• Title/Summary/Keyword: 3V

Search Result 24,165, Processing Time 0.061 seconds

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Structural Properties of Social Network and Diffusion of Product WOM: A Sociocultural Approach (사회적 네트워크 구조특성과 제품구전의 확산: 사회문화적 접근)

  • Yoon, Sung-Joon;Han, Hee-Eun
    • Journal of Distribution Research
    • /
    • v.16 no.1
    • /
    • pp.141-177
    • /
    • 2011
  • I. Research Objectives: Most of the previous studies on diffusion have concentrated on efficacy of WOM communication with the use of variables at individual level (Iacobucci 1996; Midgley et al. 1992). However, there is a paucity of studies which investigated network's structural properties as antecedents of WOM from the perspective of consumers' sociocultural propensities. Against this research backbone, this study attempted to link the network's structural properties and consumer' WOM behavior on cross-national basis. The major research objective of this study was to examine the relationship between network properties and WOM by comparing Korean and Chinese consumers. Specific objectives of this research are threefold; firstly, it sought to examine whether network properties (i.e., tie strength, centrality, range) affect WOM (WOM intention and quality of WOM). Secondly, it aimed to explore the moderating effects of cutural orientation (uncertainty avoidance and individuality) on the relationship between network properties and WOM. Thirdly, it substantiates the role of innovativeness as antecedents to both network properties and WOM. II. Research Hypotheses: Based on the above research objectives, the study put forth the following research hypotheses to validate. ${\cdot}$ H 1-1 : The Strength of tie between two counterparts within network will positively influence WOM effectivenes ${\cdot}$ H 1-2 : The network centrality will positively influence the WOM effectiveness ${\cdot}$ H 1-3 : The network range will positively influence the WOM effectiveness ${\cdot}$ H 2-1 : The consumer's uncertainty avoidance tendency will moderate the relationship between network properties and WOM effectiveness ${\cdot}$ H 2-2 : The consumer's individualism tendency will moderate the relationship between network properties and WOM effectiveness ${\cdot}$ H 3-1 : The consumer's innovativeness will positively influence the social network properties ${\cdot}$ H 3-2 : The consumer's innovativeness will positively influence WOM effectiveness III. Methodology: Through a pilot study and back-translation, two versions of questionnaire were prepared, one in Korean and the other in Chinese. The chinese data were collected from the chinese students enrolled in language schools in Suwon city in Korea, while Korean data were collected from students taking classes in a major university in Seoul. A total of 277 questionnaire were used for analysis of Korean data and 212 for Chinese data. The reason why Chinese students living in Korea rather than in China were selected was based on two factors: one was to neutralize the differences (ie, retail channel availability) that may arise from living in separate countries and the second was to minimize the difference in communication venues such as internet accessibility and cell phone usability. SPSS 12.0 and AMOS 7.0 were used for analysis. IV. Results: Prior to hypothesis verification, mean differences between the two countries in terms of major constructs were performed with the following result; As for network properties (tie strength, centrality and range), Koreans showed higher scores in all three constructs. For cultural orientation traits, Koreans scored higher only on uncertainty avoidance trait than Chinese. As a result of verifying the first research objective, confirming the relationship between network properties and WOM effectiveness, on Korean side, tie strength(Beta=.116; t=1.785) and centrality (Beta=.499; t=6.776) significantly influenced on WOM intention, and similar finding was obtained for Chinese side, with tie strength (Beta=.246; t=3.544) and centrality (Beta=.247; t=3.538) being significant. However, with regard to WOM argument quality, Korean data yielded only centrality (Beta=.82; t=7.600) having a significant impact on WOM, whereas China showed both tie strength(Beat=.142; t=2.052) and centrality(Beta=.348; t=5.031) being influential. To answer for the second research objective addressing the moderating role of cultural orientation, moderated regression anaylsis was performed and the result showed that uncertainty avoidance moderated between network range and WOM intention for both Korea and China, But for Korea, the uncertainty avoidance moderated between tie strength and WOM quality, while for China it moderated between network range and WOM intention. And innovativeness moderated between tie strength and WOM intention for Korea but it moderated between network range and WOM intention for China. As a result of analysing for third research objective, we found that for Korea, innovativeness positively influenced centrality only (Beta=.546; t=10.808), while for China it influenced both tie strength (Beta=.203; t=2.998) and centrality(Beta=.518; t=8.782). But for both countries alike, the innovativeness influenced positively on WOM (WOM intention and WOM quality). V. Implications: The study yields the two practical implications. Firstly, the result suggests that companies targeting multinational customers need to identify segments which are susceptible to the positive WOM and WOM information based on individual traits such as uncertainty avoidance and individualism and based on that, develop marketing communication strategy. Secondly, the companies need to divide the market on Roger's five innovation stages and based on this information, enforce marketing strategy which utilizes social networking tools such as public media and WOM. For instance, innovator and early adopters, if provided with new product information, will be able to capitalize upon the network advantages and thus add informational value to network operations using SNS or corporate blog.

  • PDF

Biomass and distribution of Antarctic Krill, Euphausia superba, in the Northern part of the South Shetland Islands, Antarctic Ocean (남극 남쉐틀란드 군도 북부 해역의 크릴 분포 및 자원량)

  • KANG Donhyug;HWANG Doojin;KIM Suam
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.6
    • /
    • pp.737-747
    • /
    • 1999
  • To estimate biomass and distribution of the Antarctic krill (Euphausia superba), hydroacoustic survey was conducted on board of R/V Yuzhmorgeologiya, which was chartered by Korea Antarctic Research Program (KARP) group from 18 to 21 December 1998, in the northern part of the South Shetland Islands, Antarctic Ocean, The scientific echo sounder (towing body type) used was EK- 500 (SIMRAD, Norway) with echo integrator (BI-500) at 38 kHz frequency and recorded mean backscattering cross-section coefficient (SA) per 1 $mile^2$ of sea surface. Also, Bongo net sampling was carried out to determine the size of krill and CTD (Conductivity, Temperature and Depth) casting to understand physical structure. Water column was divided into 5 layers (22$\~$65 m, 65$\~$115 m, l15$\~$65 m, 165$\~$215 m and 215$\~$315 m) to know vertical distribution of krill biomass. The standard length of krill collected was between 30 mm and 51 mm, and adult krill had single mode (41 mm). Maximum horizontal length of krill patch was about 35 nautical mile and vertical thickness was about 275 m. High density of krill was appeared in frontal area between Circumpolar Deep Water (>$1^{\circ}C$) and very low temperature water mass (< $-0.5^{\circ}C$) that originate from Weddell Sea. According to the results calculated using target strength equation, krill density was totally higher in continental slope and open water areas than in coastal area. In the study area, krill seems to distribute in depth; density was low at first layer ($\={\rho}=17.0\;g/m^2$) and higher at fourth layer ($\={\rho}=40.19\;g/m^2$). The estimated krill biomass at total survey area and water column was about 2.77 million metric ion ($\={\rho}=151.0\;g/m^2$) and coefficient of valiance ( CV, $\%$) was 19.92. The proportions and biomass of krill biomass at each layer were as follows; layer 1 ($11.3\%$, 0.31 million metric ton, CV=16.24), layer 2 ($13.3\%$, 0.37 million metric ton, CV=34.91), layer 3 ($23.7\%$, 0.66 million metric ton, CV=41.5), layer 4 ($26.6\%$, 0.74 million metric ton, CV=27.84) and layer 5 ($25\%$, 0.69 million metric ton, CV= 26.83).

  • PDF

Bronchial Brushing and Bronchial Washing for Diagnosis of Central Lung Cancer (중심형 폐암 진단을 위한 기관지찰과술과 기관지세척술)

  • Park, Ki-Su;Park, Jae-Yong;Cha, Seung-Ick;Son, Ji-Woong;Kim, Kwan-Young;Kim, Jeong-Seok;Chae, Sang-Cheol;Kang, Tae-Kyong;Park, Tae-In;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.817-825
    • /
    • 1999
  • Background : Forceps biopsy, bronchial brushing, and bronchial washing are used in conjunction with bronchoscopy to provide specimens for histologic and cytologic analysis in patients with suspected lung cancer. This study was performed to evaluate how many times brushing should be done and how much fluid should be used during bronchial washing for increasing diagnostic yield, and to evaluate which combination of these procedures gives the highest diagnostic yield. Methods : Forty patients, with suspected lung cancer, who had bronchoscopically visible lesions were enrolled in this prospective study. During one bronchoscopic examination four forceps biopsies, four bronchial brushings, and bronchial washing were done in all patients. The patients were divided into four groups by the amount of normal saline used for bronchial washing; group I, 10 ml ; group II, 20ml ; group III 30ml, and group IV, 40ml. We analyzed the results in 36 patients confirmed as lung cancer. Results : The diagnostic sensitivity of bronchial washing before and after forceps biopsy and bronchial brushing were 36% and 28%, respectively. The cumulative diagnostic sensitivity of bronchial washing was 47% and significantly higher than that of bronchial washing before or after forceps biopsy and bronchial brushing (p<0.05). The diagnostic sensitivity of bronchial washing with saline of 30ml was significantly higher than that of bronchial washing with saline of 10ml or 20ml (p<0.05). The diagnostic sensitivity of the first brushing was 75%, the second brushing 78%, the third brushing 83%, and the fourth brushing 67%. With repeated brushing up to three times, the diagnostic sensitivity increased to 92% (p<0.05). However, inclusion of the fourth brushing did not give a further increase of the diagnostic sensitivity. The diagnostic sensitivity of forceps biopsy was 86%. The diagnostic sensitivities of forceps biopsy by the type of bronchial lesion were as follows: tumor, 88%; infiltration, 67%; infiltration with nodularity, 80%; and collapse, 100%. The combination of forceps biopsy and bronchial washing gave a diagnostic sensitivity of 89%. The diagnostic sensitivity of combining forceps biopsy with bronchial brushing was 97%. Addition of bronchial washing did not increase the diagnostic yield over forceps biopsy and bronchial brushing. Conclusion : In patients with central lung cancer, forceps biopsies and repeated brushings up to three times should be done for maximal diagnostic yield.

  • PDF

Calculation of Unit Hydrograph from Discharge Curve, Determination of Sluice Dimension and Tidal Computation for Determination of the Closure curve (단위유량도와 비수갑문 단면 및 방조제 축조곡선 결정을 위한 조속계산)

  • 최귀열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.7 no.1
    • /
    • pp.861-876
    • /
    • 1965
  • During my stay in the Netherlands, I have studied the following, primarily in relation to the Mokpo Yong-san project which had been studied by the NEDECO for a feasibility report. 1. Unit hydrograph at Naju There are many ways to make unit hydrograph, but I want explain here to make unit hydrograph from the- actual run of curve at Naju. A discharge curve made from one rain storm depends on rainfall intensity per houre After finriing hydrograph every two hours, we will get two-hour unit hydrograph to devide each ordinate of the two-hour hydrograph by the rainfall intensity. I have used one storm from June 24 to June 26, 1963, recording a rainfall intensity of average 9. 4 mm per hour for 12 hours. If several rain gage stations had already been established in the catchment area. above Naju prior to this storm, I could have gathered accurate data on rainfall intensity throughout the catchment area. As it was, I used I the automatic rain gage record of the Mokpo I moteorological station to determine the rainfall lntensity. In order. to develop the unit ~Ydrograph at Naju, I subtracted the basic flow from the total runoff flow. I also tried to keed the difference between the calculated discharge amount and the measured discharge less than 1O~ The discharge period. of an unit graph depends on the length of the catchment area. 2. Determination of sluice dimension Acoording to principles of design presently used in our country, a one-day storm with a frequency of 20 years must be discharged in 8 hours. These design criteria are not adequate, and several dams have washed out in the past years. The design of the spillway and sluice dimensions must be based on the maximun peak discharge flowing into the reservoir to avoid crop and structure damages. The total flow into the reservoir is the summation of flow described by the Mokpo hydrograph, the basic flow from all the catchment areas and the rainfall on the reservoir area. To calculate the amount of water discharged through the sluiceCper half hour), the average head during that interval must be known. This can be calculated from the known water level outside the sluiceCdetermined by the tide) and from an estimated water level inside the reservoir at the end of each time interval. The total amount of water discharged through the sluice can be calculated from this average head, the time interval and the cross-sectional area of' the sluice. From the inflow into the .reservoir and the outflow through the sluice gates I calculated the change in the volume of water stored in the reservoir at half-hour intervals. From the stored volume of water and the known storage capacity of the reservoir, I was able to calculate the water level in the reservoir. The Calculated water level in the reservoir must be the same as the estimated water level. Mean stand tide will be adequate to use for determining the sluice dimension because spring tide is worse case and neap tide is best condition for the I result of the calculatio 3. Tidal computation for determination of the closure curve. During the construction of a dam, whether by building up of a succession of horizontael layers or by building in from both sides, the velocity of the water flowinii through the closing gapwill increase, because of the gradual decrease in the cross sectional area of the gap. 1 calculated the . velocities in the closing gap during flood and ebb for the first mentioned method of construction until the cross-sectional area has been reduced to about 25% of the original area, the change in tidal movement within the reservoir being negligible. Up to that point, the increase of the velocity is more or less hyperbolic. During the closing of the last 25 % of the gap, less water can flow out of the reservoir. This causes a rise of the mean water level of the reservoir. The difference in hydraulic head is then no longer negligible and must be taken into account. When, during the course of construction. the submerged weir become a free weir the critical flow occurs. The critical flow is that point, during either ebb or flood, at which the velocity reaches a maximum. When the dam is raised further. the velocity decreases because of the decrease\ulcorner in the height of the water above the weir. The calculation of the currents and velocities for a stage in the closure of the final gap is done in the following manner; Using an average tide with a neglible daily quantity, I estimated the water level on the pustream side of. the dam (inner water level). I determined the current through the gap for each hour by multiplying the storage area by the increment of the rise in water level. The velocity at a given moment can be determined from the calcalated current in m3/sec, and the cross-sectional area at that moment. At the same time from the difference between inner water level and tidal level (outer water level) the velocity can be calculated with the formula $h= \frac{V^2}{2g}$ and must be equal to the velocity detertnined from the current. If there is a difference in velocity, a new estimate of the inner water level must be made and entire procedure should be repeated. When the higher water level is equal to or more than 2/3 times the difference between the lower water level and the crest of the dam, we speak of a "free weir." The flow over the weir is then dependent upon the higher water level and not on the difference between high and low water levels. When the weir is "submerged", that is, the higher water level is less than 2/3 times the difference between the lower water and the crest of the dam, the difference between the high and low levels being decisive. The free weir normally occurs first during ebb, and is due to. the fact that mean level in the estuary is higher than the mean level of . the tide in building dams with barges the maximum velocity in the closing gap may not be more than 3m/sec. As the maximum velocities are higher than this limit we must use other construction methods in closing the gap. This can be done by dump-cars from each side or by using a cable way.e or by using a cable way.

  • PDF

A Study on the Job Activities of the Emergency Nurses (응급실 근무 간호사의 업무분석)

  • 김광주;이향련;김귀분
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.4
    • /
    • pp.709-728
    • /
    • 1995
  • The job related activities of sixty nine nurses, working in the emergency rooms of three university hospitals, were analyzed for six days according to preestablished checklist of nursing activities ; the frequency of these activities and the amount of time spent in each specific nursing activity. The established checklist was monitored every five minutes for the duration of the duty autu, thus producing 414 items of data. The data were not gathered on consecutive days but over the period of one month from May 6, 1994 to June 5, 1994. The following conclusions are derived from analysis of the data : 1. Twelve categories of nursing activities were obtained : The primary activity was communication related to the patient and all information pertaining to the patient. Other activities included maintaining the patient's record, observation and assessment of the patient, cooperation with other medical personnel, management of equipment and drugs, procedure and treatment, specimen collection, consultation and education for the patient, including drug management and personal hygiene and any other relevant education to the patient's condition. 2. The average frequency of categorized nursing activity can be classified as follows : communication related to patient was the highest at 17.6 times. The next was maintaining the patient's record at 17.3 times. The observation and assessment occurred 16.9 times. Consultation and education for patients and family, 8 times, medication, 5.7 times, and procedures and treatments, 6 times. 3. The average time required for each activity was as follows : 230.1 minutes (or maintaining the patient's record, 204.9 minutes for communication related to the patient, 199.2 minutes for observation and assessment, 71.2 minutes for medication, 66 minutes for consultation and education of the patient and family, and 51.8 minutes for procedures and treatment. 4. The most demanding nursing activity in the emergency room for the nurse was answering questions from the patient's family, maintaining communication between the medical staff, maintaining and reviewing the patient's charts, writing prescriptions and monitoring 1. V. infusion rates. 5. The most time consuming nursing activities for the emergency room nurse include maintaining and following the patient's charts, communication between the medical staff, answering questions from the patient's family, observation of the patient and relaying all of the appropriate patient information to the incoming nurses during a shift change. 6. The F-test was administered to measure the required time for the categorized nursing activities according to day, evening, and night-shift nurses. There were significant differences (p<.05) in specimen collection, observation and assessment, cooperation between medical staffs, personal hygiene, communication related to patient, education and re-search. Posterior multiple comparison test showed that specimen collection, cooperation between medical staffs and personal hygiene were mostly done by the evening-shift nurses. Also most observations and assessments were done by the night-shift nurses. Education and communication to patients were done by day-shift nurses. Thus there were significant difference between shifts for the main nursing activities. So there should considev a reallocation of the duty of nurses on each shift. 7. The F-test also indicated that there wes a similarity in time duration for procedures and treatments and for cooperation between medical staff and nurses in all three hospitals. However, the remaining categories of nursing activities also showed a significant difference between the three hospitals. This indicated that there were differences in each emergency room that influence time for each categorized nursing activities and this should be given more consideration. Recommendations : 1. A seasonal difference should be considered in the activities of nurses in the emergency room and a comparative analysis should be carried out to deter-mine seasonal differentiation. 2. A study on more objectively measurable nursing activities should be administered as well as one determining the subjective responds towards nursing activities in the emergency room.

  • PDF

Nose Changes after Maxillary Advancement Surgery in Skeletal Class III Malocclusion (골격성 III급 부정교합자에서 상악골 전방 이동술 후 코의 변화에 관한 연구)

  • Kang, Eun-Hee;Park, Soo-Byung;Kim, Jong-Ryoul
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.657-668
    • /
    • 2000
  • The purpose of this study was to evaluate the amount and interrelationship of the soft tissue of nose and maxillary changes and to identify the nasal morphologic features that indicate susceptibility to nasal deflection in such a manner that they would be useful in presurgical prediction of nasal changes after maxillary advancement surgery in skeletal Class III malocclusion. The sample consisted of 25 adult patients (13 males and 12 females) who had severe anteroposterior skeletal discrepancy. The patients had received presurgical orthodontic treatment. They underwent a Le Fort I advancement osteotomy, rigid internal fixation, alar cinch suture and V-Y advancement lip closure. The presurgical and postsurgical lateral cephalograms and lateral and frontal facial photographs were evaluated. The computerized statistical analysis was carried out. Soft tissue of nose change to h point change ratios were calculated by regression equations. The results were as follows 1. The correlation of maxillary hard tissue horizontal changes and nasal soft tissue vortical changes were high and the ${\beta}_0$ for soft tissue to ADV were 0.228 at ANt, 0.257 at SNt. 2. The correlation of maxillary hard tissue and nasal soft tissue horizontal changes were high and the ${\beta}_0$ for soft tissue to ADV were 0.484 at ANt, 0.431 at SNt, 0.806 at Sn. 3. The correlation of maxillary hard tissue horizontal changes and width changes of ala of nose were high and the ${\beta}_0$ lot alar base width ratio to ADV were 0.002. 4. The DRI, Prominence of nose, Pre-Op CA is not a quantitative measure that can be used clinically to improve the predictability of vertical and horizontal nasal tip deflection. In this study, increases in nasal tip projection and anterosuperior rotation occur when there is an anterior vector of maxillary movement. These nasal changes were Quantitatively correlated to magnitude of maxillary(A point) movement.

  • PDF

Application of the CRISPR/Cas System for Point-of-care Diagnosis of Cattle Disease (현장에서 가축질병을 진단하기 위한 CRISPR/Cas 시스템의 활용)

  • Lee, Wonhee;Lee, Yoonseok
    • Journal of Life Science
    • /
    • v.30 no.3
    • /
    • pp.313-319
    • /
    • 2020
  • Recently, cattle epidemic diseases are caused by a pathogen such as a virus or bacterium. Such diseases can spread through various pathways, such as feed intake, respiration, and contact between livestock. Diagnosis based on the ELISA (Enzyme-linked immunosorbent assay) and PCR (Polymerase chain reaction) methods has limitations because these traditional diagnostic methods are time consuming assays that require multiple steps and dedicated equipment. In this review, we propose the use of the CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats) Cas system based on DNA and RNA levels for early point-of-care diagnosis in cattle. In the CRISPR/Cas system, Cas effectors are classified into two classes and six subtypes. The Cas effectors included in class 2 are typically Cas9 in type II, Cas12 in type V (Cas12a and Cas12b) and Cas13 in type VI (Cas13a and Cas13b). The CRISPR/Cas system uses reporter molecules that are attached to the ssDNA strands. When the Cas enzyme cuts the ssDNA, these reporters either fluoresce or change color, indicating the presence of a specific disease marker. There are several steps in the development of a CRISPR/Cas system. The first is to select the Cas enzyme depending on DNA or RNA from pathogens (viruses or bacteria). Based on that, the next step is to integrate the optimal amplification, transducing method, and signal reporter. The CRISPR/Cas system is a powerful diagnostic tool using a gene-editing method, which is faster, better, and cheaper than traditional methods. This system could be used for early diagnosis of epidemic cattle diseases and help to control their spread.

Studies on Genetic Diversity and Phylogenetic Relationships of Korean Native Chicken using the Microsatellite Marker (Microsatellite Marker를 활용한 한국 토종닭 품종의 유전적 다양성 및 유연관계 분석)

  • Seo, Joo Hee;Oh, Jea-Don;Lee, Jun-Heon;Seo, Dongwon;Kong, Hong Sik
    • Korean Journal of Poultry Science
    • /
    • v.42 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • In this study, genotyping was executed by using 27 microsatellite markers for genetic diversity of 469 Korean Native Chickens [20 population, each population is 24 samples but Hanhyup A line is 13 samples). in total 469 samples were collected from National Institute of Animal Science (Korean Native Chicken (NR, NY, NG, NL and NW), Ogye (NO), Leghorn F,K (NF and NK), Black and Brown cormish (NH and NS), Rhode Island Red C, D (NC and ND), Total is 12 populations] and Hanhyup [H line (HH), F line (HF), G line (HG), V line (HV), S line (HS), W line (HW), Y line (HY), A line (HA), total is 8 populations]. [The allele number were observed 5 (ADL0268) to 20 (MCW0127) each markers. Observed heterozygostiy ($H_{obs}$), expected heterozygosity ($H_{exp}$), polymorphism Information Content (PIC) were observed 0.359 to 0.677, 0.668 to 0.881 and 0.646 to 0.869, respectively. Using these markers, the calculated the heterozygote deficit within chicken line ($F_{is}$) value each population from mean 0.117. Phylogenetic tree showing the genetic relationship among 20 population using standard genetic distance calculated from 27 microsatellite markers. genetic distances revealed the closest (0.175) between NC and ND. on the other hand, Farthest genetic distances (0.710) revealed between NF and HV. STRUCTURE analysis and Principal Components Analysis (PCA) showed that results of similar phylogenetic tree. The expected probability of identity values on random individuals (Total population and only Hanhyup line) was estimated at $8.80{\times}10^{-83}$ and $3.87{\times}10^{-117}$, respectively. In conclusion, This study shows the useful data that be utilized as a basic data of Korean Native Chicken breeding and development for commercial chicken industry to meet the consumer's demand.

Study on Resource Plants of the Mt. Geonji, Jeonju City (전주시 건지산 일대의 자원식물상 연구)

  • Oh, Hyun-Kyung;Beon, Mu-Sup;Lim, Seong-Gu;Park, Joon-Moh;Kim, Kae-Hwan
    • Korean Journal of Plant Resources
    • /
    • v.21 no.1
    • /
    • pp.73-82
    • /
    • 2008
  • The resource plants of the Mt. Geonji was listed 354 taxa; 92 families, 242 genera, 303 species, 48 varieties and 3 forms. 354 taxa listed consists of 205 taxa of edible plants(57.1%),234 taxa of medicinal plants(65.2%), 167 taxa of ornamental plants(46.5%) and 218 taxa of the others(60.7%). Specific plant species by floral region were total 22 taxa; Trapella sinensis var. antennifera in class IV, Iris ensata var. spontanea in Class II, 16 taxa(Salix glandulosa, Alnus hirsuta, Chrysosplenium flagelliferum, Mallotus japonicus, Ilex macropoda, Grewia biloba var. parviflora, Vaccinium oldhami, Lysimachia barystachys, Fraxinus mandshurica, etc.) in class I. The naturalized plants in this site were 12 families, 23 genera, 28 species, 2 varieties, 30 taxa(Bromus unioloides, Phytolacca americana, Oenothera erythrosepala, Ipomoea hederacea var. hederacea, Aster pilosus, Erechtites hieracifolia) and naturalization rate was 8.5% of all 354 taxa vascular plants. Wild plants disturbing ecosystem like Solanum carolinense and Ambrosia artemisiifolia var. elatior have been increasing. So, it needs continuing control and conservation measures on the plant ecosystem.