• Title/Summary/Keyword: 3d Scan

Search Result 879, Processing Time 0.036 seconds

Scientific Study on Clepsydra of Changgyeonggung Palace, National Treasure for Diagnosis on State of Conservation (국보 창경궁 자격루 누기의 보존상태 진단을 위한 과학적 조사)

  • YOU Harim;LEE Jaesung;YU Jia;JO Hanui;PARK Younghwan;RYU Dongwan
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.3
    • /
    • pp.138-156
    • /
    • 2023
  • Some of the metal cultural heritage that make up a considerable proportion of Korea's cultural heritage have been installed and displayed outdoors due to their own functions, roles, and scale. Therefore, more diverse and complex damages can occur outdoors than they are in a stable environment. Therefore, it is necessary to combine accurate diagnosis and systematic survey methods in order to utilize basic data obtained from research results as data for the long-term and continuous conservation management as well as to do the research to diagnose the conservation status of outdoor cultural heritage. The clepsydra(hereinafter referred to as Jagyeongnu) of Changgyeonggung Palace, the National Treasure has been installed and displayed outdoors since it was manufactured. Though regular conservation and maintenance of the Jagyeongnu have been carried out, damage still occurred. Therefore, the scientific research on Jagyeongnu to diagnose the state of conservation was conducted prior to the full-scale conservation treatment. First, the state of conservation was investigated with an examination of basic data, macroscopic inspections and past records of repair history according to the purpose of the research. More detailed examinations were also conducted through the 3D scan, surface pattern investigation, and color difference analysis, and the analysis on materials and contaminants were conducted through P-XRF, FT-IR, and Py-GC/MS. The scientific research reveals that squalane and silicone oil have been applied in the past for conservation treatment and directly exposed to outdoor environmental factors, which caused damage to Jagyeongnu and contaminants such as dust adhered thickly to its surface, accelerating severe damage. A greater incidence of damage was found around the part with relatively high exposure effect, which corresponded with the tendency identified by grouping color difference data. As a result of integrating various research methodologies to diagnose the state of conservation and secure basic data, the causes and types of damage were identified. Furthermore, the process of obtaining digital data to be utilized in various ways, and the color difference analysis presenting visible damage as scientific data and identifying the tendency of damage patterns were confirmed to have been effective.

A new Clustering Algorithm for the Scanned Infrared Image of the Rosette Seeker (로젯 탐색기의 적외선 주사 영상을 위한 새로운 클러스터링 알고리즘)

  • Jahng, Surng-Gabb;Hong, Hyun-Ki;Doo, Kyung-Su;Oh, Jeong-Su;Choi, Jong-Soo;Seo, Dong-Sun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.2
    • /
    • pp.1-14
    • /
    • 2000
  • The rosette-scan seeker, mounted on the infrared guided missile, is a device that tracks the target It can acquire the 2D image of the target by scanning a space about target in rosette pattern with a single detector Since the detected image is changed according to the position of the object in the field of view and the number of the object is not fixed, the unsupervised methods are employed in clustering it The conventional ISODATA method clusters the objects by using the distance between the seed points and pixels So, the clustering result varies in accordance with the shape of the object or the values of the merging and splitting parameters In this paper, we propose an Array Linkage Clustering Algorithm (ALCA) as a new clustering algorithm improving the conventional method The ALCA has no need for the initial seed points and the merging and splitting parameters since it clusters the object using the connectivity of the array number of the memory stored the pixel Therefore, the ALCA can cluster the object regardless of its shape With the clustering results using the conventional method and the proposed one, we confirm that our method is better than the conventional one in terms of the clustering performance We simulate the rosette scanning infrared seeker (RSIS) using the proposed ALCA as an infrared counter countermeasure The simulation results show that the RSIS using our method is better than the conventional one in terms of the tracking performance.

  • PDF

The accuracy evaluation of digital surgical stents according to supported type (디지털 수술용 가이드의 지지타입에 따른 정확도 평가)

  • Lee, Junyoun;Yoon, Minho;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. Materials and methods: 5 sets of dental models which have tooth supported edentulous area and tooth-tissue supported edentulous area were made. Dental model were scanned with model scanner, and CBCT was taken. CT data and model scan data were overlapped using In2Guide software, implant were virtually planned in the software. Surgical stents are fabricated by 3D printing. The implant fixture were installed using the surgical stent, CBCT were retaken. CBCT before surgery and after surgery were overlapped, and the differences (angle difference, coronal difference, apical difference) were evaluated using statistical analysis. Results: In the assessment of the accuracy of surgical guides according to arch type, there are no statistically significant differences between maxilla and mandible. In the case of support type, tooth supported stents showed lower angle difference and length difference than tooth-tissue supported stents, which are statistically significant. Conclusion: Arch type does not affect the accuracy of surgical stents. But tooth support stents are more accurate than tooth-tissue support stents in the case of angle and length difference.

Usefulness of a FDG-PET Scan in Assessing Recurrent Gastric Cancer (재발한 위암의 진단에 사용된 FDG-PET의 유용성)

  • Lee Hyeon Kook;Lee Kyu Eun;Kim Yoon Ho;Jeong Jae Min;Yang Han-Kwang;Chung June Key;Lee Kuhn Uk;Choe Kuk Jin
    • Journal of Gastric Cancer
    • /
    • v.1 no.3
    • /
    • pp.174-179
    • /
    • 2001
  • Purpose: For curative resection of recurrent gastric cancer, it is imperative that there be no unrecognized foci of tumoral disease outside the operation field. PET (positron emission tomography) with FDG (18 fluoro-2 deoxy-D-glucose) is a whole-body imaging technique that exploits the increased rate of glycolysis in tumor cells to detect disease. The authors evaluated the usefulness of FDG-PET in assessing resectability of recurrent gastric cancer. Materials and Methods: Seven patients with recurrent gastric cancer were studied with FDG-PET from December 1998 to October 2000. All FDG-PET images were interpreted in conjunction with conventional diagnostic methods. All imaging results were correlated with the pathological diagnosis and clinical outcome. Results: A final diagnosis of recurrence was obtained at 14 sites in all 7 patients by histology or clinical follow up. Locoregional recurrence, including distant metastasis, developed in 6 of 7 patients and distant recurrence in only one. FDG-PET detected all recurrent sites (5 locoregional and 5 distant) in 5 patients without peritoneal recurrence, but did not detect peritoneal seeding in 2 patients with peritoneal recurrence. The accuracy of FDG-PET in estimating resectability was $71.4\%$ (5/7), and that of CT and PET together was $85.7\%$ (6/7). A curative resection could be performed in three of the recurrent patients (2 locoregional and 1 distant recurrence). Conclusion: Our results suggest that FDG-PET may be useful for detecting locoregional and distant recurrence of gastric cancer and for selecting appropriate treatment. However, considering that FDG-PET was limited in detecting peritoneal seeding and determining the exact anatomical extension of tumor, it should be used in conjunction with other anatomical images.

  • PDF

A Major Locus for Quantitatively Measured Shank Skin Color Traits in Korean Native Chicken

  • Jin, S.;Lee, J.H.;Seo, D.W.;Cahyadi, M.;Choi, N.R.;Heo, K.N.;Jo, C.;Park, H.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.11
    • /
    • pp.1555-1561
    • /
    • 2016
  • Shank skin color of Korean native chicken (KNC) shows large color variations. It varies from white, yellow, green, bluish or grey to black, whilst in the majority of European breeds the shanks are typically yellow-colored. Three shank skin color-related traits (i.e., lightness [$L^*$], redness [$a^*$], and yellowness [$b^*$]) were measured by a spectrophotometer in 585 progeny from 68 nuclear families in the KNC resource population. We performed genome scan linkage analysis to identify loci that affect quantitatively measured shank skin color traits in KNC. All these birds were genotyped with 167 DNA markers located throughout the 26 autosomes. The SOLAR program was used to conduct multipoint variance-component quantitative trait locus (QTL) analyses. We detected a major QTL that affects $b^*$ value (logarithm of odds [LOD] = 47.5, $p=1.60{\times}10^{-49}$) on GGA24 (GGA for Gallus gallus). At the same location, we also detected a QTL that influences $a^*$ value (LOD = 14.2, $p=6.14{\times}10^{-16}$). Additionally, beta-carotene dioxygenase 2 (BCDO2), the obvious positional candidate gene under the linkage peaks on GGA24, was investigated by the two association tests: i.e., measured genotype association (MGA) and quantitative transmission disequilibrium test (QTDT). Significant associations were detected between BCDO2 g.9367 A>C and $a^*$ ($P_{MGA}=1.69{\times}10^{-28}$; $P_{QTDT}=2.40{\times}10^{-25}$). The strongest associations were between BCDO2 g.9367 A>C and $b^*$ ($P_{MGA}=3.56{\times}10^{-66}$; $P_{QTDT}=1.68{\times}10^{-65}$). However, linkage analyses conditional on the single nucleotide polymorphism indicated that other functional variants should exist. Taken together, we demonstrate for the first time the linkage and association between the BCDO2 locus on GGA24 and quantitatively measured shank skin color traits in KNC.

Fabrication of PCL Scaffolds According to Various Pore Patterns Using Polymer Deposition System and Design of Experiments (폴리머 적층 시스템과 실험계획법을 이용한 다양한 공극 패턴에 따른 PCL 인공지지체의 제작 연구)

  • Sa, Min-Woo;Choi, Sun-Woong;Lee, Jae-Wook;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.645-653
    • /
    • 2017
  • In bone tissue engineering, polycaprolactone (PCL) is one of the most widely used biomaterials in the manufacturing of scaffolds as a synthetic polymer having biodegradability and biocompatibility. The strut width in the fabrication of scaffolds is an important part of tissue regeneration in in-vitro and in-vivo experiments, because it affects not only the pore size but also the porosity. In this study, we used polymer deposition system (PDS) and design of experiments (DOE) to explore the optimal process conditions to achieve a systematic and efficient scaffold manufacturing process, using temperature, pressure, scan velocity, and nozzle tip height as the parameters for the experiments. The aim of this research was to fabricate a 3D PCL scaffold having a uniform strut width of $150{\mu}m$ using DOE; it was proved that the strut width was constant in all the experimental groups by fabricating the PCL scaffolds according to various pore patterns as well as one pore pattern.

Fast Motion Artifact Correction Using l$_1$-norm (l$_1$-norm을 이용한 움직임 인공물의 고속 보정)

  • Zho, Sang-Young;Kim, Eung-Yeop;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2009
  • Purpose : Patient motion during magnetic resonance (MR) imaging is one of the major problems due to its long scan time. Entropy based post-processing motion correction techniques have been shown to correct motion artifact effectively. One of main limitations of these techniques however is its long processing time. In this study, we propose several methods to reduce this long processing time effectively. Materials and Methods : To reduce the long processing time, we used the separability property of two dimensional Fourier transform (2-D FT). Also, a computationally light metric (sum of all image pixel intensity) was used instead of the entropy criterion. Finally, partial Fourier reconstruction, in particular the projection onto convex set (POCS) method, was combined thereby reducing the size of the data which should be processed and corrected. Results : Time savings of each proposed method are presented with different data size of brain images. In vivo data were processed using the proposed method and showed similar image quality. The total processing time was reduced to 15% in two dimensional images and 30% in the three dimensional images. Conclusion : The proposed methods can be useful in reducing image motion artifacts when only post-processing motion correction algorithms are available. The proposed methods can also be combined with parallel imaging technique to further reduce the processing times.

  • PDF

1 Case of Bronchial Leiomyoma with Intralobar Pulmonary Sequestration (폐 격리증을 동반한 기관지내 평활근종 1례)

  • Jung, Bo Yong;Kim, Do Hwan;Park, Eun Seo;Han, Seung Hoe;Kim, Young Tong;Oh, Mi Hye;Lee, Seok Yul;Choi, Jae Sung;Na, Joo Ock;Seo, Ki Hyun;Kim, Yong Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.678-683
    • /
    • 2006
  • Both bronchial leiomyoma and pulmonary sequestration are rare conditions, and to the best of our knowledge there are no reports of the two conditions coexisting. We report a female patient with bronchial leiomyoma with acquired pulmonary sequestration who presented with dyspnea, cough and purulent sputum. The patient had been treated for pneumonia at a local medical clinic. but was transferred to our clinic beacausr there was no clinical improvement. A 3-D computed tomography scan revealed a 1.5 cm sized mass near the distal portion of the left main bronchus and an anomalous artery arising from the aorta. The patient showed clinical improvement after a left lower lobectomy and a ligation of the anomalous artery.

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

Different Metabolic Patterns of Parkinsonism: Analysed by Statistical Parametric Mapping (통계적 파라미터를 이용한 Parkinsonism의 Metabolic pattern 분석)

  • 주라형;김재승;최보영;문대혁;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.108-123
    • /
    • 2003
  • The purpose of this study is to evaluate the contribution of $^{18}$ F-FDG brain PET in the differentiating Idiopathic parkinson's diesease (IPD), progressive supranuclear palsy (PSP), and multiple system atrophy (MSA). We studied 24 patients with parkinsonism : 8 patients (mean age 67.9$\pm$10.7 y: M/F : 3/5) with IPD, 9 patients (57.9$\pm$9.2 y : M/F : 4/5) with MSA and 7 patients (67.6$\pm$4.8 y : M/F 3/4) with PSP. All patients with parkinsonism and 22 age-matched normal controls underwent $^{18}$ F FDG PET in 3D mode after the injection of 370 MBq $^{118}$ F FDG. The patients with IPD, MSh and PSP were compared with a normal control group by a two-sided t-test of SPM99 (uncorrected P<0.001, extent threshold>100 voxel). All three parkinsonism groups, showed significant hypometabolism in the cerebral neocortex compared to the normal control group. However, the three groups displayed different metabolism in the subcortical structure, brain stem, and cerebellum. In IPD, there was no significant hypometabolism in the putamen, brain stem and cerebellum. However, MSA patients showed significant hypometabolism in the striatum, pons, and cerebellum compared to the normal controls and IPD patients. In addition, PSP showed significant hypometabolism in the caudate nuclei, the thalamus, midbrain, and the cingulate gyrus compared to the normal controls, the IPD, and MSA groups (IPD vs Normal sensitivity/specificity : 75%/l00%, MSA vs Normal sensitivity/specificity :100%/87%, PSP vs Normal sensitivity/specificity : 86%/94%). Our results show that the regional metabolism of IPD, MSA, and PSP is different mainly in the striatum, thalamus, brain stem and cerebellum. An assessment of the $^{18}$ F-FDG PET scan images using SPM may be a useful adjunct to a clinical examination in making a differential diagnosis of Parkinsonism.

  • PDF