) Electrical stimulation of the DRN resulted in significant (p<0.05) increase in pancreatic volume flow and protein output. These stimulatory effects were not affected by cervical vagotomy but completely abolished by cervical cord transection. 2) Electrical stimulation of the DRN also resulted in significant (p<0.05) rise of blood pressure of the carotid artery. The hypertensive effect was not affected by cervical vagotomy but completely abolished by cervical cord transection. The results strongly suggest that the DRN, a part of the central serotonergic system, could exert a stimulatory influence on pancreatic exocrine secretion by increasing the sympathetic activity in anesthetized rats.

  • PDF

Intracisternal Antidepressants Suppressed the Nociceptive Jaw Opening Reflex in Freely Moving Rats

  • Ahn, Dong-Kuk;Kim, Yun-Sook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.3
    • /
    • pp.307-312
    • /
    • 1998
  • This study was performed to investigate the mechanism of central analgesic effects of antidepressants. Thirty four male rats were anesthetized with pentobarbital sodium (40 mg/kg, ip). A stainless steel guide cannula and a PE tube (PE10) were implanted into the lateral ventricle and cisterna magna area. Stimulating and recording electrodes were implanted into the incisor pulp and anterior digastric muscle. Electrodes were led subcutaneously to the miniature cranial connector sealed on the top of the skull with acrylic resin. The jaw opening reflex was used in freely moving rats, and antidepressants were administered intracisternally in order to eliminate the effects of anesthetic agents on the pain assessment and evaluate the importance of the central action site of antidepressants. After 48 hours of recovery from surgery, digastric electromyogram (dEMG) of freely moving rats was recorded. Electrical shocks (200 ${\mu}sec$ duration, 0.5-2 mA intensity) were delivered at 0.5 Hz to the dental pulp every 2 minute. Intracisternal administration of $15\;{\mu}g$ imipramine suppressed dEMG elicited by noxious electrical stimulation in the tooth pulp to $76{\pm}6%$ control. Intracisternal administration of $30\;{\mu}g$ desipramine, nortriptyline, or imipramine suppressed dEMG remarkably to $48{\pm}2,\;27{\pm}8,\;or\;25{\pm}5%$ of the control, respectively. Naloxone, methysergide, and phentolamine blocked the suppression of dEMG produced by intracisternal antidepressants from $23{\pm}2\;to\;69{\pm}4%,\;from\;32{\pm}5\;to\;80{\pm}9%,\;and\;from\;24{\pm}6\;to\;77{\pm}5%$ of the control, respectively. These results indicate that antidepressants produce antinociception through central mechanisms in the orofacial area. Antinociception of intracisternal antidepressants seems to be mediated by an augmentation of descending pain inhibitory influences on nociceptive pathways.

  • PDF

A Research Trend on Film Thickness Dependence of Ac High Feld for Low Density Polyethylene (저밀도 폴리에틸렌을 위한 고전계 파형의 필름 두께의존성에 관한 연구 동향)

  • Jung, Sung-Chan;Rho, Jung-Hyun;Lee, Joo-Hong;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1988-1989
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

Comparison to Dielectric and Electrical Characteristics of Fatty Acid Organic Thin Film for Length of Alkyl Group (알킬기의 길이에 따른 지방산계 유기초박막의 유전 및 전기적 특성 비교)

  • 강기호;이준호;김도균;권영수;장정수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.343-346
    • /
    • 1999
  • We have investigated the dielectric and electrical characteristics of palrnitic acid(PA), stearic acid(SA) and arachidic acid(AA) Langmuir-Blodgett(LB) films because these fatty acid systems have a same hydrophilic group and a different hydrophobic one(alky1 chain lqngth). The dielectric characteristics such as the capacitance-frequency(C-F) characteristics and the dielectric dispersion and absorption characteristics of PA, SA and AA through-plane were measured. In the result, the relative dielectric constants of PA, SA and AA LB films were about 3.0-4.6, 2.7-4.1 and 2.4-3.8, respectively. The relative dielectric constants were decreased in proportion to the chain length of alkyl group. Also, the dielectric dispersion and absorption of each fatty acid LB films have arisen from the dipole polarization in the range of $10^4~10^5[Hz]. And, the conductivity of PA, SA and AA LB films obtained from I-V characteristics were about $9{\times}10^{-14}, 3{\times}10^{-l4} and 5{\times}10^{-15}[S/cm], respectively. These results have shown the insulating materials and could control the conductivity by changing the length of alkyl group. Also, we have confirmed that the barrier height of fatty acid systems were about 1.32-1.40[eV] and the dielectric constant were about 3.0-4.2. These values were almost the same ones obtained from dielectric characteristics.

  • PDF

Characteristics Analysis and Fabrication of an Ultrasonic Motor for Auto Focusing and Optical zooming (Auto Focusing 및 Optical zooming에 사용될 초음파모터의 특성분석)

  • Yun, Yong-Jin;Kwon, Oh-Duk;Lee, Jong-Sub;Kang, Sung-Hwa;Lim, Ki-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.330-331
    • /
    • 2005
  • 본 논문에서는 카메라폰용 광학중(Optical zooming) 과 자동초점조절장치 (Auto Focusing, AF)에 쓰일 초음파모터를 제작하였다. 초음파모터의제작 및 시뮬레이션은 유한요소해석 프로그램인 ATILA 5.2.1 (Magsoft co.)를 사용하여 디자인설계에 따른 구동특성을 고찰하였고 제작된 초음파모터는 한쪽 면이 없는 사작형의 탄성체를 제작하였으며 탄성체의 양쪽 다리에 각각 압전체를 부착하였다. 또한 압전세라믹의 조성은 $0.9Pb(Zr_{0.51}Ti_{0.49})O_3-0.1Pb(Mn_{1/3}Nb_{1/3}Sb_{1/3})O_3$의 조성으로 설계하였고 시편의 제조는 7-layer로 적층하였다. 제작된 압전세라믹의 치수는 6*2*0.35$mm^3$(길이*폭*두께)로 제작하였다 또한 탄성체의 외형치수는 10*10*2$mm^3$로 제작하였으며 두께를 각각 0.3[mm], 0.5[mm], 0.8[mm]으로 변화시키며 제작하였다. 두께가 0.8[mm]인경우 공진주파수는 60.5[kHz]를 나타내었으며 초음파모터의 압전세라믹에 인가전압이 증가함에 따라 회전속도와 모터에 흐르는 전류는 증가하였다. 인가전압이 40[Vpp] 일 때 회전속도는 206[rpm] 이며 소비전력은 0.3[W]로 제작된 시편은 카메라폰용 광학중 및 자동초점조절장치시스템 분야에 응용이 가능하다.

  • PDF