• Title/Summary/Keyword: 3rd harmonic

Search Result 119, Processing Time 0.02 seconds

Design of Ku-Band Phase Locked Harmonic Oscillator (Ku-Band용 위상 고정 고조파 발진기 설계)

  • Lee Kun-Joon;Kim Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.49-55
    • /
    • 2005
  • In this paper, the phase locked harmonic oscillator(PLHO) using the analog PLL(Phase Locked Loop) is designed and implemented for a wireless LAN system. The harmonic oscillator is consisted of a ring resonator, a varactor diode and a PLL circuit. Because the fundamental fiequency of 8.5 GHz is used as the feedback signal for the PLL and the 2nd harmonic of 17.0 GHz is used as the output, a analog frequency divider for the phase comparison in the PLL system can be omitted. For the simple PLL circuit, the SPD(Sampling Phase Detector) as a phase comparator is used. The output power of the phase locked harmonic oscillator is 2.23 dBm at 17 GHz. The fundamental and 3rd harmonic suppressions are -31.5 dBc and -29.0 dBc, respectively. The measured phase noise characteristics are -87.6 dBc/Hz and -95.4 dBc/Hz at the of offset frequency of 1 kHz and 10 kHz from the carrier, respectively.

Bandwidth Enhancement of a Meander Slot Antenna with Harmonic Suppression (고조파 억압 특성을 갖는 미앤더 슬롯 안테나의 대역폭 향상에 관한 연구)

  • Hwang, Kwang-Sun;Kim, Hyung-Rak;Chang, Ki-Hoon;Ha, Jung-Uk;Yoon, Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.9
    • /
    • pp.961-966
    • /
    • 2003
  • Bowtie shaped meander slot antenna with harmonic suppression is designed and demonstrated experimentally. A substrate with height of 0.508 mm and relative permittivity of 2.5 is used, and the fundamental resonant frequency is 5.536 GHz. With thin conductor line in the antenna, harmonic suppression characteristic is obtained, and return losses at the 2nd and 3rd harmonic frequencies are -0.56 dB and -1.9 dB, respectively. Also, bowtie shape is applied to the antenna design for bandwidth enhancement, and the resulting bandwidth is 3.7 %, which is about three times wider than the reported meander slot antenna with harmonic suppression$\^$[1],[2]/.

A Study on the Predistortion Linearizer Controlled by the Individual Order with Frequency Multiplier (주파수 체배기를 이용한 개별 차수 조정 전치왜곡 선형화기의 설계 및 구현)

  • 민준기;이기학;이근태;안창돈;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12A
    • /
    • pp.1019-1024
    • /
    • 2003
  • In the thesis, we propose a new type of the predistortion linearizer using frequency multiplier The linearizer utilizing the 2nd and 3th harmonic used the individual control of the 3rd and 5th order intermodulation distortion(IMD) component. This structure is composed of wilkinson power combiner for combine and isolation of output signal, 3rd order IMD product controller using doubler and 5th order IMD product controller using tripler. The proposed predistortion linearizer controlled by individual order is obtained for about -16 dBc and 18 dBc of 3rd order and 5th order IMD components, respectively, over the frequency band 870 MHz to 880 MHz at the output power of 34 dBm/tone.

Hybrid Series Active Power filter Based on Performance Function Theory for 3-Phase 4-wire System (성능함수제어 알고리즘을 이용한 3상 4선식 하이브리드형 직렬능동전력필터)

  • Kim, Jin-Sun;Shin, Jae-Hwa;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1096-1098
    • /
    • 2003
  • In this paper, the control algorithm and control methods for a combined system of shunt passive filter and series active filter in 3-phase 4-wire system are discussed. Moreover, the 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and odd multiples of $3^{rd}$($9^{th}$, $15^{th}$, etc.) are termed as triple and zero sequence components that do not cancel each other in the system neutral. As a result, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control scheme for a series hybrid active system. This series active power filter acts not only as a harmonic compensator but also as a harmonic isolator. Hence the required rating of the series active filter is much smaller than that of a conventional shunt active filter. However, the performance of the combined system is greatly influenced by the filtering algorithm employed in the active power filter. This paper proposes a series active power filter scheme based on performance function. Some experiments was executed and experimental results from a prototype active power filter confirm the suitability of the proposed approach.

  • PDF

Design of a GaN HEMT Power Amplifier Using Output Matching Circuit with Arbitrary Harmonic Impedances (임의의 고조파 임피던스를 갖는 출력 정합 회로를 이용한 GaN HEMT 전력증폭기의 설계)

  • Jeong, Hae-Chang;Son, Bom-Ik;Lee, Dong-Hyun;Ahmed, Abdul-Rahman;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1034-1046
    • /
    • 2013
  • In this paper, a design of a GaN HEMT power amplifier using output matching circuit with arbitrary harmonic impedances is presented. The adopted GaN HEMT device, TGF2023-02 of TriQuint Semiconductor, was packaged in commercial package. The optimal impedances of the GaN HEMT package are extracted from load-pull simulation at package input and output reference planes. The targets of load-pull simulation are the highest output power at fundamental frequency and the highest efficiency at $2^{nd}$ and $3^{rd}$ harmonic frequencies. Because of fixture in the package, the extracted impedances shows arbitrary harmonic impedances. In order to match the optimal impedances, output matchin circuit which has 4 transmission lines is presented. Characteristic impedances and electrical lengths of the transmission lines are mathmatically calculated. The power amplfiier with $54.6{\times}40mm^2$ shows the output power of 8 W at the fundamental frequency of 2.5 GHz, the efficiency above 55 %, and harmonic suppression of above 35 dBc at the $2^{nd}$ and the $3^{rd}$ harmonics.

MRSF-PWM Method for Acoustic Noise Reduction of Traction Motor Drive Systems (견인전동기 구동시스템의 소음 저감을 위한 MRSF-PWM 방식)

  • 홍순찬;서영민
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.262-271
    • /
    • 2002
  • In PWM inverters used in traction motor drive systems, the switching frequency is restricted by their large power capacity and thus the electromagnetic acoustic noise is generated. To reduce such an audible noise, the new MRSF-PWM(Modified Random Switching Frequency PWM) method is proposed. In the Proposed MRSF-PWM method, both triangular wave and sawtooth wave are used together as carrier waves for harmonic diffusion and reference wave is generated by injecting 3rd harmonic into the stone wave to expand the linear control region of output voltages. To verify the validity of the proposed MRSF-PWM method, computer simulations are carried out. And the results show that the MRSF-PWM method is more excellent than other RPWM methods in the aspects of both linearity and harmonic diffusion md more effective than SPWM(Sinusoidal PWM) method for the reduction of an audible noise.

One to one Resonance on the Rectangular Cantilever Beam (사각형 외팔보에서의 일대일 공진)

  • Kim, Myoung-Gu;Pak, Chul-Hui;Cho, Chong-Du;Lee, Heung-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.424-429
    • /
    • 2005
  • In this paper, the response characteristics of one to one resonance on the rectangular cantilever beam in which basic harmonic excitations are applied by nonlinear coupled differential integral equations are studied. This equations have 3-dimensional non-linearity of nonlinear inertia and nonlinear curvature. Galerkin and multi scale methods are used for theoretical approach to one to one internal resonance. Nonlinear response characteristics of 1st, 2nd, 3rd modes are measured from the experiment for basic harmonic excitation. From the experimental result, geometrical terms of nonlinearity display light spring effect and these terms play an important role in the response characteristics of low frequency modes. Dynamic behaviors in the out of plane are also studied.

  • PDF

One to One Resonance on the Quadrangle Cantilever Beam (정사각형 외팔보에서의 일대일 공진)

  • Kim, Myoung-Gu;Pak, Chul-Hui;Cho, Chong-Du
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.7 s.100
    • /
    • pp.851-858
    • /
    • 2005
  • The response characteristics of one to one resonance on the quadrangle cantilever beam in which basic harmonic excitations are applied by nonlinear coupled differential-integral equations are studied. This equations have 3-dimensional non-linearity of nonlinear inertia and nonlinear curvature. Galerkin and multi scale methods are used for theoretical approach to one-to-one internal resonance. Nonlinear response characteristics of 1st, 2nd, 3rd modes are measured from the experiment for basic harmonic excitation. From the experimental result, geometrical terms of non-linearity display light spring effect and these terms play an important role in the response characteristics of low frequency modes. Nonlinear nitration in the out of plane are also studied.

An Experimental Study on the Characteristics for Open-Tube and Closed-Tube Thermoacoustic Effects (2)- The 2nd, 3rd Harmonic (개방관과 밀폐관의 열음향 효과에 관한 하모닉 특성 연구(2) - 2차, 3차 하모닉)

  • 송규조;박종호;이성노
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.135-139
    • /
    • 2002
  • In this study, the experimental open-tube and close-tube thermoacoustic apparatuses were built. In order to determine the optimum length of resonant tube and the optimum length of stack, the resonant characteristics of thermoacoustic apparatuses were investigated, The length of resonant tube varies from 400mm to 850mm. The experimental frequency varies from 100Hz to 1000Hz. In case of the second and third harmonics, the maximum temperature difference of open-tube thermoacoustic apparatus is 53$^{\circ}C$ (resonator length: 400mm) and the maximum temperature difference of closed-tube thermoacoustic apparatus is 51$^{\circ}C$ (resonator length: 500mm). In the open-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 55%, 69% in the resonant tube and in the closed-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 41%, 50% in the resonant tube.

A Parameters Estimation of Five-phase Induction Motor (5상 유도전동기의 파라미터 추정)

  • Kim, Nam-Hun;Baik, Won-Sik;Kim, Min-Huei;Jung, Hyung-Woo;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.55-56
    • /
    • 2010
  • 다상 유도 전동기(Multi phase induction motor)의 고성능 제어를 수행하기 위해서는 정확한 파라미터 계산이 필수적이다. 특히 전동기의 벡터제어(FOC, Field oriented control)나 직접토크제어(DTC, Direct torque control)와 같은 고성능 제어 시스템의 경우, 슬립 계산이나 자속관측기 그리고 PI 제어기 게인 추정에서 전동기 상수들이 필수적으로 사용된다. 본 논문에서는 실험용으로 집중권(Concentrated winding) 구조를 가지는 2kW, 5상 유도전동기를 제작하였으며, 5상 유도전동기 파라미터 추정에 대한 방법을 제시하였다. 일반적으로 다상 유도전동기의 경우 1차 공간 고조파(1st space harmonic) 성분에 대한 파라미터만을 추정하여 제어에 사용하지만, 본 논문에서는 1차 공간 고조파 성분과 3차 공간 고조파(3rd space harmonic) 성분에 대한 파라미터 추정 방법을 제시한다. 결과적으로 제안된 파라미터 추정 방법의 타당성을 확인하기 위해서 설계값과 실험값을 비교하였다.

  • PDF