• Title/Summary/Keyword: 3d Scan

Search Result 879, Processing Time 0.033 seconds

Laparoscopic Operation for Superior Mesenteric Artery Syndrome and Follow-up with 3-Dimensional Reconstructive CT - 1 Case Report - (상장간막동맥 증후군의 복강경 수술 및 3차원재건 복부 전산화단층촬영 영상을 이용한 추적관찰 -1예보고-)

  • Kim, Seong-Min;Kim, Sung-Hoon;Kwon, In-Kyou;Kim, Myoung-Joon;Hyoung, Woo-Jin;Choi, Seung-Hoon
    • Advances in pediatric surgery
    • /
    • v.11 no.2
    • /
    • pp.180-185
    • /
    • 2005
  • Superior mesenteric artery (SMA) syndrome is a rare disorder caused by extrinsic compression of the third portion of the duodenum by the SMA. The operative treatment of choice is bypassing the obstructed duodenal segment by duodenojejunostomy. We report one case of SMA syndrome treated by laparoscopic duodenojejunostomy and followed up by 3D-reconstructive CT scan. A fifteen-year-old boy with intermittent vomiting and weight loss was admitted. Ultrasonography showed narrowing of the distance between the SMA and aorta. Hypotonic duodenography showed dilatation of duodenal third portion and barium stasis. On 3Dreconstructive CT scan, the angle between SMA and aorta was $37^{\circ}$. The postoperative course was uneventful. Three months later, he had gained 3 kg of weight and the angle between SMA and aorta increased to $38-39^{\circ}$ on 3D reconstructive CT scan. Laparoscopic duodenojejunostomy for bypassing the obstructive duodenum in SMA syndrome is a feasible and safe method.

  • PDF

Building 3D model using laser scan data

  • Choi, Sung-Hun;Kim, Dong-Seok;Lee, Heung-Jae;Lee, Kwae-Hi
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.101-105
    • /
    • 2002
  • In this paper we describe techniques for the automated creation of geometric correct 3-D models of the building using two 2-D laser scanners. One of the laser scanners is used for position estimation using a scan matching algorithm, while the other is used to build 3-D models of the facade of the buildings. Those models can be used for virtual reality, tele-presence, digital cinematography and urban planning applications. Results are shown for building models in our campus using real data acquired from two sensors.

  • PDF

A study of making a dress form for women using a 3D printer (3D 프린터를 이용한 여성용 인대 제작 연구)

  • Oh, Seol Young
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.6
    • /
    • pp.725-742
    • /
    • 2016
  • In the Korean fashion industry, 3D printing systems are considered as new technology and a new opportunity. With 3D printers, consumers can be manufacturers and individuals can develop businesses with little upfront capital. In this study, a dress form for the typical Korean women's body shape was developed using 3D technology (3D scanning, 3D modeling, and 3D printing). Ten women with apparel sizes 85-91-160 were selected from 3D body-scan data collected by SizeKorea of 201 women aged 25 to 34 (2010). First, 15 horizontal cross-sections were collected from the 3D scan data of the 10 subjects. Then, inside lines of those cross-sections were drawn at 15-degree intervals, and the lengths were measured. The average of the inside lines was connected to the internal spline curve, and the curves were used as the average cross-sections. The average torso body and the dress form of Korean women were developed into a 3D solid model using a 3D CAD program (Solidworks 2012). An output mockup was printed by the FDM type's 3D printing system (Bonbot 1200, Bonbot 3-H4) using PLA material. The dimensions comparing the 3D solid modeling to the 3D printed mockup of the dress form were measured, and minor differences were between 0.00cm and 0.40cm. In the future, 3D printing systems are expected to be in use for various personalized dress forms.

Automated Silhouette Extraction Method for Generating a Blueprint from 3D Scan Data of Cultural Asset (문화재의 3D 스캔 데이터로부터 도면을 생성하기 위한 자동화된 실루엣 추출 방법)

  • Jung, Jung-Il;Cho, Jin-Soo;WhangBo, Tae-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.12
    • /
    • pp.10-19
    • /
    • 2008
  • In this paper, we propose an automated silhouette extraction method that can effectively extract inner-patterns and silhouettes from 3D scan data of cultural asset. First of all, after creating the edge list of 3D vector data, we decide contour edge and crease edge according to viewpoint. In the next step, after extracting surface silhouette by investigating the vector variation of adjacent faces in crease edge, we finally extract the contour silhouette and surface silhouette for generating the blueprint of cultural asset. To evaluate the performance of the proposed silhouette extraction method, we performed experiments of silhouette extraction using a traditional tile model, a car model and a stone monument model. Comparing with the conventional threshold-based silhouette extraction method, the proposed method extracted more distinct and clear surface silhouettes and inner-patterns by effectively removing meaningless edges, such as noise.

CAE Solid Element Mesh Generation from 3D Laser Scanned Surface Point Coordinates

  • Jarng S.S.;Yang H.J.;Lee J.H.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.3
    • /
    • pp.162-167
    • /
    • 2005
  • A 3D solid element mesh generation algorithm was newly developed. 3D surface points of global rectangular coordinates were supplied by a 3D laser scanner. The algorithm is strait forward and simple but it generates hexahedral solid elements. Then, the surface rectangular elements were generated from the solid elements. The key of the algorithm is elimination of unnecessary elements and 3D boundary surface fitting using given 3D surface point data.

Volume Change of Spiral Computed Tomography due to the Changed in the Parameters (파라미터의 변경에 따라 나선형 전산화 단층 촬영의 체적 변화)

  • Lee, JunHaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.307-311
    • /
    • 2013
  • This study examined the change of artifact volume by analyzing the level of image change associated with the setting of threshold through 3D imaging in scan parameter(slice thickness and helical pitch) and 3D image reconstruction to explore whether the presence of pathology was fully distinguished when CT was taken by lower dose than the existent dose to reduce exposure. Furthermore, this study attempted to investigate Scan Parameter acceptable in CT to reduce exposure dose. For materials and methods, silicon was used to produce samples. Five spherical samples were produced at 10-millimeter intervals(50, 40, 30, 20, and 10 mm) in diameter and were fixed at 120 Kvp of tube voltage and 50 mA of tube current. Varied slab thickness((1.0, 2.0, 3.0, 5.0, and 7.0mm) and Helical Pitch(1.5, 2.0, 3.0) were scanned. The image at an interval of 1.0, 2.0, 3.0, 5.0, and 7.0mm was transmitted to the workstation. Threshold(-200, -50, 50 ~ 1,000) was changed using the volume rendering technique, 3D image was reconstructed, and artifact volume was measured. In conclusion, 1.5 of Helical Pitch showed the least change of volume and 3.0 of helical pitch showed the greatest reduction of volume change. The experiment suggested that as slice thickness was increased, artifact volume was decreased more than actual measurement. Furthermore, in the 3D image reconstruction, when the range of threshold was set as -200 ~1,000, artifact volume was changed the least. Based on the results, it is expected to have an effect of reducing exposure dose.

The Qualitative Study on the Evaluation and the Application of 3D scan and virtual try-on technology (3차원 스캔과 가상 착의 기술의 평가와 활용에 관한 질적연구)

  • Choi, Young-Lim;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.11 no.3
    • /
    • pp.437-444
    • /
    • 2009
  • According to the activation of the fashion electronic commerce, this research investigated the merits and demerits and improvement plan of the 3D virtual try-on technology using the qualitative research method. This research was performed by interview with 70 evaluation group. The evaluation group of 3D virtual try-on was organized and the fit evaluation process by 3D human body scan and the 3D virtual try-on of the i-Fashion technology center were experienced. This study was performed by interview after the actual and virtual try-on about the casual shirt. The convenience and accuracy of measurement, usability in online shopping, body evaluation, complement of sizing system, and body shape management were discovered as merits. The requirement of high accuracy in sizing and avatar, limits of fabric expression, practical limitation by cost, vexatious of measurement garment, differences between real and virtual fittings, personal information leakage risk, and etc were pointed out as demerits. The mass customization, customized garment connected with medical service, humanized avatar, improved fitting report, entertainment, coordination, wardrobe manager were proposed as improvement plan.

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young;Choi, Chi Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.400-404
    • /
    • 2014
  • Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.

Torso Pattern Design for Korean Middle-Aged Women using 3D Human Body Scan Data (차원 인체 스캔 데이터를 활용한 한국 중년여성 토르소 원형 설계)

  • Kim, Hye-Jin;Park, Soon-Jee
    • Fashion & Textile Research Journal
    • /
    • v.13 no.4
    • /
    • pp.600-613
    • /
    • 2011
  • The purpose of this study is to provide Torso pattern for Korean middle-aged women using 3D human body scan data. 155 women in their 40's or 50's were measured by Martin's anthropometry. Merging the data of 914 middle aged women provided by Korean agency for technology and standards, total of 1,069 subjects' data were analyzed. For data analysis, ANOVA, factor analysis and cluster analysis were done using SPSS PC+. And representative subject of each cluster was selected and they participated in 3D scanning and Torso pattern suggested for middle-aged women Torso pattern which investing the amount of ease according to each group for diffuse front interscye 30%, armscye circumference 30%, back interscye 40% using 3D human body scan data. The results of this study are as follows. Firstly, as a result of the factor analysis, the first factor was 'obesity index of body', The second factor was 'verticality size of body', The third factor was 'verticality length of upper bodice', The fourth factor was 'drop value to represent silhouette', and the fifth factor was 'physique of upper bodice'. And, middle-aged women type were classified 3 types according to the cluster analysis. Type 1(Y-type) was the long upper Torso with wide shoulder. Type 2(H-type) was flat-body type with comparatively thin upper bodice and thin lower bodice. And type 3(A-type) was the obese type with comparatively thin upper bodice and fat lower bodice. Secondly, using CAD program, point filtering was performed and approximated surface model was made. It used that generated surface smoothing corrected for abnormally extruded points and scattered points based on the curvature information. And 3D surfaces were flatted onto the plane by the internal tools of CAD program. Difference ratios of outline length and area between 3D curves and 2D plane were 0.42% and 0.54%, respectively. Third, wearing test by the sensory evaluation showed that distinct difference almost every category. The movement functionality test shows that, in all the tests which reveal significant differences, especially, 'comparison pattern A' experienced inconvenience to neck width and neck depth.