• 제목/요약/키워드: 4-switch

검색결과 1,044건 처리시간 0.026초

LTCC 기술을 이용한 RF Switch Module의 집적화에 관한 연구 (A study on the integration of Rf switch module using LTCC technology)

  • 김지영;김인성;민복기;송재성;서영석;남효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.710-713
    • /
    • 2004
  • The design, simulation, modeling and measurement of a low temperature co-fired ceramic (LTCC) RF switch module for GSM applications is presented in this paper. RF switch module is constructed using a Rx/Tx switching circuit and integrated low pass filter. The low pass filter function was designed to operate in th GSM band. Insertion and return loss of the low pass filter were designed less than 0.3 dB and better than 12.7 dB at 900 MHz. The RF switch module contained 10 embedded passives and 3 surface mount components integrated on $4.6{\times}4.8{\times}1.2$ nm, 6-layer multi-layer integrated circuit. The insertion loss of switch module was measured at 900 MHz was 11 dB.

  • PDF

2.4[GHz]/5.8[GHz] 이중대역 SPDT 스위치 설계 (Design of a Dual-Band Switch with 2.4[GHz]/5.8[GHz])

  • 노희정
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.52-58
    • /
    • 2008
  • 본 논문에서는 2.4[GHz]/5.8[GHz] 대역의 이중대역 스위치 설계에 대하여 논한다. 이 스위치는 TDD시스템에 적용 가능하며, 광대역 특성을 개선할 수 있는 새로운 구조를 제안하고 시뮬레이션을 통해 최적의 구조로 설계하였다. 2.4[GHz]/5.8[GHz] 이중대역 스위치는 현재 상용화되고 있는 802.11a/b/g 시스템에 응용할 수 있는 광대역, 고출력, 높은 격리도를 갖는 구조를 연구하였다. 스위치의 송신부는 2개의 FET를 스택 구조로 병렬 스위칭 소자로 동작하도록 설계하였다. 수신부는 기본적인 직/병렬 FET에 추가로 직렬 FET를 삽입한 비대칭 구조를 갖도록 수신부를 설계하였다. SPDT(Single Pole Double Throw) Tx/Rx FET 스위치는 하나의 입력에 2개의 출력으로 스위칭할 수 있는 장치이다. 이 제작된 스위치는 삽입손실 특성은 DC$\sim$6[GHz]까지 3[dB]보다 낮으며 수신경로의 격리도는 -30[dB]이하의 특성을 가지고 있다.

3상 SRM 구동용 4-스위치 인버터 PWM 제어 알고리즘 (Control Algorithm for 4-Switch Inverter of 3-Phase SRM)

  • 윤용호;이병국;원충연
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.303-309
    • /
    • 2009
  • Switched Reluctance Motor(SRM) has become popular for industrial application, particularly for low medium drives due to the advantages of SRM over the other ac motors: SRM can be manufactured with low cost because it has a simple structure. But, asymmetric bridge converter that generally is used for driving requires two discrete switching devices and freewheeling diodes per phase, and cause the SRM drives to be complicated and to increase the cost of overall system. Therefore, this paper suggests a new type of 4-switch converter for SRM. 4-switch converter topology is studied to provide a possibility for the realization of low cost 3-phase SRM drive system. For effective utilization of the developed system, a new current control algorithm is designed and implemented to produce the desired dynamic performance. With the developed power conversion circuit and control scheme, it is expected that the proposed system can be widely used in commercial applications with reduced system cost.

도시형 자기부상열차 3방향 분기기 개발현황 및 시험결과 (Development Status and Test Results of the 3 way Switch for the Urban Maglev)

  • 이종민;한형석;김창현;신현재;서성호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1742-1749
    • /
    • 2011
  • The 3 way segmented Maglev switch is developed for the urban Maglev vehicle, which is scheduled to debut at the middle of 2013 in Incheon International Airport. The 3 way switch is composed of 3 moving girders, 4 fixed girders, driving units, moving units, clamping units and articulated angle relieving equipment etc. In this paper, the measured results on the interaction between vehicle and switch are discussed. The measured results are following; First, continuous moving test and natural frequency for girder and levitation rail. Second, levitation and lateral air gap of the bogies running on the curved switch. Third, noise of moving mechanical parts of the 3 way segmented switch. Forth, thermal displacement of the girder due to temperature change. With over the measured results, more reliability and stability of the 3 way segmented switch are secured.

  • PDF

Small-Sized High-Power PIN Diode Switch with Defected Ground Structure for Wireless Broadband Internet

  • Kim, Dong-Wook
    • ETRI Journal
    • /
    • 제28권1호
    • /
    • pp.84-86
    • /
    • 2006
  • This letter presents a small-sized, high-power single-pole double-throw (SPDT) switch with defected ground structure (DGS) for wireless broadband Internet application. To reduce the circuit size by using a slow-wave characteristic, the DGS is used for the quarter-wave (${\lambda}$/4) transmission line of the switch. To secure a high degree of isolation, the switch with DGS is composed of shunt-connected PIN diodes. It shows an insertion loss of 0.8 dB, an isolation of 50 dB or more, and power capability of at least 50 W at 2.3 GHz. The switch shows very similar performance to the conventional shunt-type switch, but the circuit size is reduced by about 50% simply with the use of DGS patterns.

  • PDF

A Single-Pole, Eight-Throw, Radio-Frequency, MicroElectroMechanical Systems Switch for Multi-Band / Multi-Mode Front-End Module

  • Kang, Sung-Chan;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.77-81
    • /
    • 2011
  • This paper presents a single-pole eight-throw(SP8T) switch based on proposed a radio-frequency(RF) microelectromechanical systems (MEMS) switches. The proposed switch was driven by a double stop(DS) comb drive, with a lateral resistive contact. Additionally, the proposed switch was designed to have tapered signal line and bi-directionally actuated. A forward actuation connects between signal lines and contact part, and the output becomes on-state. A reverse actuation connects between ground lines and contact part, and the output becomes off-state. The SP8T switch of 3-stage tree topology was developed based on an arrangement of the proposed RF MEMS switches. The developed SP8T switch had an actuation voltage of 12 V, an insertion loss of 1.3 dB, a return loss of 15.1 dB, and an isolation of 31.4 dB at 6 GHz.

토템폴 브리지리스 PFC에서 동기정류 스위치의 효율 영향에 관한 연구 (A Study on Influence of Synchronous Rectification Switch on Efficiency in Totem Pole Bridgeless PFC)

  • 유정상;안태영
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.108-113
    • /
    • 2021
  • In this paper, a totem pole PFC was structured in two methods with FET and diode for low-speed switch while GaN FET was used for high-speed switch. Internal power loss, power conversion efficiency and steady-state characteristics of the two methods were compared in the totem pole bridgeless PFC circuit which is widely applied in large-capacity and high-efficiency switching rectifier of 500W or more. In order to compare and confirm the steady-state characteristics under equal conditions, a 2kW class totem pole bridgeless PFC was constructed and the experimental results were analyzed. From the experimental results, it was confirmed that the low-speed switch operation has a large difference in efficiency due to the internal conduction loss of the low-speed switch at a low input voltage. Especially, input power factor and load characteristic showed no difference regardless of the low-speed switch operation.

A New Controllable Active Clamp Algorithm for Switching Loss Reduction in a Module Integrated Converter System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.465-471
    • /
    • 2014
  • This paper proposes a new switching algorithm for an active clamp snubber to improve the efficiency of a module integrated converter system. This system uses an active clamp method for the snubber circuit for the efficiency and reliability of the system. However, the active clamp snubber circuit has the disadvantage that system efficiency is decreased by switch operating time because of heat loss in resonance between the snubber capacitor and leakage inductance. To address this, this paper proposes a new switching algorithm. The proposed algorithm is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time. Also, the snubber switch is operated at zero voltage switching by turning on the snubber switch before main switch turn-off. Simulation and experimental results are presented to show the validity of the proposed new active clamp control algorithm.

Design of T/R Switch Using LTCC Technology

  • Sim, Sung-Hun;Kang, Chong-Yun;Park, Ji-Won;Yoon, Young-Joong;Kim, hyun-Jai;Park, Hyung-Wook;Yoon, Seok-Jin
    • 한국세라믹학회지
    • /
    • 제40권4호
    • /
    • pp.375-379
    • /
    • 2003
  • In this paper, a novel design of multilayer ceramic-based Transmit/Receive (T/R) switch using Low Temperature Co-fired Ceramic (LTCC) technology have been presented. Compact T/R switch has been designed by transforming quarter-wave transmission line to its lumped equivalent circuit. Especially, high-Q three dimensional inductors with double strip have been proposed and incorporated. The proposed inductor has been modeled by multi-conductor coupled lines. A measured inductor quality factor (Q) of 80 and a Self-Resonance Frequency (SRF) of 6.6 GHz have been demonstrated. The inductor library has been incorporated into the design of WCDMA T/R switch.

Analyzing the Impact of Buffer Capacity on Crosspoint-Queued Switch Performance

  • Chen, Guo;Zhao, Youjian;Pei, Dan;Sun, Yongqian
    • Journal of Communications and Networks
    • /
    • 제18권3호
    • /
    • pp.523-530
    • /
    • 2016
  • We use both theoretical analysis and simulations to study the impact of crosspoint-queued (CQ) buffer size on CQ switch throughput and delay performance under different traffic models, input loads, and scheduling algorithms. In this paper, we present the following. 1) We prove the stability of CQ switch using any work-conserving scheduling algorithm. 2) We present an exact closed-form formula for the CQ switch throughput and a non-closed-form but convergent formula for its delay using static non-work-conserving random scheduling algorithms with any given buffer size under independent Bernoulli traffic. 3) We show that the above results can serve as a conservative guide on deciding the required buffer size in pure CQ switches using work-conserving algorithms such as the random scheduling, under independent Bernoulli traffic. 4) Furthermore, our simulation results under real-trace traffic show that simple round-robin and random work-conserving algorithms can achieve quite good throughput and delay performance with a feasible crosspoint buffer size. Our work reveals the impact of buffer size on the CQ switch performance and provides a theoretical guide on designing the buffer size in pure CQ switch, which is an important step toward building ultra-high-speed switch fabrics.