• 제목/요약/키워드: 3d photo scanner

검색결과 9건 처리시간 0.03초

고정밀 측량장비(3D 레이저 스캐너, 3D 포토 스캐너, 드론)를 활용한 건축 시공단계의 엔지니어링 적용사례 (Engineering Construction With High-Precision Survey Equipment (3D laser scanner, 3D photo scanner, drone))

  • 정광량;이병도;김태혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2019
  • As information and construction technology increases, the demand for sophisticated geometric design grows. Design of buildings is becoming more larger, higher, and complicated every day, requiring much new construction technology to bring the design into reality. Nonetheless, the speed of construction technology development is not as rapid. This study concerns the difficulties of realization of sophisticated geometric design. It aims to suggest using BIM and precision survey equipment during the construction stage of the project is a way to resolve. The study will list how to use BIM as an engineering platform incorporating a photo scanner, a scanner drone, and a 3D scanner in the construction stage of projects, how these progressive projects were able to benefit from the high-construction technology.

  • PDF

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

A standardization model based on image recognition for performance evaluation of an oral scanner

  • Seo, Sang-Wan;Lee, Wan-Sun;Byun, Jae-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.409-415
    • /
    • 2017
  • PURPOSE. Accurate information is essential in dentistry. The image information of missing teeth is used in optically based medical equipment in prosthodontic treatment. To evaluate oral scanners, the standardized model was examined from cases of image recognition errors of linear discriminant analysis (LDA), and a model that combines the variables with reference to ISO 12836:2015 was designed. MATERIALS AND METHODS. The basic model was fabricated by applying 4 factors to the tooth profile (chamfer, groove, curve, and square) and the bottom surface. Photo-type and video-type scanners were used to analyze 3D images after image capture. The scans were performed several times according to the prescribed sequence to distinguish the model from the one that did not form, and the results confirmed it to be the best. RESULTS. In the case of the initial basic model, a 3D shape could not be obtained by scanning even if several shots were taken. Subsequently, the recognition rate of the image was improved with every variable factor, and the difference depends on the tooth profile and the pattern of the floor surface. CONCLUSION. Based on the recognition error of the LDA, the recognition rate decreases when the model has a similar pattern. Therefore, to obtain the accurate 3D data, the difference of each class needs to be provided when developing a standardized model.

디지털 영상자료를 이용한 3D GIS의 사실적 모델링 및 가시화 (Application of Photo-realistic Modeling and Visualization Using Digital Image Data in 3D GIS)

  • 정성혁;이재기
    • 한국측량학회지
    • /
    • 제26권1호
    • /
    • pp.73-83
    • /
    • 2008
  • 국토 및 도시정보의 공간분석과 의사결정을 위하여 디지털 영상자료를 이용한 3D GIS와 구축된 3D 도형정보를 현실적으로 가시화하기 위한 사실적 3D 영상모형(3D photo-realistic model)에 관한 기술이 급속히 발전하고 있다. 현재, 3D 모형 구축을 위하여 위성영상, 항공영상 및 항공라이다 데이터가 주로 이용되고 있으며, 항공경사사진 또는 지상사진에서 취득된 텍스쳐를 이용하여 3D 영상모형을 구축하고 있다. 그러나, 상기 데이터만을 이용하여 구축된 모형은 지형 및 지물을 세밀하고 사실감 있게 표현하는데 제한적이기 때문에 고품질의 영상모형 구축이 필요한 실정이다. 따라서, 본 연구에서는 인공지물과 특수지형을 대상으로 공간정확도, 세밀묘사 및 현실감이 강조된 실세계에 근접한 3D 영상모형을 구축하기 위하여 항공사진, 항공라이다, 지상사진 및 지상라이다 데이터로 실세계를 표현하기 위한 기법을 분석하고, 위치정확도와 함께 사진과 같은 사실감을 확보한 3D 영상모형을 구축하고 인터넷 3D 영상지도 서비스를 통하여 제공할 수 있도록 하였다. 또한, 3D 영상모형은 이용목적 및 디스플레이 축척에 따라 표현요소를 구분하여 구축할 필요가 있으며, 본 연구에서는 LoD(Level of Detail) 개념을 도입하여 건물 3D 영상모형을 5단계로 정의하고 단계별로 모형을 구축하였다.

SLS 공정을 이용한 산업용 임의형상 제작시스템에 관한 연구 (A Study on the Industrial Type SFF System using SLS Proecss)

  • 김동수;임현의;김성종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1299-1302
    • /
    • 2004
  • A real object duplication system (RODS), including three dimensional (3D) scanner and solid freeform fabrication system (SFFS), is a device to make three-dimensional objects directly from the drawing or photo data. A Selective Multi-Laser Sintering (SMLS) process designed in this paper is by which computer images received using 3D scanner are built up from polymer powder on building room of large size using dual laser at industrial type SFF system. Using the process can rapidly produce real object duplication components of industrial type such as cylinder, engine block, chassis of automobile, etc. In this paper, the industrial type SFF system using SMLS process is manufactured and the system is satisfied with high precision and high speed processing technique. To research characteristics of each part for theindustrial type SFF system, a structure and thermal analysis and test of each part is carried out. Also, to achievement of high performance for industrial type SFF system, design and fabrication for the structure, heater, nitrogen supply, laser and control part are carried out.

  • PDF

매장문화재 자료에 대한 3D 디지털 기록 결과 비교연구 (A Relative Study of 3D Digital Record Results on Buried Cultural Properties)

  • 김수현;이승연;이정원;안형기
    • 헤리티지:역사와 과학
    • /
    • 제55권1호
    • /
    • pp.175-198
    • /
    • 2022
  • 기술의 발전과 더불어 다양한 형태의 아날로그 정보를 디지털로 변환하는 방법이 보편화되었다. 그 결과 디지털 유산, 디지털 재건과 같이 가상공간 내에 데이터를 기록하고 구축하여 재생산하는 개념이 정립되면서 다양한 문화유산 보존과 연구에 적극적으로 활용되고 있다. 그러나 중소형 유물에 대한 최적의 스캐너를 제시하는 기존 연구 성과는 거의 없는 실정이다. 또한 스캐너 가격도 연구자들이 활용하기에는 저렴하지 않아 관련 연구가 많지 않다. 3D 스캐너 사양은 3D 모델 품질에 큰 영향을 끼친다. 특히 스캐너에서 사용되는 광원의 종류에 따라 물체 표면에서 반사되는 빛의 상태가 상이하므로 객체의 특성에 적합한 스캐너를 사용하는 것이 작업의 효율성을 올릴 수 있는 방법이다. 따라서 본고에서는 시기별 토기와 자기를 비롯한 다양한 재질의 중소형 매장문화재 9점을 대상으로 연구를 진행하여 네 가지 방식의 3D 스캐너가 어떠 품질 차이가 있는지 살펴보고자 하였다. 연구 결과 중소형 유물의 디지털 기록은 광학식 스캐너와 중소형 오브젝트 스캐너가 가장 적합하였다. 광학식 스캐너는 메시와 텍스처 모두 우수하나, 가격이 매우 높으며 휴대성이 떨어진다는 단점이 있다. 핸드헬드 방식은 휴대성과 신속성이 뛰어나다는 장점이 있었다. 가격 대비 결과물을 고려할 때는 중소형 오브젝트 스캐너가 가장 우수하였다. 가장 저렴한 비용으로 3D 모델을 획득할 수 있었던 것은 사진실측이었다. 3D 스캐닝 기술은 크게 유물의 디지털 도면 제작, 문화재 복원 및 복제, 데이터베이스 구축 방면으로 활용할 수 있다. 본 연구는 문화유산에서 3D 스캐닝 기술의 적극적인 활용을 위해 재질별, 시대별 매장문화재 유물에 가장 적합한 스캐너를 이용할 수 있도록 기여하였다는 데에 의의가 있다.

VLBI 안테나와 모바일폰 카메라를 활용한 근접수치사진측량의 캘리브레이션 초기값 결정에 따른 3차원 정확도 분석 (Analysis of 3D Accuracy According to Determination of Calibration Initial Value in Close-Range Digital Photogrammetry Using VLBI Antenna and Mobile Phone Camera)

  • 김혁길;윤홍식;조재명
    • 한국측량학회지
    • /
    • 제33권1호
    • /
    • pp.31-43
    • /
    • 2015
  • 본 논문에서는 세종시 우주측지관측센터에 위치한 VLBI 안테나를 대상으로 모바일폰 카메라의 캘리브레이션을 수행하고, 촬영된 스테레오 영상으로부터 3차원 위치좌표를 산출하였다. 모바일폰에 탑재된 카메라의 캘리브레이션을 위한 초기값으로 DLT방법과 상용 수치사진측량시스템인 PhotoModeler $Scanner^{(R)}$ ver. 6.0을 활용하였다. DLT와 PhotoModeler방법으로 산출한 표정결과를 초기값으로 사용하여 광속조정을 통해 카메라 내 외부 표정요소를 계산하고, 두 결과의 정확도를 비교하였다. 두 가지 방법으로 산출한 표정결과는 상당한 편차가 발생하지만, 비선형의 공선조건식을 이용한 광속조정계산으로 두 가지 방법의 최종 표정결과가 거의 일치함을 알 수 있었다. 또한, 두 가지 방법으로 결정된 카메라 내 외부 표정요소들을 이용하여 VLBI 안테나 특징점에 대한 3차원 좌표를 계산하고 토탈스테이션을 통해 측정된 기준좌표들과 비교하였다. 그 결과, 두 가지 방법 모두 표준편차가 $X=0.004{\pm}0.010m$, $Y=0.001{\pm}0.015m$, $Z=0.009{\pm}0.017m$로서, cm급의 높은 정확도를 나타내었다. 이러한 결과를 통해 정밀 사진측량의 목적이 아닌 허용오차의 범위가 상대적으로 큰 다양한 사진측량 분야에 모바일폰 카메라를 활용할 수 있을 것이라 판단된다.

맵핑용 3차원 영상 레이저 레이다의 시스템 설계 및 성능 분석 (System Design and Performance Analysis of 3D Imaging Laser Radar for the Mapping Purpose)

  • 라종필;고진신;이창재
    • 한국군사과학기술학회지
    • /
    • 제17권1호
    • /
    • pp.90-95
    • /
    • 2014
  • The system design and the system performance analysis of 3D imaging laser radar system for the mapping purpose is addressed in this article. For the mapping, a push-bloom scanning method is utilized. The pulsed fiber laser with high pulse energy and high pulse repetition rate is used for the light source of laser radar system. The high sensitive linear mode InGaAs avalanche photo-diode is used for the laser receiver module. The time-of-flight of laser pulse from the laser to the receiver is calculated by using high speed FPGA based signal processing board. To reduce the walk error of laser pulse regardless of the intensity differences between pulses, the time of flight is measured from peak to peak of laser pulses. To get 3D image with a single pixel detector, Risley scanner which stirs the laser beam in an ellipsoidal pattern is used. The system laser energy budget characteristics is modeled using LADAR equation, from which the system performances such as the pulse detection probability, false alarm and etc. are analyzed and predicted. The test results of the system performances are acquired and compared with the predicted system performance. According to test results, all the system requirements are satisfied. The 3D image which was acquired by using the laser radar system is also presented in this article.

중형카메라 RCD105 정확도 분석 (Accuracy Analysis of Medium Format CCD Camera RCD105)

  • 김태훈;원재호;김충평;소재경;윤희천
    • 한국측량학회지
    • /
    • 제28권4호
    • /
    • pp.449-454
    • /
    • 2010
  • 최근 항공측량분야에서 항공디지털카메라 및 항공레이저측량시스템은 수치정사영상지도 및 수치표고모델제작 등의 지리정보 구축에 활용되고 있다. 본 연구에서는 항공레이저측량시스템인 ALS50-II에 구성된 중형CCD카메라 RCD105의 3차원 위치정확도를 디지털항공사진카메라인 DMC와 비교하였다. 이를 위해 연구지역을 선정하고 항공사진촬영을 실시하였으며, 축적 1:1,000 수치지형도에서 항공삼각측량에 사용할 지상기준점과 수치도화기를 이용해 평면 및 수준정확도 검증에 사용할 검사점을 선점하였다. RCD105와 DMC의 정확도는 항공삼각측량의 결과와 수치도화기를 이용해 검사점과 동일한 지점을 관측한 결과로 평가하였다. 항공삼각측량 결과 RCD105의 X, Y, Z RMSE (Root Mean Square Error)가 DMC보다 각각 2.1배, 2.2배, 1.3배 크게 나타났다. 또한 수치도화기를 이용해 검사점을 관측한 결과 RCD105의 평면 및 수직방향 RMSE가 DMC보다 각각 2.5배, 4.3배 크게 나타났다. RCD105의 정확도가 DMC보다는 떨어지지만, RCD105도 수치지형도 및 정사사진 제작에 활용이 가능할 것으로 사료된다.