• Title/Summary/Keyword: 4-wire

Search Result 1,729, Processing Time 0.033 seconds

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF

A Study of Image Quality Improvement Through Changes in Posture and Kernel Value in Neck CT Scanning (경부 CT검사 시 Kernel 값과 검사자세 변화를 통한 화질개선에 관한 연구)

  • Kim, Hyeon-Ju;Chung, Woo-Jun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.59-66
    • /
    • 2011
  • There is a difficulty because of classifying the anatomical structure in the neck CT scan by the beam hardening artifact no more than disease and it including the 6, 7 number cervical spine and intervertebral disk. In case of enforcing the neck CT scan cause of the inner diameter of beam artifact tried to be inquired by the image evaluation according to the change of the image evaluation according to the direction of the shoulder joint applying the variation method of a posture and location and Kernel value and it was most appropriate, the lion tax and Kernel value try to be searched for through an experiment. Somatom Sensation 16 (Siemens, Enlarge, Germany) equipment was used in a patient 30 people coming to the hospital for the neck CT scan. A workstation used the AW 4.4 version (GE, USA). According to a direction and location of the shoulder joint, the patient posture gave a change to the direction of the shoulder joint as the group S it gave a change as three postures and placed the both arms comfortably and helps a group N and augmented unipolar left in the wealthy merchant and group P it memorized the both hands and ordered the eversion and drops below to the utmost and enforced a scan. By using a reconstructing method as the second opinion, it gave and reconstructed the Kernel value a change based on scan data with B 10 (very smooth), B 20 (smooth), B 30 (medium smooth), B 40 (medium), B 50 (medium sharp), B 60 (sharp), and B 70 (very sharp). By using image data which gave the change of the examination posture and change of the Kernel value and are obtained, we analyzed through the noise value measurement and image evaluation of. The outside wire eversion orders the both hands and the examination posture is cost in the neck CT scan with the group P it drops below to the utmost. And in case of when reconstructing with B 40 (medium) or B 50 (medium sharp) being most analyzed into the inappropriate posture and Kernel value and applying the Kernel value to a clinical, it is considered to be very useful.

Three point bending test of recycled Nickel-Titanium alloy wires (재생한 니켈 티타늄 호선의 3점 굴곡물성실험)

  • Lee, Sung-Ho;Chang, Young Il
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.731-738
    • /
    • 2000
  • The purpose of this study was to investigate the change of 3 point bending properties of various nickel titanium wires after recycling. Four Types of nickel-titanium (Align: martensitic type, NiTi, Optimalloy, Sentalloy: austenitic type) wires were divided to three groups: as-received condition (T0: control group), treated in artificial saliva for four weeks (T1) and autoclaved after being treated in artificial saliva (T2). Detrimental changes were observed for the selected mechanical properties in three point bending test. Loading force at 3mm deflection, unloading force at 3mm deflection, stress hysteresis, loading force at 1mm deflection, unloading force at 1mm deflection and stress hysteresis at 1mm deflection were calculated. The findings suggest that : 1. Align demonstrated statistically significant increase In loading force (p<0.05) and unloading force (p<0.01) at 3mm deflection after recycling(T2), but NiTi, Optimalloy and Sentalloy showed no statistically difference after recycling. 2. Align demonstrated statistically significant decrease in hysteresis(p<0.01) after recycling(T2) but NiTi, Optimalloy and Sentalloy showed no statistically significant difference after recycling. 3. All wires showed no statistically significant difference in loading force at 1mm deflection after recycling(T2). 4. Align demonstrated statistically significant decrease in unloading force in 1mm deflection (p<0.05) after recycling(T2) but NiTi, Optimalloy and Sentalloy showed no statistically difference after recycling 5. Loading force and unloading force of T1 showed no significant change compared with those of T0, but loading force and unloading force of T2 showed significant changes compared with those of T0(p<0.05, p<0.01 respectively). 6. Align demonstrated a tendency to lose some of this pseudoelasticity in T1 and pseudoplasticity and pseudoelasticity in T2.

  • PDF

Operative Treatment of Distal Clavicle Fracture with Acromioclavicular Joint Injury (견봉 쇄골 관절의 손상을 동반한 원위 쇄골 골절의 수술적 치료)

  • Kang, Ho-Jung;Koh, Il-Hyun;Joo, Jong-Hwan;Chun, Yong-Min;Kim, Hyung-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: We wanted to evaluate the clinical and radiological outcomes and the prognosis of various surgical treatments for the distal clavicle fracture with an acromioclavicular joint injury. Materials and Methods: A retrospective study of 21 patients with a minimum of 12 months follow up was done. We classified acromioclavicular (AC) injury into type I (only intra-articular fracture (IAF), 5 cases), type II (IAF with widening of the AC joint > 7 mm, 9 cases) and type III (IAF with AC joint superior subluxation > 50%, 7 cases). The distal clavicle fractures were fixed using plate (9 cases), mini screws (1 case), K wire and tension band wiring (10 cases) and transarticular pinning (1 case). Acromioclavicular or coracoacromial ligament reconstruction was not done in all the cases. Results: In 20 of 21 cases, bone union was achieved at an average of 8.4 weeks. Traumatic arthritis (5 cases), AC joint widening (4 cases) and AC joint subluxation (2 cases) were noted at the last follow up. The average UCLA score was 32.6 in the type I AC joint injuries, 34 in type II and 34.1 in type III. There was no relationship between the clinical outcomes and the preoperative AC joint injury pattern, postoperative traumatic arthritis, AC joint widening or AC joint subluxation (p>0.05). Conclusion: Satisfactory results were achieved by acute reduction and firm fixation of the distal clavicle fracture with AC joint injury. There was no relationship between the pattern of AC joint injury, the residual radiologic findings and the functional outcome.

Clinicopathological Correlation of Intralobar Pulmonary Sequestration (내엽성 폐격리증의 임상적 특성과 조직병리학적 소견의 연관성)

  • Cho, Hyun-Min;Shin, Dong-Hwan;Kim, Kil-Dong;Lee, Sak;Chung, Kyung-Young
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.356-362
    • /
    • 2003
  • Background: Intralobar and extralobar pulmonary sequestrations have been considered as congenital lesions that occur at different stages of embryonic life. However, most cases of intralobar pulmonary sequestration (IPS) seem to have an acquired origin, as they are absent in infants and associated anomalies are relatively, uncommon among them. Material and Method: The cases of 25 patients who were diagnosed as IPS after surgical resection from December, 1985 to July, 2002 were included in this study. The medical records wire retrospectively reviewed and the clinical characteristics were age at operation; gender; symptoms at presentation; presence of congenital anomalies; combined diseases; preoperative studies and diagnosis; location of the lesion; method of surgical resection; origin, size and numbers of aberrant artery; histopathological findings; and postoperative complications. Result: There were 17 (68%) female patients and 8 (32%) male patients, their ages ranged from 1 to 57 and mean value was 23 years old. Though 14 patients (56%) complained of respiratory symptoms such as pneumonia and recurrent respiratory infections, a large number of patients (44%) were asymptomatic or had chest pain only when the lesion was discovered. Only 8 patients (32%) were diagnosed as pulmonary sequestration preoperatively and 8 (32%) were suspected as mediastinal or lung tumor, 5 (20%) were congenital or acquired cystic lung disease, and 4 (16%) were lung abscess or bronchiectasis, respectively. The majority of aberrant arteries (86.4%) confirmed during the operation were originated from thoracic aorta and 2 were thoracic and abdominal aorta, 1 was abdominal aorta, respectively. The younger patients (less than 10 years old) had more other congenital anomalies (30% vs 6.7%) but the proportion of congenital IPS was not significantly different (10% vs 6.7%, p>0.05) compared with elder patients. Histopathologically, almost all lesions showed chronic inflammation, cystic changes and similar pleural adhesions regardless of age. Conclusion: The large portion of the patients with IPS (44%) was clinically asymptomatic or presented non-respiratory symptoms at diagnosis and likely to be diagnosed as mediastinal or lung tumor especially in elder patients. Though the younger patients had more other congenital anomalies, most cases of IPS proved to be acquired lesions in terms of the histopathlogical findings and the proportion of congenital evidences.

Development of B4C Thin Films for Neutron Detection (스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Cho, Sang-Jin;Choi, Young-Hyun;Park, Jong-Won;Moon, Myung Kook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • $^3He$ gas has been used for neutron monitors as the neutron converter owing to its advantages such as high sensitivity, good ${\gamma}$-discrimination capability, and long-term stability. However, $^3He$ is becoming more difficult to obtain in last few years due to a global shortage of $^3He$ gas. Accordingly, the cost of a neutron monitor using $^3He$ gas as a neutron converter is becoming more expensive. Demand on a neutron monitor using an alternative neutron conversion material is widely increased. $^{10}B$ has many advantages among various $^3He$ alternative materials, as a neutron converter. In order to develop a neutron converter using $^{10}B$ (actually $B_4C$), we calculated the optimal thickness of a neutron converter with a Monte Carlo simulation using MCNP6. In addition, a neutron converter was fabricated by the Ar sputtering method and the neutron signal detection efficiencies were measured with respect to various thicknesses of fabricated a neutron converter. Also, we developed a 2-dimensional multi-wire proportional chamber (MWPC) for neutron beam profile monitoring using the fabricated a neutron converter, and performed experiments for neutron response of the neutron monitor at the 30 MW research reactor HANARO at the Korea Atomic Energy Research Institute. The 2-dimensional MWPC with boron ($B_4C$) neutron converter was proved to be useful for neutron beam monitoring, and can be applied to other types of neutron imaging.

A Study on History and Archetype Technology of Goli-su in Korea (한국 고리수의 역사와 원형기술의 복원 연구)

  • Kim, Young-ran
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.2
    • /
    • pp.4-25
    • /
    • 2013
  • Goli-su is the innovative special kind of the embroidery technique, which combines twining and interlacing skill with metal technology and makes the loops woven to each other with a strand. The loops floating on the space of the ground look like floating veins of sculpture and give people the feeling of the openwork. This kind of characteristic has some similarities with the lacework craft of Western Europe in texture and technique style, but it has its own features different from that of Western Europe. It mainly represents the splendid gloss with metallic materials in the Embroidered cloth, such as gold foil or wire. In the 10th century, early days of Goryo, we can see the basic Goli-su structure form of its initial period in the boy motif embroidery purse unearthed from the first level of Octagonal Nine-storied Pagoda of Woljeong-sa. In the Middle period of Joseon, there are several pieces of Goli-su embroidered relic called "Battle Flag of Goryo", which was taken by the Japanese in 1592 and is now in the Japanese temple. This piece is now converted into altar-table covers. In 18~19th century, two pairs of embroidered pillows in Joseon palace were kept intact, whose time and source are very accurate. The frame of the pillows was embroidered with Goli-su veins, and some gold foil papers were inserted into the inside. The triangle motif with silk was embroidered on the pillow. The stitch in the Needle-Looped embroidery is divided into three kinds according to comprehensive classification: 1. Goli-su ; 2. Goli-Kamgi-su ; 3. Goli-Saegim-su. From the 10th century newly establishing stage to the 13th century, Goli-su has appeared variational stitches and employed 2~3 dimensional color schemes gradually. According to the research of this thesis, we can still see this stitch in the embroidery pillow, which proves that Goli-suwas still kept in Korea in the 19th century. And in terms of the research achievement of this thesis, Archetype technology of Goli-su was restored. Han Sang-soo, Important Intangible Cultural Heritage No. 80 and Master of Embroidery already recreated the Korean relics of Goli-su in Joseon Dynasty. The Needle-Looped embriodery is the overall technological result of ancestral outstanding Metal craft, Twining and Interlacing craft, and Embroidery art. We should inherit, create, and seek the new direction in modern multi-dimensional and international industry societyon the basis of these research results. We can inherit the long history of embroidering, weaving, fiber processing, and expand the applications of other craft industries, and develop new advanced additional values of new dress material, fashion technology, ornament craft and artistic design. Thus, other crafts assist each other and broaden the expressive field to pursue more diversified formative beauty and beautify our life abundantly together.

Identification of bacteria from the peri-implant sulcus of orthodontic mini-implants using 16S rDNA clone library (16S rDNA 클론 library 제작 및 핵산염기서열 결정을 통한 교정용 미니임플랜트 주위 열구의 세균 동정)

  • Lim, Sung-Hoon;Kim, Kwang-Won;Yoo, So-Young;Kook, Joong-Ki;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.251-262
    • /
    • 2006
  • Objective: The purpose of this study was to compare the bacterial flora at the peri-implant sulcus of the orthodontic mini-implant placed in the alveolar mucosa with the bacterial flora at the adjacent healthy gingival sulcus. Methods: Two plaque samples from 7 patients were collected by inserting paper points into the sulcus between the mini-implant and ligature wire connected to the mini-implant head and inflamed alveolar mucosa, and from the gingival sulcus of a healthy tooth adjacent to the mini-implant. Results: Using 16S rDNA clone library, the 24 kinds of bacteria including Haemophilus aphrophilus, Sphingomonas species, Capnocytophaga species, Prevotella melaninogenica, Lachnospiraceae species, Porphyromonas species, Neisseria flava were identified only from the sulcus around the mini-implant. These bacteria constituted only 9.2% of total clones, and the bacteria identified from both the sulcus around mini-implants and the gingival sulcus constituted 80.4% of total clones. Of these bacteria, clones of Prevotella species, Atopobium rimae, Veillonella species, Streptococcus intermedius/constellatus, Streptococcus salivarius were more frequently isolated from the peri-implant sulcus. Conclusion: This study suggests that a broad epidemiological study is needed to find causative bacteria which induce inflammation from the peri-implant sulcus.

A Study on the labial & buccal surface contour in Korean permanent teeth using three-dimensional laser scanning (3차원 레이저 스캐너를 이용한 한국인 영구치의 순, 협측 치관 굴곡도에 관한 연구)

  • Ko, Sang-Duck;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.275-291
    • /
    • 2002
  • Of various factors indicated for effective use of straight wire appliances, there was a great lack of studies both domestic and international about the curvatures of tooth crowns. This study was performed to investigate the labio/buccal clinical crown curvatures of Korean permanent teeth. For this study, three-dimensional laser scanning was performed on 36 dental casts with normal anatomic structures. Andrews plane and Facial axis of clinical crown (FACC) were designated as horizontal and vertical reference planes respectively. 2 or 3 lines, 1mm apart, were drawn superior, inferior, left and right of these reference planes. A three-dimensional coordinate table was made for points formed by crossing these lines, and averages of each coordinate point on the 36 dental casts were obtained. The curvature equation was made using three-dimensional coordinate points (x,y,z) and by this curvature equation, the curve ratio of each tooth was obtained. Curve ratio changes of each section of teeth were calculated by curve ratios of simplified curves. These two dimensional curves were simplified horizontally and vertically Conclusions for this study are as follows. 1. The basic data of labial and buccal clinical crown curvatures were obtained about Korean permanent teeth. 2. No significant difference was found between male and females. 3. Individual tooth characteristics 1) In maxillary central incisors, the difference in the curve ratio between the gingival and incisal sides was greater than for the other teeth. And the gingival side showed a greater curve ratio. 2) Maxillary canines showed more curvatures in the mesio-occlusal surface than the other surfaces. 3) In maxillary $1^{st}$ premolars, more curvatures were found in mesio-occlusal and disto-gingival surface, thus showing a twisted crown surface, but in maxillary $2^{nd}$ premolars, the crown curvatures of mesial and distal ends became parallel to each other. 4) No significant difference in crown curvatures was found between mandibular central and lateral incisors. 5) Occluso-gingival curvatures of mandibular$2^{nd}$ premolar turned out to be more rounded than mandibular $1^{st}$ premolars or maxillary $2^{nd}$ premolars. From the above conclusions, it can be deduced that the same bracket bases can be used for mandibular central and lateral incisors. But for maxillary $1^{st}\;and\;2^{nd}$ premolars and for mandibular $1^{st}\;and\;2^{nd}$ premolars, because crown curvatures showed significant differences, when making bracket bases there is ample reason to make bracket base curves differently for each type of tooth.

Treatment of Osteoid Osteoma (유골 골종의 치료)

  • Han, Chung-Soo;Cho, Chang-Hyun;Cho, Young-Lin;Cho, Nam-Su;Lim, Chan-Teak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose : The purpose of the current study was to report the results of curettage and en bloc excision as well as to introduce how to excise the nidus percutaneously with Halo-mill. Material and Methods : Twenty patients(14 men and 6 women) were evaluated, who had operative treatments after diagnosed as osteoid osteoma from March 1990 to January 1998. These patients ranged in age from 7 to 42 years(average: 20.8 years). Locations were 9 femurs, 6 tibias, 2 vertebras, 1 ulna, 1 maxilla and 1 skull. Nine femoral lesions included 5 proximal metaphysis, 2 neck and 2 diaphysis, while 5 tibial lesions included 3 diaphysis, 1 proximal metaphysis and 1 distal metaphysis. We used simple radiography, bone scan, CT and MRI for the accurate diagnosis and localization. As for surgical treatments, while excision and curettage had to need open-exposure of lesion, the percutaneous excision of nidus did not need openexposure : guided Halo-mill into K-wire inserted to nidus under image intensifier. Results : Simple radiography showed that 10 cases had typical nidus and others had only cortical sclerosis. Bone scan was performed at 14 cases and all had hot uptake except one case. We used CT in 10 cases and MRI in 4 cases as diagnostic methods, of which 1 case didn't reveal nidus at CT. Surgical treatment consisted of 6 curettages, 11 excisions, 2 percutaneous excisions with halo-mill and 1 total elbow arthroplasty. We used 7mm sized Halo-mill. During the follow-up period, all patient relieved symptoms and there were no recurrences. All had histologically typical findings except one which had hyperostosis without nidus. Conclusion : Complete removal of the nidus is the most important factor in the treatment. We could excise the nidus percutaneously in 2 cases with the minimal injury to surrounding soft tissues. If we could evaluate the precise location, size of nidus and percutaneous acccesibility, the percutaneous excision of nidus with Halo-mill could be an alternative method as a treatment of osteoid osteoma.

  • PDF