• 제목/요약/키워드: 4-BAR

검색결과 2,231건 처리시간 0.036초

Bond strength of reinforcement in splices in beams

  • Turk, Kazim;Yildirim, M. Sukru
    • Structural Engineering and Mechanics
    • /
    • 제16권4호
    • /
    • pp.469-478
    • /
    • 2003
  • The primary aim of this study was to investigate the bond strength between reinforcement and concrete. Large sized nine beams, which were produced from concrete with approximately ${f_c}^{\prime}=30$ MPa, were tested. Each beam was designed to include two bars in tension, spliced at the center of the span. The splice length was selected so that bars would fail in bond, splitting the concrete cover in the splice region, before reaching the yield point. In all experiments, the variable used was the reinforcing bar diameter. In the experiments, beam specimens were loaded in positive bending with the splice in a constant moment region. In consequence, as the bar diameter increased, bond strength and ductility reduced but, however, the stiffnesses of the beams (resistance to deflection) increased. Morever, a empirical equation was obtained to calculate the bond strength of reinforcement and this equation was compared with Orangun et al. (1977) and Esfahani and Rangan (1998). There was a good agreement between the values computed from the predictive equation and those computed from equations of Orangun et al. (1977) and Esfahani and Rangan (1998).

적층 벤더형 압전식 공압밸브의 내구 특성 (Endurance of Pneumatic Valve with a Multi-bender PZT Actuator)

  • 윤소남;박인섭
    • 동력기계공학회지
    • /
    • 제18권2호
    • /
    • pp.31-36
    • /
    • 2014
  • In this paper, pneumatic valve which consists of valve body, valve controller, nozzle and a multi-bender PZT actuator was suggested and fabricated. The fabricated pneumatic valve was experimented for performance evaluation. From the experimental results, we know that the flow rate of the suggested valve is 23 lpm at the pressure difference of 1bar and the maximum flow rate is 30 lpm at the pressure difference of 4 bar. The flow rates after endurance test of 9.8 million were 22.57 lpm and 28.62 lpm at the pressure difference of 1bar and 4bar, respectably. Finally, it was verified that the B10 life of the suggested pneumatic valve is over 50 million.

데오드라이트 시스템의 측정 정확도에 대한 연구(V) - 타켓 바의 거리에 따른 측정 정확도 (A Study on Measurement Accuracy of A Theodolite System(V) - A Measurement System Accuracy depending on the distance from theodolite system to target Bars)

  • 윤용식;이동주
    • 한국공작기계학회논문집
    • /
    • 제14권4호
    • /
    • pp.13-21
    • /
    • 2005
  • The affected factors for an accuracy of theodolite system are not only the measurement environment of temperature, illumination, etc. but also the measurement processes of the distance between two theodolites, the distance from theodolite system to scale bar and the distance from theodolite system to targets. We have known that the best collimation distance between two theodolites and the best distance from theodolite system to scale bar is $3{\sim}4m$. This study was performed for searching the best distance from theodolite system to targets on above measurement configuration. And, we could know that the best distance from theodolite system to targets is $2{\sim}6m$ and the system accuracy could be within ${\pm}0.025mm$.

Synthesis of four-bar linkage motion generation using optimization algorithms

  • Phukaokaew, Wisanu;Sleesongsom, Suwin;Panagant, Natee;Bureerat, Sujin
    • Advances in Computational Design
    • /
    • 제4권3호
    • /
    • pp.197-210
    • /
    • 2019
  • Motion generation of a four-bar linkage is a type of mechanism synthesis that has a wide range of applications such as a pick-and-place operation in manufacturing. In this research, the use of meta-heuristics for motion generation of a four-bar linkage is demonstrated. Three problems of motion generation were posed as a constrained optimization probably using the weighted sum technique to handle two types of tracking errors. A simple penalty function technique was used to deal with design constraints while three meta-heuristics including differential evolution (DE), self-adaptive differential evolution (JADE) and teaching learning based optimization (TLBO) were employed to solve the problems. Comparative results and the effect of the constraint handling technique are illustrated and discussed.

Selection of working fluid for cryosurgical probe considering biological heat transfer

  • Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권4호
    • /
    • pp.46-49
    • /
    • 2007
  • This paper describes the sensitive cooling performance change of J-T refrigerator for cryosurgical probe due to its working fluid. The analytical results of using 50 bar nitrous oxide are compared with the case of 300 bar argon. Bio-heat equation is numerically solved to investigate the effect of the probe temperature and the cooling power of the J-T refrigerator. The refrigerator using 50 bar nitrous oxide has larger cooling power above 185 K than the one with 300 bar argon, which enables fast cooling at early stage of cryosurgery, but the biological tissue away from the probe tends to be cooled slowly after the probe reaches its lowest operating temperature. When the repeated freeze-thaw cycle is employed for main tissue destruction mechanism, using high pressure nitrous oxide is more advantageous than argon if the freezing operation is within 2-3 minutes. The probe with high pressure argon is more suitable for the case of longer freeze-thaw cycle with fewer repetitions.

RC 지하구조물의 내구성설계 개선에 관한 연구 (A Study on the Improvement of Durability Design of Underground RC Structures)

  • 임정순;방윤석
    • 한국방재학회 논문집
    • /
    • 제7권4호
    • /
    • pp.13-18
    • /
    • 2007
  • 본 연구에서는 구조물의 내구성 설계 시에 영향을 미치는 설계인자들에 대한 고찰을 하고, 내구성 설계에 사용되고 있는 기준에 대한 국내외 문헌연구를 수행하였으며, 국내기준을 가지고 지하 구조물 단면을 대상으로 내구성 설계를 수행하였다. 국내 지하구조물의 내구설계 지침에 따른 결과는 사용 철근의 직경을 작게 하고 간격을 좁힐수록 구조물의 내구성에 유리한 것으로 나타났으며, 환경지수 제한치를 상회하는 내구지수를 가지기 위해서는 최소한 6.6cm의 피복을 가져야 하며, 내구지수와 내구지수 증분치 변화의 최대 철근피복은 12cm인 것으로 나타났다. 별도의 제한규정이 없는 경우, 철근피복의 최소치와 최대치 사이에서 중성화로 인한 내구연한은 철근피복에 비례하였다.

Pullout Test of Headed Reinforcing Bar in RC or SFRC Members with Side-Face Blowout Failure

  • Lee, Chang-Yong;Kim, Seung-Hun;Lee, Yong-Taeg
    • Architectural research
    • /
    • 제22권1호
    • /
    • pp.33-39
    • /
    • 2020
  • In this study, side-face blowout failure strength of high strength headed reinforcing bar, which is vertically anchoring between RC or SFRC members, is evaluated throughout pullout test. The major test parameters are content ratio of high strength steel fibers, strength of rebar, length of anchorage, presence of shear reinforcement, and the side concrete cover thickness planned to be 1.3 times of the rebar. In pullout test, tensile force was applied to the headed reinforcing bar with the hinged supports positioned 1.5 and 0.7 times the anchorage length on both sides of the headed reinforcing bar. As a result, the cone-shaped crack occurred where the headed reinforcing bar embedded and finally side-face blowout failure caused by bearing pressure of the headed reinforcing bar. The tensile strength of specimens increased by 13.0 ~26.2% with shear reinforcement. The pullout strength of the specimens increased by 3.6 ~15.4% according to steel fiber reinforcement. Increasing the anchoring length and shear reinforcement were evaluated to reduce the stress bearing ration of the total stress.

Bar Fraction in Early-type and Late-type

  • Lee, Yun Hee;Ann, Hong Bae;Park, Myeong-Gu
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.43.4-44
    • /
    • 2017
  • Bar fractions depend on the properties of host galaxies. However, the observational studies did not provide consistent tendency. We investigated the bar fractions and their dependence on properties of host galaxies using three bar classifications: visual inspection, ellipse fitting method and Fourier analysis from a volume-limited sample of 1,698 disk galaxies brighter than Mr=-15.2 within z = 0.01 from the Sloan Digital Sky Survey (SDSS) Data Release 7 (DR7). We found two causes to make the discrepancy in previous studies. One is caused by the difficulty in automatically identifying bars for bulge-dominated galaxies. In particular, ellipse fitting methods could miss early-type barred galaxies when a large bulge weakens the transition between a bar and disk. The other is caused by the difference in the correlation between the bar types and host morphology for strong bars and weak bars. Strong bars are preponderant in early-type spirals which are red, bulge-dominated and highly concentrated, whereas weak bars are frequent in late-type spirals which are blue, disk-dominate and less-concentrated. Therefore, how much weak bars they contain affects the trend of bar fraction on host galaxy properties. We also discuss the effect of host properties on the formation, evolution, and destruction of bars.

  • PDF

가스차단기 모선부의 온도상승 예측 프로그램 개발 (Development of the Temperature Prediction Program for the Bus Bar of a Gas-insulated Switchgear)

  • 함진기;김영기;이희원;김진수;송석현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.169-174
    • /
    • 2003
  • The thermal design of the bus bar of a Gas-Insulated Switchgear(GIS) becomes important since the current-carrying capacity of the GIS is limited by maximum operating temperature. In order to predict temperature rise of the bus bar, a program has been developed. Various heat sources possibly generated in the bus bar are calculated in the program. To estimate temperature rises at the bus bar caused by the heat balance between the heat generation and heat transfer, the finite volume method as well as the $4^{th}$ order Runge-Kutta method has been employed. In the experiments, temperature rises at conductor, contact part and external tank are measured for full-scale gas-insulated bus bars. The comparisons of the predicted values of the heat balance calculation to those of the experiments are made. From the comparisons, it is concluded that the developed program can predict the temperature rise of the bus bar quite well.

  • PDF

스트레인 게이지를 이용한 임플랜트 지지 오버덴춰의 응력분석 (A STRESS ANALYSIS OF THE IMPLANT - SUPPORTED OVERDENTURE USING STRAIN GAUGE)

  • 조혜원;권주홍;이화영
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.93-103
    • /
    • 1999
  • Stress distribution on mandibular implants supporting overdentures were registered in vitro experimental model by means of 4 rosette gauges which were placed around the implant. The overdenture attachments used in this study were the Resilient Dolder bar, Rigid Bolder bar, Round bar, Hader bar & Dal-Ro attachment. An occlusal jig was placed on the overdenture and the loading sites were 3 points which mimicked working, balancing, and median relations. With 5 and 10kg loading, strains were measured by strain indicator(P-3500, Measurement group, Raleigh, USA), and using these data, maximum and minimum principal stresses and Von Mises stress were calculated and evaluated. The results were as follows : There was a tendency of high stress concentration in the lingual side of the implant, and in the buccal side low stress was developed regardless of the attachment systems. The resilient Bolder bar concentrated highest stress among the attachment systems, and the Round bar and the Dal-Ro attachment provided comparatively low stresses around the implant. The rigid Bolder bar concentrated high stress in the mesial side, and the Dal-Ro attachment developed tensile stress patterns in the lingual and distal sides of the implant at the balancing relation.

  • PDF