• Title/Summary/Keyword: 4 probe measurement

Search Result 310, Processing Time 0.028 seconds

Effects of Maximum Probe Spacing of Soil Resistivity Survery on Substation Grounding Analysis (변전소 접지설계를 위한 대지저항율 측정시 전극간 최대간격이 접지해석에 미치는 영향)

  • 정길조;곽희로;최종기
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.382-386
    • /
    • 2001
  • Presently, typical maximum probe spacing of soil resistivity survey(Wenners 4 pin method) is 20 m in case of 154 K substation grounding design of KEPCO. This paper examined the effects of maximum probe spacing of wenner method on the equivalent soil modeling and the accuracy of grounding resistance measurement by comparing the calculated FOP(Fall-of-Potential) curves of various soil models with the measured one at 154kV H substation. The comparison results showed that the inaccurate estimation of deep soil resistivity, which is caused from the short probe spacing of soil resistivity survey, can produce large errors on measurement of grounding resistance. In this paper a quantitative analysis of FOP at H substation has been presented.

  • PDF

A Study on Non-contact Measurement of 3D-Objects by Optical Probe Method (광촉침법에 의한 비접촉 3차원 형상측정에 관한 연구)

  • Kang, Young-June;Shin, Seong-Kook;Miyoshi, Takashi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.4
    • /
    • pp.119-126
    • /
    • 1995
  • This paper presents a non-contact measuring system using one point measuring method to measure surface profiles of dies and clay models for practical use in the field of production engineering. The system has a laser beam probe similar to a measuring probe in a contact measuring system and CCD linear sensor used to detect 300mm measurement range, displacement of measured surfaces, from an origin. There is no mechanical interference between this measuring system and a measured surface in this system. In this measuring system, it was needed 500-600ms including data processing time to measure one point. The experiments showed that the standard deviation was 800 .mu.m and the reproducibility was also 100-210 .mu. m.

  • PDF

Realization of Non-contact Sheet Resistance Measurement System for LCD using Eddy Current Probe (와전류탐침을 이용한 LCD용 비접촉식 면적저항 측정기의 구현)

  • 강신혁;최재훈황호정
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.617-620
    • /
    • 1998
  • In this paper we realized non-contact sheet resistance measurement system using eddy current. Proposed system is designed to meet the requirements which is necessary when dealing with conducting thin films on large area LCD panel. With several metals we could get lift-off curves which has the same trend as in principal. Especially in the region of high conductivity this system has more discriminating ability than 4-point probe system.

  • PDF

Study on the Microwave Dielectric properties in the Dielectric Rod Resonator Method (유전체 원주공진기법에 의한 고주파 유전특성 측정에 관한 연구)

  • Kim, Kyung-Yong;Kim, Wang-Sup;Choi, Hwan
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.471-481
    • /
    • 1995
  • Measurement factors for the dielectric properties of low dielectric loss materials (tan${\dalta}{\le}10^{-4}$) were investigated using the dielectric rod resonator method. It was shown that the relative conductivity (${\sigma}_{r}$) should be controlled within a 5% to obtain the standard deviations of less than 0.07 for permittivity .epsilon.r and 0.06${\times}10^{-4}$ for tan.delta.respectively. Surface resistivity (R$_s$) could be reduced when the surface roughness of parallelled conducting plate was less than 0.07 .mu.m. Measurement error for the permittivity was $\pm$0.02% independent of probe loop size, whereas the error in Q value was reduced with the decrease in probe loop size and also with the increase in the absolute values of Q. Reliable Q values were determined with the probe loop size of less than 4mm. The accurate for the distance between the measuring probe loop and the sample could be obtained when the insertion loss of resonant frequency ranged -15dB - -30dB.

  • PDF

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

Design and Fabrication of Wideband Probe for Efficient Near Field Measurement (근역장의 효율적 측정을 위한 광대역 프로브의 설계 및 제작)

  • Kim Joung-Myoun;Moon Jung-Ick;Yun Je-Hoon;Jeon Soon-Ik;Kim Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.9 s.112
    • /
    • pp.836-844
    • /
    • 2006
  • In this paper, we designed and fabricated the wideband probe with double ridged waveguide for Near-field Measurement. An exponential taper ridge in the rectangular waveguide was implemented for wideband impedance matching. It has wideband characteristics and its measured impedance bandwidth ratio is approximately 2.2:1 from 8.2 GHz to 18 GHz for $VSWR\leq2.2$. It maintains about the same radiation pattern over the entire bandwidth and has more than 4.5 dBi peak radiation gain. Our designed probe was applied to near-field measurement. A good agreement has been found between simulated and measured results.

3-Axial Isotropic Electric-Field Probe Design with Resistor-Loaded Short Dipole (저항 부하된 소형 다이폴을 이용한 3축 등방성 전기장 프로브 설계)

  • Moon, Sung-Won;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.3
    • /
    • pp.246-249
    • /
    • 2017
  • In this paper, we designed the 3-axis isotropic electric-field measurement probe using resistor-loaded short dipole with lumped chip resistors. The designed probe shows good isotropic characteristics as well as wideband and low sensitivity. The isotropic characteristics of ${\pm}0.39dB$ from 100 kHz to the 3 GHz band were derived and the reception sensitivity was 0.1 V/m. The frequency response is within 3 dB of the whole section, especially ${\pm}1.3dB$ from 150 kHz to 3 GHz, which is superior to the conventional electric field probe with short dipoles.

Detection Technique of Partial Discharge by a Capacitive Probe in Cast-resin Transformers (몰드변압기에서 용량성 프로브에 의한 부분방전 검출 기술)

  • Jung, Kwang-Seok;Park, Dae-Won;Cha, Hyeon-Kyu;Cha, Sang-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.319-324
    • /
    • 2011
  • This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]~45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.

The Effects of the Four Point Probe Measurement Technique on the Precision and Accuracy in Electrical Resistivity Measurements. (4탐침 측정기술이 비저항 측정 정밀 정확도에 미치는 영향)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Kim, Han-Jun;Han, Sang-Ok;Kim, Jong-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.267-269
    • /
    • 2003
  • 반도체 웨이퍼 및 각종 박막의 면/비저항(sheet/resistivity resistance)의 측정에 비교적 간단히 측정할 수 있고 측정정확도가 높은 4탐침(four-point probe)방법이 널리 사용되고 있다 또한 4탐침 측정방법은 높은 분해능의 contour map작성과 ion implantation의 doping accuracy 및 doping uniformity의 측정에도 사용된다. 최근 재료의 소형, 박막화 경향으로 볼 때 정확한 비저항 측정의 필요성이 요구되고 있으며 이에 따라 4탐침 측정기술인 single 및 dual configuration method로 실리콘 웨이퍼에 대한 비저항의 측정 정확도를 고찰한 결과 dual configuration 측정방법이 single configuration측정 방법에 비하여 정밀 정확도가 더 좋은 것으로 고찰되었다.

  • PDF